Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Combustion-assisted ink-jet printing of nuclear targets

Advances in target fabrication are critical to high-precision measurements in nuclear physics. This work details the preparation of patterned CeO 2 and ThO 2 architectures and thin-film targets via ink-jet deposition of combustible solutions. The produced targets were characterized by scanning electron microscopy (SEM), and by alpha-particle spectroscopy for radioactive targets to determine densities. Ink jet printing of the targets, used both ethanol and 2-methoxyethanol as solvents, with cerium or thorium nitrate as the oxidizer and acetylacetone as the fuel. Additionally, we found that the distance between each droplet dispersion (step size) played the most significant role in determining the final pattern uniformity and thickness. A 50 μm step size leads to relatively thick targets with a density of 350 μg/cm 2 . Significant overlap in droplet sizes leads to a heterogeneous target with an undesirable cracked surface structure. In contrast, 150 μm spacing yields thinner (20 μg/cm 2 ) patterned structures with excellent surface coverage. This method of Ink-jet printing provides a straightforward, scalable, and high-efficiency pathway to prepare custom made, high-quality targets for nuclear physics experiments.

CeO2↗

NASICON Na 3 V 2 (PO 4 ) 3 Enables Quasi-Two-Stage Na + and Zn 2+ Intercalation for Multivalent Zinc Batteries

Identifying positive electrode materials capable of reversible multivalent electrochemistry in electrolytes containing divalent ions such as Mg 2+ , Ca 2+ , and Zn 2+ at high operating potentials remains an ongoing challenge in “beyond lithium-ion” research. In this paper, we explore the Zn 2+ charge-storage mechanism of a vanadium-based Na + superionic conductor (NASICON), Na 3 V 2 (PO 4 ) 3 . By using X-ray synchrotron techniques to unravel potential-dependent structure–property relationships, we ascribe the reversible electrochemical behavior of Na 3 V 2 (PO 4 ) 3 to a quasi-two-stage intercalation process that involves both Na+ and Zn 2+ . Initial charging of Na 3 V 2 (PO 4 ) 3 leads to a Na + -extracted phase corresponding to Na 3 V 2 (PO 4 ) 3 , whereas subsequent discharge results predominantly in Na + intercalation followed by Zn 2+ intercalation. Operando X-ray diffraction of Na 3 V 2 (PO 4 ) 3 was used to study the phase changes associated with the first charge/discharge process, and ex situ measurements were used to precisely link the changes in the crystal structure to a quasi-two-stage intercalation of Na + and Zn 2+ . The corresponding changes in the V-oxidation state, V-O coordination, and the presence of Zn 2+ were confirmed by X-ray absorption spectroscopy. The results of this work present a comprehensive understanding of the charge-storage properties for a well-established NASICON structure that confers both the high capacity (~100 mA h g -1 ) and high potential (1.35 and 1.1 V vs Zn/Zn 2+ ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabricating Radial Groove Gratings Using Projection Photolithography

Projection photolithography has been used as a fabrication method for radial grove gratings. Use of photolithographic method for diffraction grating fabrication represents the most significant breakthrough in grating technology in the last 60 years, since the introduction of holographic written gratings. Unlike traditional methods utilized for grating fabrication, this method has the advantage of producing complex diffractive groove contours that can be designed at pixel-by-pixel level, with pixel size currently at the level of 45 45 nm. Typical placement accuracy of the grating pixels is 10 nm over 30 nm. It is far superior to holographic, mechanically ruled or direct e-beam written gratings and results in high spatial coherence and low spectral cross-talk. Due to the smooth surface produced by reactive ion etch, such gratings have a low level of randomly scattered light. Also, due to high fidelity and good surface roughness, this method is ideally suited for fabrication of radial groove gratings. The projection mask is created using a laser writer. A single crystal silicon wafer is coated with photoresist, and then the projection mask, with its layer of photoresist, is exposed for patterning in a stepper or scanner. To develop the photoresist, the fabricator either removes the exposed areas (positive resist) of the unexposed areas (negative resist). Next, the patterned and developed photoresist silicon substrate is subjected to reactive ion etching. After this step, the substrate is cleaned. The projection mask is fabricated according to electronic design files that may be generated in GDS file format using any suitable CAD (computer-aided design) or other software program. Radial groove gratings in off-axis grazing angle of incidence mount are of special interest for x-ray spectroscopy, as they allow achieving higher spectral resolution for the same grating area and have lower alignment tolerances than traditional in-plane grating scheme. This is especially critical for NASA Constellation- X project that will utilize hundreds of gratings all of which need to be precisely aligned for x-ray observation of space.

Iazikov, Dmitri↗

Multi-Layer Far-Infrared Component Technology

A method has been developed for fabricating high-reflectivity, multi-layer optical films for the terahertz wavelength region. A silicon mirror with 99.997-percent reflectivity at 70 micrometer wavelength requires an air gap of 17.50 micrometers and a silicon thickness of 5.12 micrometers. This approach obtains pre-thinned wafers of about 20 mm thickness in order to measure their thickness precisely. A gold annulus of appropriate thickness is deposited to reach the required total thickness. This, in turn, has the central aperture etched down to the desired final silicon thickness. Also, the novel Bragg stack optics in this innovation are key to providing Fabry-Perot spectroscopy and improved spectral component technologies of unprecedented resolution, free spectral range, and aperture.

Edwards, Oliver↗

Deciphering Nb 98 β decay with the Modular Total Absorption Spectrometer at ORNL

An assessment done under the auspices of the Organization for Economic Co-operation and Developement Nuclear Energy Agency (OECD-NEA) in 2007 suggested that the β decays of many abundantly produced fission products in nuclear reactors may be incomplete. In this assessment, the fission product 98 Nb was assigned the highest priority for study by total absorption spectroscopy due to its large cumulative fission branching fraction and because the β-decay data from several experiments are discrepant. To obtain the complete β-decay feeding pattern of 98 Nb and determine the impact on the average γ energy per 98 Nb β decay and v¯e emission calculations. The complete 98 Nb β-decay feeding pattern includes ground-state to ground-state β feeding and direct β feeding to the 0 + first-excited state (both have no associated γ rays), and the ground-state to excited-state β transitions followed by γ transitions to the ground state of the daughter nucleus, 98 Mo. The complete β-decay intensities of 98 Nb were measured with the Modular Total Absorption Spectrometer at Oak Ridge National Laboratory (ORNL). Here, the 98 Nb was produced by the β decay of mass 98 fission fragments at ORNL's On-Line Test Facility (OLTF) using proton-induced fission of 238 U. We find that changes to the current ENSDF assessment of 98 Nb β-decay intensity are required. We report improved uncertainties for the β-decay feeding values and report new β feedings to high-energy levels in 98 Mo. A more complete 98 Nb β-feeding pattern with improved accuracy and precision is offered. The impacts of the measured changes to the 98 Nb β-feeding pattern on both reactor decay heat calculations and predicted detection rates of reactor v¯e are presented. The Modular Total Absorption Spectrometer measurements of 98 Nb demonstrate the importance of reexamining and remeasuring complex β-decaying fission products with total absorption spectroscopy, including nuclei very near β stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafast Early Warning of Heart Attacks through Plasmon‐Enhanced Raman Spectroscopy using Collapsible Nanofingers and Machine Learning

Abstract As the leading cause of death, heart attacks result in millions of deaths annually, with no end in sight. Early intervention is the only strategy for rescuing lives threatened by heart disease. However, the detection time of the fastest heart‐attack detection system is >15 min, which is too long considering the rapid passage of life. In this study, a machine learning (ML)‐driven system with a simple process, low‐cost, short detection time (only 10 s), and high precision is developed. By utilizing a functionalized nanofinger structure, even a trace amount of biomarker leaked before a heart attack can be captured. Additionally, enhanced Raman profiles are constructed for predictive analytics. Five ML models are developed to harness the useful characteristics of each Raman spectrum and provide early warnings of heart attacks with >98% accuracy. Through the strategic combination of nanofingers and ML algorithms, the proposed warning system accurately provides alerts on silent heart‐attack attempts seconds ahead of actual attacks.

60 APPLIED LIFE SCIENCES↗

Stratospheric spectroscopy with the far-infrared spectrometer (FIRS-2) - Overview and recent results

The Smithsonian Astrophysical Observatory's program of balloon-borne stratospheric spectroscopic measurements is described, including instrumentation, recent scientific results, and future plans. The design and operation of the FIRS-2 far-infrared spectrometer is discussed. The current status of our efforts to recover mixing-ratio profiles with about 1 percent precision is presented. Representative recent results are shown giving mixing-ratio profiles from 20 to 50 km, selected from the suite HOCl, HCl, HF, NO2, N2O, HNO3, OH, HO2, H2O2, H2O (and isotopes), O2 (and isotopes), O3 (and isotopes), and CO2 (and isotopes). The utility of O2 and CO2 spectral lines for information on view angle or temperature and pressure is discussed. Future plans are mentioned, including the use of FIRS-2 on a balloon platform for UARS correlative measurements, the use of FIRS-2 on the NASA DC-8 platform for polar measurements, and the potential benefits of a FIRS instrument on a Shuttle platform.

Traub, Wesley A.↗

High Throughput, High Yield Fabrication of High Quantum Efficiency Back-Illuminated Photon Counting, Far UV, UV, and Visible Detector Arrays

In this paper we discuss the high throughput end-to-end post fabrication processing of high performance delta-doped and superlattice-doped silicon imagers for UV, visible, and NIR applications. As an example, we present our results on far ultraviolet and ultraviolet quantum efficiency (QE) in a photon counting, detector array. We have improved the QE by nearly an order of magnitude over microchannel plates (MCPs) that are the state-of-the-art UV detectors for many NASA space missions as well as defense applications. These achievements are made possible by precision interface band engineering of Molecular Beam Epitaxy (MBE) and Atomic Layer Deposition (ALD).

spectroscopy↗

Improved high-precision mass measurements of mid-shell neon isotopes

New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24-26 Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N = 14mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N = 20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Manipulating Pore Topology and Functionality to Promote Fluorocarbon-Based Adsorption Cooling

With the worldwide demand for refrigeration and cooling expected to triple, it is increasingly important to search for alternative energy resources to drive the refrigeration cycles with reduced electricity consumption. Recently, adsorption cooling has gained increased attention since energy reallocation in such systems is based on gas adsorption/desorption, which can be driven by waste/natural heat sources. Eco-friendly sorption-based cooling relies on the cyclic transfer of refrigerant gas from a high to low energy state by the pseudo-compression effect resulting from adsorption and desorption. The driving force for energy transfer relies on heat rather than electricity. The performance of a sorption chiller is primarily influenced by this cyclic sorption behavior, which is characterized as the working capacity of the porous sorbent. Thus increases in this working capacity directly translate to a more compact and efficient cooling system. How-ever, a lack of highly effective sorbent/refrigerant pairs lowers cooling performance, and therefore has limited applicability. To this end, synthetic metal-organic frameworks (MOFs) and covalent organic polymers (COPs) possess higher porosity and greater tunability leading to more substantial potential benefits for adsorption, compared to traditional sorbent materials. Similarly, hydrofluorocarbon refrigerants have more favorable applicability given ease of operation above atmospheric pressures due to suitable saturated vapor pressures and boiling points. For these reasons, our work focuses on an ongoing strategy to promote sorption cooling via improvements in the sorbent/refrigerant pair. Specifically, we target the interaction of hydrofluorocarbon refrigerants with MOF/COP materials at a molecular level by interpreting the host-guest chemistry and the role of framework pore topology. These molecular level differences translate to cooling performance, which is described herein. These strategies include engineering framework porosity (i.e., pore size, pore volume) by using elongated organic linkers and stereochemistry control during synthesis; manipulating the sorb-ate/sorbent interaction by introducing functional moieties or unsaturated metal centers to enhance working capacities in narrow pressure ranges; varying pore topology/morphology to impact adsorption isotherm behavior; and leveraging defective sites within the frameworks to further enhance adsorption capability. Here this atomic level understanding of sorb-ate-sorbent interactions is conducted using various in situ experimental techniques such as synchrotron-based X-ray diffraction, X-ray absorption spectroscopy, in situ Fourier transform infrared spectroscopy, and direct sorption energies determinization with calorimetry. Moreover, the experimentally studied interactions and the corresponding adsorption mechanism are corroborated by computational studies using density functional theory (DFT) and grand canonical Monte Carlo (GCMC) simulations. Using this approach, we envision the capability to engineer designed frameworks with precise molecular control to target refrigerant molecules and thereby enhance the performance of desired working pairs for sorption-based cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TDCOSMO. XII. Improved Hubble constant measurement from lensing time delays using spatially resolved stellar kinematics of the lens galaxy

Strong-lensing time delays enable measurement of the Hubble constant ($H_{0}$) independently of other traditional methods. The main limitation to the precision of time-delay cosmography is mass-sheet degeneracy (MSD). Some of the previous TDCOSMO analyses broke the MSD by making standard assumptions about the mass density profile of the lens galaxy, reaching 2% precision from seven lenses. However, this approach could potentially bias the $H_0$ measurement or underestimate the errors. For this work, we broke the MSD for the first time using spatially resolved kinematics of the lens galaxy in RXJ1131$-$1231 obtained from the Keck Cosmic Web Imager spectroscopy, in combination with previously published time delay and lens models derived from Hubble Space Telescope imaging. This approach allowed us to robustly estimate $H_0$, effectively implementing a maximally flexible mass model. Following a blind analysis, we estimated the angular diameter distance to the lens galaxy $D_{\rm d} = 865_{-81}^{+85}$ Mpc and the time-delay distance $D_{\Delta t} = 2180_{-271}^{+472}$ Mpc, giving $H_0 = 77.1_{-7.1}^{+7.3}$ km s$^{-1}$ Mpc$^{-1}$ - for a flat $\Lambda$ cold dark matter cosmology. The error budget accounts for all uncertainties, including the MSD inherent to the lens mass profile and the line-of-sight effects, and those related to the mass-anisotropy degeneracy and projection effects. Our new measurement is in excellent agreement with those obtained in the past using standard simply parametrized mass profiles for this single system ($H_0 = 78.3^{+3.4}_{-3.3}$ km s$^{-1}$ Mpc$^{-1}$) and for seven lenses ($H_0 = 74.2_{-1.6}^{+1.6}$ km s$^{-1}$ Mpc$^{-1}$), or for seven lenses using single-aperture kinematics and the same maximally flexible models used by us ($H_0 = 73.3^{+5.8}_{-5.8}$ km s$^{-1}$ Mpc$^{-1}$). This agreement corroborates the methodology of time-delay cosmography.

79 ASTRONOMY AND ASTROPHYSICS↗

Advances in secondary ion mass spectrometry for N-doped niobium

Accurate secondary ion mass spectroscopy measurement of nitrogen in niobium relies on the use of closely equivalent standards, made by ion implantation, to convert nitrogen signal intensity to nitrogen content by determination of relative sensitivity factors (RSFs). Accurate RSF values for ppm-range nitrogen contents are increasingly critical, as more precision is sought in processes for next-generation superconducting radiofrequency (SRF) accelerator cavities. Furthermore, factors influencing RSF value measurements were investigated with the aim of reliably attaining better than 10% accuracy in nitrogen concentrations at various depths into the bulk. This has been accomplished for materials typical of SRF cavities at the cost of increased attention to all aspects.

47 OTHER INSTRUMENTATION↗

Strain release through hydrogen bond–mediated layer twisting

Strain engineering, enabling the precise control over structure and functional properties, is a key strategy for the design of advanced materials. However, the mechanisms governing strain evolution and release at the nanoscale remain largely unexplored. In this study, we leverage in situ heating transmission electron microscopy and synchrotron x-ray spectroscopy to investigate the strain relaxation pathways of boehmite (γ-AlOOH) at 575 kelvin by revealing real-time structural dynamics. Through tracking the moiré pattern evolution, we identify distinct strain release mechanisms, including layer twisting, defect formation, and domain restructuring. Our neural network potential calculations reveal that energy fluctuations at small twist angles are dominated by an interference-like interaction modulation of hydrogen bonds between boehmite interlayers, with metastable twisted structures corresponding to local minima of the potential energy landscape. This work establishes a previously unidentified paradigm of two-dimensional layer twisting mediated by hydrogen bonding, offering insights into strain-driven transformation mechanisms, and thus may have broad implications for strain in material and earth sciences.

36 MATERIALS SCIENCE↗

Implementation of stacked ensemble machine learning for the detection of surrogate plutonium contamination in soil via LIBS

Supervised machine learning methods have demonstrated increased utility for the quantification of lanthanide and actinide elements in atomic spectroscopy applications. This study implements laser-induced breakdown spectroscopy (LIBS) for the identification of plutonium surrogate material (CeO 2 ) in soil matrices by training supervised machine learning methods on the recorded spectral data. A bagged ensemble using Random Forest yields the highest sensitivity predictions with a detection limit of 0.015 wt.% CeO 2 . However, high precision in Ce content prediction required the use of a stacked ensemble regression, which provided the superlative Ce quantification model with an error of 0.107% and a detection limit of 0.022 wt.%. Furthermore, the high performance of the stacked ensemble demonstrates its potential to enhance the accuracy and sensitivity of nuclear contaminant detection using field-deployable spectroscopic analyzers in real-world scenarios.

47 OTHER INSTRUMENTATION↗

Enhancing Oxygen Stability in Low-Cobalt Layered Oxide Cathode Materials by Three-Dimensional Targeted Doping

In this project, we propose to develop a new concept and a generic platform that can lead to the greatly enhanced stabilization of all high-energy cathode materials, and in particular high-nickel (Ni) and low-cobalt (Co) oxides. The new concept is a 3D doping technology that hierarchically combines surface and bulk doping. We will use surface doping to stabilize the surface of primary particles and also introduce dopants in the bulk to further enhance oxygen stability, conductivity, and structural stability in low-Co oxides under high voltage and deep discharging operating conditions. This new concept not only will deliver a low-cost, high-energy cathode but also will provide a generic method that can stabilize all high-energy cathodes. The proposed novel 3D doping approach is poised to resolve some longstanding challenges in fundamental doping effects on battery materials as well as to reduce Li-ion batteries’ cost and improve their safety, energy density, and lifetime. To tackle this problem, we have formed a highly complementary multi-university/national labs/industry team to enable a doping-central and systematic investigation of low-Co materials and create a knowledge base for many electrode materials to be used in advanced electric vehicles. The successful execution of the proposed project relies on five components that can be carried out by the complementary team members: (1) a theoretical investigation of the surface and bulk stabilizing dopants (Persson), (2) a precise synthesis of materials with targeted doping (Lin and Xin), (3) development of electrolytes for high-Ni low-Co oxides (Xu), (4) multi-scale characterization of the structures and their interfaces by scanning transmission electron microscopy (SEM) and synchrotron X-ray imaging and spectroscopy tools (Xin and Lin), and (5) pouch cell-level integration (Fan). The UCI-led project will enable a doping-central and systematic investigation of low-Co materials and create a knowledge base for many electrode materials to be used in advanced electric vehicles.

25 ENERGY STORAGE↗

Self-scanned photodiode array - High performance operation in high dispersion astronomical spectrophotometry

A multichannel spectrophotometric detector system has been developed using a 1024 element self-scanned silicon photodiode array, which is now in routine operation with the high-dispersion coude spectrograph of the University of Texas McDonald Observatory 2.7-m telescope. Operational considerations in the use of such arrays for high precision and low light level spectrophotometry are discussed. A detailed description of the system is presented. Performance of the detector as measured in the laboratory and on astronomical program objects is described, and it is shown that these arrays are highly effective detectors for high dispersion astronomical spectroscopy.

Vogt, S. S.↗