Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

SU-F-I-56: High-Precision Gamma-Ray Analysis of Medical Isotopes

Purpose: Advanced, time-resolved, Compton-suppressed gamma-ray spectroscopy with germanium detectors is implemented for assaying medical isotopes to study the radioactive decay process leading to a more accurate appraisal of the received dose and treatment planning. Lowell’s Array for Radiological Assay (LARA), a detector array that is comprised of six Compton-suppressed high-purity germanium detectors, is currently under development at UMass-Lowell which combines Compton-suppression and time-and-angle correlations to allow for highly efficient and highly sensitive measurements. Methods: Two isotopes produced Brookhaven Linac Isotope Producer (BLIP) were investigated. {sup 82}Sr which is the parent isotope for producing {sup 82}Rb is often used in cardiac PET. {sup 82}Sr gamma-ray spectrum is dominated by the 511keV photons from positron annihilation which prevent precise measurement of co-produced contaminant isotopes. A second project was to investigate the production of platinum isotopes. Natural platinum was bombarded with protons from 53MeV to 200MeV. The resulting spectrum was complicated due to the large number of stable platinum isotopes in the target, the variety of open reaction channels (p,xn), (p,pxn), (p,axn). Results: By using face-to-face NaI(Tl) counters 90-degrees to the Compton-suppressed germaniums to detect the 511keV photons, a much cleaner and more sensitive measurement of {sup 85}Sr and other contaminants was obtained. For the platinum target, we identified the production of {sup 188–189–191–195}Pt, {sup 191–192–193–194–195–196}Au and {sup 186–188–189–190–192–194–189–190–192–194}Ir. For example, at the lower energies (53 and 65MeV), we measured {sup 191}Pt production cross-sections of 144mb and 157mb. Considerable care was needed in following the process of dissolving and diluting the samples to get consistent results. The new LARA array will help us better ascertain the absolute efficiency of the counting system and more reliable production cross-sections. Conclusion: Modern HPGe spectroscopic techniques provide enhanced sensitivity, promising precise quantification of the quality of radioisotopes used in medical physics. Using new decay information may have non-trivial impact on treatment planning and dose-assessment.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-255: Accuracy and Precision of Dynamic Tracking Irradiation with VERO-4DRT System

Purpose: The VERO-4DRT system is able to provide dynamic tracking irradiation (DTI) for the target with respiratory motion. This technique requires enough commissioning for clinical implementation. The purpose of this study is to make sure the accuracy and precision of DTI using VERO- 4DRT through commissioning from fundamental evaluation to end-to-end test. Method: We evaluated several contents for DTI commissioning: the accuracy of absorption dose at isocenter in DTI, the field size and penumbra of DTI, the accuracy of 4D modeling in DTI. All evaluations were performed by respiratory motion phantom (Quasar phantom). These contents were compared the results between static irradiation and DTI. The shape of radiation field was set to square from 3 cm × 3 cm to 10 cm × 10 cm. The micro 3D chamber and Gafchromic EBT3 film were used for absorbed dose and relative dose distribution measurement, respectively. The sine and irregular shaped waves were used for demonstrative respiratory motion. The visicoil was implanted into the phantom for guidance of respiratory motion. The respiration patterns of frequency and motion amount were set to 10–15 BPM and 1–2 cm, respectively. Results: As the result of absorbed dose of DTI in comparison with static irradiation, the average dose error at isocenter was 0.5% even though various respiratory patterns were set on. As the result of relative dose distribution, the field size (set it on 50% dose line) was not significantly changed in all respiratory patterns. However, the penumbra was larger in greater respiratory motion (up to 4.1 mm). The 4D modeling coincidence between actual and created waves was within 1%. Conclusion: The DTI using VERO-4DRT can provide sufficient accuracy and precision in absorbed dose and distribution. However, the patientspecific quantitative internal margin corresponding respiratory motion should be taken into consideration with image guidance.

60 APPLIED LIFE SCIENCES↗

Poster - 53: Improving inter-linac DMLC IMRT dose precision by fine tuning of MLC leaf calibration

Purpose: To develop a method to improve the inter-linac precision of DMLC IMRT dosimetry. Methods: The distance between opposing MLC leaf banks (“gap size”) can be finely tuned on Varian linacs. The dosimetric effect due to small deviations from the nominal gap size (“gap error”) was studied by introducing known errors for several DMLC sliding gap sizes, and for clinical plans based on the TG119 test cases. The plans were delivered on a single Varian linac and the relationship between gap error and the corresponding change in dose was measured. The plans were also delivered on eight Varian 2100 series linacs (at two institutions) in order to quantify the inter-linac variation in dose before and after fine tuning the MLC calibration. Results: The measured dose differences for each field agreed well with the predictions of LoSasso et al. Using the default MLC calibration, the variation in the physical MLC gap size was determined to be less than 0.4 mm between all linacs studied. The dose difference between the linacs with the largest and smallest physical gap was up to 5.4% (spinal cord region of the head and neck TG119 test case). This difference was reduced to 2.5% after fine tuning the MLC gap calibration. Conclusions: The inter-linac dose precision for DMLC IMRT on Varian linacs can be improved using a simple modification of the MLC calibration procedure that involves fine adjustment of the nominal gap size.

60 APPLIED LIFE SCIENCES↗

Unveiling phase evolution of complex oxides toward precise solid-state synthesis

The precise synthesis of high-purity materials is crucial in accelerating materials discovery. However, the lack of theoretical understanding and practical guidance poses challenges, particularly for materials with compositional and structural complexity. Here, we propose a feasible principle toward synthesizing complex inorganic solids. This principle involves the introduction of an inducer that induces crucial intermediates, which in turn guide the synthesis pathway toward the target materials through structural templating, named inducer-facilitated assembly through structural templating (i-FAST). We validate this principle with three distinct oxides: garnet Li6.5La3Zr1.5Ta0.5O12, perovskite BaCo0.8Sn0.2O3, and pyrochlore Gd1.5La0.5Zr2O7. This structural templating approach enables synthesis along predesigned pathways, forming intermediates that are thermodynamically favored for prior formation and kinetically preferred for the final product, resulting in precisely synthesizing high-purity target materials. This study not only represents a substantial advancement in comprehending the interplay between thermodynamics/kinetics and phase evolution in complex solid synthesis but also provides an effective strategy for guiding exploratory solid-state synthesis.

Yang, Lin↗

Rational synthesis of atomically precise graphene nanoribbons directly on metal oxide surfaces

Atomically precise graphene nanoribbons (GNRs) attract great interest because of their highly tunable electronic, optical, and transport properties. However, on-surface synthesis of GNRs is typically based on metal surface–assisted chemical reactions, where metallic substrates strongly screen their designer electronic properties and limit further applications. In this work, we present an on-surface synthesis approach to forming atomically precise GNRs directly on semiconducting metal oxide surfaces. The thermally triggered multistep transformations preprogrammed in our precursors’ design rely on highly selective and sequential activations of carbon-bromine (C-Br) and carbon-fluorine (C-F) bonds and cyclodehydrogenation. The formation of planar armchair GNRs terminated by well-defined zigzag ends is confirmed by scanning tunneling microscopy and spectroscopy, which also reveal weak interaction between GNRs and the rutile titanium dioxide substrate.

36 MATERIALS SCIENCE↗

Precise calculations in simulations of the interaction of low energy neutrons with nano-dispersed media

We discuss properties of the interaction of slow neutrons with nano-dispersed media and their application for neutron reflectors. In order to increase the accuracy of model simulation of the interaction of neutrons with nanopowders, we perform precise quantum mechanical calculation of potential scattering of neutrons on single nanoparticles using the method of phase functions. We compare results of precise calculations with those performed within first Born approximation for nanodiamonds with the radius of 2–5 nm and for neutron energies 3 × 10{sup -7}–10{sup -3} eV. Born approximation overestimates the probability of scattering to large angles, while the accuracy of evaluation of integral characteristics (cross sections, albedo) is acceptable. Using Monte-Carlo method, we calculate albedo of neutrons from different layers of piled up diamond nanopowder.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precise measuring mass and spin of dark matter particles at ILC via singularities in the single lepton energy spectrum

We consider models, in which stability of Dark Matter particles D is ensured by the conservation of the new quantum number, called D-parity here. Our models contain also charged D-odd particle D{sup ±}. We propose method for precision measuring masses and spin of D-particles via the study of energy distribution of single lepton (e or μ) in the process e{sup +} e{sup −} → D{sup +} D{sup −} → DDW{sup +} W{sup −} with the observable state dijet + μ (or e) + nothing. It is shown that this distribution has kinematically determined singular points (upper edge and kinks or peak). Measuring of their positions allow to determine precisely masses of D and D{sup ±}. After this, even a rough measuring of corresponding cross section allows to determine the spin of D particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Description of Processes at Colliders in the SANC System

A review of the SANC computer system intended for theoretical support of experiments at colliders is presented. The system allows the precision predictions to be obtained semiautomatically for a wide class of particle interaction processes within the Standard Model. In this case, one considers total contributions of one-loop radiative corrections. Basic elements of the computer system are described, and examples of using the system for the high-precision description of certain processes of the Standard Model particle interactions are given. The MCSANC code developed using the Monte Carlo simulation is presented, which is used to calculate cross sections of a number of processes, investigated at the Large Hadron Collider. The prospects of research development in this field for theoretical support at future hadron and lepton colliders are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise Q value determinations for forbidden and low energy $\beta $-decays using Penning trap mass spectrometry

Nuclear β-decay provides a laboratory for investigating weak decays occurring inside the nuclear medium. This provides information on the resulting subtle nuclear and atomic effects, and on the underlying interaction and the properties of the particles that are involved, particularly of the neutrino. The Q value of the decay corresponds to the energy equivalent of the mass difference between parent and daughter atoms, and can be precisely and accurately measured using Penning trap mass spectrometry. In this paper we discuss Penning trap Q value measurements for forbidden β-decays of long-lived primordial nuclides, and for a subset of β-unstable nuclides that could potentially undergo a very low energy decay to an excited state in the daughter nucleus. Here we discuss applications of these measurements to tests of systematics in detectors that perform precise β-spectrum measurements, as inputs for theoretical shape factor, electron branching ratio and half-life calculations, and to identify nuclides that could serve as new candidates in direct neutrino mass determination experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise mass measurements of radioactive nuclides for astrophysics

Much of astrophysics is fueled by nuclear physics with observables, such as energy output and elements produced, that are heavily dependent on the masses of the nuclides. A mass precision of at least 50 keV/c 2 for many rare nuclides is needed to adequately discriminate models that explain the observables. In recent decades, the development of new facilities and mass-measurement techniques has made available a wealth of precise and accurate mass data. Further, the new data, in combination with novel codes and models, has greatly enhanced the understanding of astrophysical processes in the universe, but much is still to be learned.

79 ASTRONOMY AND ASTROPHYSICS↗

A precise measurement of the $B^0$ meson oscillation frequency

The oscillation frequency, Δm d , of B 0 mesons is measured using semileptonic decays with a D – or D* – meson in the final state. The data sample corresponds to 3.0fb –1 of pp collisions, collected by the LHCb experiment at centre-of-mass energies √s = 7 and 8TeV. A combination of the two decay modes gives Δm d =(505.0±2.1±1.0)ns –1 , where the first uncertainty is statistical and the second is systematic. This is the most precise single measurement of this parameter. It is consistent with the current world average and has similar precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision studies of observables in $p p \rightarrow W \rightarrow l\nu _l$ and $ pp \rightarrow \gamma ,Z \rightarrow l^+ l^-$ processes at the LHC

This report was prepared in the context of the LPCC "Electroweak Precision Measurements at the LHC WG" and summarizes the activity of a subgroup dedicated to the systematic comparison of public Monte Carlo codes, which describe the Drell-Yan processes at hadron colliders, in particular at the CERN Large Hadron Collider (LHC). This work represents an important step towards the definition of an accurate simulation framework necessary for very high-precision measurements of electroweak (EW) observables such as the $W$ boson mass and the weak mixing angle. All the codes considered in this report share at least next-to-leading-order (NLO) accuracy in the prediction of the total cross sections in an expansion either in the strong or in the EW coupling constant. The NLO fixed-order predictions have been scrutinized at the technical level, using exactly the same inputs, setup and perturbative accuracy, in order to quantify the level of agreement of different implementations of the same calculation. A dedicated comparison, again at the technical level, of three codes that reach next-to-next-to-leading-order (NNLO) accuracy in quantum chromodynamics (QCD) for the total cross section has also been performed. These fixed-order results are a well-defined reference that allows a classification of the impact of higher-order sets of radiative corrections. Several examples of higher-order effects due to the strong or the EW interaction are discussed in this common framework. Also the combination of QCD and EW corrections is discussed, together with the ambiguities that affect the final result, due to the choice of a specific combination recipe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

Abstract The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $$\upbeta $$ β -decay endpoint region with a sensitivity on $$m_\nu $$ m ν of 0.2 $$\hbox {eV}/\hbox {c}^2$$ eV / c 2 (90% CL). For this purpose, the $$\upbeta $$ β -electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6 keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $$\upbeta $$ β -electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% $$\hbox {T}_2$$ T 2 gas mixture at 30 K, as used in the first KATRIN neutrino-mass analyses, as well as a $$\hbox {D}_2$$ D 2 gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $$\sigma (m_\nu ^2)< {{10}^{-2}}{\hbox {eV}^{2}}$$ σ ( m ν 2 ) < 10 - 2 eV 2 [1] in the KATRIN neutrino-mass measurement to a subdominant level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Precision Electon Beam Polarimetry

Across the last three decades high precision electron beam polarimetry has been at the fore-front of progress made in leveraging the spin degrees of freedom in nuclear and particle physics experiments. We review the three main types of polarimeters, Compton, Møller and Mott, that are typically used in experiments. We report on some of the recent results in high precision electron polarimetry and some of the new ideas that are being explored for future application at current and proposed accelerators

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurements with an Electroweak Boson in the Final State with the ATLAS Detector

Measurements of the Drell-Yan production of W and Z/γ* bosons at the LHC provide a benchmark of our understanding of perturbative QCD and probe the proton structure in a unique way. The ATLAS collaboration has performed new measurements for W⁺, W⁻ and Z/γ* boson production, reaching unprecedented precision and strong constraints on parton distribution functions, in particular the strange quark density. Studying jet pro- duction in association with a vector boson, perturbative QCD predictions can be tested in a multi-scale environment. Once the QCD aspects of the vector boson production are understood, high precision measurements aim at the tests of the electroweak sector, such as measuring the W boson mass. Here, a selection of recent ATLAS measurements, as presented at the 21st Particles and Nuclei International Conference, in September 2017 in Beijing, China, is discussed..

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ASAP: Automatic Synthesis of Area-Efficient and Precision-Aware CGRAs

Coarse-grained reconfigurable accelerators (CGRAs) are a promising accelerator design choice that strikes a balance between performance and adaptability to different computing patterns across various applications domains. Designing a CGRA for a specific application domain involves enormous software/hardware engineering effort. Recent research works explore loop transformations, functional unit types, network topology, and memory size to identify optimal CGRA designs given a set of kernels from a specific application do- main. Unfortunately, the impact of functional units with different precision support has rarely been investigated. To address this gap, we propose ASAP – a hardware/software co-design framework that automatically identifies and synthesizes optimal precision-aware CGRA for a set of applications of interest. Our evaluation shows that ASAP generates specialized designs 3.2×, 4.21×, and 5.8× more efficient (in terms of performance per unit of energy or area) than non-specialized homogeneous CGRAs, for the scientific computing, embedded, and edge machine learning domains, respectively, with limited accuracy loss. Moreover, ASAP provides more efficient designs than other state-of-the-art synthesis frameworks for specialized CGRAs.

artificial intelligence↗

Superallowed Nuclear Beta Decays and Precision Tests of the Standard Model

For many decades, the main source of information on the top-left corner element of the Cabibbo–Kobayashi–Maskawa quark mixing matrix, V ud , was superallowed nuclear β decays with an impressive 0.01% precision. This precision, apart from experimental data, relies on theoretical calculations in which nuclear structure–dependent effects and uncertainties play a prime role. This review is dedicated to a thorough reassessment of all ingredients that enter the extraction of the value of V ud from experimental data. We try to keep balance between historical retrospect and new developments, many of which occurred in just the past 5 years. They have not yet been reviewed in a complete manner, not least because new results are forthcoming. This review aims to fill this gap and offers an in-depth yet accessible summary of all recent developments.

ab initio methods↗

A multimodal and integrated approach to interrogate human kidney biopsies with rigor and reproducibility: guidelines from the Kidney Precision Medicine Project

Comprehensive and spatially mapped molecular atlases of organs at a cellular level are a critical resource to gain insights into pathogenic mechanisms and personalized therapies for diseases. The Kidney Precision Medicine Project (KPMP) is an endeavor to generate three-dimensional (3-D) molecular atlases of healthy and diseased kidney biopsies by using multiple state-of-the-art omics and imaging technologies across several institutions. Obtaining rigorous and reproducible results from disparate methods and at different sites to interrogate biomolecules at a single-cell level or in 3-D space is a significant challenge that can be a futile exercise if not well controlled. Here we describe a “follow the tissue” pipeline for generating a reliable and authentic single-cell/region 3-D molecular atlas of human adult kidney. Our approach emphasizes quality assurance, quality control, validation, and harmonization across different omics and imaging technologies from sample procurement, processing, storage, shipping to data generation, analysis, and sharing. We established benchmarks for quality control, rigor, reproducibility, and feasibility across multiple technologies through a pilot experiment using common source tissue that was processed and analyzed at different institutions and different technologies. A peer review system was established to critically review quality control measures and the reproducibility of data generated by each technology before their being approved to interrogate clinical biopsy specimens. The process established economizes the use of valuable biopsy tissue for multiomics and imaging analysis with stringent quality control to ensure rigor and reproducibility of results and serves as a model for precision medicine projects across laboratories, institutions and consortia.

59 BASIC BIOLOGICAL SCIENCES↗