Controlled cooling of an electronic system based on projected conditions

Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controlled cooling of an electronic system based on projected conditions

Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrical Generation for More-Electric Aircraft Using Solid Oxide Fuel Cells

This report examines the potential for Solid-Oxide Fuel Cells (SOFC) to provide electrical generation on-board commercial aircraft. Unlike a turbine-based auxiliary power unit (APU) a solid oxide fuel cell power unit (SOFCPU) would be more efficient than using the main engine generators to generate electricity and would operate continuously during flight. The focus of this study is on more-electric aircraft which minimize bleed air extraction from the engines and instead use electrical power obtained from generators driven by the main engines to satisfy all major loads. The increased electrical generation increases the potential fuel savings obtainable through more efficient electrical generation using a SOFCPU. However, the weight added to the aircraft by the SOFCPU impacts the main engine fuel consumption which reduces the potential fuel savings. To investigate these relationships the Boeing 787­-8 was used as a case study.

787↗

Life Cycle Greenhouse Gas Emissions: Natural Gas and Power Production

This presentation was given at the EPRI Winter Meeting, Natural Gas Interest Group in February 2016 and provided the technical details behind and results from the life cycle greenhouse gas analysis of natural gas extraction across the United States and its use in power production relative to coal-fired power.

CH4↗

Formulations and Valid Inequalities for Optimal Black Start Allocation in Power Systems

The restoration of a power system after a blackout starts around units with enhanced technical capabilities, referred to as black start units (BSUs). We examine the planning problem of optimally allocating these units on the grid subject to a budget constraint. We present a mixed integer programming model based on current literature in power systems. Binary variables are associated with the allocation of BSUs and with the energization state of buses, branches, and generators of the power system over a time horizon. We extract a substructure of the feasible region which imposes the requirement that each island that appears during the restoration process must have at least one operational generator. We discuss three equivalent reformulations for this requirement. We introduce a family of exponentially many, polynomially separable, valid inequalities to strengthen the formulation. Under simplifying assumptions, we show that the convex hull of the feasible region is a full-dimensional polyhedron, and prove that some of the constraints we introduced are facet-defining. We perform experiments to examine the difference in strength between the formulations as well as the computational times to solve the problem to near optimality for synthetic instances of the IEEE-39, IEEE-118, Illinois-200, WECC-225, IEEE-300, South Carolina-500, and Texas-2000 power systems. We illustrate a use case of the model. We conclude by suggesting extensions of the current work for future research.

Black Start Allocation↗

Automatic recognition system for document digitization in nuclear power plants

With the increasing number of data-driven models in nuclear applications, large volumes of numerical data are required to accurately model and predict the health status of a plant component. However, many historical operation logs that contain useful information are not fully utilized due to the lack of a systematic approach of digitization. To overcome this issue, this study proposes an automatic pipeline for extracting information from handwritten tabular documents collected from nuclear power plants. In our pipeline, we first denoise scanned documents with morphological operations, and then extract relevant parts from individual pages using both traditional computer vision and neural network methods. Handwriting recognition is applied to obtain text and numbers. As the most challenging step is how to crop only relevant information, the main focus of our paper is to detect tables and cells from scanned handwritten documents. Here we evaluate the efficiency and accuracy of our proposed method on handwritten operational reports obtained from a real-world case study. The results demonstrate the high accuracy and practicality of our proposed method.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Energy–Performance Trade-offs in Privacy-Preserving Federated Learning on SmartNIC-Enabled HPC Systems

Federated learning (FL) is increasingly deployed on accelerator-rich high-performance computing (HPC) systems, yet the system-level energy cost of privacy-aware FL remains poorly understood, particularly across heterogeneous networking and server-placement options. We present a measurement-driven study of energy–performance trade-offs for FL on GH200-class nodes across three deployment configurations: CPU-Ethernet, CPU-InfiniBand (RDMA-capable), and a DPU-hosted FL server over InfiniBand using a BlueField-3 SmartNIC/DPU. Using NVIDIA FLARE (NVFLARE), we align node-level power telemetry with per-round timing extracted from NVFLARE logs to quantify time-to-solution (TTS), energy-to-solution (ETS), energy-delay product (EDP), and synchronization behavior for three transformer models (ALBERT, DistilBERT, BERT), trained with and without differential privacy (DP). We find that interconnect choice is the dominant driver of runtime and energy: host-managed InfiniBand consistently reduces communication overhead versus Ethernet, yielding lower TTS/ETS/EDP. In contrast, in our NVFLARE deployment, placing the FL server on the DPU does not consistently match CPU-InfiniBand performance and can be slower—especially for larger models—highlighting that server placement alone is not sufficient to guarantee end-to-end gains. Finally, under our fixed-round protocol, DP increases per-round cost and runtime variance; ETS increases largely in proportion to TTS because average node power remains relatively stable across configurations.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

Cui, Tao↗

A decision support system prototype including human factors based on the TOGA meta-theory approach

The human contribution to the risk of operation of complex technological systems is often not negligible and sometimes tends to become significant, as shown by many reports on incidents and accidents occurred in the past inside Nuclear Power Plants (NPPs). An error of a human operator of a NPP can derive by both omission and commission. For instance, complex commission errors can also lead to significant catastrophic technological accidents, as for the case of the Three Mile Island accident. Typically, the problem is analyzed by focusing on the single event chain that has provoked the incident or accident. What is needed is a general framework able to include as many parameters as possible, i.e. both technological and human factors. Such a general model could allow to envisage an omission or commission error before it can happen or, alternatively, suggest preferred actions to do in order to take countermeasures to neutralize the effect of the error before it becomes critical. In this paper, a preliminary Decision Support System (DSS) based on the so-called (-) TOGA meta-theory approach is presented. The application of such a theory to the management of nuclear power plants has been presented in the previous ICAPP 2011. Here, a human factor simulator prototype is proposed in order to include the effect of human errors in the decision path. The DSS has been developed using a TRIGA research reactor as reference plant, and implemented using the LabVIEW programming environment and the Finite State Machine (FSM) model The proposed DSS shows how to apply the Universal Reasoning Paradigm (URP) and the Universal Management Paradigm (UMP) to a real plant context. The DSS receives inputs from instrumentation data and gives as output a suggested decision. It is obtained as the result of an internal elaborating process based on a performance function. The latter, describes the degree of satisfaction and efficiency, which are dependent on the level of responsibility related to each professional role. As an application, we present the simulation of the discussed error, e.g. the unchecked extraction of the control rods during a power variation maneuver and we show how the effect of human errors can affect the performance function, giving rise to different countermeasures which could call different operator figures into play, potentially not envisaged in the standard procedure. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power modeling of degraded PV systems: Case studies using a dynamically updated physical model (PV-Pro)

Power modeling, widely applied for health monitoring and power prediction, is crucial for the efficiency and reliability of Photovoltaic (PV) systems. The most common approach for power modeling uses a physical equivalent circuit model, with the core challenge being the estimation of model parameters. Traditional parameter estimation either relies on datasheet information, which does not reflect the system's current health status, especially for degraded PV systems, or requires additional I-V characterization, which is generally unavailable for large-scale PV systems. Thus, we build upon our previously developed tool, PV-Pro (originally proposed for degradation analysis), to enhance its application for power modeling of degraded PV systems. PV-Pro extracts model parameters from production data without requiring I-V characterization. This dynamic model, periodically updated, can closely capture the actual degradation status, enabling precise power modeling. PV-Pro is compared with popular power modeling techniques, including persistence, nominal physical, and various machine learning models. The results indicate that PV-Pro achieves outstanding power modeling performance, with an average nMAE of 1.4 % across four field-degraded PV systems, reducing error by 17.6 % compared to the best alternative technique. Furthermore, PV-Pro demonstrates robustness across different seasons and severities of degradation. The tool is available as a Python package at https://github.com/DuraMAT/pvpro.

14 SOLAR ENERGY↗

An Integrated Energy Systems Prototype Human-System Interface for a Steam Extraction Loop System to Support Joint Electricity-Hydrogen Flexible Operations

Due to increasing economic competition from renewables and combined-cycle natural gas plants, nuclear power plants are looking toward flexible operations to enhance their cost competitiveness. The Integrated Energy Systems project under the Light Water Reactor Sustainability program of the U.S. Department of Energy focuses on joint electricity-hydrogen flexible operations. Joint electricity-hydrogen flexible operations entail the nuclear power plant diverting thermal energy via main steam to a hydrogen production plant located nearby. The steam serves to enhance the efficiency of the hydrogen production. Furthermore, high temperature electrolysis requires a large amount of electricity, which the plant can also provide. The plant provides steam and electricity to the hydrogen plant throughout the day, but during peak demand hours the nuclear power plant returns to solely providing electricity to meet the high demand. Through this flexible concept of operations, the plant can optimize the thermal energy it produces without having to maneuver the power of the plant. This report documents the human factors process to design and develop a prototype human-system interface for the steam extraction loop that serves as the conduit between the nuclear power plant and the adjacent hydrogen plant. The design process followed the human factors guidelines set by NUREG-0711, Human Factors Engineering Program Review Model (O’Hara, Higgins, & Fleger, 2012), and expanded upon by the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE; Boring, Ulrich, Joe, & Lew, 2015; Boring, Lew, & Ulrich, 2016). The design process entailed operator interviews to determine the concept of operations for the steam extraction loop, a review and adaptation of digital interface design concepts developed by the team in prior projects, an iterative design process, and reviews conducted by both operators and human factors experts. Several versions of the prototype human-system interface were developed. Operators were interviewed to determine what design features they found useful and would like to see in the interface. The design underwent a review by human factors experts against NUREG-0700, Human Interface Design Review Guidelines (U.S. Nuclear Regulatory Commission, 2019), to ensure compliance with the latest human factors standards for digital interfaces in nuclear applications. The design was then prototyped as a functional windows-based application integrated with the Generic Pressurized Water Reactor simulator modified to include the steam extraction loop. The simulation is supported by the Human Systems Simulation Laboratory at Idaho National Laboratory, which supports operator-in-the-loop testing. This is an ongoing project and the next phase of the project entails performing an operator-in-the-loop usability study to evaluate the interface and examine the proposed concept of operations to extraction steam from the nuclear power plant for delivery to the coupled hydrogen production plant.

99 GENERAL AND MISCELLANEOUS↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators that sense energy depositions in the substrate through a transient shift in their resonant frequency. In this work, I installed new devices in the QUIET cryogenic facility and used a network analyzer to drive them across a range of power levels. At each setting, I measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. Despite the increased noise at low power, the model consistently captured the resonance behavior. I first measured the resonance parameters as a function of RF drive power, then repeated the measurement across a range of temperatures to test whether the device behaved like an MKID. While the notch-filter fits captured the resonance reliably, the observed temperature dependence did not match the expected MKID signature — indicating that these first in-house fabricated chips are not yet functioning as true MKIDs. Overall, this reframes our work as a study of resonance parameter extraction and identification, pointing towards future iterations of device design and fabrication to get the true MKID response.

Savitala, Akash [U. Washington, Seattle (main); Fe↗

Towards 20 A negative hydrogen ion beams for up to 1 h: Achievements of the ELISE test facility (invited)

The large-scale RF-driven ion source of the test facility extraction from a large ion source experiment is aimed to deliver an accelerated ion current of 20 A D{sup −} (23 A H{sup −}) with an extracted electron-to-ion ratio below one for up to 1 h. Since the first plasma pulses for 20 s in volume operation in early 2013, followed by caesiation of the ion source, substantial progress has been achieved in extending the pulse length and the RF power. The record pulses in hydrogen are stable 400 s pulses with an extracted ion current of 18.3 A at 180 kW total RF power and 9.3 A at 80 kW stable for 1 h. For deuterium pulse, length and RF power are limited by the amount of co-extracted electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved determination of the short-circuit current density of silicon solar cells via lock-in thermography

We present a spatially resolved method to determine the short-circuit current density of crystalline silicon solar cells by means of lock-in thermography. The method utilizes the property of crystalline silicon solar cells that the short-circuit current does not differ significantly from the illuminated current under moderate reverse bias. Since lock-in thermography images locally dissipated power density, this information is exploited to extract values of spatially resolved current density under short-circuit conditions. In order to obtain an accurate result, one or two illuminated lock-in thermography images and one dark lock-in thermography image need to be recorded. The method can be simplified in a way that only one image is required to generate a meaningful short-circuit current density map. The proposed method is theoretically motivated, and experimentally validated for monochromatic illumination in comparison to the reference method of light-beam induced current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Water, Energy, and Carbon Dioxide Sequestration Simulation Model (WECSsim™): A User’s Manual

The Water, Energy, and Carbon Sequestration Simulation Model (WECSsim) is a national dynamic simulation model that calculates and assesses capturing, transporting, and storing CO 2 in deep saline formations from all coal and natural gas-fired power plants in the U.S. An overarching capability of WECSsim is to also account for simultaneous CO 2 injection and water extraction within the same geological saline formation. Extracting, treating, and using these saline waters to cool the power plant is one way to develop more value from using saline formations as CO 2 storage locations. WECSsim allows for both one-to-one comparisons of a single power plant to a single saline formation along with the ability to develop a national CO 2 storage supply curve and related national assessments for these formations. This report summarizes the scope, structure, and methodology of WECSsim along with a few key results. Developing WECSsim from a small scoping study to the full national-scale modeling effort took approximately 5 years. This report represents the culmination of that effort. The key findings from the WECSsim model indicate the U.S. has several decades' worth of storage for CO 2 in saline formations when managed appropriately. Competition for subsurface storage capacity, intrastate flows of CO 2 and water, and a supportive regulatory environment all play a key role as to the performance and cost profile across the range from a single power plant to all coal and natural gas-based plants' ability to store CO 2 . The overall system's cost to capture, transport, and store CO 2 for the national assessment range from $\$$74 to $\$$208 / tonne stored ($\$$96 to 272 / tonne avoided) for the first 25 to 50% of the 1126 power plants to between $\$$1,585 to well beyond $\$$2,000 / tonne stored ($\$$2,040 to well beyond $\$$2,000 / tonne avoided) for the remaining 75 to 100% of the plants. The latter range, while extremely large, includes all natural gas power plants in the U.S., many of which have an extremely low capacity factor and therefore relatively high system's cost to capture and store CO 2 .

20 FOSSIL-FUELED POWER PLANTS↗

Automated detection of photovoltaic cleaning events: A performance comparison of techniques as applied to a broad set of labeled photovoltaic data sets

Extracting accurate soiling loss information from photovoltaic (PV) production data first requires segmenting the time series data per natural or manually occurring cleaning events. Maintenance logs are often incomplete, rain data are often unavailable, and the debate on rain thresholds for cleaning and dew or wind cleanings is still ongoing. The present work aims to overtake these issues by improving automated methods to detect these cleaning events and therefore improve extraction of soiling loss information. Time series power production data from 22 PV inverters were labeled for natural or manually occurring cleaning events. The data sets were carefully selected to include varying degrees of soiling, cleaning events, and noise. Several algorithms, including filtering logic and change point detection, were examined for efficacy at detecting the labeled cleanings. All the methods introduced except for changepoint detection showed significant improvement at detecting the labeled cleaning events per the mean F 1 score. Furthermore, the highest performing cleaning detection algorithm achieved an absolute increase in the mean F 1 score of 43% over the default version of the RdTools stochastic rate and recovery (SRR) algorithm. The highest performing algorithm included irradiance filtering and a cleaning detection threshold, adjusted based on the 40-day centered rolling median of the absolute day-to-day deviations in the daily performance index (PI). Furthermore, these improvements are promising as cleaning detection is an essential step in the automated analysis of PV soiling.

14 SOLAR ENERGY↗

AFC-1 Fuel Rodlet Fission Power Deposition Validation in ATR

One of the viable options of long-term geological disposal of the nuclear power reactors generated spent fuel is to extract plutonium, the minor actinides (MA) and potentially long-lived fission products from the spent fuel and transmute them into short-lived or stable radionuclides in an appropriate reactor for the reduction of the radiological toxicity of the nuclear waste stream. An important component of that technology will be a non-fertile / low-fertile actinide transmutation fuel form containing the plutonium, neptunium, americium (and possibly curium) isotopes to be transmuted. Such advanced fuel forms, especially ones enriched in the long-life minor actinide (LLMA) elements (i.e., Np, Am, Cm), have minimal irradiation performance data available from which to establish a transmutation fuel form design. Recognizing these needs, an Advanced Fuel Cycle test series-1 (AFC-1) irradiation test on a variety of candidate fuel forms is now being conducted in Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). The first advanced fuel experiment (AFC-1) has been finalized and the test assembly analyzed for insertion and irradiation in ATR. The ATR core consists of a serpentine and rotationally symmetric fuel assembly about the z-axis of the core center. The plan view of the ATR core configuration is shown in Fig. 5, in Ref. 1. A cadmium filter with a 0.178 cm (0.045") thickness and 121.5 cm (48") in length, is currently used in the actinide-fuel capsule design for the East Flux Trap (EFT) position in ATR, to depress the linear heat generation rate (LHGR) lower than the project’s 330 W/cm limit for the experimental fuel rodlets. The LHGR is proportional to the fission power deposited in the fuel rodlets from the neutron fissions. The fraction of the fission power generated from the neutron fission reactions deposited in the fuel rodlet is an important parameter for test assembly thermal analysis, which will be validated in this summary.