Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polyethylene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Aligned Boron Nitride Nanotube Reinforced Polyethylene Nanocomposite for Space Radiation Shielding

With NASA’s Artemis program aiming to establish a human presence on the Moon and eventually on Mars, protecting astronauts from radiation is necessary. Flight-heritage materials, like those with high hydrogen content, such as polyethylene (PE), have proven to be effective radiation shields. This is due to hydrogen’s high charge-to-mass ratio, low secondary radiation production, efficient energy absorption, and high cross-section, which increases the probability of particle interactions to slow or stop ionized particles. Boron nitride nanotubes (BNNTs) and other boron-rich materials offer more effective thermal neutron radiation-stopping capabilities due to their high cross-section and neutron absorption properties. BNNTs also enhance the mechanical properties of radiation shielding material due to their high strength-to-weight ratios. However, integrating high volumes of nanotubes in a matrix without defects presents significant manufacturing challenges. To address this, a bulk nanocomposite laminate fabricating technique, involving synthesizing millimeter-long vertically aligned BNNTs, densifying the nanotubes to high-volume fractions, and infusing the nanotubes with PE while applying heat and pressure was utilized to fabricate the BNNT-PE nanocomposite that was tested for its radiation shielding properties at NASA Langley Research Center’s neutron radiation exposure lab. Results from these experiments will be discussed in the presentation.

Palak B Patel↗

Benchmark models and experimental data for a U(20) polyethylene-moderated critical system

This work involves the analysis of recent experiments performed on the Aerojet General Nucleonics (AGN)-201M (AGN) polyethylene-moderated research reactor at the University of New Mexico (UNM). The experiments include 36 delayed critical (DC) configurations and 11 positive-period and rod-drop measurements (transient sequences). The Even Parity Neutron Transport (EVENT) radiation transport code was chosen to analyze these steady state and time-dependent experimental configurations. The UNM AGN specifications provided in a benchmark calculation report (2007) were used to initiate AGN EVENT model development and to test the EVENT AGN calculation methodology. The results of the EVENT DC experimental analyses compared well with the experimental data; the average AGN EVENT calculation bias in the k eff is –0.0048% for the Legrendre Flux Expansion Order of 11 (P 11 ) cases and +0.0119% for the P 13 cases. The EVENT transient analysis also compared well with the AGN experimental data with respect to predicting the reactor period and control rod worth values. This paper discusses the benchmark models used, the recent experimental configurations, and the EVENT experimental analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Models and experimental data for a U(20)-Polyethylene-moderated critical system - 14650

This work involves the analysis of recent experiments performed on the Aerojet General Nucleonics (AGN)-201M (AGN) polyethylene-moderated research reactor at the University of New Mexico (UNM). The experiments include 36 delayed critical (DC) configurations and 11 positive-period and rod-drop measurements (transient sequences). The Even Parity Neutron Transport (EVENT) radiation transport code was chosen to analyze these steady state and time-dependent experimental configurations. The UNM AGN specifications provided in a benchmark calculation report (2007) were used to initiate AGN EVENT model development and to test the EVENT AGN calculation methodology. The results of the EVENT DC experimental analyses compared well with the experimental data; the average AGN EVENT calculation bias in the k{sub eff} is -0.0048% for the Legendre Flux Expansion Order of 11 (P{sub 11}) cases and +0.0119% for the P{sub 13} cases. The EVENT transient analysis also compared well with the AGN experimental data with respect to predicting the reactor period and control rod worth values. This paper discusses the benchmark models used, the recent experimental configurations, and the EVENT experimental analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Polyethylene Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 19, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc depositing energy in a Si solid state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Catalytic Activation of Polyethylene Model Compounds Over Metal-Exchanged Beta Zeolites

Decomposition of polymers by heterogeneous catalysts presents a promising approach for reuse of waste plastics. Here, we demonstrated non-hydrogenative decomposition of model polyolefins over proton-form and metal (Cu, Ni) ion-exchanged beta zeolites at moderate temperatures (ca. 300 degrees C). Near complete polyolefin decomposition was observed in batch reactions monitored by thermogravimetric analysis, while decomposition at partial conversion was studied in flow reactions. Ni-exchanged zeolites produced H 2 at substantially higher rates (> 10x) than other catalysts while also uniquely resisting deactivation over time. Application of the delplot formalism offered insights into the reaction network for polyolefin decomposition over Ni/BEA, most notably that H 2 is solely a primary product. We deduce that H 2 production is catalyzed by activation of C-H bonds at ionic Ni sites, and H 2 prevents buildup of polyaromatic coke species in Ni-exchanged zeolites that deactivate Cu-exchanged and protonic zeolites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Multi-institutional Clinical Trial of Rectal Dose Reduction via Injected Polyethylene-Glycol Hydrogel During Intensity Modulated Radiation Therapy for Prostate Cancer: Analysis of Dosimetric Outcomes

Purpose: To characterize the effect of a prostate-rectum spacer on dose to rectum during external beam radiation therapy for prostate cancer and to assess for factors correlated with rectal dose reduction. Methods and Materials: Fifty-two patients at 4 institutions were enrolled into a prospective pilot clinical trial. Patients underwent baseline scans and then were injected with perirectal spacing hydrogel and rescanned. Intensity modulated radiation therapy plans were created on both scans for comparison. The objectives were to establish rates of creation of ≥7.5 mm of prostate-rectal separation, and decrease in rectal V70 of ≥25%. Multiple regression analysis was performed to evaluate the associations between preinjection and postinjection changes in rectal V70 and changes in plan conformity, rectal volume, bladder volume, bladder V70, planning target volume (PTV), and postinjection midgland separation, gel volume, gel thickness, length of PTV/gel contact, and gel left-to-right symmetry. Results: Hydrogel resulted in ≥7.5-mm prostate-rectal separation in 95.8% of patients; 95.7% had decreased rectal V70 of ≥25%, with a mean reduction of 8.0 Gy. There were no significant differences in preinjection and postinjection prostate, PTV, rectal, and bladder volumes. Plan conformities were significantly different before versus after injection (P=.02); plans with worse conformity indexes after injection compared with before injection (n=13) still had improvements in rectal V70. In multiple regression analysis, greater postinjection reduction in V70 was associated with decreased relative postinjection plan conformity (P=.01). Reductions in V70 did not significantly vary by institution, despite significant interinstitutional variations in plan conformity. There were no significant relationships between reduction in V70 and the other characteristics analyzed. Conclusions: Injection of hydrogel into the prostate-rectal interface resulted in dose reductions to rectum for >90% of patients treated. Rectal sparing was statistically significant across a range of 10 to 75 Gy and was demonstrated within the presence of significant interinstitutional variability in plan conformity, target definitions, and injection results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unexpected effects of inorganic phosphate glass on crystallization and thermo-rheological behavior of polyethylene terephthalate

The effects of ultra-low glass transition temperature (T g ) phosphate glass (Pglass) on the thermal, morphological, rheological, mechanical, and crystallization properties of hybrid Pglass/poly(eththylene terephthalate)(PET) were investigated. Nano- and micro-scale distribution of the Pglass in the PET polymer matrix was observed. The polydispersed Pglass in the PET matrix functioned as a nucleation agent, resulting in increasing crystallization temperature. The Pglass in the PET matrix decreased the T g , indicating a plasticizing effect of the Pglass in the hybrids that was confirmed by the significantly decreased complex viscosity of the PET matrix. In addition, with increasing temperature, a non-terminal behavior of the viscoelastic properties occurred due to the hybrid structural changes and improved miscibility of the hybrid components. In conclusion, the obtained solid-state variable temperature 31 P and 1 H NMR spectroscopy results showed strong Pglass concentration dependency of the interactions at the PET-Pglass interface.

36 MATERIALS SCIENCE↗

Influence of Pore Length on Hydrogenolysis of Polyethylene within a Mesoporous Support Architecture

Due to the plastic waste crisis, selective chemical upcycling of polyolefins into value-added products is a topic of intense interest, demanding polymer deconstruction processes that afford control over the product chain lengths. Recently, a catalytic architecture was synthesized in which a polyolefin melt infiltrates a porous support, and its chains are cleaved by a metal nanoparticle catalyst at the bottom of the pores, yielding a narrow distribution of alkane products. Although the influence of various parameters of these catalytic materials, including the effects of the nanoparticle size and pore diameter on product chain length, has been examined before, here, we investigate the role of the pore length in the cleavage process through the first study that combines catalytic hydrogenolysis and coarse-grained modeling to gain insights not available by experiment alone. We show that the pore length can permit control over the average product length with qualitative agreement between experiment and simulation. In conclusion, we go beyond this observation to uncover the dynamic phenomenon responsible for the pore-length dependence of the cleavage products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Morphology Development in Model Polyethylene via Two-Dimensional Correlation Analysis

Two-dimensional (2D) correlation analysis is applied to synchrotron X-ray scattering data to characterize morphological regimes during nonisothermal crystallization of a model ethylene copolymer (hydrogenated polybutadiene, HPBD). The 2D correlation patterns highlight relationships among multiple characteristics of structure evolution, particularly the extent to which separate features change simultaneously versus sequentially. By visualizing these relationships during cooling, evidence is obtained for two separate physical processes occurring in what is known as 'irreversible crystallization' in random ethylene copolymers. Initial growth of primarily lamellae into unconstrained melt ('primary-irreversible crystallization') is distinguished from subsequent secondary lamellae formation in the constrained, noncrystalline regions between the primary lamellae ('secondary-irreversible crystallization'). At successively lower temperatures ('reversible crystallization'), growth of the crystalline reflections is found to occur simultaneously with the change in shape of the amorphous halo, which is inconsistent with the formation of an additional phase. Rather, the synchronous character supports the view that growth of frustrated crystals distorts the adjacent noncrystalline material. Furthermore, heterocorrelation analysis of small-angle and wide-angle X-ray scattering data from the reversible crystallization regime reveals that the size of new crystals is consistent with fringed-micellar structures (9 nm). Thus, 2D correlation analysis provides new insights into morphology development in polymeric systems.

36 MATERIALS SCIENCE↗

Thermal Behaviour of W+C Ion Implanted Ultra High Molecular Weight Polyethylene (UHMWPE)

The aim of this work was to examine thermal behavior of the surface modified Ultra High Molecular Weight Poly Ethylene (UHMWPE ) in order to understand the effect of ion implantation on the properties of this polymer which is widely used especially for biomedical applications. UHMWPE samples were Tungsten and Carbon (W+C) hybrid ion implanted by using Metal Vapour Vacuum Arc (MEVVA) ion implantation technique with a fluence of 10 17 ions/cm2 and extraction voltage of 30 kV. Untreated and surface-treated samples were investigated by Rutherford Back Scattering (RBS) Analysis, Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) Spectrometry, Thermo Gravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC). This study has shown that ion implantation represents a powerful tool on modifying thermal properties of UHMWPE surfaces. This combination of properties can make implanted UHMWPE a preferred material for biomedical applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radon Diffusion Measurement in Polyethylene based on Alpha Detection

We present a method to measure the diffusion of Radon in solid materials based on the alpha decay of the radon daughter products. In contrast to usual diffusion measurements which detect the radon that penetrates a thin barrier, we let the radon diffuse into the material and then measure the alpha decays of the radon daughter products in the material. We applied this method to regular and ultra high molecular weight poly ethylene and find diffusion lengths of order of mm as expected. However, the preliminary analysis shows significant differences between two different approaches we have chosen. These differences may be explained by the different experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of ionic liquids on cation dynamics in amorphous polyethylene oxide electrolytes

We perform extensive molecular dynamics simulations of a poly(ethylene oxide)-based polymer electrolyte material containing lithium bis(trifluoromethanesulfonyl)imide salt for a wide temperature regime above and below the experimental crystallization temperature with and without N-methyl-N-propylpyrrolidinium bis(trifluoromethanesulfonyl)imide ionic liquid (IL). The impact of the IL-concentration on the cation dynamics is studied. The increase of the cation mobility upon addition of IL is significant but temperature-independent. This can be related to distinct variations of the underlying transport properties as expressed within the previously introduced transport model of polymer electrolytes. Even for the largest IL concentration the transport model perfectly predicts the non-trivial time-dependence of the cationic mean square displacement for all temperatures. Finally, we compare our numerical and theoretical findings with the results of recent nuclear magnetic resonance experiments. In this way we can exclusively relate the strong experimentally observed dependence of the low-temperature Li-diffusivity on the IL concentration to the impact of IL on crystallization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient barrier for charge injection in polyethylene by silver nanoparticles/plasma polymer stack

Charge injection from a metal/insulator contact is a process promoting the formation of space charge in polymeric insulation largely used in thick layers in high voltage equipment. The internal charge perturbs the field distribution and can lead to catastrophic failure either through its electrostatic effects or through energetic processes initiated under charge recombination and/or hot electrons effects. Injection is still ill-described in polymeric insulation due to the complexity of the contact between the polymer chains and the electrodes. Barrier heights derived from the metal work function and the polymer electronic affinity do not provide a good description of the measurements [Taleb et al., IEEE Trans. Dielectr. Electr. Insul. 20, 311–320 (2013)]. Considering the difficulty to describe the contact properties and the need to prevent charge injection in polymers for high voltage applications, we developed an alternative approach by tailoring the interface properties by the silver nanoparticles (AgNPs)/plasma polymer stack, deposited on the polymer film. Due to their small size, the AgNPs, covered by a very thin film of plasma polymer, act as deep traps for the injected charges thereby stabilizing the interface from the point of view of charge injection. After a quick description of the method for elaborating the nanostructured layer near the contact, it is demonstrated how the AgNPs/plasma polymer stack effectively prevents, in a spectacular way, the formation of bulk space charge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗