Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photonic devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Enhancement of Photoemission on p-Type GaAs Using Surface Acoustic Waves

We demonstrate that photoemission properties of p-type GaAs can be altered by surface acoustic waves (SAWs) generated on the GaAs surface due to dynamical piezoelectric fields of SAWs. Multiphysics simulations indicate that charge-carrier recombination is greatly reduced, and electron effective lifetime in p-doped GaAs may increase by a factor of 10× to 20×. It implies a significant increase, by a factor of 2× to 3×, of quantum efficiency (QE) for GaAs photoemission applications, like GaAs photocathodes. Conditions of different SAW wavelengths, swept SAW intensities, and varied incident photon energies were investigated. Essential steps in SAW device fabrication on a GaAs substrate are demonstrated, including deposition of an additional layer of ZnO for piezoelectric effect enhancement, measurements of current–voltage (I–V) characteristics of the SAW device, and ability to survive high-temperature annealing. Results obtained and reported in this study provide the potential and basis for future studies on building SAW-enhanced photocathodes, as well as other GaAs photoelectric applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Review of high speed communications photomultiplier detectors

Four types of newly developed high speed photomultipliers are discussed: all electrostatic; static crossed field; dynamic crossed field; and hybrid (EBS). Design, construction, and performance parameters of each class are presented along with limitations of each class of device and prognosis for its future in high speed light detection. The particular advantage of these devices lies in high speed applications using low photon flux, large cathode areas, and broadband optical detection.

Enck, R. S.↗

Novel Techniques for Millimeter-Wave Packages

A new millimeter-wave package architecture with supporting electrical, mechanical and material science experiment and analysis is presented. This package is well suited for discrete devices, monolithic microwave integrated circuits (MMIC's) and multichip module (MCM) applications. It has low-loss wide-band RF transitions which are necessary to overcome manufacturing tolerances leading to lower per unit cost Potential applications of this new packaging architecture which go beyond the standard requirements of device protection include integration of antennas, compatibility to photonic networks and direct transitions to waveguide systems. Techniques for electromagnetic analysis, thermal control and hermetic sealing were explored. Three dimensional electromagnetic analysis was performed using a finite difference time-domain (FDTD) algorithm and experimentally verified for millimeter-wave package input and output transitions. New multi-material system concepts (AlN, Cu, and diamond thin films) which allow excellent surface finishes to be achieved with enhanced thermal management have been investigated. A new approach utilizing block copolymer coatings was employed to hermetically seal packages which met MIL STD-883.

Herman, Martin I.↗

Physics of Hard Spheres Experiment: Significant and Quantitative Findings Made

Direct examination of atomic interactions is difficult. One powerful approach to visualizing atomic interactions is to study near-index-matched colloidal dispersions of microscopic plastic spheres, which can be probed by visible light. Such spheres interact through hydrodynamic and Brownian forces, but they feel no direct force before an infinite repulsion at contact. Through the microgravity flight of the Physics of Hard Spheres Experiment (PHaSE), researchers have sought a more complete understanding of the entropically driven disorder-order transition in hard-sphere colloidal dispersions. The experiment was conceived by Professors Paul M. Chaikin and William B. Russel of Princeton University. Microgravity was required because, on Earth, index-matched colloidal dispersions often cannot be density matched, resulting in significant settling over the crystallization period. This settling makes them a poor model of the equilibrium atomic system, where the effect of gravity is truly negligible. For this purpose, a customized light-scattering instrument was designed, built, and flown by the NASA Glenn Research Center at Lewis Field on the space shuttle (shuttle missions STS 83 and STS 94). This instrument performed both static and dynamic light scattering, with sample oscillation for determining rheological properties. Scattered light from a 532- nm laser was recorded either by a 10-bit charge-coupled discharge (CCD) camera from a concentric screen covering angles of 0 to 60 or by sensitive avalanche photodiode detectors, which convert the photons into binary data from which two correlators compute autocorrelation functions. The sample cell was driven by a direct-current servomotor to allow sinusoidal oscillation for the measurement of rheological properties. Significant microgravity research findings include the observation of beautiful dendritic crystals, the crystallization of a "glassy phase" sample in microgravity that did not crystallize for over 1 year in 1g (Earth's gravity), and the emergence of face-centered-cubic (FCC) crystals late in the coarsening process (as small crystallites lost particles to the slow ripening of large crystallites). Significant quantitative findings from the microgravity experiments have been developed describing complex interactions among crystallites during the growth process, as concentration fields overlap in the surrounding disordered phase. Time-resolved Bragg scattering under microgravity captures one effect of these interactions quite conclusively for the sample at a volume fraction of 0.528. From the earliest time until the sample is almost fully crystalline, the size and overall crystallinity grow monotonically, but the number of crystallites per unit volume (number density) falls. Apparently nucleation is slower than the loss of crystallites because of the transfer of particles from small to large crystals. Thus, coarsening occurs simultaneously with growth, rather than following the completion of nucleation and growth as is generally assumed. In the same sample, an interesting signature appears in the apparent number density of crystallites and the volume fraction within the crystallites shortly before full crystallinity is reached. A brief upturn in both indicates the creation of more domains of the size of the average crystallite simultaneous with the compression of the crystallites. Only the emergence of dendritic arms offers a reasonable explanation. The arms would be "seen" by the light scattering as separate domains whose smaller radii of curvature would compress the interior phase. In fiscal year 1999, numerous papers, a doctoral dissertation, and the PHaSE final report were produced. Although this flight project has been completed, plans are in place for a follow-on colloid experiment by Chaikin and Russel that employs a light microscope within Glenn's Fluids and Combustion Facility on the International Space Station. PHaSE is providing us with a deeper understanding of the nure of phase transitions. The knowledge derived has added to the understanding of condensed matter. In addition, the burgeoning study of the dynamics of colloidal self-assembly may lead to the development of a range of photonic materials that control the desirable properties of light. Thus, applications of ordered colloidal structures include not only ultrastructure ceramics, but also photonic crystals and photothermal nanosecond light-switching devices. Industries dealing with semiconductors, electro-optics, ceramics, and composites stand to benefit from such advancements.

Doherty, Michael P.↗

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

We have obtained the first data on the multiplexed operation of titanium hot-electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far-infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (approximately microseconds at 300-400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per ??/2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near- IR photons (1550 nm) with a time constant of 3.5 ?s. Follow-on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

microwave readout↗

Calibration of the SHERLOC Deep Ultraviolet Fluorescence–Raman Spectrometer on the Perseverance Rover

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA’s Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (200 cm1 to 12, 000 cm1) (with a spectral resolution of 0.296 nm (40 cm1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

Kyle Uckert↗

Achieving Single-Electron Sensitivity at Enhanced Speed in Fully-Depleted CCDs with Double-Gate MOSFETs

We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating sub-electron readout noise in one pixel charge measurement. We have also demonstrated the non-destructive readout capability of the device. Achieving single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of a small number of samples. We have demonstrated fully-depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least six times the speed of floating gate amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heat Capacity and Thermal Conductance Measurements of a Superconducting-Normal Mixed State by Detection of Single 3 eV Photons in a Magnetic Penetration Thermometer

We report on measurements of the detected signal pulses in a molybdenum-gold Magnetic Penetration Thermometer (MPT) in response to absorption of one or more 3 eV photons. We designed and used this MPT sensor for x-ray microcalorimetry. In this device, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons, and responsivity is enhanced by a Meissner transition in which the magnetic flux penetrating the sensor changes rapidly to minimize free energy in a mixed superconducting normal state. We have previously reported on use of our MPT to study a thermal phonon energy loss to the substrate when absorbing x-rays. We now describe results of extracting heat capacity C and thermal conductance G values from pulse height and decay time of MPT pulses generated by 3 eV photons. The variation in C and G at temperatures near the Meissner transition temperature (set by an internal magnetic bias field) allow us to probe the behavior in superconducting normal mixed state of the condensation energy and the electron cooling power resulting from quasi-particle recombination and phonon emission. The information gained on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

superconductivity↗

Direct probing of strong magnon–photon coupling in a planar geometry

We demonstrate direct probing of strong magnon–photon coupling using Brillouin light scattering (BLS) spectroscopy in a planar geometry. The magnonic hybrid system comprises a split-ring resonator loaded with epitaxial yttrium iron garnet thin films of 200 nm and 2.46 μm thickness. Here, the BLS measurements are combined with microwave spectroscopy measurements where both biasing magnetic field and microwave excitation frequency are varied. The cooperativity for the 200 nm-thick YIG films is 1.1, and larger cooperativity of 29.1 is found for the 2.46 μm-thick YIG film. We show that BLS is advantageous for probing the magnonic character of magnon–photon polaritons, while microwave absorption is more sensitive to the photonic character of the hybrid excitation. A miniaturized, planar device design is imperative for the potential integration of magnonic hybrid systems in future coherent information technologies, and our results are a first stepping stone in this regard. Furthermore, successfully detecting the magnonic hybrid excitation by BLS is an essential step for the up-conversion of quantum signals from the microwave to the optical regime in hybrid quantum systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave-Based Quantum Control and Coherence Protection of Tin-Vacancy Spin Qubits in a Strain-Tuned Diamond-Membrane Heterostructure

Robust spin-photon interfaces in solids are essential components in quantum networking and sensing technologies. Ideally, these interfaces combine a long-lived spin memory, coherent optical transitions, fast and high-fidelity spin manipulation, and straightforward device integration and scaling. The tin- vacancy center (SnV) in diamond is a promising spin-photon interface with desirable optical and spin properties at 1.7 K. However, the SnV spin lacks efficient microwave control, and its spin coherence degrades with higher temperature. In this work, we introduce a new platform that overcomes these challenges—SnV centers in uniformly strained thin diamond membranes. The controlled generation of crystal strain introduces orbital mixing that allows microwave control of the spin state with 99.36(9)% gate fidelity and spin coherence protection beyond a millisecond. Moreover, the presence of crystal strain suppresses temperature-dependent dephasing processes, leading to a considerable improvement of the coherence time up to 223(10) μs at 4 K, a widely accessible temperature in common cryogenic systems. Critically, the coherence of optical transitions is unaffected by the elevated temperature, exhibiting nearly lifetime-limited optical linewidths. Combined with the compatibility of diamond membranes with device integration, the demonstrated platform is an ideal spin-photon interface for future quantum technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multifunctional Superconducting Nanowire Quantum Sensors

Superconducting nanowire single-photon detectors (SNSPDs) offer high-quantum-efficiency and low-dark-count-rate single-photon detection. In a growing number of cases, large magnetic fields are being incorporated into quantum microscopes, nanophotonic devices, and sensors for nuclear and high-energy physics that rely on SNSPDs, but superconducting devices generally perform poorly in large magnetic fields. Here, we demonstrate robust performance of amorphous SNSPDs in magnetic fields of up to ±6 T with a negligible dark-count rate and unchanged quantum efficiency at typical bias currents. Critically, we also show that the SNSPD can be used as a magnetometer with a sensitivity of better than 100μT/√Hz and as a thermometer with a sensitivity of 20μK/√Hz at 1 K. Thus, a single-photon detector integrated into a quantum device can be used as a multifunctional quantum sensor capable of describing the temperature and magnetic field on chip simply by varying the bias current to change the operating modality from single-photon detection to thermometry or magnetometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Photonic Curing Enabling High-Speed Processing for Perovskite Solar Cells

The thermal annealing step is the bottleneck to high-throughput manufacturing of perovskite solar cells. In this work, we investigate photonic curing to replace thermal annealing for the sol gel NiO hole transport layer. Using solar cell device current density-voltage performance as a metric, we compare the effects of thermal annealing and photonic curing on the conversion of sol gel NiO films deposited on top of indium tin oxide coated Willow® glass substrates. The significant reduction in processing time validates photonic curing as the enabling tool for high-speed manufacturing.

Xu, Weijie↗

Simultaneous type-I and type-II phase matching for second-order nonlinearity in integrated lithium niobate waveguide

Second-order optical nonlinearity is widely used for both classical and quantum photonic applications. Due to material dispersion and phase matching requirements, the polarization of optical fields is pre-defined during the fabrication. Only one type of phase matching condition is normally satisfied, and this limits the device flexibility. Here, we demonstrate that phase matching for both type-I and type-II second-order optical nonlinearity can be realized simultaneously in the same waveguide fabricated from thin-film lithium niobate. This is achieved by engineering the geometry dispersion to compensate for the material dispersion and birefringence. The simultaneous realization of both phase matching conditions is verified by the polarization dependence of second-harmonic generation. Correlated photons are also generated through parametric down conversion from the same device. This work provides a novel approach to realize versatile photonic functions with flexible devices.

Briggs, Ian↗

Material-dependent photon ionizing radiation effects in Si and GaAs PIN diodes: A numerical investigation

We present a finite-element drift-diffusion-Poisson model in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework to compare the radiation response of silicon (Si) and gallium arsenide (GaAs) PIN diodes under high-energy photon irradiation. The model solves coupled carrier continuity and Poisson’s equations with Shockley-Read-Hall recombination, and is verified against standard analytical J-V behavior. Using a simplified 1D geometry with ideal Ohmic contacts, we quantify device response under forward and reverse bias with a 100 MeV photon flux. Under forward bias, Si exhibits markedly greater radiation sensitivity than GaAs, including larger increases in current density, stronger local field and carrier-product perturbations, and higher recombination. Under reverse bias, GaAs shows larger radiation-induced photocurrent and broader current-density peaks near junctions, indicating an advantage for photodetection. Integrated steady-state recombination is consistently higher in Si across voltages. Under periodic photon pulses, GaAs produces higher-amplitude photoresponse and settles more rapidly than Si. These results highlight material-dependent trade-offs for radiation-tolerant, high-speed optoelectronics and provide guidance for selecting PIN architectures in aerospace, nuclear, and high-energy physics environments.

36 MATERIALS SCIENCE↗

Imaging techniques in X-ray astronomy.

Some of the imaging problems encountered in space-borne X-ray astronomy are reviewed, along with the techniques considered for their solution. Following a discussion of X-ray focussing and X-ray image processing, the development of X-ray imaging devices is surveyed. It is shown that the imaging devices that will be used in X-ray astronomy will take advantage of developments intended for infrared and optical astronomy. The special requirements of X-ray observation - especially, single photon detection and high time resolution - rule out the use of existing devices, particularly because of readout problems.

Gursky, H.↗