Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Exploration Portable Life Support System Hatch Component Design

The design for the Exploration Extravehicular Mobility Unit (xEMU) is continuously being developed and many previous gaps in technologies have begun initial development. Various Exploration Portable Life Support System (xPLSS) Hatch components had been at a stall in technology development for many years including the Feedwater Supply Assembly, Trace Contaminant Control System, and the thermal loop filters. The challenging requirements and initial design of these components were previously discussed in “Exploration Portable Life Support System Hatch Component Design Challenges and Progress”. NASA has plans to go back to the Moon. The development of each of these components is relevant not only to the xEMU, but also to the International Space Station, Gateway, and commercial space businesses. As the xPLSS is being designed, built, integrated, and tested at the NASA Johnson Space Center, technology solutions will have a direct incorporation path as the xPLSS is matured to meet design and performance goals. This is a follow on paper to discuss the initial implementation of the hatch component designs, changes due to existing challenges, and performance results of these components as the xEMU project completes the first phase of towards flight, known as Design Verification Test (DVT).

Kristina Todd↗

Determination of Chlorophyll Content in Selected Grass Communities of Krkonoše Mts. Tundra Based on Laboratory Spectroscopy and Aerial Hyperspectral Data

The study focuses on the determination of chlorophyll content in four prevailing grasses in the relict arctic-alpine tundra located in the Krkonoše Mountains National Park, Czech Republic. We compared two methods for determination of leaf chlorophyll content (LCC) – spectrophotometric determination in the laboratory, and the LCC assessed by fluorescence portable chlorophyll meter CCM-300. Relationships were established between the LCCs and vegetation indices calculated from leaf spectra acquired with contact probe coupled with an ASD FieldSpec4 Wide-Res spectroradiometer. Canopy chlorophyll contents (CCC) were computed from the LCCs and green leaf area index (LAI), and modelled based on the field spectra measured by the spectroradiometer and the hyperspectral images acquired by Headwall Nano-Hyperspec® mounted on the DJI Matrice 600 Pro drone. The calculations are performed on datasets acquired in June, July and August 2020 together and separately for species and months. In general, the correlations based on June datasets work the best at both levels: median R 2 for all indices was 0.52 for all species together at leaf level and median R 2 = 0.47 at the canopy level (vegetation indices computed from field spectra). Canopy chlorophyll content map was created based on the results of stepwise multiple linear regression. The R 2 was 0.42 when using four wavelengths from the red and red edge spectral region. We attribute the weak model performance to a combination of several factors: leaf structure may bias LCC from laboratory measurements, effects of LAI variability on CCC, and the sampling design, probably not covering the whole phenology equally for all studied species.

L. Cervena↗

A quasioptical resonant-tunneling-diode oscillator operating above 200 GHz

We have fabricated and characterized a quasioptically stabilized resonant-tunneling-diode (RTD) oscillator having attractive performance characteristics for application as a radiometric local oscillator. The fundamental frequency of the oscillator is tunable from about 200 to 215 GHz, the instantaneous linewidth is between 10 and 20 kHz, and the output power across the tuning band is about 50 micro-W. The narrow linewidth and fine tuning of the frequency are made possible by a scanning semiconfocal open cavity which acts as the high-Q resonator for the oscillator. The cavity is compact, portable, and insensitive to vibration and temperature variation. The total dc power consumption (RTD plus bias supply) is only 10 mW. The present oscillator provides the highest power obtained to date from an RTD above 200 GHz. We attribute this partly to the use of the quasioptical resonator, but primarily to the quality of the RTD. It is fabricated from the In(0.53)Ga(0.47)As/AlAs materials system, which historically has yielded the best overall resonant-tunneling characteristics of any material system. The RTD active area is 4 sq microns, and the room-temperature peak current density and peak-to-valley current ratio are 2.5x10(exp 5) A cm(exp -2) and 9, respectively. The RTD is mounted in a WR-3 standard-height rectangular waveguide and is contacted across the waveguide by a fine wire that protrudes through a via hole in a Si3N4 'honeycomb' overlayer. We estimate that the theoretical maximum frequency of oscillation of this RTD is approximately 1.1 THz, and that scaled-down versions of the same quasioptical oscillator design should operate in a fundamental mode up to frequencies of at least 500 GHz.

Brown, E. R.↗

Spectrum Preprocessing in the OPAD System

To determine the readiness of a rocket engine, and facilitate decisions on continued use of the engine before servicing is required, high-resolution optical spectrometers are used to acquire spectra from the exhaust plume. Such instruments are in place at the Technology Test Bed (TTB) stand at Marshall Space Flight Center (MSFC) and the A1 stand at Stennis Space Center (SSC). The optical spectrometers in place have a wide wavelength range covering the visible and near-infrared regions, taking approximately 8000 measurements at about one Angstrom spacing every half second. In the early stages of this work, data analysis was done manually. A simple spectral model produced a theoretical spectrum for given amount of elements and an operator visually matched the theoretical and real spectra. Currently, extensive software is being developed to receive data from the spectrometer and automatically generate an estimate of element amounts in the plume. It will result in fast and reliable analysis, with the capability of real-time performance. This software is the result of efforts of several groups but mainly it has been developed and used by scientists and combustion engineers, in their effort of understanding the underlying physical processes and phenomena and creating visualization and report generation facilities. Most of the software has been developed using the IDL language and programming environment which allows for extensive data visualization. Although this environment has been very beneficial, the resulting programs execute very slowly and are not easily portable to more popular, real-time environments. The need for portability and high speed of execution is becoming more apparent as the software matures moving out of the experimentation stage and into the production stage where ease of use and short response time are the most desirable features. The purpose of the work described here is to assist the scientists who developed the original IDL-based version in the conversion of the software into the real-time, production version. Specifically, a section of the software devoted to the preprocessing of the spectra has been converted into the C language. In addition, parts of this software which may be improved have been identified, and recommendations are given to improve the functionality and ease of use of the new version.

Katsinis, Constantine↗

Fuzzification of Electromagnetic Interference Patterns Onboard Commercial Airliners Due to Wireless Technology

The use of portable wireless technology has increased dramatically over the past few years. Over the years however, numerous reports have cited portable electronic devices (PEDs) as a possible cause of electromagnetic interference (EMI) to aircraft navigation and communication radio systems. PEDs may act as transmitters and their signals may be detected by the various radio receiver antennas installed on the aircraft. Measurement of the radiated field coupling between passenger cabin locations and aircraft communication and navigation receivers, via their antennas is defined herein as interference path loss (IPL). Personnel from NASA Langley Research Center, Eagles Wings Inc., and United Airlines performed extensive IPL measurements on several Boeing 737 airplanes. In previous work, the IPL data collected was graphically plotted and presented using MATLAB. This paper provides an introductory result of modeling EMI patterns using Fuzzy Logic, using the graphical analysis of the IPL data summarized. The application of fuzzy logic seeks to provide a means of estimating IPL at various locations within an airplane passenger cabin using simple modeling parameters. Fuzzy logic methods may provide a means to assess IPL characteristics of aircraft that have not been subject to expensive measurement or modeling processes and may also be useful for estimating the merit of aircraft design changes intended to minimize the potential for EMI.

Jafri, Madiha↗

NASA Tech Briefs, November 2007

Topics include: Wireless Measurement of Contact and Motion Between Contact Surfaces; Wireless Measurement of Rotation and Displacement Rate; Portable Microleak-Detection System; Free-to-Roll Testing of Airplane Models in Wind Tunnels; Cryogenic Shrouds for Testing Thermal-Insulation Panels; Optoelectronic System Measures Distances to Multiple Targets; Tachometers Derived From a Brushless DC Motor; Algorithm-Based Fault Tolerance for Numerical Subroutines; Computational Support for Technology- Investment Decisions; DSN Resource Scheduling; Distributed Operations Planning; Phase-Oriented Gear Systems; Freeze Tape Casting of Functionally Graded Porous Ceramics; Electrophoretic Deposition on Porous Non- Conductors; Two Devices for Removing Sludge From Bioreactor Wastewater; Portable Unit for Metabolic Analysis; Flash Diffusivity Technique Applied to Individual Fibers; System for Thermal Imaging of Hot Moving Objects; Large Solar-Rejection Filter; Improved Readout Scheme for SQUID-Based Thermometry; Error Rates and Channel Capacities in Multipulse PPM; Two Mathematical Models of Nonlinear Vibrations; Simpler Adaptive Selection of Golomb Power-of- Two Codes; VCO PLL Frequency Synthesizers for Spacecraft Transponders; Wide Tuning Capability for Spacecraft Transponders; Adaptive Deadband Synchronization for a Spacecraft Formation; Analysis of Performance of Stereoscopic-Vision Software; Estimating the Inertia Matrix of a Spacecraft; Spatial Coverage Planning for Exploration Robots; and Increasing the Life of a Xenon-Ion Spacecraft Thruster.

Source record↗

Analysis of Thick Sandwich Shells with Embedded Ceramic Tiles

The Composite Armored Vehicle (CAV) is an advanced technology demonstrator of an all-composite ground combat vehicle. The CAV upper hull is made of a tough light-weight S2-glass/epoxy laminate with embedded ceramic tiles that serve as armor. The tiles are bonded to a rubber mat with a carefully selected, highly viscoelastic adhesive. The integration of armor and structure offers an efficient combination of ballistic protection and structural performance. The analysis of this anisotropic construction, with its inherent discontinuous and periodic nature, however, poses several challenges. The present paper describes a shell-based 'element-layering' technique that properly accounts for these effects and for the concentrated transverse shear flexibility in the rubber mat. One of the most important advantages of the element-layering technique over advanced higher-order elements is that it is based on conventional elements. This advantage allows the models to be portable to other structural analysis codes, a prerequisite in a program that involves the computational facilities of several manufacturers and government laboratories. The element-layering technique was implemented into an auto-layering program that automatically transforms a conventional shell model into a multi-layered model. The effects of tile layer homogenization, tile placement patterns, and tile gap size on the analysis results are described.

Davila, Carlos G.↗

Ultrasonic Nondestructive Evaluation Techniques Applied to the Quantitative Characterization of Textile Composite Materials

In this Progress Report, we describe our further development of advanced ultrasonic nondestructive evaluation methods applied to the characterization of anisotropic materials. We present images obtained from experimental measurements of ultrasonic diffraction patterns transmitted through water only and transmitted through water and a thin woven composite. All images of diffraction patterns have been included on the accompanying CD-ROM in the JPEG format and Adobe TM Portable Document Format (PDF), in addition to the inclusion of hardcopies of the images contained in this report. In our previous semi-annual Progress Report (NAG 1-1848, December, 1996), we proposed a simple model to simulate the effect of a thin woven composite on an insonifying ultrasonic pressure field. This initial approach provided an avenue to begin development of a robust measurement method for nondestructive evaluation of anisotropic materials. In this Progress Report, we extend that work by performing experimental measurements on a single layer of a five-harness biaxial woven composite to investigate how a thin, yet architecturally complex, material interacts with the insonifying ultrasonic field. In Section 2 of this Progress Report we describe the experimental arrangement and methods for data acquisition of the ultrasonic diffraction patterns upon transmission through a thin woven composite. We also briefly describe the thin composite specimen investigated. Section 3 details the analysis of the experimental data followed by the experimental results in Section 4. Finally, a discussion of the observations and conclusions is found in Section 5.

Miller, James G.↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning from Long-Duration Spaceflight

Due to the deconditioned state of crewmembers in the initial hours after landing, it is safer and more practical to perform a vision test while seated in a chair versus walking on a treadmill. The purpose of this study was to validate the ability of a manually operated oscillating chair to produce the oscillatory frequency and displacement equivalent of walking on a treadmill at a 4 mph pace. A fast Fourier transform (FFT)was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. Peak oscillation frequencies achieved with the manual chair were lower and more variable than those of treadmill walking and the automatic chair. This can mostly be attributed to operator fatigue. However, DVA scores across conditions were not significantly different, indicating that the manual chair can provide adequate vertical oscillation frequency and displacement with the added advantage of being portable enough for testing outside a laboratory. Furthermore the automatic chair very closely matches the oscillation frequency of treadmill walking, making it an ideal method for testing DVA in a laboratory setting.

Kreutzberg, G. A.↗

Airborne Visible/Infrared Imaging Spectrometer 3 (AVIRIS-3)

The Airborne Visible/Infrared Imaging Spectrometer 3 (AVIRIS-3) is the third of the NASA AVIRIS spectrometer series and is being developed in parallel with the Compact Wide-swath Imaging Spectrometer II (CWIS-II) for the University of Zurich, Switzerland. The core spectrometer of AVIRIS-3 is a copy of the optically fast, F/1.8 Dyson imaging spectrometer used by the Earth Surface Mineral Dust Source Investigation (EMIT) that is in development and scheduled for launch to the International Space Station (ISS) in 2022. AVIRIS-3 is intended to provide state-of-the-art imaging spectroscopy measurements for NASA science and application through the next decade and beyond. AVIRIS-3 uses the EMIT spectrometer design interfaced with a scaled two mirror telescope enclosed in a portable vacuum vessel to enable measurements from airborne platforms ranging from a Twin Otter to a business jet or a NASA ER-2. AVIRIS-3 is a cryogenic instrument with advanced system control and real-time onboard spectroscopic data processing algorithms evolved from AVIRIS-NG. The spectral range of AVIRIS-3 is 380 to 2500 nm with 7.4 nm sampling. The radiometric range is from 0 to max terrestrial Lambertian radiance with higher signal-to-noise ratio performance than AVIRIS-Classic or AVIRIS-Next Generation. The spatial field-of-view is 39.5 degrees with 0.56 milliradian sampling. This paper describes the design and development of AVIRIS-3 and presents its characteristics in comparison to the previous generation imaging spectrometers.

Helmlinger, Mark↗

Flexible Foam Protection Materials for Constellation Space Suit Element Portable Life Support Subsystem Packaging Study

This paper discusses the effort in evaluating and selecting a light weight impact protection material for the Constellation Space Suit Element (CSSE) Portable Life Support Subsystem (PLSS) conceptual packaging study. A light weight material capable of holding and protecting the components inside the PLSS is required to demonstrate the viability of the flexible PLSS packaging concept. The material needs to distribute, dissipate, and absorb the impact energy of the PLSS falling on the lunar surface. It must also be very robust and function in the extreme lunar thermal vacuum environment for up to one hundred Extravehicular Activity (EVA) missions. This paper documents the performance requirements for selecting a foam protection material, and the methodologies for evaluating commercial off-the-shelf (COTS) foam protection materials. It also presents the materials properties test results and impact drop test results of the various foam materials evaluated in the study. The findings from this study suggest that a foam based flexible protection system is a viable solution for PLSS packaging. However, additional works are needed to optimize COTS foam properties or to develop a composite foam system that will meet all the performance requirements for the CSSE PLSS flexible packaging.

Tang, Henry H.↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Portable, Low-Cost, Column Carbon Dioxide and Methane Measurements for Validating Satellite Observations in Remote Locations

We present a low-cost (~$10K per instrument), portable solution to ground-based validation of satellite observations for difficult to reach locations with precisions of 1 ppm XCO2 and 10 ppb XCH4 for hourly data products. While Total Carbon Column Observing Network (TCCON) is the gold-standard for ground validation, there are locations where a ground column validation data point would be useful but conditions are not conducive to a permanent station. Examples include wetlands, thawing permafrost, the tropics, the Amazon, sub-Saharan Africa, as well as locations without a power grid or with geopolitical conflict. In addition, the low-cost and portability mean a geographical region can be studied in depth with multiple instruments. This passive, sun-pointing instrument is a miniaturized, laser heterodyne radiometer (mini-LHR) that has been under development by our team since 2009. It can be operated either in tandem with AERONET (a global network of 500 instruments that measure aerosol optical depth), or as a stand-alone instrument with a low-cost (~$3K), light-weight sun tracker. One of the main benefits of the mini-LHR is that it can quickly reach remote locations and provide a validation measurement even if there is limited or no infrastructure at the site. The instrument weighs ~10 lbs, fits into a backpack, and is powered by two folding solar panels and a battery pack. In clear conditions, the instrument can be set-up in under an hour. Portability means that mini-LHRs can be easily moved for side-by-side comparisons with other mini-LHRs and with TCCON which simplifies assessing instrument bias as well as accuracy. Like TCCON, the mini-LHR points directly at the sun with a narrow field-of-view and is its insensitivity to cloud and aerosol scattering that is common to nadir-pointing passive satellite approaches. Here we present a collection of sample data sets to demonstrate performance from locations that vary in climate, altitude, solar zenith angle, hours of sun per day, etc., as well as data from side-by-side TCCON comparisons. Retrievals of CO2 and CH4 were completed using the NASA/Goddard's Planetary Spectrum Generator (PSG) that incorporates meteorological inputs from Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) data set.

Wilson, Emily W.↗

A Novel 24 GHz One-Shot, Rapid and Portable Microwave Imaging System

Development of microwave and millimeter wave imaging systems has received significant attention in the past decade. Signals at these frequencies penetrate inside of dielectric materials and have relatively small wavelengths. Thus. imaging systems at these frequencies can produce images of the dielectric and geometrical distributions of objects. Although there are many different approaches for imaging at these frequencies. they each have their respective advantageous and limiting features (hardware. reconstruction algorithms). One method involves electronically scanning a given spatial domain while recording the coherent scattered field distribution from an object. Consequently. different reconstruction or imaging techniques may be used to produce an image (dielectric distribution and geometrical features) of the object. The ability to perform this accurate~v and fast can lead to the development of a rapid imaging system that can be used in the same manner as a video camera. This paper describes the design of such a system. operating at 2-1 GHz. using modulated scatterer technique applied to 30 resonant slots in a prescribed measurement domain.

Ghasr, M. T.↗

Dynamic Isotope Surface Power Systems

The Dynamic Isotope Power Systems (DIPS) demonstration program, sponsored by the U.S. Department of Energy (DOE) with support funding from the National Aeronautics and Space Administration (NASA), is currently focused on the development of a standardized 2.5 kWe portable generator for multiple applications on the lunar or Martian surface. A variety of potential remote and mobile applications has been identified by NASA including surface rovers for both short and extended duration missions, remote power to science packages, and backup to central base power. Recent work focused on refining the 2.5 kWe design including assessing compatibility with the Martian environment to assure the design is suitable while imposing only a minor mass penalty on lunar operations. Additional work included a study performed to compare the DIPS with regenerative fuel cell systems for lunar mobile and remote power systems. Power requirements were reviewed and a modular system chosen for the comparison. Finally, a plan and cycle schematic were generated for an early demonstration of a prototypic isotope power Brayton system using the Antarctic as the test bed.

Hunt, Maribeth E.↗

The force on the flex: Global parallelism and portability

A parallel programming methodology, called the force, supports the construction of programs to be executed in parallel by an unspecified, but potentially large, number of processes. The methodology was originally developed on a pipelined, shared memory multiprocessor, the Denelcor HEP, and embodies the primitive operations of the force in a set of macros which expand into multiprocessor Fortran code. A small set of primitives is sufficient to write large parallel programs, and the system has been used to produce 10,000 line programs in computational fluid dynamics. The level of complexity of the force primitives is intermediate. It is high enough to mask detailed architectural differences between multiprocessors but low enough to give the user control over performance. The system is being ported to a medium scale multiprocessor, the Flex/32, which is a 20 processor system with a mixture of shared and local memory. Memory organization and the type of processor synchronization supported by the hardware on the two machines lead to some differences in efficient implementations of the force primitives, but the user interface remains the same. An initial implementation was done by retargeting the macros to Flexible Computer Corporation's ConCurrent C language. Subsequently, the macros were caused to directly produce the system calls which form the basis for ConCurrent C. The implementation of the Fortran based system is in step with Flexible Computer Corporations's implementation of a Fortran system in the parallel environment.

Jordan, H. F.↗

Development of Inspection for Friction Stir Welds for Rocket Fuel Tanks

During development of the Ares I weld processes nondestructive and destructive testing were used to identify and characterize defects that occurred. These defects were named and character noted. This catalogue of defects and characteristics was then used to develop inspection methods for Self Reacting Friction Stir Welds (SR ]FSW) and Conventional Friction Stir Welds (C ]FSW). Dye penetrant, eddy current, x ]radiography, single element ultrasonic, and phased array ultrasonic (PAUT) inspection procedures were developed to target the expected defects. Once the method procedure was developed a comparison was performed to allow for selection of the best inspection method. Tests of the effectiveness of the inspection were performed on purposely fabricated flawed specimens and electrodischarge machined notches. The initial test results prompted a revisit of the PAUT procedure and a redesign of the inspection. Subsequent testing showed that a multi ]angle PAUT inspection resulted in better detection capability. A discussion of the most effective orientations of the PAUT transducer will be presented. Also, the implementation of the inspection on production hardware will be presented. In some cases the weld tool is used as the transducer manipulator and in some cases a portable scanner is used

Russell, Samuel S.↗