Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis

The First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis (aka the STEP 1 Project or the Project) aimed to (1) developed a brand-new web tool that could provide decision support through free, rapid techno-economic analysis of behind-the-meter solar+storage systems for industrial process heat and (2) conduct high-level analyses of the cost-competitiveness of the same systems across the US in key sectors. The STEP 1 web tool collects key location, land availability, thermal load profile, proccess heat temperature and media, and other key parameters through an easy-to-use user interface (UI). The UI was designed to meet the user at their level of understanding by minimizing the number of required inputs as much as possible while including options for more nuanced inputs if the user desires. STEP 1 advises users on which solar thermal tehcnologies that could fit their needs based on the inputs provided (namely process media and temperature). The tool can model a wide range of solar thermal technologies including flat plate collectors, evacuated tubes, parabolic troughs, linear Fresnel, and molten salt towers all with corresponding thermal energy storage (TES) - solar PV with resistive heating and TES is also included. Once the parameters are collected, a nominal thermal energy production profile for the facility's location is generated using NREL's System Advisory Model (SAM) and then passed to a modified version of NREL's REopt platform to optimize the size (capacity) and dispatch of the solar+storage system to minimize lifecycle costs subject to energy balance, fuel and electricity rates, emission reductions goals, and other constraints. This entire process takes less than 20 minutes, is completely free, requires zero coding skills, and provides the user with a high-level assessment on the techno-economic feasability of deploying solar+storage systems for their energy needs. In addition to the development of the STEP 1 web tool, the project completed two complementary analyses focused on leveraging the backend code of STEP 1, public industrial facility locations and fuel consumption data, and key sector information to assess the economic opportunity of reducing fuel costs at various levels of capacity factor around the US. Both analyses found that there are key markets, locations, industrial sectors (namely food and beverage), and degrees of offset where solar thermal technologies could be cost-effectively deployed, highlighting a key market entry point for these technologies, and assessing deployment potential. In summary, the STEP 1 project improved the opportunities for solar+storage systems to expand into the industrial process heat market through breaking down barriers to assessing these technologies.

14 SOLAR ENERGY↗

Enhanced convection for higher module and system efficiency (Final Technical Report)

The goal of this work is to develop new solar photovoltaic (PV) modules and solar system-scale designs that promote an increase of the convective heat transfer coefficient of at least 40%, reducing the operating temperature of the solar PV panels, and leading to a boost on the annual energy yield by at least 5%. By achieving this goal, we further foresee decreasing solar panel degradation by +0.3%/year, reducing the LCOE by 2.9-4.5¢/kWh. Currently, this question and/or approach is not considered though it is a relevant factor in performance/efficiency. The technology proposed will be at a mature stage by the end of the project and could be aligned to be proven on a full-field test. PV users, installers and manufacturers will be interested in the technology due to the aforementioned benefits. The work was conducted through a suite of wind tunnel experiments, numerical simulations and field experiments. These were then evaluated through a correlation encompassing the entire data set and implementing findings into NREL SAM. The work resulted in eight peer reviewed publications with three others in preparation. The key results of the project are 1.) Showing the capability of increasing the solar farm power production by increasing the heat transfer coefficient; 2.) Providing strategies for achieving this through large scale arrangement manipulation (heights, spacings, angles), flow deflectors and vortex generators; 3.) Demonstrating scalability of results by comparing numerical simulations, wind tunnel experiments and field experiments; 4.) Providing a correlation to be able to capture the various arrangements while exploiting the heat transfer coefficient; and 5.) Proving the feasibility of such strategies and their capacity through a comprehensive techno-economic analysis. For the heat transfer coefficients, gains of 40% were attained and increases in power in the excess of 5% were observed. For heat mitigation strategies, consideration at the PV array scale were inter-panel spacing, panel height and panel angles while at the module level, wind breaks such as solid walls and selected gaps were evaluated as well as vortex generators on the panel. All proposed strategies saw an increase in heat transfer coefficient. For scalability, results were compared against field experiments and a correlation for the heat transfer quantity was attained leading to a parametric understanding of the variations and impact in the heat transfer coefficient independent of tools implemented (wind tunnel/numerical simulations). The strategies were also further assessed by a technoeconomic analysis finding improvements based on LCOE with respect to location (several states with varies atmospheric conditions/geographic locations) yielded different results. Improvements on this end were also observed especially towards the colder climates and when considering bi-facial modules. The quantitative demonstrations of such conclusions are provided in the main portion of this document with complementary results and their narration. Milestones and go/no-go points were successfully met in the project.

14 SOLAR ENERGY↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

Off-design performance of molten salt-driven Rankine cycles and its impact on the optimal dispatch of concentrating solar power systems

This paper presents a model for improving off-design performance predictions for molten salt-driven Rankine power cycles, such as in concentrating solar power tower applications. The model predicts cycle off-design performance under various boundary conditions, including molten salt inlet temperature, mass flow rate, and ambient temperature. The model is validated using industry performance data and benchmarked with results from the literature. A complete concentrating solar power plant, inclusive of solar heliostat field and receiver, is then considered, by implementing the Rankine cycle off-design performance results into the National Renewable Energy Laboratory’s System Advisor Model software, which includes a tool that determines optimal power production schedules. The work improves upon the current System Advisor Model by updating off-design performance characteristics. A case study demonstrates the impact of cycle off-design behavior on annual performance for a stand-alone concentrating solar power system and a concentrating solar power-photovoltaic hybrid system. In addition, we demonstrate how cycle off-design performance influences optimal operator dispatch decisions and, thereby, overall system design and economics. We conclude that off-design cycle performance impacts “optimal” sub-system sizing, especially for a concentrating solar power-photovoltaic hybrid configuration in which concentrating solar power must dispatch in conjunction with photovoltaic generation.

14 SOLAR ENERGY↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital twin advanced distribution management systems (ADMS) and methods

Advanced Distribution Management Systems not generally optimize over the entire feeder because there are few high-fidelity distribution circuit models and real-time distribution-connected sensors are rare. The limited observability at the distribution level makes it difficult to globally optimize distribution operations and issue control setpoints to power systems equipment or Distributed Energy Resources (DER) to perform grid-support services. For example, setpoints can be issued to DER based on results from an optimization module that incorporates a static or time-series feeder simulation. Feeder simulation initial conditions are populated with photovoltaic (PV) and load forecasts, state estimation results, and/or digital twin measurements or state output. The real-time (RT) digital twin runs a model of the feeder to generate state estimation pseudo-measurements since there are limited live feeder measurements.

Johnson, Jay Tillay↗

On the Radiation Effects of Strontium Ions on Satellite Solar Cells in Low Earth Orbits

This study focuses on the radiation effects 19 of Sr + ions—generated from high-altitude nuclear explosions (HANE)—on satellite solar cells in low-Earth orbits (LEO). Along four selected satellite orbits, ion fluences are sampled inside the evolving Sr + distributions for days, determined from our newly developed HANE environment model. These fluences, along with the help of radiation transport codes including the MULASSIS and SRIM models, enable us to quantify the radiation damages by determining the values of total ionizing doses and the equivalent 1 MeV electron fluences for displacement damages. Comparing the dose values to existing experimental data, we conclude that HANE-generated Sr + ions have limited darkening effects to quartz solar cell coverglasses in LEO with apogees of 100s to 1000 km. In addition, with the extremely high equivalent fluences, we also conclude that these Sr+ ions may cause severe or even fatal displacement damage to exposed solar photovoltaic (PV) cells on satellites in LEO. The radiation effects of Sr + ions are much less significant for the orbits with high apogees beyond ten thousand km. We also conducted model parameter sensitivity studies on the charge exchange cross-sections, neutral atmosphere density profiles and explosion local time positions, and the above conclusions stay unchanged. The methodology developed in this study can be extended to other HANE-generated heavy ion species in the future.

14 SOLAR ENERGY↗

Diagnosing and overcoming recombination and resistive losses in non-silicon solar cells using a silicon-inspired characterization platform

This project aimed to generate the characterization tools needed for accurate and systematic loss analysis in non-silicon photovoltaic solar cell technologies and, through the use of these tools and analysis techniques, contribute to the development of a novel class of hetero-contacts to II-VI absorbers, with the final goal of demonstrating record-breaking CdSeTe devices. CdSeTe solar cells provide a prime example of the potential impact of the techniques we proposed to develop and implement: record poly-CdSeTe cells have bandgap-voltage deficits (W oc ) of approximately 550 mV, as compared with below 400 mV for all other mature PV technologies. Similarly, these record CdSeTe devices have FFs below 80%, when other mature cells are near or above 85%. Frustratingly, a systematic identification of the origin of these sub-par performances—for example recombination or resistive losses—has been lacking, thus slowing down the development of these technologies. Similarly, it is often asserted that CdSeTe cells need a better back (hole) contact. Although most believe this is true, no one knew—at the start of this project—how high the V oc and FF could be for a given cell if it had a perfect back contact. Such characterization techniques and loss analysis methods exist and are routinely performed on c-Si solar cells (e.g. injection-dependent lifetime, Suns-V oc , transfer length method, etc). Over the years, they have been instrumental in the development of silicon devices that operate at 91% of their theoretical (Auger) limit. Lifetime testing, and the associated reconstruction of the implied-J-V curve, can moreover be performed at every cell-processing step, thus allowing a direct peek into the impact of that step on cell performance. Therefore, adapting these techniques and tools to non-Si devices would greatly improve their learning rate. In this project, we developed a Suns-ERE technique—the equipment, methodology, and know-how—to measure the implied-J-V curve, the pseudo-J-V curve, and the actual J-V curve of a thin-film solar cell, allowing an accurate assessment of the quality of the bulk material and its surface passivation, the selectivity of the contact, and its resistivity. We used this technique to show that the absorber of present CdSeTe solar cells is capable of achieving 1 V Voc,, that passivation layers exist (e.g., Al2O3) that can support such high voltages, and that the barrier is identifying contact layers that are both passivating and carrier-selective. The characterization platform created in this project and the understanding generated using it will accelerate the progress of non-silicon PV technologies. In particular, the project will contribute to CdSeTe solar cells with Voc > 1 V and cell efficiency > 24%. Such cells provide a pathway to module-level efficiencies >23%. As CdSeTe presently competes with silicon on module cost (in $\$ $/W) and yet has significantly more room for efficiency gains, the potential for LCOE reduction is particularly large. For example, CdTe modules with an efficiency of 21% would allow an LCOE below $\$ $0.04kWh -1 in average US climates.

14 SOLAR ENERGY↗

CIGS Technology Advancement via Fundamental Modeling of Defect/Impurity Interactions (Final Technical Report)

The primary goals of the proposed work were to provide modeling tools (and the associated insight which comes along with model development) for design and optimization of CuIn x Ga 1-x Se 2 (CIGS) and CdSeTe (CST) solar cell manufacturing processes and to establish the foundation for comprehensive end-to-end predictive modeling tools to enable optimization of thin film photovoltaic technology for performance, cost, yield, and reliability. The initial focus of efforts within this project was to develop coupled process/optical/device models for CIGS PV technology and to work with Siva Power to apply that TCAD (technology computer-aided design) system to improve the efficiency and reduce manufacturing costs for CIGS solar cells. Our approach to that end was to generate an extensive database of DFT calculations and to use those calculations via statistical thermodynamics methods and Monte Carlo simulation to develop and characterize models for the behavior of native defects as well as intentional and unintentional impurities, including the redistribution of the primary components of CIGS films. Increased effort went toward coupling those models for defect behavior and composition evolution to the performance of multicrystalline CIGS solar cells via prediction of doping level and recombination lifetime as function of manufacturing process. In the second budget period, the project pivoted to developing a similar system for the CdSeTe system, focused especially on understanding the role of Se/Te alloy concentration. Execution of the project resulted in the successful development of TCAD systems for both CIGS and CdSeTe thin film PV within the Synopsys Sentaurus framework by utilizing the Alagator interface. In the first budget period of the project, we developed quantitative models for the major components of CIGS PV and implemented them within a framework that couples process, optical, and device simulation. From the insights we have gained, we identified novel opportunities for enhancing CIGS solar cell performance and have laid the groundwork to further optimize the layer structure, composition profile, and thermal cycles for substantially improved efficiency and lower manufacturing costs. For the CIGS system, process changes to achieve greater than 1% absolute enhancement in efficiency were identified, but testing of those approaches was stymied by lack of a domestic CIGS manufacturing partner after the closure of Siva Power as well as Miasole. For CdSeTe, a fully capable TCAD system only became ready to apply near the end of the project period, so substantial opportunities remain to apply those models to enhance the leading thin film PV technology.

14 SOLAR ENERGY↗

Colloidal Quantum Dot Photovoltaics: Current Progress and Path to Gigawatt Scale Enabled by Smart Manufacturing

Colloidal quantum dots (QDs) have lately been pursued with intense vigor for optoelectronic applications such as photovoltaics (PV), flexible electronics, displays, mid-infrared photodetectors, lasers, and single-photon emitters. These nanometer-sized semiconducting crystals can be suitably mass-produced and size-tuned via cost-effective solution-based synthetic routes to operate in the quantum size confinement regime, endowing them with a wide array of exotic optical and electronic properties. While the first potential market entry could be in displays and in niche applications such as “internet-of-things”, ultimately, the technology has the potential to influence large-scale terrestrial power generation, because it is amenable to high-throughput synthesis from Earth-abundant materials and large-area solution-based coating techniques and can be air-stable. In this Review, we chronicle the recent advances that have propelled QD PV toward commercialization and highlight potential areas for further progress. We present an account of the material compositions being explored as QDs and their various benefits, major chemical passivation and doping strategies that have been developed to allay QD surface traps, and advanced device designs deployed to maximize charge extraction. We also discuss pathways to >20% efficient QD PV and describe recent advances in high-precision and autonomous synthesis of such materials. With recent demonstrations of scalable synthesis of high-quality QDs, smart manufacturing of QDs and QD solids, and fabrication of stable solar cells under ambient conditions, we suggest that the technology is on the road to achieving maturity and technological relevance and that gigawatt per year distributed panel production sites may be within reach.

14 SOLAR ENERGY↗

Probabilistic analysis of masked loads with aggregated photovoltaic production

In this paper we present a probabilistic analysis framework to estimate behind-the-meter photovoltaic generation in real time. We develop a forward model consisting of a spatiotemporal stochastic process that represents the photovoltaic generation and a stochastic differential equation with jumps that represents the demand. Here, we employ this model to disaggregate the behind-the-meter photovoltaic generation using net load and irradiance measurements.

14 SOLAR ENERGY↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

Cost-Effectiveness of Local Distribution Tied Solar within KyMEA

KyMEA is a Kentucky joint action agency which provides electric transmission and energy services to eleven municipal utilities. One of KyMEA's member cities, Frankfort, has set a goal to reach 100% renewable generation for the city load by 2023 and 100% carbon free city operations and 100% renewable generation community-wide by 2030. The aim of this research was to determine if the Frankfort city government could reduce its power costs by implementing distribution tied solar while also avoiding any cross subsidization between other KyMEA member utilities or other Frankfort Plant Board customers. The project simulated the KyMEA generation portfolio and transmission system from KyMEA's cost perspective using the NREL Engage capacity expansion model. Running in operate mode, the authors used Engage to compare KyMEA's costs to operate the baseline system to its costs to operate the system with Frankfort meeting some of its load with distribution-tied PV. The cost perspective of Frankfort Plant Board, meanwhile, was simulated using Python. The simulations indicated that it would be cost-beneficial to KyMEA, i.e., that no additional costs would be borne by other members, and that it would be cost-neutral to Frankfort Plant Board for Frankfort city government to implement distribution tied utility-scale PV. The new load attributes resulting from the distribution-tied PV lowered KyMEA's cost to serve load by improving system load factor, reducing system transmission and energy costs, and increasing revenues from market energy sales.

14 SOLAR ENERGY↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant: Preprint

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗