Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Optical and photophysical properties of platinum benzoporphyrins with C 2v and D 2h symmetry

Platinum(II) mono- and di-benzoporphyrins carrying either ester or imide peripheral groups have been successfully synthesized. These benzoporphyrins possessing C 2v and D 2h symmetry were investigated using a range of techniques including UV-Vis and phosphorescence spectroscopy, differential pulse voltammetry, and transient absorption spectroscopy covering wide spatial and temporal ranges. Up to three oxidation and three reductions within the accessible potential window of dichlorobenzene were observed. Facile reductions for both mono- and dibenzoporphyrin derivatives, more so with imide peripheral substituents were witnessed. Computational studies were supportive of push-pull type interactions within these molecular systems. Here, the formation of triplet excited states within 5 ps after laser excitation was confirmed by femtosecond transient absorption studies. Nanosecond transient absorption studies coupled with phosphorescence lifetime studies revealed relatively rapid relaxation of the triplet excited states as compared to a controlled platinum porphyrin suggesting push-pull type interactions on a slower time scale.

DFT calculations↗

Crossover Flux and Ionic Resistance Metrics in Polysulfide-Permanganate Redox Flow Battery Membranes

A survey of 23 commercially available cation exchange membranes was performed for the downselection of membranes for use in a polysulfide-permanganate redox flow battery (pS-Mn RFB). The survey measured the flux of permanganate ions across a 0.1 mol L −1 concentration gradient as well as the membrane resistance in a 0.5 mol L −1 sodium chloride solution. The membranes exhibited the characteristic flux/resistance trade-off observed in most classes of membranes. To connect the individual membrane testing to how the membranes will perform in a device, cell performance data in a pS-Mn RFB was collected for three membranes from the survey. The coulombic, voltaic, and energy efficiency at low cycle counts aligned with the predictions from the membrane flux and resistance survey results. The study also identified three membranes—Fumapem F-930-RFS, Fumapem FS-715-RFS, and Aquivion E98-09S—that outperformed most other membranes regarding their position on the flux-resistance trade-off curve, indicating them to be good candidates for further testing.

Electrochemistry↗

Mechanism and dynamics of fatty acid photodecarboxylase

The deposition contains diffraction patterns after hit-finding of time-resolved serial femtosecond crystallography measurements on fatty acid photodecarboxylase performed at LCLS XFEL (proposal ID: LT59). Five datasets are available. One dataset without pump laser excitation, labeled as "dark" and four time-resolved datasets with pump laser excitation at four different time-points labeled as "20 ps", "900 ps", "300 ns" and "2 μs". Please check the publication for more information about the datasets.

CXI↗

Machine Learning for Daily Forecasts of Arctic Sea Ice Motion: An Attribution Assessment of Model Predictive Skill

Physics-based simulations of Arctic sea ice are highly complex, involving transport between different phases, length scales, and time scales. Resultantly, numerical simulations of sea ice dynamics have a high computational cost and model uncertainty. We employ data-driven machine learning (ML) to make predictions of sea ice motion. The ML models are built to predict present-day sea ice velocity given present-day wind velocity and previous-day sea ice concentration and velocity. Models are trained using reanalysis winds and satellite-derived sea ice properties. We compare the predictions of three different models: persistence (PS), linear regression (LR), and a convolutional neural network (CNN). We quantify the spatiotemporal variability of the correlation between observations and the statistical model predictions. Additionally, we analyze model performance in comparison to variability in properties related to ice motion (wind velocity, ice velocity, ice concentration, distance from coast, bathymetric depth) to understand the processes related to decreases in model performance. Results indicate that a CNN makes skillful predictions of daily sea ice velocity with a correlation up to 0.81 between predicted and observed sea ice velocity, while the LR and PS implementations exhibit correlations of 0.78 and 0.69, respectively. The correlation varies spatially and seasonally: lower values occur in shallow coastal regions and during times of minimum sea ice extent. LR parameter analysis indicates that wind velocity plays the largest role in predicting sea ice velocity on 1-day time scales, particularly in the central Arctic. Regions where wind velocity has the largest LR parameter are regions where the CNN has higher predictive skill than the LR.

54 ENVIRONMENTAL SCIENCES↗

Gas hydrate petroleum systems: What constitutes the “seal”?

The gas hydrate petroleum system (GHPS) approach, which has been used to characterize gas hydrates in nature, uses three distinct components: a methane source, a methane migration pathway, and a reservoir that not only contains gas hydrate, but also acts as a seal to prevent methane loss. Unlike GHPS, a traditional petroleum system (PS) approach further distinguishes between the reservoir, a unit with generally coarser sediment grains, and a separate overlying seal unit with generally finer sediment grains. Adopting this traditional PS distinction in the GHPS approach facilitates assessments of reservoir growth and production potential. The significance of the seal for the formation of a gas hydrate reservoir as well as for efficiency in methane extraction from the reservoir as an energy resource is evident in findings from recent offshore field expeditions, such as India’s second National Gas Hydrate Program expedition (NGHP-02). In regard to gas hydrate-bearing reservoir formations, the NGHP-02 gas chemistry data indicate a primarily microbial methane source. Fine-grained seal sediment in contact with coarser grained reservoir sediment can facilitate that microbial methane production. Logging-while-drilling and sediment core data also indicate that the overlying fine-grained seal sediment is less permeable than the underlying, highly gas hydrate-saturated reservoir sediment. The overlying seal’s capacity to act as a low-permeability boundary is important not only for preventing methane migration out of the reservoir over time, but also for preventing water invasion into the reservoir during methane extraction from the reservoir. Ultimately, the presence of an overlying, fine-grained, low-permeability “seal” influences how gas hydrate initially forms in a coarse-grained reservoir and dictates how efficiently methane can be extracted as an energy resource from the gas hydrate reservoir via depressurization.

Geochemistry & Geophysics↗

Data for "Plasmon-driven exciton formation in a non-equilibrium Fermi liquid"

This repository contains source data for key plots presented in the manuscript "Plasmon-driven exciton formation in a non-equilibrium Fermi liquid." Experimental data that was analyzed in Igor Pro 8 are presented as the .pxp files used to generate individual sub-plots. Electronic spectral function calculations are provided as .txt files, in which consecutive rows refer to the meshgrid x coordinate, y coordinate, spectral function (and, where relevant, axis-projected local angular momentum). We additionally include the Wannier model and DFT-obtained bulk band structure on which the Wannier model was based. Files are named as the number of the figure in the manuscript to which they correspond, with additional details included where necessary. Details of file names: 2a_DOS_Lxz_Ek_KGM_40layer_xnum_800kpt_tot.txt: Density of states, xz-axis projected local orbital angular momentum, for 800 points along the K-Gamma-M path, for a 40-layer model. 2c_composite_y.pxp: ARPES (angle-resolved photoemission spectroscopy) spectra along the ky axis, including both a scan near the Fermi level and a scan at high kinetic energies. 2d_LCP_RCP_diff_Sect_20K.pxp: difference between ARPES constant energy cuts at T=20 K at E0 + 0.23 eV taken with left- and right-circularly polarized photons. The polarization-integrated intensity at the constant energy cut is also included. 2e_DOS_L45_E11pt79_m0pt25to0pt25_xnum_800kpt_tot.txt: Density of states, xz-projected local orbital angular momentum, and corresponding k-points in two dimensions from ab-initio electronic structure calculations for a constant-energy cut. 3a_[x]_[y]ps: ARPES cut under excitation at a fluence of x uJ/cm2, measured y ps after photoexcitation. Measurements were performed at 9 K. 3b_[x]: Energy distribution curves under excitation at a fluence x uJ/cm2 at selected delay times after photoexcitation. 4a_ImSigma_vs_temperature.pxp: Imaginary self energy (extracted from ARPES linewidths) at different energies above E0 for selected lattice temperatures. 4b_EELS_lowE.pxp: Electron energy loss spectrum over a low energy range 5b_diff_55m15.pxp: Difference between momentum-integrated Tr-ARPES traces at 55 uJ/cm2 and 15 uJ/cm2 photoexcitation. Time-dependent intensity at each energy level has been normalized to a maximum of 1 for each individual fluence prior to subtraction. 5d_invtau_at_EX_vs_fluence.pxp: decay rate at a specified energy EX for different excitation fluences, from single exponential fits. NOTE: Analyses based on the Wannier model presented here should cite both the associated Article and this dataset. For all other files in the repository, citing the dataset alone is sufficient.

Acharya, Rishi [University of Illinois] (ORCID:000↗

Mammalian complex III heme dynamics studied with pump-probe spectroscopy and red light illuminations

The electronic or molecular mechanisms which initiate photobiomodulation (PBM) in cells are not yet fully understood. Porcine complex III (C-III) of the electron transport chain was characterized with transient absorption spectroscopy (TAS). Then we applied our recently developed continuous wave laser coupled TAS procedure (CW-TAS) to investigate the effect of red light irradiances on the heme dynamics of C-III in its c 1 reduced state. The time constants associated with the axial ligand photodissociation were found to be 3.3 ± 0.3 ps for the oxidized state and 4.9 ± 0.4 ps for the c 1 reduced state. The analysis of the CW-TAS procedure yielded no significant changes in the C-III heme dynamics. We rule out the possibility of 635 nm CW light at 4.7 mW/cm 2 inducing a PBM effect on the heme dynamic of C-III, specifically with the photodissociation of its axial ligand.

59 BASIC BIOLOGICAL SCIENCES↗

Single-shot measurement of the nonlinear refractive index of air at 92 µm with a picosecond terawatt CO 2 laser

We developed a simple, accurate single-shot method to determine the nonlinear refractive index of air by measuring the evolution of the spatial shape of a laser beam propagating through the atmosphere. A distinctive feature of this new method, which relies on a modified Fresnel propagation model for data analysis, is the use of a hard aperture for producing a welldefined, high-quality beam from a comparatively nonuniform quasi-flat-top beam which is typical for highpeak-power lasers. The nonlinear refractive index of air for a very short (2 ps) long-wave infrared (LWIR) laser pulse was measured for the first time, yielding n 2 = 3.0 × 10 -23 m 2 /W at 9.2 µm. This result is 40% lower than a corresponding measurement with longer (200 ps) LWIR pulses at a similar wavelength.

43 PARTICLE ACCELERATORS↗

Xenon implantation of nanodiamond films for targeted color center emission at sub-nanosecond time scales

In this work, the lifetime of nitrogen-vacancy color centers within nanodiamonds is reduced from 550±13 ps to 297±10 ps through the implantation of xenon. Coupled-mode analysis is employed to characterize the mechanism responsible for the reduction in emission lifetime. The observed spectral lineshape is found to be consistent with a Voigt profile consisting of two Lorentzian resonant peaks at 637 nm and 811 nm that are inhomogeneously broadened by a Gaussian distribution. A convolution of the frequency-domain Lorentzian output, with linewidths less than 1 nm, from the coupled-mode system of equations with a Gaussian with standard deviation of 85 nm is performed to generate the Voigt profile. The shortened emission lifetime is found to be consistent with a coupled mode theory model incorporating coupling between nitrogen-vacancy and xenon-vacancy color centers.

36 MATERIALS SCIENCE↗

Nonlinear refraction and absorption properties of optical materials for high-peak-power long-wave-infrared lasers

Optical materials transparent in the CO 2 laser wavelength range have been evaluated regarding their suitability for components in ultrashort-pulse (≤ a few ps), high-peak-power (≥ a few TW) long-wave infrared (LWIR) lasers. We provide values for the nonlinear refractive index ( n 2 ) for seventeen materials, and onsets for nonlinear absorption for eleven materials. Characterizations were performed using a 2 ps laser pulse at λ =9.2 μ m. This paper methodically presents the newly acquired data in conjunction with existing literature on linear optical properties, establishing it as a comprehensive reference for designing high-peak-power LWIR laser systems.

43 PARTICLE ACCELERATORS↗

Anomalous dips in reflection spectra of optical polymers deposited on plasmonic metals

Abstract We have studied reflection spectra of dye-doped and undoped polymers deposited onto Ag and Au substrates and found anomalous dips in the UV spectral range. On top of Ag substrates, the λ ∼ 375 nm dips were observed in undoped PMMA, PVP, and PS polymers as well as PMMA doped with Rh590 and HITC laser dyes. In silver-based samples, the spectral positions of the observed reflection dips were close to singularities in the refractive indexes of surface plasmon polaritons (SPPs) propagating at the interface between Ag and polymer. The latter singularities can tentatively explain the λ ∼ 375 nm reflection dips, if the scattering of Ag and polymeric films is large enough to launch SPP without any prism or grating. The dips observed in reflection of Rh590:PMMA and HITC:PMMA on top of Au, were more pronounced than those on Ag, broader, shifted to shorter wavelengths, and their spectral positions had large standard deviations. Furthermore, no anomalous dips in gold-based samples were observed in the reflection spectra of undoped PMMA, PVP, and PS polymers, and a modest singularity in the SPP refractive index, predicted theoretically at λ ∼ 500 nm, cannot explain the dips in the UV reflection spectra observed experimentally. It appears likely that the origin of the reflection dips on top of Au substrates is different from that on top of Ag substrates.

36 MATERIALS SCIENCE↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

Electron bunch position determination using a high frequency button beam position monitor in the AWAKE facility

The AWAKE facility uses novel proton beam-driven plasma wakefields to accelerate electron bunches over 10m of Rubidium plasma. Precise monitoring of 2 diverse beam types necessitates an electron beam position monitor (BPM) working in a frequency regime of tens of GHz. A high frequency conical button-style BPM with a working regime of up to 40 GHz has been investigated as a way to discriminate the electromagnetic fields of 19 MeV, 4 ps electron bunches propagating spatially and temporally together with a 400 GeV, 170 ps proton bunch in the AWAKE common beamline. The sensitivity of the HF BPM to the electron beam position is determined under various beam conditions, with both electrons and protons, and integration with a TRIUMF front-end is discussed.

43 PARTICLE ACCELERATORS↗

Analysis of DWPF Sludge Batch 6 (Macrobatch 7): Pour Stream Glass Samples

The Defense Waste Processing Facility (DWPF) began processing Sludge Batch 6 (SB6), also referred to as Macrobatch 7 (MB7), in June 2010. SB6 is a blend of the heel of Tank 40 from Sludge Batch 5 (SB5), H-Canyon Np transfers and SB6 that was transferred to Tank 40 from Tank 51.1 SB6 was processed using Frit 418. Sludge is received into the DWPF Chemical Processing Cell (CPC) and is processed through the Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator Tank (SME). The treated sludge slurry is then transferred to the Melter Feed Tank (MFT) and fed to the melter. During processing of each sludge batch, the DWPF is required to take at least one glass sample to meet the objectives of the Glass Product Control Program (GPCP) and to complete the necessary Production Records so that the final glass product may be disposed of at a Federal Repository. The DWPF requested various analyses of radioactive glass samples obtained from the melter pour stream during processing of SB6 as well as reduction/oxidation (REDOX) analysis of MFT samples to determine the impact of Argon bubbling. Sample analysis followed the Task Technical and Quality Assurance Plan (TTQAP) and an Analytical Study Plan (ASP). Four Pour Stream (PS) glass samples and two MFT slurry samples were delivered to the Savannah River National Laboratory (SRNL) from the DWPF. Table 1-1 lists the sample information for each pour stream glass sample. SB6 PS3 (S03472) was selected as the official pour stream sample for SB6 and full analysis was requested. This report details the visual observations of the as-received SB6 PS No.3 glass sample as well as results for the chemical composition, Product Consistency Test (PCT), radionuclide content, noble metals, and glass density. REDOX results will be provided for all four pour stream samples and vitrified samples of MFT-558 and MFT-568A. Where appropriate, data from other pour stream samples will be provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of Scintillation Detectors Based on Quantum Dots in a Semiconductor Matrix (Final Technical Report)

InAs Quantum Dots (QDs) embedded into GaAs semiconductor waveguide have unique scintillation properties, valuable for nuclear security, medical imaging, and high energy physics. In this work, we developed thick (~25um) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. In this type of detector, the GaAs matrix acts as a stopping material for charged particles or photons generating electrons captured by the QDs acting as luminescence centers. The QD medium is designed to provide fast capture of electrons into QDs (few ps), high QD luminescence efficiency at room temperature (>50%), and strong red-shift of photoluminescence (PL) from the GaAs absorption edge (>250nm). Typical devices consist of a 10-25um thick GaAs layer with embedded sheets of modulation p-type doped InAs QDs and an InGaAs photodetector tuned to the QD emission wavelength. The thick GaAs layer acts also as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (~1cm -1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with both an external photodiode (PD) and an integrated PD which provided an improved optical coupling. In the former case, the external InGaAs PD was air-coupled to the scintillator and had the light collection efficiency of about 1% corresponding to limited light extraction through a planar interface with air due to total internal reflection. The mean charge collected by the integrated PD was in the range of (3÷5)×10 4 photoelectrons per 1 MeV of deposited energy, or ~13-20% of the theoretically achievable light yield. Timing of the integrated device was measured by wire-bonding it to the input of an 8 GHz IC. The scintillation response shows an extremely fast 0.3-0.6 ns decay constant and about 40-70 ps time resolution, limited by the system noise. The combined light yield and decay time makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported making it valuable for high energy physics and medical imaging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Plasma Photonics: Manipulating Light Using Plasmas (Full Technical Final Report)

In this LDRD, we made significant advances on multiple fronts on the investigation and design of plasma-based optical structures to manipulate light at extreme intensities. We have unveiled new fundamental properties of laser-plasma interaction that were leveraged to introduce transformative applications. We first investigated new ways to generate high-amplitude plasma-based optical structures, based on the auto-resonance mechanism in order to produce refractive structures in plasmas. New insights into the interaction of such plasma structures with light waves allowed us to propose new methods for polarization manipulation and control for high-intensity lasers in the nonlinear regime, i.e. allowing the manipulation of an intense laser via its interaction with a less intense “control” laser beam in plasmas. Another application that we demonstrated experimentally is the capability to manipulate the velocity of light waves in plasmas by tailoring its refractive index; we reported the first demonstration of “slow light” and supra-luminal light propagation in plasmas. We also developed a new technological concept that would allow the probing of the type of plasma structures investigated in such applications, using high-bandwidth laser probing [Ludwig Phys. Plasmas 2019]. Finally, first steps were taken towards the demonstration of a plasma-based amplifier and compressor for the National Ignition Facility, in order to achieve powers equal of greater than those delivered by the Advanced Radiographic Capability (ARC). This technique uses a plasma-based grating acting like a compressor and amplifier, which could potentially compress and amplify an 88 ps, 56 J beam from the National Ignition Facility to <10 ps and hundreds of J.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Lapse Vertical Seismic Profiling (VSP) for CO 2 Storage in a Depleted Oil Field in Northern Michigan

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. This report describes the Dover 33 VSP study to test the effectiveness of time-lapse Vertical Seismic Profile (VSP) for detecting and delineating a plume of more than 271,000 tonnes of CO2 injected into the Brown Niagaran and A-1 Carbonate formations within the Dover 33 reef between March 2013 and September 2016. Five 2D walkaway VSP (WVSP) source lines were acquired by SIGMA3 in September 2016 to investigate the possible time-lapse response in both P-wave and PS-wave seismic data. The data was compared to the same survey geometry acquired in March 2013 by SR2020. The seismic energy was recorded into an 80-level, three-component geophone array deployed into the Dover 1-33 well and placed just above the reef. P-wave and PS-wave reflection images were produced for each of the three source lines from both the 2013 baseline and 2016 monitor surveys. The images were then compared to look for changes in the reflectivity at and around the injection location that might indicate how the CO 2 has moved over this time period. This technique revealed several localized areas with sizable impedance differences inside the reef where CO 2 would be expected; however, a large number of similar impedance “hotspots” were also detected outside the reef in areas where injected CO 2 would not be expected. Therefore, a second analysis that involved calculating P-wave and S-wave travel time differences between the 2013 and 2016 VSPs was conducted to look for a change that could be caused by the CO 2 plume.

01 COAL, LIGNITE, AND PEAT↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗