Accessing crystal–crystal interaction forces with oriented nanocrystal atomic force microscopy probes

Biominerals serve as crucial structures of living systems and play an important role for biochemical processes. Understanding their crystallization mechanisms is therefore central to many areas of biology, biogeoscience and biochemistry. Some biominerals, such as bone and dentin, are hierarchical nanocomposite structures constructed by sequentially added individual oriented nanocrystals. The driving forces that enable this oriented assembly are still poorly understood, with advances in understanding limited in part by the availability of techniques that can precisely measure the delicate interactions between nanocrystals, as a function of their separation distance and mutual orientation. Here we provide a novel and comprehensive protocol for i.) fabricating oriented single nanocrystal atomic force microscopy (AFM) probes using focus ion beam (FIB) milling - probes that are capable of accessing the nanoscale forces between oriented single-crystal faces, and ii.) performing oriented nanocrystal interaction force measurements using dynamic force spectroscopy (DFS) and environmental transmission electron microscopy (ETEM)-AFM techniquqes. These methods have recently led to seminal breakthroughs in force quantification for understanding oriented aggregation at the nanoscale. First, we detail two FIB milling based methods to fabricate AFM nanocrystal probes. One method requires careful pre-coating with a protective layer to avoid FIB damage to the face of interest, which is later chemically removed, and the other entails removal of the FIB damage layer with in situ polishing. We illustrate how to fabricate oriented nanocrystal force probes using commercial bulk crystals or nano/micro-crystals of calcite, zinc oxide, and rutile; the methods are fully transferrable to the apatites comprising bone minerals. The typical protocol for fabricating one AFM crystal probe takes 2-3 h. Finally, we describe how to measure interaction forces between nanocrystals in solution conditions of interest by performing AFM based DFS, or in the controlled environment of ETEM, using the resulting oriented nanocrystal probes. In addition, we illustrate how to quantify the direction-specific interaction forces for a given pair of interacting oriented nanocrystal faces, and how to relate this information generally to understanding crystallization by particle attachment.

Zhang, Xin (ORCID:000000032000858X)↗

The detonation cylinder test: Determination of full wall velocity and shape from a single velocimetry probe with an arbitrary angle

Laser velocimetry probes are used for measuring wall velocity in cylinder test expansion experiments. Previously, a method was developed to determine the full wall velocity, angle and case shape from a single probe aligned with the initial cylinder wall normal (S.I. Jackson, Proc. Combust. Inst., Vol. 35, 2015, pg.1997-2004). However, probes are often positioned at arbitrary (non-normal) angles to optimize light return from the cylinder surface. This work extends the prior method to accommodate arbitrary probe angles and allows solution of the full cylinder wall motion and shape from a single probe, using only the assumption of steady flow in the shock frame. When used in conjunction with the prior method, it can also be used to approximate the detonation product isentrope analytically from a single velocimetry probe at any angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The flush-mounted rail Langmuir probe array designed for the Alcator C-Mod vertical target plate divertor

An array of flush-mounted and toroidally elongated Langmuir probes (henceforth called rail probes) have been specifically designed for the Alcator C-Mod’s vertical target plate divertor and operated over multiple campaigns. The “flush” geometry enables the tungsten electrodes to survive high heat flux conditions in which traditional “proud” tungsten electrodes suffer damage from melting. The toroidally elongated rail-like geometry reduces the influence of sheath expansion, which is an important effect to consider in the design and interpretation of flush-mounted Langmuir probes. The new rail probes successfully operated during C-Mod’s FY2015 and FY2016 experimental campaigns with no evidence of damage, despite being regularly subjected to heat flux densities parallel to the magnetic field exceeding ~1 GW m -2 for short periods of time. A comparison between rail and proud probe data indicates that sheath expansion effects were successfully mitigated by the rail design, extending the use of these Langmuir probes to incident magnetic field line angles as low as 0.5°.

47 OTHER INSTRUMENTATION↗

Probe measurements of electric field and electron density fluctuations at megahertz frequencies using in-shaft miniature circuits

In this work, a four-tip electrostatic probe is constructed to measure high-frequency (0.1–10 MHz) fluctuations in both the electric field (one component) and electron density in a laboratory plasma. This probe also provides data for the local electron temperature and density. Circuits for high-frequency measurements are fabricated on two miniature boards, which are embedded in the probe shaft, near the tips to minimize the pickup of common-mode signals. The amplitude and phase response of two circuits to sinusoidal test signals are measured and compared with results from modeling. For both circuits, the phase shift between input and output signals is relatively small (<30°). The performance of the probe is verified in a high-density (~10 13 cm –3 ) and low-temperature (≲10 eV) plasma. The probe successfully measures high-frequency (~2 MHz) fluctuations in the electric field and density, which are associated with lower hybrid drift waves. This probe can provide information on the wave-associated anomalous drag, which can be compared with the classical resistivity.

47 OTHER INSTRUMENTATION↗

Ion-temperature determination with a baffled Langmuir probe

An electrostatic Langmuir probe for real-time measurements of parameters in magnetized plasma is tested in fully ionized, barium, Q-machine plasma. The small-diameter, long-length, tungsten wire sensor, i.e., the probe tip, oriented with its cylindrical axis perpendicular to the magnetic field (B), is partially shielded by ceramic baffles, or masks, that form sensor-access slots between the baffles. Adjusting the azimuthal orientation of the slots, by rotating the probe about its cylindrical axis, changes the fraction of proximity gyro-orbiting electrons, relative to the fraction of proximity gyro-orbiting ions, that can access the recessed sensor along the magnetic field. Thus, the ratio between the electron and ion saturation currents, $I^{sat}_e$ and $I^{sat}_i$, can be adjusted without having affected the probe bias voltage V b . When optimally shielded ($I^{sat}_e/I^{sat}_i$=1), accurate, real-time measurements of space potential Vs can be acquired. When maximally shielded ($I^{sat}_e/I^{sat}_i$ << 1), accurate, real-time measurements of ion temperature T i can be acquired. Subtracting the floating potential V f of an optimally shielded baffled probe from V f of a maximally shielded baffled probe yields T i (and its fluctuation phase) in real time.

47 OTHER INSTRUMENTATION↗

All-in-one probe for exploring self-organized two-fluid equilibria in toroidal plasmas

This paper presents the development of an all-in-one probe to simultaneously measure all components of the generalized Ohm’s law in reversed-field pinch plasmas and tokamaks. The polyhedral configuration of the Mach probe is achieved through the specific arrangement, angle, and depth of the collimator channel apertures drilled into the surface of a hollow boron nitride cylinder encasing it. This probe includes a central Mach probe to assess the ion velocity field in three dimensions. Initial tests at the RELAX and Madison Symmetric Torus machines have confirmed the probe’s effectiveness, revealing an octahedron form similar to a tetrahedron. The probe seems to function correctly and is expected to facilitate the empirical validation of two-fluid equilibria at the periphery of toroidal plasmas.

Instruments & Instrumentation↗

Quantification of in-contact probe-sample electrostatic forces with dynamic atomic force microscopy

Here, atomic force microscopy (AFM) methods utilizing resonant mechanical vibrations of cantilevers in contact with a sample surface have shown sensitivities as high as few picometers for detecting surface displacements. Such a high sensitivity is harnessed in several AFM imaging modes. Here, we demonstrate a cantilever-resonance-based method to quantify electrostatic forces on a probe in the probe-sample junction in the presence of a surface potential or when a bias voltage is applied to the AFM probe. We find that the electrostatic forces acting on the probe tip apex can produce signals equivalent to a few pm of surface displacement. In combination with modeling, the measurements of the force were used to access the strength of the electrical field at the probe tip apex in contact with a sample. We find an evidence that the electric field strength in the junction can reach ca. 1 V nm –1 at a bias voltage of a few volts and is limited by non-ideality of the tip-sample contact. This field is sufficiently strong to significantly influence material states and kinetic processes through charge injection, Maxwell stress, shifts of phase equilibria, and reduction of energy barriers for activated processes. Besides, the results provide a baseline for accounting for the effects of local electrostatic forces in electromechanical AFM measurements as well as offer additional means to probe ionic mobility and field-induced phenomena in solids.

36 MATERIALS SCIENCE↗

Probing the progenitors of Type Ia supernovae using circumstellar material interaction signatures

This work aims to study different probes of Type Ia supernova (SN Ia) progenitors that have been suggested to be linked to the presence of circumstellar material (CSM). In particular, we have investigated, for the first time, the link between narrow blueshifted Nai D absorption profiles and the presence and strength of the broad high-velocity Caii near-infrared triplet absorption features seen in SNe Ia around maximum light. With the probes exploring different distances from the SN; Nai D > 10 17 cm, high-velocity Caii features < 10 15 cm. For this, we have used a new intermediate-resolution X-shooter spectral sample of 15 SNe Ia. We do not identify a link between these two probes, implying either that, one (or both) is not physically related to the presence of CSM or that the occurrence of CSM at the distance explored by one probe is not linked to its presence at the distance probed by the other. However, the previously identified statistical excess in the presence of blueshifted (over redshifted) Nai D absorption is confirmed in this sample at high significance and is found to be stronger in SNe Ia hosted by late-type galaxies. This excess is difficult to explain as being from an interstellar-medium origin as has been suggested by some recent modelling, as such an origin is not expected to show a bias for blueshifted absorption. However, a circumstellar origin for these features also appears unsatisfactory based on our new results, given the lack of link between the two probes of CSM investigated.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster — Thur Eve — 77: Implanted Brachythearpy Seed Movement due to Transrectal Ultrasound Probe-Induced Prostate Deformation

The study investigated the movement of implanted brachytherapy seeds upon transrectal US probe removal, providing insight into the underlying prostate deformation and an estimate of the impact on prostate dosimetry. Implanted seed distributions, one obtained with the prostate under probe compression and another with the probe removed, were reconstructed using C-arm fluoroscopy imaging. The prostate, delineated on ultrasound images, was registered to the fluoroscopy images using seeds and needle tracks identified on ultrasound. A deformation tensor and shearing model was developed to correlate probe-induced seed movement with position. Changes in prostate TG-43 dosimetry were calculated. The model was used to infer the underlying prostate deformation and to estimate the location of the prostate surface in the absence of probe compression. Seed movement patterns upon probe removal reflected elastic decompression, lateral shearing, and rectal bending. Elastic decompression was characterized by expansion in the anterior-posterior direction and contraction in the superior-inferior and lateral directions. Lateral shearing resulted in large anterior movement for extra-prostatic seeds in the lateral peripheral region. Whole prostate D90 increased up to 8 Gy, mainly due to the small but systematic seed movement associated with elastic decompression. For selected patients, lateral shearing movement increased prostate D90 by 4 Gy, due to increased dose coverage in the anterior-lateral region at the expense of the posterior-lateral region. The effect of shearing movement on whole prostate D90 was small compared to elastic decompression due to the subset of peripheral seeds involved, but is expected to have greater consequences for local dose coverage.

60 APPLIED LIFE SCIENCES↗

Specificity of probe measurements in diffuse plasmas of dense gases in strong electric fields

The article is devoted to extending the applicability of the probe diagnostics to the range of higher pressures of the plasma-forming gas by taking into account the effect of the probe shadow on the anode. The probe current–voltage characteristic in the diffuse plasma of a dense gas in a strong electric field was measured, and the influence of the probe potential and probe current on the dimensions of the probe shadow on the anode was studied experimentally. The experiments were carried at different currents of a steady-state glow discharge and different velocities of the gas flow through the discharge. The plasma-forming gas was nitrogen at a pressure of P = 100 Torr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating collapsible plasmonic gaps on near-field probes for polarization-resolved mapping of plasmon-enhanced emission in 2D material

Scanning near-field optical microscopy (SNOM) is an important technique used to study the optical properties of material systems at the nanoscale. In previous work, we reported on the use of nanoimprinting to improve the reproducibility and throughput of near-field probes including complicated optical antenna structures such as the ‘campanile’ probe. However, precise control over the plasmonic gap size, which determines the near-field enhancement and spatial resolution, remains a challenge. Here, we present a novel approach to fabricating a sub-20 nm plasmonic gap in a near-field plasmonic probe through the controlled collapse of imprinted nanostructures using atomic layer deposition (ALD) coatings to define the gap width. The resulting ultranarrow gap at the apex of the probe provides a strong polarization-sensitive near-field optical response, which results in an enhancement of the optical transmission in a broad wavelength range from 620 to 820 nm, enabling tip-enhanced photoluminescence (TEPL) mapping of 2-dimensional (2D) materials. We demonstrate the potential of this near-field probe by mapping a 2D exciton coupled to a linearly polarized plasmonic resonance with below 30 nm spatial resolution. This work proposes a novel approach for integrating a plasmonic antenna at the apex of the near-field probe, paving the way for the fundamental study of light-matter interactions at the nanoscale.

Zhou, Junze (ORCID:000000020682767X)↗

Design and testing of microfabricated surgical tools for large animal probe insertion

Neural probes provide therapeutic stimulation for neuropsychiatric disorders or record neural activity to investigate the workings of the brain. Researchers utilize 6 mm long temporary silicon stiffeners attached with biodissolvable adhesive to insert flexible neural probes into rat brains, but increasing the probe length fivefold makes inserting large animal probes a significant challenge because of an increased potential for buckling. This study compared the insertion success rates of 6 mm and 30 mm long silicon stiffeners that were 80 μm wide and 30 μm thick, and ascertained the material thickness and modulus of elasticity that would provide successful insertion for a 30 mm probe. Using a microdrive, stiffeners were inserted into an agarose brain phantom at controlled insertion speeds while being video-recorded. Twenty-five percent of the 30 mm silicon stiffeners fully inserted at speeds approximately four times higher than the target rate of 0.13 mm/s, while 100 percent of the 6 mm silicon stiffeners inserted successfully at target speed. Critical buckling loads (P cr ) were calculated for the 6 mm and 30 mm silicon stiffeners, and for 30 mm diamond and tungsten stiffeners, with thicknesses varying from 30-80 μm. Increasing the thickness of the material by 10 μm, 20 μm and 30 μm improved the P cr by 2.4, 4.7 and 8.2 times, respectively, independent of the material, and substituting diamond for silicon multiplied the buckling capacity by 5.0 times. Stiffeners made of silicon for large animal probe insertion are not strong enough to withstand buckling upon insertion without a significant increase in thickness. Replacing silicon with diamond and increasing the thickness of the stiffener to 50 μm would afford a stiffener with the same P cr capacity as the 6 mm silicon stiffener that had a 100 percent insertion success rate. Experiments should continue with diamond to determine a minimum thickness that will ensure successful insertions and provide an adequate margin of safety.

42 ENGINEERING↗

Shielded and Low-Damping SPM Probes for Quantitative Electrical and Electrochemical Characterization (Phase IIA)

The purpose of this DOE SBIR award was to develop new scanning probe microscopy tools for the elucidation of electrical and electrochemical properties at the nanoscale. High performance probes are important for energy materials research. In both solar cells and batteries, the essential physics and chemistry occur at the nanoscale and nanoscale characterization tools are required for their elucidation. Two products were developed: an electrically shielded probe and an electrically conductive probe with low leakage currents. Our processes were based on post processing of existing probes and fabrication methods were tested, leading to a laser micromachining based approach that led to the first minimal viable product. We invented a method to make a reliable electrical contact that attaches a flexible printed circuit board to the chip. enable leak-free operation crucial when used in conductive liquids and electrolytes. This proprietary solution improves chip handling, reduces contamination, and maintains effective electrical contact. The probes fabricated in this Phase IIa are a minimal viable product which attracted attention from various tip manufacturers and instrument manufacturers alike.

36 MATERIALS SCIENCE↗

Shielded and Low-Damping SPM Probes For Quantitative Electrical and Electrochemical Characterization (Phase IIB)

The purpose of this DOE SBIR award was to develop new scanning probe microscopy tools for the elucidation of electrical and electrochemical properties at the nanoscale. High performance probes are important for energy materials research. In both solar cells and batteries, the essential physics and chemistry occur at the nanoscale and nanoscale characterization tools are required for their elucidation. The introduced new models are a shielded probe and an electrically insulated probe where only less than one micron of a conductive tip is exposed. In Phases I and IIa, we explored the development of cost-effective methods to insulate cantilevers from aqueous solutions and patented a technology that provides an insulated electrical contact to the tip. Also, our technology was adapted to be compatible with all popular commercial AFM systems. In Phase IIb, we improved reproducibility and batch size to drive down costs while maintaining quality control with testing. We transformed our product into a convenient turnkey solution to make electrochemical characterization approachable to a wide range of researchers. In January 2021, the technology was well received by the AFM community and Nanosurf Inc. (Woburn, MA) acquired Scuba Probe Technologies. The technology and expertise of Scuba Probe Technologies complements Nanosurf’s development of the full range of nano-electrical characterization tools.

36 MATERIALS SCIENCE↗

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗

The flush-mounted rail Langmuir probe array designed for the Alcator C-Mod vertical target plate divertor

An array of flush-mounted and toroidally elongated Langmuir probes (henceforth called rail probes) have been specifically designed for the Alcator C-Mod’s vertical target plate divertor and operated over multiple campaigns. The “flush” geometry enables the tungsten electrodes to survive high heat flux conditions in which traditional “proud” tungsten electrodes suffer damage from melting. The toroidally elongated rail-like geometry reduces the influence of sheath expansion, which is an important effect to consider in the design and interpretation of flush-mounted Langmuir probes. The new rail probes successfully operated during C-Mod’s FY2015 and FY2016 experimental campaigns with no evidence of damage, despite being regularly subjected to heat flux densities parallel to the magnetic field exceeding ∼1 GW per square meter for short periods of time. A comparison between rail and proud probe data indicates that sheath expansion effects were successfully mitigated by the rail design, extending the use of these Langmuir probes to incident magnetic field line angles as low as 0.5 degree.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrostatic-probe measurements of plasma parameters for two reentry flight experiments at 25000 feet per second

Unique plasma diagnostic measurements at high altitudes from two geometrically similar blunt body reentry spacecraft using electrostatic probe rakes are presented. The probes measured the positive ion density profiles (shape and magnitude) during the two flights. The probe measurements were made at eight discrete points (1 cm to 7 cm) from the vehicle surface in the aft flow field of the spacecraft over the altitude range of 85.3 to 53.3 km (280,000 to 175,000 ft) with measured densities of 10 to the 8th power to 10 to the 12th power electrons/cu cm, respectively. Maximum reentry velocity for each spacecraft was approximately 7620 meters/second (25,000 ft/sec). In the first flight experiment, water was periodically injected into a flow field which was contaminated by ablation products from the spacecraft nose region. The nonablative nose of the second spacecraft thereby minimized flow field contamination. Comparisons of the probe measured density profiles with theoretical calculations are presented with discussion as to the probable cause of significant disagreement. Also discussed are the correlation of probe measurements with vehicle angle of attack motions and the good high altitude agreement between electron densities inferred from the probe measurements, VHF antenna measurements, and microwave reflectometer diagnostic measurements.

Jones, W. L., Jr.↗

Flight-test results from two total temperature probes for air-data measurements up to 2014 K (3625 R)

An experimental temperature probe package containing a fluidic oscillator temperature probe and a shielded thermocouple temperature probe was tested during several X-15 flights. The X-15 flights provided greatly varying test conditions, including a wide range of rapidly changing total temperatures and Mach numbers which extended from subsonic to hypersonic speeds. Within restricted ranges of free-stream Mach number, free-stream unit weight flow, and local stagnation pressure, both probes yielded ramp outputs of temperature parallel to ramp inputs of free-stream total temperature. Within these ranges both probes were used to determine total temperature in the Mach 6 temperature environment. Because ambient temperature was known, both probes were used to estimate velocity and Mach number.