Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Fundamental study of transpiration cooling

Isothermal and non-isothermal pressure drop data and heat transfer data generated on porous 304L stainless steel wire forms, sintered spherical stainless steel powder, and sintered spherical OFHC copper powder are reported and correlated. Pressure drop data was collected over a temperature range from 500 R to 2000 R and heat transfer data collected over a heat flux range from 5 to 15 BTU/in2/sec. It was found that flow data could be correlated independently of transpirant temperature and type (i.e., H2, N2). It was also found that no simple relation between heat transfer coefficient and specimen porosity was obtainable.

Koh, J. C. Y.↗

Heat-transfer and pressure distributions for laminar separated flows downstream of rearward-facing steps with and without mass suction

Heat-transfer and pressure distributions were measured for laminar separated flows downstream of rearward-facing steps with and without mass suction. The flow conditions were such that the boundary-layer thickness was comparable to or larger than the step height. For both suction and no-suction cases, an increase in the step height resulted in a sharp decrease in the initial heat-transfer rates behind the step. Downstream, however, the heat transfer gradually recovered back to less than or near attached-flow values. Mass suction from the step base area increased the local heat-transfer rates; however, this effect was relatively weak for the laminar flows considered. Even removal of the entire approaching boundary layer raised the post-step heat-transfer rates only about 10 percent above the flatplate values. Post-step pressure distributions were found to depend on the entrainment conditions at separation. In the case of the solid-faced step, a sharp pressure drop behind the step was followed by a very short plateau and relatively fast recompression. For the slotted-step connected to a large plenum but without suction, the pressure drop at the base was much smaller and the downstream recompression more gradual than that for solid-faced step.

Brown, R. D.↗

Experimental and Computational Characterization of a Modified Sioutas Cascade Impactor for Respirable Radioactive Aerosols

Oak Ridge National Laboratory is collecting and characterizing aerosols released when spent nuclear fuel (SNF) rods are fractured in bending. An aerosol collection system was designed and tested to collect respirable sized (<10 μm aerodynamic diameter [AED]) particulates inside a hot cell facility. The setup is a modified version of the commercially available Sioutas cascade impactor, to which additional stages were added to expand the aerosol collection range from 2.5 to ~15 μm AED. To accommodate the additional stages and specific test conditions, the operating flow rate for aerosol collection was reduced, and testing was conducted by using pressure drop measurements, surrogate dust collection, and particle size characterization. The fluid flow distribution within the cascade and its stages was simulated in STAR-CCM+, and the stage-wise pressure drops obtained using the computational fluid dynamics model were then compared to experimental data. Lagrangian particle simulations were also performed, and stage-wise collection statistics were obtained from the simulation for comparison with the experimental data obtained using SNF-surrogate dust particles. The results provide valuable insights into the stage-wise particle collection characteristics of the modified cascade impactor and can also be used to improve the prediction accuracy of the manufacturer-determined analytical correlations.

aerosol modeling↗

Numerical study to predict the effect of surface roughness on the thermal and hydraulic performance of additively manufactured heat exchangers

Heat exchangers are used in many industries to transfer thermal energy between two or more objects with an associated thermal and hydraulic performance indicated by thermal effectiveness and pressure drop respectively. Many investigations have aimed to enhance the thermal effectiveness of heat exchangers by introducing turbulent flow inducers that increase the heat transfer rate at the expense of increasing pressure drop. Flow inducers like surface roughness can be controlled with advanced manufacturing methods like additive manufacturing for heat exchanger production. Selecting and manufacturing an optimal surface roughness for heat exchangers requires a more comprehensive approach that accounts for the surface roughness effect on the thermal and hydraulic performance of a sample. Since fabricating samples with additive manufacturing to a desired surface roughness can be an extensive experimental process, this study will fundamentally investigate the effect of surface roughness on the thermal and velocity boundary layers for various surface roughness profiles with physics-based computational modeling. To accurately model the surface roughness effect on thermohydraulic performance, correlations like roughness ratio, friction factor, and Nusselt number are investigated. This study expects to indicate correlations for different flow regimes which can successfully predict the effect of surface roughness on thermohydraulic performance. Results generated from modeling surface roughness effect with unique correlations are then compared to experimental data obtained from literature for validation. The results of this study will provide insight to understand the thermal fluid physics associated with surface roughness and design guidelines for heat exchangers produced with additive manufacturing.

36 MATERIALS SCIENCE↗

I 2 S-LWR microchannel heat exchanger design and experimental validation

The Integral Inherently Safe Light Water Reactor (I 2 S-LWR) includes primary-to-secondary coolant heat exchangers located in the downcomer of the reactor pressure vessel. A microchannel heat exchanger (MCHX) configuration is selected to meet the limited available volume and high heat duty requirements. The design, modeling, and optimization of the liquid-liquid MCHX is outlined. In addition, the performance of a MCHX test section representative of the I 2 S-LWR MCHX design is validated experimentally. Experimental results show that heat transfer and pressure drop correlations developed for larger, macroscale channels lead to accurate predictions of performance. Additionally, this study shows that an MCHX can deliver the required heat duties within the available space and pressure drop constraints of the overall I2 S-LWR design.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of a multiple venturi fuel-air preparation system

Spatial fuel-air distributions, degree of vaporization, and pressure drop were measured 16.5 cm downstream of the fuel injection plane of a multiple Venturi tube fuel injector. Tests were performed in a 12 cm tubular duct. Test conditions were: a pressure of 0.3 MPa, inlet air temperature from 400 to 800K, air velocities of 10 and 20 m/s, and fuel-air ratios of 0.010 and 0.020. The fuel was Diesel #2. Spatial fuel-air distributions were within + or - 20 percent of the mean at inlet air temperatures above 450K. At an inlet air temperature of 400K, the fuel-air distribution was measured when a 50 percent blockage plate was placed 9.2 cm upstream of the fuel injection plane to distort the inlet air velocity fuel injection plane to distort the inlet air velocity profile. Vaporization of the fuel was 50 percent complete at an inlet air temperature of 400K and the percentage increased linearly with temperature to complete vaporization at 600K. The pressure drop was 3 percent at the design point which was three times greater than the designed value and the single tube experiment value. No autoignition or flashback was observed at the conditions tested.

Tacina, R. R.↗

Gas-Liquid Packed Bed Reactors in Microgravity

Flow regime and pressure drop data was obtained and analyzed. Pulse flow exists at lower liquid flow rates in 0-g compared to 1-g. 1-g flow regime maps do not apply in microgravity. Pressure drop is higher in microgravity (enhanced interfacial effects).

Balakotaiah, Vemuri↗

Image Characterization of Reactions Generated by an Aeroengine Micromixing Injector for Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blend

An aeroengine micromixing injector, originally designed for lean direct injection of jet fuel, was adapted to work with hydrogen, natural gas, and any blend in between. The ultimate goal of the design was to achieve low NOx emissions when operated on pure hydrogen; to better characterize its performance, flame imaging diagnostics was implemented. Three types of cameras mounted parallel to the injector base and pointing towards the quartz combustor cylinder with the same angle were operated simultaneously: Nikon D90, Dynacolor FB-N9-U, and Phantom v7.1, to capture the visible spectrum, OH* chemiluminescence, and dynamic behavior of the flames, respectively. The current work also includes the overlapping of visible spectrum and OH* chemiluminescence, as an effort to qualitatively define the heat release over the flame area, i.e., UV over visible domain. Additionally, a z-type schlieren configuration was employed to reinforce the presence of some small-scale details occurring near the injector outlet ports. Using the airbox pressure drop, preheat temperature, fuel composition and flame temperature as the factors of study, a Box Behnken model was designed yielding into a 16-points matrix for the operability region, at atmospheric pressure. The main responses were extracted from the OH* images, because of its correlation with the flame heat release, these being the flame area and its average brightness, the heat release area and its center of gravity and leading edge. To assess the importance of the main factors and their interactions, an analysis of variance (ANOVA) was performed for each response, considering as significant each contributor with a p-value below 0.05. For these five responses it was found that all four main factors need to be included into the model (most of them because its own significance, others to ensure the model hierarchy), as well as some common interactions as the preheat and flame temperatures or pressure drop and fuel composition, and quadratic terms from fuel composition or flame temperature. Three of the five models presented R2 and coefficient of variance (C.V.) indicators around 0.97 and 5%, respectively; the leading edge ANOVA yielded into R2=0.78 and C.V.=18.88%; and the heat release area showed R2=0.91 and C.V.=24.13%. Lastly, the confinement ratio effect of the combustor over the flame structure was quantified, for three different conditions: the original 80 mm inner diameter and 200 mm length cylinder was compared against a shorter 150 mm tube (same inner diameter) and a narrower 47 mm inner diameter one (same 200 mm length). The length had a smaller effect than the inner diameter, even though both factors were not strong enough to make a significant deviation on most of the flame parameters: the difference was within the repeatability margin of error for the brightness, flame area, and center of gravity and leading edge of the heat release area.

Imaging diagnostics, flame characterization, OH* c↗

Additively manufactured multiplexed inertial coalescence filters

Multiphase flows often pose a significant challenge to the efficient and reliable design of thermofluidic systems. This paper describes multiplexed inertial coalescence filters composed of parallel helical pathways, designed to capture fine droplets (<40 µm) through inertial separation while maintaining a low pressure drop (<400 Pa). Filtration efficiencies for 7 µm and 30 µm droplets were characterized for varying flow conditions, with complete capture observed above a threshold flow rate. Models for filtration efficiency and pressure drop were developed and validated against experimental results to allow system design and optimization, enabled by the tunable additive manufacturing approach used to fabricate the filters. Filter quality factor was computed for varying droplet sizes, showcasing exceptional quality factor when compared to state-of-the-art filters documented in the literature. In conclusion, this multiplexed inertial coalescence filtration approach could find use in dehumidification systems, fog harvesting, chemical reactors, and microgravity droplet capture.

3D Printing↗

Dynamic analysis of a circulating fluidized bed riser

A linear state model is proposed to analyze dynamic behavior of a circulating fluidized bed riser. Different operating regimes were attained with high density polyethylene beads at low and high system inventories. The riser was operated between the classical choking velocity and the upper transport velocity demarcating fast fluidized and transport regimes. At a given riser superficial gas velocity, the aerations fed at the standpipe were modulated resulting in a sinusoidal solids circulation rate that goes into the riser via L-valve. The state model was derived based on the mass balance equation in the riser. It treats the average solids fraction across the entire riser as a state variable. The total riser pressure drop was modeled using Newton’s second law of motion. The momentum balance equation involves contribution from the weight of solids and the wall friction caused by the solids to the riser pressure drop. The weight of solids utilizes the state variable and hence, the riser inventory could be easily calculated. The modeling problem boils down to estimating two parameters including solids friction coefficient and time constant of the riser. It has been shown that the wall friction force acts in the upward direction in fast fluidized regime which indicates that the solids were moving downwards on the average with respect to the riser wall. In transport regimes, the friction acts in the opposite direction. This behavior was quantified based on a sign of Fanning friction factor in the momentum balance equation. The time constant of the riser appears to be much higher in fast fluidized regime than in transport conditions.

42 ENGINEERING↗

Filtration of bioaerosols using a granular metallic filter with micrometer-sized collectors

Several experimental studies with granular bed filters composed of micrometer-sized spherical or sintered metallic granules have demonstrated their use in aerosol filtration. However, the effectiveness of these metallic membrane filters against bioaerosols has not been established. In this work, the filtration efficiency and filter quality of these filters against airborne B. subtilis endospore and MS2 virus were determined as a function of face velocity and loading time. In experiments, a physical removal efficiency greater than 99.9% and a viable removal efficiency of greater than 5-log were observed for both bacterial spore and viral aerosols. A lower face velocity produced both higher collection efficiency and filter quality for virus but was not statistically significant for spore filtration. Although the filter had high filtration efficiency of the test bioaerosols, the filter's high pressure drop resulted in a low filter quality (0.25-0.75 kPa- 1). Overall, filters with micrometer-sized collectors capture bioaerosols effectively but their applications in aerosol filtration may be limited by their high pressure drop.

aerosol↗

Water Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design, fabricate, and test a preflight prototype pump for use in the Extravehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump will accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting noncondensable gas without becoming "air locked." The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the preflight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES will simulate the vacuum environment in which the flight pump will operate. Testing will verify that the pump meets design requirements for range of flow rates, pressure rise, power consumption, working fluid temperature, operating time, and restart capability. Pump testing is currently scheduled for March, 2009, after which the pump will be delivered to NASA for further testing.

Schuller, Michael↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

Hydrogen Sensor for Parabolic Trough Expansion Tanks

The National Renewable Energy Laboratory and Acciona Energy North America are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid. As part of this effort, we are developing a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor design measures hydrogen levels over a wide partial pressure range from 1.33 mbar down to 0.003 mbar with an accuracy of +/-20%. We acquired these results under limited conditions because we measured hydrogen partial pressure in gas mixtures of hydrogen and nitrogen only. In this paper, we report our most recent results in which we measured hydrogen partial pressures in gas mixtures that contain hydrogen, nitrogen, biphenyl, and diphenylether. Our results for this gas mixture were essentially the same as those obtained for the hydrogen/nitrogen mixture only, and they also had the same accuracy of +/-20%. This level of accuracy is sufficient to evaluate the performance of a hydrogen mitigation process because hydrogen partial pressure in the expansion tank decreases more than an order of magnitude when the mitigation process is operating. We examined the palladium/silver membrane after completing these measurements and did not observe any signs of membrane deterioration or contamination due to exposure to biphenyl and diphenylether at 405 degrees C. The membrane for these tests was 25 um thick. For the next sensor design that we are developing in 2018, we are using a membrane that is 127 um thick. This thickness is required for the membrane to withstand the 150 psi pressure drop across the membrane when exposed to actual headspace gas from the expansion tank. We performed initial tests in which we exposed a 127-um-thick palladium alloy membrane to 400 degrees C and 150 psi pressure drop and observed no signs of failure or gas leakage. Finally, we developed a transient model that accounts for hydrogen transport mechanisms within the sensor when measurements are made. Our model accounted for hydrogen diffusion through the boundary layer that is adjacent to the membrane and for hydrogen permeation across the membrane and into the permeate volume. Our modeling results agreed very closely with our experimental data when we assumed a boundary-layer thickness of 0.2 cm. This thickness is within the range of expected thicknesses for this gas composition, temperature, and pressure at minimum flowrate. Our model results showed that hydrogen diffusion through the boundary layer adjacent to the membrane is the rate-determining step for the transient pressure response when measuring hydrogen partial pressure.

14 SOLAR ENERGY↗

Design considerations for a micro-g superfluid helium fluid acquisition system

The general description, the operation, and the design of a superfluid helium (SFHe) fluid acquisition system (FAS) for use under microgravity conditions is presented. For the type of FAS considered here, where fine-mesh woven screens are used to retain flowing SFHe within a gallery arm (flow) channel, those forces which determine the flow dynamics are the micro-g accelerations, liquid surface tension, and tensile strength and cumulative pressure drops along a flow path that begins at the bulk liquid and ends at the entrance to a pump. For this case, the dimensionless number, N(T) is written as the ratio between the pressure drop across the screen and the surface tension forces at the screen for low fluid velocities. Static Bond number measurements have bene taken for SFHe using 325 x 2300 twilled Dutch screen and have indicated a screen pore hydraulic radius of 0.00031 cm.

Lee, J. M.↗

RP-1 Thermal Stability and Copper Based Materials Compatibility Study

A series of electrically heated tube tests was performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the effect that sulfur content, test duration, and tube material play in the overall thermal stability and materials compatibility characteristics of RP-1. Scanning-electron microscopic (SEM) analysis in conjunction with energy dispersive spectroscopy (EDS) were used to characterize the condition of the tube inner wall surface and any carbon deposition or corrosion formed during these runs. Results of the parametric study indicate that tests with standard RP-1 (total sulfur -23 ppm) and pure copper tubing are characterized by a depostion/deposit shedding process producing local wall temperature swings as high as 500 F. The effect of this shedding is to keep total carbon deposition levels relatively constant for run times from 20 minutes up to 5 hours, though increasing tube pressure drops were observed in all runs. Reduction in the total sulfur content of the fuel from 23 ppm to less than 0.1 ppm resulted in the elimination of deposit shedding, local wall temperature variation, and the tube pressure drop increases that were observed in standard sulfur level RP-1 tests. The copper alloy GRCop-84, a copper alloy developed specifically for high heat flux applications, was found to exhibit higher carbon deposition levels compared to identical tests performed in pure copper tubes. Results of the study are consistent with previously published heated tube data which indicates that small changes in fuel total sulfur content can lead to significant differences in the thermal stability of kerosene type fuels and their compatibility with copper based materials. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-1.

Stiegemeier, B. R.↗

Effect of Exit-Slot Position and Opening on the Available Cooling Pressure for NACA Nose-Slot Cowlings

Report presents the results of an investigation of full-scale nose-slot cowlings conducted in the NACA 20-foot wind tunnel to furnish information on the pressure drop available for cooling. Engine conductances from 0 to 0.12 and exit-slot conductances from 0 to 0.30 were covered. Two basic nose shapes were tested to determine the effect of the radius of curvature of the nose contour; the nose shape with the smaller radius of curvature gave the higher pressure drop across the engine. The best axial location of the slot for low-speed operation was found to be in the region of maximum negative pressure for the basic shape for the particular operating condition. The effect of the pressure operating condition on the available cooling pressure is shown.

Stickle, George W↗

Computational fluid dynamic analysis of a novel particle-to-air fluidized-bed heat exchanger for particle-based thermal energy storage applications

Long-duration energy storage technologies are being targeted to enable cost-effective, decarbonized energy systems. Particle-based thermal energy storage systems are one promising technology by storing excess electricity or heat as sensible thermal energy in inexpensive, solid, inert particles. These systems are only possible if an effective and economical particle-to-working fluid heat exchanger exists. This study predicts the performance of a proposed, direct-contact, particle-to-air, pressurized fluidized-bed heat exchanger using computational fluid dynamics. The common Eulerian-Eulerian framework for modeling fluidized beds is first benchmarked to experimental results at a previously untested operating condition and application. Then, the benchmarked model evaluates the performance of a proposed design for a commercial-scale version of the novel particle-to-air heat exchanger. The results show pressure drop and gas-phase approach temperatures are advantageous compared to other proposed designs for particle-to-air heat exchangers in the literature; approach temperatures were less than 5 °C and gas-phase pressure drop across the fluidized bed was 32 kPa. The model also highlights the importance of gas distributor design and representation in the Eulerian-Eulerian framework to control fluidization behavior. In conclusion, the model built and benchmarked in this study can be leveraged to advance the design and analysis of these heat exchangers critical to the deployment of a promising long-duration energy storage technology.

25 ENERGY STORAGE↗