Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLLUTION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Application of Ultrasonic for Decontamination of Contaminated Soil - 13142

The trials of soil decontamination were carried out with the help of a pilot ultrasonic installation in different modes. The installation included a decontamination bath equipped with ultrasonic sources, a precipitator for solution purification from small particles (less than 80 micrometer), sorption filter for solution purification from radionuclides washing out from soil, a tank for decontamination solution, a pump for decontamination solution supply. The trials were carried out on artificially contaminated sand with specific activity of 4.5 10{sup 5} Bk/kg and really contaminated soil from Russian Scientific Center 'Kurchatovsky Institute' (RSC'KI') with specific activity of 2.9 10{sup 4} Bk/kg. It was established that application of ultrasonic intensify the process of soil reagent decontamination and increase its efficiency. The decontamination factor for the artificially contaminated soil was ∼200 and for soil from RSC'KI' ∼30. The flow-sheet diagram has been developed for the new installation as well as determined the main technological characteristics of the equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Evaluation of Cesium Distribution for Wet Sieving Process Planned for Soil Decontamination in Japan - 13104

For the purpose of decontaminating radioactive cesium from a huge amount of soil, which has been estimated to be 1.2x10{sup 8} m{sup 3} by excavating to a 5-cm depth from the surface of Fukushima Prefecture where a severe nuclear accident occurred at TEPCO's power generating site and has emitted a significant amount of radioactive materials, mainly radioactive cesium, a wet sieving process was selected as one of effective methods available in Japan. Some private companies have demonstrated this process for soil treatment in the Fukushima area by testing at their plants. The results were very promising, and a full-fledged application is expected to follow. In the present study, we spiked several aqueous samples containing soil collected from an industrial wet sieving plant located near our university for the recycling of construction wastes with non-radioactive cesium hydroxide. The present study provides scientific data concerning the effectiveness in volume reduction of the contaminated soil by a wet sieving process as well as the cesium distribution between the liquid phase and clay minerals for each sub-process of the full-scale one, but a simulating plant equipped with a process of coagulating sedimentation and operational safety fundamentals for the plant. Especially for the latter aspect, the study showed that clay minerals of submicron size strongly bind a high content of cesium, which was only slightly removed by coagulation with natural sedimentation (1 G) nor centrifugal sedimentation (3,700 G) and some of the cesium may be transferred to the effluent or recycled water. By applying ultracentrifugation (257,000 G), most of submicron clay minerals containing cesium was removed, and the cesium amount which might be transferred to the effluent or recycled water, could be reduced to less than 2.3 % of the original design by the addition of a cesium barrier consisting of ultracentrifugation or a hollow fiber membrane. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced process engineering co-simulation using CFD-based reduced order models

The process and energy industries face the challenge of designing the next generation of plants to operate with unprecedented efficiency and near-zero emissions, while performing profitably amid fluctuations in costs for raw materials, finished products, and energy. To achieve these targets, the designers of future plants are increasingly relying upon modeling and simulation to create virtual plants that allow them to evaluate design concepts without the expense of pilot-scale and demonstration facilities. Two of the more commonly used simulation tools include process simulators for describing the entire plant as a network of simplified equipment models and computational fluid dynamic (CFD) packages for modeling an isolated equipment item in great detail by accounting for complex thermal and fluid flow phenomena. The Advanced Process Engineering Co-Simulator (APECS) sponsored by the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) has been developed to combine process simulation software with CFD-based equipment simulation software so that design engineers can analyze and optimize the coupled fluid flow, heat and mass transfer, and chemical reactions that drive overall plant performance (Zitney et al., 2006). The process/CFD software integration was accomplished using the process-industry standard CAPE-OPEN interfaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable Scientists

Scientists are front and center in quantifying and solving environmental problems. Yet, as a spate of recent news articles in scientific journals point out, much can be done to enhance sustainability within the scientific enterprise itself, particularly by trimming the energy use associated with research facilities and the equipment therein (i,ii,iii, iv). Sponsors of research unwittingly spend on the order of $10 billion each year on energy in the U.S. alone, and the underlying inefficiencies drain funds from the research enterprise while causing 80 MT CO2-equivalent greenhouse-gas emissions (see Box). These are significant sums considering the opportunity costs in terms of the amount of additional research that could be funded and emissions that could be reduced if the underlying energy was used more efficiently. By following commercially proven best practices in facility design and operation, scientists--and the sponsors of science--can cost-effectively halve these costs, while doing their part to put society on alow-carbon diet.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effects of Rapid High Temperature Cyclic Aging on a Fully-Formulated Lean NOx Trap Catalyst

In this study, high-temperature deactivation of a fully-formulated lean NOx trap (LNT) is investigated with an accelerated aging protocol where accelerated aging is accomplished by rapid temperature cycling and by higher temperatures. Thermal aging is carried out in a bench-flow reactor at nominal temperatures of 700, 800, 900, and 1000 C using an aging cycle consisting of a 130s lean-phase and a 50s rich-phase. After a prescribed number of lean/rich aging cycles, the NOx conversion of the aged LNT is evaluated at 200, 300, and 400 C. The NOx performance is obtained at a GHSV of 30,000 h-1 using an evaluation cycle consisting of a 60s lean-phase and 5s rich-phase. The effects of aging on the LNT washcoat are determined with EPMA, XRD, STEM/EDS, and BET. Aging at 700 and 800 C has a minimal effect on LNT performance and material properties. However, at aging temperatures of 900 and 1000 C reduction in surface area and sintering of PGM particles are observed and result in a drastic reduction in NOx conversion. Additionally, after aging at 900 C and 1000 C the NOx storage medium, BaCO3, is no longer visible in the XRD patterns, even though a Ba-phase identified by EPMA still exists in all aged samples. BaAl2O4 is not identified at any aging temperatures; possibly due to stabilization effects provided by washcoat additives present in this particular LNT.

33 ADVANCED PROPULSION SYSTEMS↗

Silver doped catalysts for treatment of exhaust

A method of making an exhaust treatment element includes washcoating a substrate with a slurry that includes a catalyst support material. At least some of the catalyst support material from the slurry may be transferred to the substrate, and silver metal (Ag) is dispersed within the catalyst support material.

33 ADVANCED PROPULSION SYSTEMS↗

Characterization of Field-Aged EGR Cooler Deposits

Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with NOx emissions standards. In order to better understand fouling mechanisms, eleven field-aged EGR coolers provided by seven different engine manufacturers were characterized using a suite of techniques. Microstructures were characterized using scanning electron microscopy (SEM) and optical microscopy following mounting the samples in epoxy and polishing. Optical microscopy was able to discern the location of hydrocarbons in the polished cross-sections. Chemical compositions were measured using thermal gravimetric analysis (TGA), differential thermal analysis (DTA), gas chromatography-mass spectrometry (GC-MS), x-ray photoelectron spectroscopy (XPS), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). Mass per unit area along the length of the coolers was also measured. Despite coming from different sources and applications, many common features were observed in the cooler deposits including mud-cracking, hydrocarbon condensation near the metal surface, and erosion of the deposit. Differences and commonalities between the coolers will be discussed in the context of better understanding cooler fouling and ways to prevent it.

33 ADVANCED PROPULSION SYSTEMS↗

Pulmonary nodules in workers exposed to urban stressor

By multilayer spiral low-dose computed tomography (LD-CT) of the chest this study assesses the early detection of lung lesions on a sample of 100 traffic policemen of a big Italian city professionally exposed to urban pollutants and 100 controls non-occupationally exposed to urban pollutants matched by sex, age, length of service and cigarette smoking habit. Exposure to urban pollutants in traffic policemen was characterized using the annual average concentrations of PM{sub 10}, NO{sub 2} and benzene in the period 1998-2008 measured by fixed monitoring stations located in different areas of the city. A significant and increasing number of suspicious lung nodules with diameters between 5 and 10 mm was observed: in traffic policemen (including smokers and non-smokers) vs. controls (including smokers and non-smokers); in total smokers (including traffic policemen and controls) vs. total non-smokers (traffic policemen and controls); in smoker traffic policemen vs. smoker controls and vs. non-smoker traffic policemen; in non-smoker traffic policemen vs. non-smoker controls. The RR of finding cases with at least one lung nodule with diameters between 5 and 10 mm in traffic policemen (including smokers and non-smokers) compared to controls (including smokers and non-smokers) is 1.94 (CI 1.13-3.31); in total smokers vs. non-smokers the RR is 1.96 (CI 1.20-3.19). The comparison between the interaction exposure and smoking shows an increase in smoker traffic policemen than in smoker controls (RR=2.14; CI 1.02-4.52). The RR for smoker traffic policemen was higher than in non-smoker traffic policemen (RR=2.09; CI 1.19-3.66). The results of our study show that: (1) while smoker workers have a higher risk for developing solid suspicious lung nodules, the simple routinely exposure to urban pollutants is unable to produce the same kind of increased risk; (2) the interaction of smoking and exposure to urban pollutants greatly increases the risk for the development of solid suspicious lung nodules. In conclusion, the use of chest LD-CT in workers at risk helps identify suspicious solid lung nodules at early stage.

60 APPLIED LIFE SCIENCES↗

Assessing and controlling the effect of aircraft on the environment: Pollution

The air pollution created by aircraft engines around airports and the global atmospheric problem of supersonic aircraft operating in the stratosphere are discussed. Methods for assessing the air pollution impact are proposed. The use of atmospheric models to determine the air pollution extent is described. Methods for controlling the emissions of aircraft engines are examined. Diagrams of the atmospheric composition resulting from exhaust gas emissions are developed.

Poppoff, I. G.↗

America's top fifty power plant mercury pollutants

The fifty most-polluting coal-burning power plants in the United States emitted twenty tons of mercury into the air in 2007. Of the ten highest-emitting plants, all but one reported an increase as compared to 2006. Coal-fired power plants are the single largest source of mercury air pollution in the U.S., accounting for roughly 40 per cent of all mercury emissions. This report rates the power plants both in terms of sheer mercury pollution and mercury pollution adjusted per kilowatt hour. It also outlines the ways in which mercury removal is achievable with existing technology. Activated carbon injection, which is commercially available and has been tested, can achieve mercury reductions of 90 per cent (and better when coupled with a fabric filter for particulate control) on both bituminous and sub-bituminous coals. In addition, mercury can be significantly reduced as a 'co-benefit' of controls for other pollutants, such as fabric filters, flue gas desulphurization, and selective catalytic reduction. 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Development of Smart Ventilation Control Algorithms for Humidity Control in High-Performance Homes in Humid U.S. Climates

Past field research and simulation studies have shown that high performance homes experience elevated indoor humidity levels for substantial portions of the year in humid climates. This is largely the result of lower sensible cooling loads, which reduces the moisture removed by the cooling system. These elevated humidity levels lead to concerns about occupant comfort, health and building durability. Use of mechanical ventilation at rates specified in ASHRAE Standard 62.2-2013 are often cited as an additional contributor to humidity problems in these homes. Past research has explored solutions, including supplemental dehumidification, cooling system operational enhancements and ventilation system design (e.g., ERV, supply, exhaust, etc.). This project’s goal is to develop and demonstrate (through simulations) smart ventilation strategies that can contribute to humidity control in high performance homes. These strategies must maintain IAQ via equivalence with ASHRAE Standard 62.2-2013. To be acceptable they must not result in excessive energy use. Smart controls will be compared with dehumidifier energy and moisture performance. This work explores the development and performance of smart algorithms for control of mechanical ventilation systems, with the objective of reducing high humidity in modern high performance residences. Simulations of DOE Zero-Energy Ready homes were performed using the REGCAP simulation tool. Control strategies were developed and tested using the Residential Integrated Ventilation (RIVEC) controller, which tracks pollutant exposure in real-time and controls ventilation to provide an equivalent exposure on an annual basis to homes meeting ASHRAE 62.2-2013. RIVEC is used to increase or decrease the real-time ventilation rate to reduce moisture transport into the home or increase moisture removal. This approach was implemented for no-, one- and two-sensor strategies, paired with a variety of control approaches in six humid climates (Miami, Orlando, Houston, Charleston, Memphis and Baltimore). The control options were compared to a baseline system that supplies outdoor air to a central forced air cooling (and heating) system (CFIS) that is often used in hot humid climates. Simulations were performed with CFIS ventilation systems operating on a 33% duty-cycle, consistent with 62.2-2013. The CFIS outside airflow rates were set to 0%, 50% and 100% of 62.2-2013 requirements to explore effects of ventilation rate on indoor high humidity. These simulations were performed with and without a dehumidifier in the model. Ten control algorithms were developed and tested. Analysis of outdoor humidity patterns facilitated smart control development. It was found that outdoor humidity varies most strongly seasonally—by month of the year—and that all locations follow the similar pattern of much higher humidity during summer. Daily and hourly variations in outdoor humidity were found to be progressively smaller than the monthly seasonal variation. Patterns in hourly humidity are driven by diurnal daily patterns, so they were predictable but small, and were unlikely to provide much control benefit. Variation in outdoor humidity between days was larger, but unpredictable, except by much more complex climate models. We determined that no-sensor strategies might be able to take advantage of seasonal patterns in humidity, but that real-time smart controls were required to capture variation between days. Sensor-based approaches are also required to respond dynamically to indoor conditions and variations not considered in our analysis. All smart controls face trade-offs between sensor accuracy, cost, complexity and robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Remote Sensing of Water Pollution

Remote sensing, as a tool to aid in the control of water pollution, offers a means of making rapid, economical surveys of areas that are relatively inaccessible on the ground. At the same time, it offers the only practical means of mapping pollution patterns that cover large areas. Detection of oil slicks, thermal pollution, sewage, and algae are discussed.

White, P. G.↗