Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Approaching perfect microwave photodetection in circuit QED

In order to apply all ideas from quantum optics to the field of quantum circuits, one of the missing ingredients is a high-efficiency single-photon detector. In this work we propose a design for such a device which successfully reaches 100% efficiency with only one absorber. Our photon detector consists of a three-level system (a phase qubit) coupled to a semi-infinite one-dimensional waveguide (a microwave transmission line) which performs highly efficient photodetection in a simplified manner as compared to previous proposals. Using the tools of quantum optics we extensively study the scattering properties of realistic wave packets against this device, thereby computing the efficiency of the detector. We find that the detector has many operating modes, can detect detuned photons, is robust against design imperfections, and can be made broadband by using more than one absorbing element in the design. Many of these ideas could be translated to other single-mode photonic or plasmonic waveguides interacting with three-level atoms or quantum dots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modified gravitational wave propagation with higher modes and its degeneracies with lensing

Low-energy alternatives to General Relativity (GR) generically modify the phase of gravitational waves (GWs) during their propagation. As detector sensitivities increase, it becomes key to understand how these modifications affect the GW higher modes and to disentangle possible degeneracies with astrophysical phenomena. We apply a general formalism — the WKB approach — for solving analytically wave propagation in the spatial domain with a modified dispersion relation (MDR). We compare this WKB approach to applying a stationary phase approximation (SPA) in the temporal domain with time delays associated to the group or particle velocity. To this end, we extend the SPA to generic signals with higher modes, keeping careful track of reference phases and arrival times. We find that the WKB approach coincides with the SPA using the group velocity, in agreement with the principles of wave propagation. We then explore the degeneracies between a GW propagation with an MDR and a strongly-lensed GW in GR, since the latter can introduce a frequency-independent phase shift which is not degenerate with source parameters in the presence of higher modes. We find that for a particular MDR there is an exact degeneracy for wave propagation, unlike with the SPA for particle propagation. For the other cases, we search for the values of the MDR parameters that minimize the χ 2 and conclude that strongly-lensed GR GWs could be misinterpreted as GWs in modified gravity. As a result, future MDR constraints with higher mode GWs should include the possibility of frequency-independent phase shifts, allowing for the identification of modified gravity and strong lensing distortions at the same time.

79 ASTRONOMY AND ASTROPHYSICS↗

Composite CaWO{sub 4} Detectors for the CRESST-II Experiment

CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of a tungsten thin-film structure evaporated onto the CaWO{sub 4} absorber crystal. The process of evaporation causes a decrease in the scintillation light output. This, together with the need of a big-scale detector production for the upcoming EURECA experiment lead to investigations for producing thermometers on smaller crystals which are glued onto the absorber crystal. In our Run 31 we tested composite detectors for the first time in the Gran Sasso setup. They seem to produce higher light yields as hoped and could provide an additional time based discrimination mechanism for low light yield clamp events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All electrical propagating spin wave spectroscopy with broadband wavevector capability

We developed an all electrical experiment to perform the broadband phase-resolved spectroscopy of propagating spin waves in micrometer sized thin magnetic stripes. The magnetostatic surface spin waves are excited and detected by scaled down to 125 nm wide inductive antennas, which award ultra broadband wavevector capability. The wavevector selection can be done by applying an excitation frequency above the ferromagnetic resonance. Wavevector demultiplexing is done at the spin wave detector thanks to the rotation of the spin wave phase upon propagation. A simple model accounts for the main features of the apparatus transfer functions. Our approach opens an avenue for the all electrical study of wavevector-dependent spin wave properties including dispersion spectra or non-reciprocal propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗

Beta/gamma and alpha backgrounds in CRESST-II Phase 2

The experiment CRESST-II aims at the detection of dark matter with scintillating CaWO{sub 4} crystals operated as cryogenic detectors. Recent results on spin-independent WIMP-nucleon scattering from the CRESST-II Phase 2 allowed to probe a new region of parameter space for WIMP masses below 3 GeV/c{sup 2}. This sensitivity was achieved after background levels were reduced significantly. We present extensive background studies of a CaWO{sub 4} crystal, called TUM40, grown at the Technische Universität München. The average beta/gamma rate of 3.51/[kg keV day] (1-40 keV) and the total intrinsic alpha activity from natural decay chains of 3.08±0.04 mBq/kg are the lowest reported for CaWO{sub 4} detectors. Contributions from cosmogenic activation, surface-alpha decays, external radiation and intrinsic alpha/beta emitters are investigated in detail. A Monte-Carlo based background decomposition allows to identify the origin of the majority of beta/gamma events in the energy region relevant for dark matter search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance study of a 3×1×1 m 3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m 3 ) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved X-ray emission measurements of the residual velocity during the stagnation phase of inertial confinement fusion implosion experiments

A technique for measuring residual motion during the stagnation phase of an indirectly driven inertial confinement experiment has been implemented. This method infers a velocity from spatially and temporally resolved images of the X-ray emission from two orthogonal lines of sight. This work investigates the accuracy of recovering spatially resolved velocities from the X-ray emission data. A detailed analytical and numerical modeling of the X-ray emission measurement shows that the accuracy of this method increases as the displacement that results from a residual velocity increase. For the typical experimental configuration, signal-to-noise ratios, and duration of X-ray emission, it is estimated that the fractional error in the inferred velocity rises above 50% as the velocity of emission falls below 24 μm/ns. By inputting measured parameters into this model, error estimates of the residual velocity as inferred from the X-ray emission measurements are now able to be generated for experimental data. Details of this analysis are presented for an implosion experiment conducted with an unintentional radiation flux asymmetry. The analysis shows a bright localized region of emission that moves through the larger emitting volume at a relatively higher velocity towards the location of the imposed flux deficit. This technique allows for the possibility of spatially resolving velocity flows within the so-called central hot spot of an implosion. This information would help to refine our interpretation of the thermal temperature inferred from the neutron time of flight detectors and the effect of localized hydrodynamic instabilities during the stagnation phase. Across several experiments, along a single line of sight, the average difference in magnitude and direction of the measured residual velocity as inferred from the X-ray and neutron time of flight detectors was found to be ∼13 μm/ns and ∼14°, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ANNIE Phase I: Neutron Background Measurements

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton Gd-doped water Cherenkov detector installed in the Booster Neutrino Beam (BNB) at Fermilab. The primary physics goal of ANNIE is to study the multiplicity of final state neutrons from neutrino-nucleus interactions in water. Identifying and counting final state neutrons provides a new experimental handle to study systematic uncertainties related to the neutrino energy reconstruction in oscillation experiments. To achieve that goal ANNIE will make the first use of the novel Large Area Picosecond PhotoDetectors (LAPPDs). In Phase I, ANNIE characterised the beam-correlated neutron backgrounds in the detector and confirmed that they are sufficiently low for the Phase II physics measurements, anticipated to begin in 2019. In these proceesings the methodology and the results of Phase I will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of top-quark pair production in association with charm quarks in proton–proton collisions at √s = 13 TeV with the ATLAS detector

Inclusive cross-sections or top-quark pair production in association with charm quarks are measured with proton-proton collision data at a center-of-mass energy of 13 TeV corresponding to an integrated luminosity of 140 fb -1 , collected with the ATLAS experiment at LHC between 2015 and 2018. The measurements are performed by requiring one or two charged leptons (electrons and muons), two b-tagged jets, and at least one additional jet in the final state. A custom flavor-tagging algorithm is employed for the simultaneous identification of b-jets and c-jets. In a fiducial phase space that replicates the acceptance of the ATLAS detector, the cross-sections for $t\bar{t}$ + ≥ 2c and $t\bar{t}$ + 1c production are measured to be $1.28^{+0.27}_{-0.24}$ pb and $6.4^{+1.0}_{-0.9}$ pb, respectively. The measurements are primarily limited by uncertainties in the modeling of inclusive $t\bar{t}$ and $t\bar{t}$ + $b\bar{b}$ production, in the calibration of the flavor-tagging algorithm, and by data statistics. Cross-section predictions from various $t\bar{t}$ simulations are largely consistent with the measured cross-section values, though all underpredict the observed values by 0.5 to 2.0 standard deviations. In a phase-space volume without requirements on the $t\bar{t}$ decay products and the jet multiplicity, the cross-section ratios of $t\bar{t}$ + ≥ 2c and $t\bar{t}$ + 1c to total $t\bar{t}$ + jets production are determined to be (1.23 ± 0.25)% and (8.8 ± 1.3)%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The PICASSO Dark Matter Experiment

The PICASSO experiment searches for cold dark matter through the direct detection of weakly interacting massive particles (WIMPs) via their spin-dependent interactions with fluorine at SNOLAB, Sudbury--ON, Canada since 2002. The detection principle is based on the superheated droplet technique; the detectors consist of a gel matrix with millions of liquid droplets of superheated fluorocarbon (C4F10) dispersed in it. Recently, a new setup has been built and installed in the Ladder Lab area at SNOLAB. In the present phase of the experiment the Collaboration is running 4.5-litre detector modules with approximately 85 g of active mass per module. Here, we give an overview of the experiment and discuss the progress in background mitigation, in particular background discrimination in the PICASSO detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Decays $B_d \to J/\psi+ K^*$ and $B_s \to J/\psi+ \phi$ with the D0 detector

We present measurements of the linear polarization amplitudes and the strong relative phases that describe the flavor-untagged decays B{sub d} {yields} J/{Psi} K* and B{sub s} {yields} J/{Psi}{phi} in the transversity basis. We also measure the mean lifetime of the B{sub s} mass eigenstates and the lifetime ratio. The analyses are based on approximately 2.8 fb{sup -1} of data recorded with the D0 detector. From our measurements of the angular parameters we conclude that there is no evidence for a deviation from flavor SU(3) symmetry for these decays and that the factorization assumption is not valid for the B{sub d} {yields} J/{Psi} K* decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Terrestrial Search for Dark Contents of the Vacuum, Such as Dark Energy, Using Atom Interferometry

We describe the theory and first experimental work on our concept for searching on earth for the presence of dark contents of the vacuum (DCV) using atom interferometry. Specifically, we have in mind any DCV that has not yet been detected on a laboratory scale, but which might manifest itself as dark energy on the cosmological scale. The experimental method uses two atom interferometers to cancel the effect of earth's gravity and diverse noise sources. It depends upon two assumptions: first, that the DCV possesses some space inhomogeneity in density, and second that it exerts a sufficiently strong nongravitational force on matter. The motion of the apparatus through the DCV should then lead to an irregular variation in the detected matter-wave phase shift. We discuss the nature of this signal and note the problem of distinguishing it from instrumental noise. We also discuss the relation of our experiment to what might be learned by studying the noise in gravitational wave detectors such as LIGO. The paper concludes with a projection that a future search of this nature might be carried out using an atom interferometer in an orbiting satellite. The laboratory apparatus is now being constructed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Practical aspects of diffractive imaging using an atomic-scale coherent electron probe

Four-dimensional scanning transmission electron microscopy (4D-STEM) is a technique where a full two-dimensional convergent beam electron diffraction (CBED) pattern is acquired at every STEM pixel scanned. Capturing the full diffraction pattern provides a rich dataset that potentially contains more information about the specimen than is contained in conventional imaging modes using conventional integrating detectors. In this work, using 4D datasets in STEM from two specimens, monolayer MoS 2 and bulk SrTiO 3 , we demonstrate multiple STEM imaging modes on a quantitative absolute intensity scale, including phase reconstruction of the transmission function via differential phase contrast imaging. Finally, practical issues about sampling (i.e. number of detector pixels), signal-to-noise enhancement and data reduction of large 4D-STEM datasets are emphasized.

36 MATERIALS SCIENCE↗

Layout and assembly technique of the GEM chambers for the upgrade of the CMS first muon endcap station

Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future High-Luminosity phase of the Large Hadron Collider (HL-LHC). In a first step, GEM chambers (detectors) will be installed in the innermost muon endcap station in the 1.6<|η|<2.2 pseudo-rapidity region, mainly to control level-1 muon trigger rates after the second LHC Long Shutdown. These new chambers will add redundancy to the muon system in the η-region where the background rates are high, and the bending of the muon trajectories due to the CMS magnetic field is small. A novel construction technique for such chambers has been developed in such a way where foils are mounted onto a single stack and then uniformly stretched mechanically, avoiding the use of spacers and glue inside the active gas volume. We describe the layout, the stretching mechanism and the overall assembly technique of such GEM chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R&D Adoption and Progress in Full Simulation of the CMS experiment

In this work we report on evolution of usage of Geant4 within CMSSW and adaptation of the newest Geant4 11.2.1, which is expected to be used for CMS simulation production in 2025. Physics validation results and results on CPU performance are reported. For the Phase-2 simulation several R&D are carried out. A significant update for CMS geometry description is performed. Different aspects of geometry description and physics simulation for the new detectors will be discussed. Progress on R&D efforts for the Phase-2 simulation will be presented, which includes reports on experience of application of G4HepEm external library.

Srimanobhas, Norraphat [Chulalongkorn U.]↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

FACET: a new long-lived particle detector in the very forward region of the CMS experiment

We describe a proposal to add a set of very forward detectors to the CMS experiment for the high-luminosity era of the Large Hadron Collider to search for beyond the standard model long-lived particles, such as dark photons, heavy neutral leptons, axion-like particles, and dark Higgs bosons. The proposed subsystem is called FACET for Forward-Aperture CMS ExTension, and will be sensitive to any particles that can penetrate at least 50 m of magnetized iron and decay in an 18 m long, 1 m diameter vacuum pipe. The decay products will be measured in detectors using identical technology to the planned CMS Phase-2 upgrade.

Particle and Resonance Production↗