Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Multiwavelength monolithic integrated fiber-optic terminal

The paper presents the Multiwavelength Monolithic Integrated Fiber Optic Terminal (MMIFOT) developed under NASA sponsorship. The program aims to utilize the advantage of optical fiber and integrated optical device technology to achieve parallel transmission of many data channels over the same optical fiber link, and to develop an eight channel wavelength multiplexed fiber optic link that transmits eight bit words in a parallel format at a nominal rate of 20 Mw/s; in the second phase of the program a transmitter/multiplexer chip will be developed. The MMIFOT configuration, the receiver/demultiplexer development, and the waveguide detector development are discussed, concluding that the first phase of the MMIFOT program will culminate in the demonstration of an eight channel receiver/demultiplexer chip with a four channel breadboard multiplexer with the data rate of 20 Mbps per channel with a dynamic range of minimum 20 dB.

Rice, R. R.↗

Failure Detector for Power-Factor Controller

New protective circuits have been developed for power-factor ac motor controllers. Circuits prevent direct current and consequent motor heating that would normally result from failure of solid-state switch in controller. Single-phase power-factor controller with short detector compensates for short-circuit failure in either direction by applying full power to motor. Controller with open detector compensates for open-circuit failure in either direction by turning off power to motor.

Nola, F. J.↗

Multi-phase characterization of pitch-carbon coated nano-silicon anodes for lithium-ion batteries

Silicon (Si) is a leading next-generation Li-ion battery anode candidate that meets rigorous performance demands for portable power including enhanced power and energy density with robust cycling performance. However, a series of complex and interrelated reactions lead to reduced calendar life in Si-containing systems and therefore challenge practical adoption. In the present work, we probe the mechanisms underlying observed performance improvements by adding a pitch-carbon coating onto nano-Si material. We pair solid-phase (X-ray photoemission spectroscopy, Fourier-transform infrared), semi-volatile phase (solid-phase microextraction-gas chromatography-mass spectrometry), and gas-phase (gas chromatography-flame-ionization detector) characterization signals to comprehensively evaluate the impact of pitch-carbon coating on the evolution of the Si solid-electrolyte interphase (SEI) and the associated impacts on electrode/electrolyte reactivity. The pitch-carbon is found to serve as a physicochemical barrier, reducing the electro-active surface area for Si/electrolyte reactivity and preventing Si oxidation. Further, the pitch-carbon coating promotes the evolution of a more-favorable SEI by subsuming substantial functionality typically associated with the fluoroethylene carbonate (FEC) electrolyte additive - such as alkoxide scavenging and suppression of transesterification pathways - and by shifting the competitive electrolyte degradation pathways' favorability. The multi-phase characterization approach enables holistic end-products evaluation from complex (electro)chemical interfacial reactions, which informs a robust interpretation of the carbon coating's role in electrochemical performance improvements. The present mechanistic evaluation aids the rational design for improved nano-Si materials.

25 ENERGY STORAGE↗

Phase transformation and growth mechanism of RF sputtered ferroelectric lead scandium tantalate (PbSc 0.5 Ta 0.5 O 3 ) films

Lead scandium tantalate (PbSc 0.5 Ta 0.5 O 3 , PST), an order/disorder ferroelectric, is a potential candidate for electrocaloric cooling and pyroelectric infrared (IR) detector. In this work, we report the phase transformation kinetics from two series of samples containing pure amorphous and mixture of amorphous and pyrochlore to desired perovskite phase using postdeposition rapid thermal processing (RTP) as well as growth mechanism of RF sputtered PST thin films using excess lead target on platinized silicon (Pt/Ti/SiO 2 /Si) substrates. We find that small changes in the temperature ramp have a large effect on the degree of perovskite conversion (ferroelectric phase), orientation (crystallographic texture), and long-range order parameter (< S 111 >). Through isothermal annealing, we obtained optimal perovskite phase at ≥700°C temperature. The phase transformation is characterized by spontaneous formation of center-type in-plane radial rosette-like structures revealed by scanning electron microscopy. The PST perovskite crystallites were found to coexist with pyrochlore in RTP annealed films. The volume fractions for perovskite and pyrochlore phase were obtained from the analysis of “rosettes” and respective X-ray diffraction intensities which helped to determine various parameters associated with phase kinetics (n, k, and activation energy, Ea) and accompanying growth. The effective activation energies of perovskite transition and growth were found to be 332 ± 11 kJ/mol (345 ± 11 kJ/mol) and 114 ± 10 kJ/mol (122 ± 10 kJ/mol), respectively, for pure amorphous only (and mixed amorphous and pyrochlore) phase following nucleation-growth controlled Avrami's equation. A linear growth rate (n~1) for the perovskite phase indicates predominant interface-controlled process and diffusion-limited phenomena thus inhibiting rosette size owing to reactant depletion and soft impingement at the grain boundary. However, the growth behavior is isotropic in two-dimension parallel to the plane of the substrates for both sample series. Furthermore, lead loss was severe for in-situ growth and RTP combined with conventional furnace annealing than those of RTP only films, which were closer to stoichiometric albeit with excess lead and marginal oxygen vacancies (V o ).

36 MATERIALS SCIENCE↗

Harnessing the power of an X-ray laser for serial crystallography of membrane proteins crystallized in lipidic cubic phase

Serial femtosecond crystallography (SFX) with X-ray free-electron lasers (XFELs) has proven highly successful for structure determination of challenging membrane proteins crystallized in lipidic cubic phase; however, like most techniques, it has limitations. Here we attempt to address some of these limitations related to the use of a vacuum chamber and the need for attenuation of the XFEL beam, in order to further improve the efficiency of this method. Using an optimized SFX experimental setup in a helium atmosphere, the room-temperature structure of the adenosine A 2A receptor (A 2A AR) at 2.0 Å resolution is determined and compared with previous A 2A AR structures determined in vacuum and/or at cryogenic temperatures. Specifically, the capability of utilizing high XFEL beam transmissions is demonstrated, in conjunction with a high dynamic range detector, to collect high-resolution SFX data while reducing crystalline material consumption and shortening the collection time required for a complete dataset. The experimental setup presented herein can be applied to future SFX applications for protein nanocrystal samples to aid in structure-based discovery efforts of therapeutic targets that are difficult to crystallize.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DUNENDGGD: A Geometry Generator for DUNE Near Detector Design

The Deep Underground Neutrino Experiment (DUNE) is a long-baselineneutrino oscillation experiment aiming at measuring the CP-violation phase in an unprecedented precision.A liquid argon time projection chamber (TPC) far detector and a near detector system are considered.The near detector complex will consist of various components since we are aiming at a good phase space coverage of the neutrino events. A geometry generation tool, DUNENDGGD, is developed based on the general geometry description (GeGeDe). DUNENDGGD has a great flexibility to generate different detector and tracker combinations, therefore, the tool has been widely used in the DUNE near detector working group to design the DUNE near detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and recent results of the BAIKAL-GVD project

The Prototyping phase of the BAIKAL-GVD project has been started in April 2011 with the deployment of first autonomous engineering array which comprises all basic elements and systems of the Gigaton Volume Detector (GVD) in Lake Baikal. The prototyping phase will be concluded with deployment of the GVD demonstration cluster “DUBNA” in 2015, which will comprise 192 light sensors arranged at 8 strings. The first stage of the GVD demonstration cluster which consists of three strings was deployed in April 2013 and successfully operated up to February 2014. We review the prototyping phase of the BAIKAL-GVD project and describe the configuration and design of the 2013 engineering array.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the mean excitation energy of liquid argon

The mean excitation energy (I-value) of liquid argon is a critical input for energy estimation in neutrino oscillation experiments. It is measured to be 199 +4 -5 eV using the range of 402.2 MeV protons from the Fermilab Linac. This compares to the author's recent evaluation of (197 ± 7) eV based on a combination of an oscillator strength distribution analysis, gaseous argon range measurements, sparse stopping power data on solid argon, and an extrapolation of data on the effect of phase from other substances. Using all sources of information, we recommend a value of (198 ± 4) eV for liquid argon, which is significantly higher than 188 eV, from ICRU-37's gaseous argon evaluation, commonly used in Monte Carlo codes such as Geant4.

47 OTHER INSTRUMENTATION↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Hard X-ray and radio emission at the onset of great solar flares

A study of the onset phase of ten great hard X-ray bursts is presented. It is shown from hard X-ray and radio observations in different wavelength ranges that the energization of the electrons proceeds on a global time-scale for some tens of seconds. In nine of the bursts, two phases of emission can be distinguished during the onset phase: the preflash phase (during which emission up to an energy limit ranging from some tens of keV to 200 keV is observed) followed ten to some tens of seconds later by the flash phase (where the count rate in all detector channels rises simultaneously to within some seconds). For two of the events, strong gamma-ray line emission is observed and is shown to start close to the onset of the flash phase.

Klein, K.-L.↗

The gravitational waves from the first-order phase transition with a dimension-six operator

We investigate in details the gravitational wave (GW) from the first-order phase transition (PT) in the extended standard model of particle physics with a dimension-six operator, which is capable of exhibiting the recently discovered slow first-order PT in addition to the usually studied fast first-order PT. To simplify the discussion, it is sufficient to work with an example of a toy model with the sextic term, and we propose an unified description for both slow and fast first-order PTs. We next study the full one-loop effective potential of the model with fixed/running renormalization-group (RG) scales. Compared to the prediction of GW energy density spectrum from the fixed RG scale, we find that the presence of running RG scale could amplify the peak amplitude by amount of one order of magnitude while shift the peak frequency to the lower frequency regime, and the promising regime of detection within the sensitivity ranges of various space-based GW detectors shrinks down to a lower cut-off value of the sextic term rather than the previous expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers

A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and offers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of \three has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillation and electroluminescence detection, and purity of the liquid argon from analyses of a collected sample of cosmic ray muons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double side read-out technique for mitigation of radiation damage effects in PbWO 4 crystals

Test beam results of a calorimetric module based on 3×3×22 cm 3 PbWO 4 crystals, identical to those used in the CMS ECAL Endcaps, read out by a pair of photodetectors coupled to the two opposite sides (front and rear) of each crystal are presented. Nine crystals with different level of induced absorption, from 0 to 20 m -1 , have been tested using electrons in the 50–200 GeV energy range. Photomultiplier tubes have been chosen as photodetectors to allow for a precise measurement of highly damaged crystals. The information provided by this double side read-out configuration allows to correct for event-by-event fluctuations of the longitudinal development of electromagnetic showers. By strongly mitigating the effect of non-uniform light collection efficiency induced by radiation damage, the double side read-out technique significantly improves the energy resolution with respect to a single side read-out configuration. The non-linearity of the response arising in damaged crystals is also corrected by a double side read-out configuration and the response linearity of irradiated crystals is restored. In high radiation environments at future colliders, as it will be the case for detectors operating during the High Luminosity phase of the Large Hadron Collider, defects can be created inside the scintillator volume leading to a non-uniform response of the calorimetric cell. As a result, the double side read-out technique presented in this study provides a valuable way to improve the performance of calorimeters based on scintillators whose active volumes are characterized by high aspect ratio cells similar to those used in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Organics in water contamination analyzer, phase 1

The requirements which would result in identifying the components of an automatic analytical system for the analysis of specific organic compounds in the space station potable water supply are defined. The gas chromatographic system for such an analysis is limited to commercially available off-the-shelf hardware and includes the sample inlet, an ionization detector, capillary columns as well as computerized compound identification. The sampling system will be a special variation of the purge and trap Tenax mode using six-port valves and a 500 microliter water sample. Capillary columns used for the separating of contaminants will be bonded phase fused silica with a silicone stationary phase. Two detectors can be used: photoionization and far ultraviolet, since they are sensitive and compatible with capillary columns. A computer system evaluation and program with the principle of compound identification based on the retention index is presented.

Source record↗

Study of silicon photomultiplier performance in external electric fields

In this paper, we report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149 K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No visible damage to the surface of the devices was caused by the exposure.

Noble liquid detectors (scintillation, ionization,↗

Interferometer mirror tilt correcting system

An interferometer is described, having several means for automatically adjusting the angular tilt of a reflecting surface in one of two paths to maintain the exit beams from the two paths parallel to each other. Three detectors at the output of the interferometer were disposed on mutually perpendicular axes which define a plane normal to the nominal exit beam axis. One detector at the origin of the axes was used as a reference for separate phase difference comparison with the outputs of the other two detectors on the X and Y axes to develop servo error signals.

Schindler, R. A.↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗