Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Analysis of Photogrammetry Data from ISIM Mockup

During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software, proprietary software owned by Geodetic Systems Inc. The primary objectives of the metrology performed on the ISIM mock-up were (1) to quantify the accuracy of the INCA3 photogrammetry camera on a representative full scale version of the ISIM structure at ambient temperature by comparing the measurements obtained with this camera to measurements using the Leica laser tracker system and (2), empirically determine the smallest increment of target position movement that can be resolved by the PG camera in the test setup, i.e., precision, or resolution. In addition, the geometrical details of the test setup defined during the mockup testing, such as target locations and camera positions, will contribute to the final design of the photogrammetry system to be used on the ISIM Flight Structure.

Nowak, Maria↗

Analysis of Photogrammetry Data from ISIM Mockup, June 1, 2007

During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software.

Nowak, Maria↗

NASA Tech Briefs, February 2012

This issue contains the following briefs: (1) Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration (2) Real-Time Flight Envelope Monitoring System (3) Nemesis Autonomous Test System (4) Mirror Metrology Using Nano-Probe Supports (5) Automated Lab-on-a-Chip Electrophoresis System (6) Techniques for Down-Sampling a Measured Surface Height Map for Model Validation (7) Multi-Component, Multi-Point Interferometric Rayleigh/Mie Doppler Velocimeter (8) Frequency to Voltage Converter Analog Front-End Prototype (9) Dust-Tolerant Intelligent Electrical Connection System (10) Gigabit Ethernet Asynchronous Clock Compensation FIFO (11) High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA (12) Glovebox for GeoLab Subsystem in HDU1-PEM (13) Modified Process Reduces Porosity when Soldering in Reduced Gravity Environments (14) Use of Functionalized Carbon Nanotubes for Covalent Attachment of Nanotubes to Silicon (15) Flexible Plug Repair for Shuttle Wing Leading Edge (16) Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes (17) Axel Robotic Platform for Crater and Extreme Terrain Exploration (18) Site Tamper and Material Plow Tool - STAMP (19) Magnetic Interface for Segmented Mirror Assembly (20) Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners (21) Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust (22) Aperture Ion Source (23) Virtual Ultrasound Guidance for Inexperienced Operators (24) Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time (25) Interactive Schematic Integration Within the Propellant System Modeling Environment (26) Magnetic and Electric Field Polarizations of Oblique Magnetospheric Chorus Waves (27) Variable Sampling Mapping.

Source record↗

Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a dispersive media, the effect of both phase and group indices have to be considered. Taking all these factors into account, a method was developed to measure targets through multiple regions of different materials and produce results that are absolute measurements of target position in three-dimensional space, rather than simply relative position. The environment in which the lidar measurements are taken must be broken down into separate regions of interest and each region solved for separately. In this case, there were three regions of interest: air, fused silica, and vacuum. The angular position of the target inside the chamber is solved using only phase index and phase velocity, while the ranging effects due to travel from air to glass to vacuum/air are solved with group index and group velocity. When all parameters are solved simultaneously, an absolute knowledge of the position of each target within an environmental chamber can be derived. Novel features of this innovation include measuring absolute position of targets through multiple dispersive and non-dispersive media, deconstruction of lidar raw data from a commercial off-the-shelf unit into reworkable parameters, and use of group velocities to reduce range data. Measurement of structures within a vacuum chamber or other harsh environment, such as a furnace, may now be measured as easily as if they were in an ambient laboratory. This analysis permits transformation of the raw data into absolute spatial units (e.g., mm). This technique has also been extended to laser tracker, theodolite, and cathetometer measurements through refractive media.

Kubalak, David↗

Mirror-centered representation of a focusing hyperbolic mirror for X-ray beamlines

Conic sections are commonly used in reflective X-ray optics. Hyperbolic mirrors can focus a converging light source and are frequently paired with elliptical or parabolic mirrors in Wolter type configurations. This paper derives the closed-form expression for a mirror-centered hyperbolic shape, with zero-slope at the origin. Combined with the slope and curvature, such an expression facilitates metrology, manufacturing and mirror-bending calculations. Previous works consider ellipses, parabolas, magnifying hyperbolas or employ lengthy approximations. Here, the exact shape function is given in terms of the mirror incidence angle and the source and image distances.

47 OTHER INSTRUMENTATION↗

Enhancing spectroscopy and microscopy with emerging methods in photon correlation and quantum illumination

Quantum optics has led to important advancements in our ability to prepare and detect correlations between individual photons. Its principles are increasingly translated into nanoscale characterization tools, furthering methods in spectroscopy, microscopy and metrology. Here, in this Review, we discuss the rapid progress in this field driven by advanced technologies of single-photon detectors and quantum-light sources, including time-resolved single-photon counting cameras, superconducting nanowire single-photon detectors and entangled photon sources of increasing brightness. We emphasize emerging applications in super-resolution microscopy, measurements below classical noise limits and photon-number-resolved spectroscopy—a powerful paradigm for the characterization of nanoscale electronic materials. We conclude by discussing key technological challenges and future opportunities in materials science and bionanophotonics alike.

Tsao, Chieh [University of California, Berkeley, C↗

Recent Developments in the Alignment and Test Plans for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The SIs and Guider are mounted to a composite metering structure with outer dimensions of 2.1 x 2.2 x 1.9m. The SI and Guider units are integrated to the ISIM structure and optically tested at NASA/Goddard Space Flight Center as an instrument suite using an OTE SIMulator (OSIM). OSIM is a high-fidelity, cryogenic JWST telescope simulator that features a approximately 1.5m diameter powered mirror. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. Temperature-induced mechanical SI alignment and structural changes are measured using a photogrammetric measurement system at ambient and cryogenic temperatures. OSIM is aligned to the ISIM mechanical coordinate system at the cryogenic operating temperature via internal mechanisms and feedback from alignment sensors in six degrees of freedom. SI performance, including focus, pupil shear and wavefront error, is evaluated at the operating temperature using OSIM. We present an updated plan for the assembly and ambient and cryogenic optical alignment, test and verification of the ISIM element.

Ohl, Raymond↗

Diaboloidal mirrors: algebraic solution and surface shape approximations

A new type of optical element that can focus a cylindrical wave to a point focus (or vice versa) is analytically described. Such waves are, for example, produced in a beamline where light is collimated in one direction and then doubly focused by a single optic. A classical example in X-ray optics is the collimated two-crystal monochromator, with toroidal mirror refocusing. The element here replaces the toroid, and in such a system provides completely aberration free, point-to-point imaging of rays from the on-axis source point. We present an analytic solution for the mirror shape in its laboratory coordinate system with zero slope at the centre, and approximate solutions, based on bending an oblique circular cone and a bent right circular cylinder, that may facilitate fabrication and metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication, Metrology and Modeling of the Space-Based Lidar Telescope for SPARCLE

Over the past 7 years, NASA Marshall Space Flight Center (MSFC) through the Global Hydrology and Climate Center (GHCC) has been working; in collaboration with the University of Alabama in Huntsville (UAH) Center for Applied Optics (CAO), and others; towards demonstrating a solid state coherent Doppler lidar instrument for space-based global measurement of atmospheric winds. The Space Readiness Coherent Lidar Experiment (SPARCLE) was selected by NASA's New Millennium Program to demonstrate the feasibility and technology readiness of space-based coherent wind lidar. The CAO was responsible for the design, development, integration, and testing of the SPARCLE optical system. Operating at 2-micron wavelength, SPARCLE system performance is dominated by the optical quality of the transmitter/receiver optical system. The stringent optical performance requirements coupled with the demanding physical and environmental constraints of a space-based instrument necessitate extensive characterization of the telescope optical performance that is critical to predicting the lidar system efficiency and operation in space. Individual components have been measured prior to assembly and compared to the designed specifications. Based on the individual components, the telescope design was optimized to produce a suitable telescope. Once the telescope is completed, it will be tested and evaluated and the data shall be used to anchor computer based models of the optical system. Commercial optical modeling codes were used to evaluate the performance of the telescope under a variety of anticipated on-orbit environments and will eventually be compared to environmental tests conducted in the course of qualifying the telescope for flight. Detailed analysis using the "as built" data will help to reduce uncertainties within the lidar system model and will increase the accuracy of the lidar performance predictions.

Peters, Bruce R.↗

Exosuit Prototypic Knee: EPK

Resistive/aerobic exercises are invaluable countermeasures to musculoskeletal/sensorimotor/cognitive deconditioning resulting from spaceflight (i.e., microgravity). In preparation for human exploration to the moon and beyond, exercise countermeasures face new mass/volume constraints, rendering current on-orbit systems infeasible. Further, effective exercise systems are critical for maintaining crew performance/health levels necessary for Lunar extravehicular activities (EVAs) and transit. Exosuits are the pinnacle of wearable and adaptable technology set to provide a lightweight, compact, innovative solution to exploration-constrained exercise. However, reliable wearable kinematic sensors integrated with softgoods have not been demonstrated in (operational) spaceflight applications. To address this gap, the project team developed a prototype exosuit knee-joint, replete with relevant sensors for determination of joint angles, and corresponding laboratory testing bench to validate the exosuit sensing performance. This technology advancement is a pre-cursor to a more expansive multi-purpose exosuit concept that provides metrology, exercise, rehabilitation, and/or augmentation.

Fiber optics↗

Lightweight and High Angular Resolution X-Ray Optics

The International X-ray Observatory (IXO) mission requires a lightweight and high throughput spectroscopic telescope. The fabrication, alignment, and integration of this mirror assembly require breakthroughs in many areas. In this paper we report on our recent progress in all these areas, including mirror fabrication, coating, metrology, alignment, mechanical characteristics, and their integration into mirror modules. In particular, we will also outline our plan for the next few of years, showing approaches that will progress toward reaching the 5' HPD requirement.

Zhang, William↗

Lightweight and High Angular Resolution X-Ray Optics

The International X-ray Observatory (IXO) mission requires a lightweight and high throughput spectroscopic telescope. The fabrication, alignment, and integration of this mirror assembly require breakthroughs in many areas. In this paper we report on our recent progress in all these areas, including mirror fabrication, coating, metrology, alignment, mechanical characteristics, and their integration into mirror modules. In particular, we will also outline our plan for the next few of years, showing approaches that will progress toward reaching the 5" HPD requirement.

Zhang, William W.↗

Frequency reproducibility of solid-state thorium-229 nuclear clocks

Solid-state thorium-229 ( 229 Th) nuclear clocks are set to provide new opportunities for precision metrology and fundamental physics. Taking advantage of inherent low sensitivity of a nuclear transition to its environment, orders of magnitude more emitters can be hosted in a solid-state crystal compared with current optical lattice atomic clocks. Furthermore, solid-state systems needing only simple thermal control are key to the development of field-deployable compact clocks. Here we explore and characterize the frequency reproducibility of the 229 Th:CaF 2 nuclear clock transition, a key performance metric for all clocks. We measure the transition linewidth and centre frequency as a function of the doping concentration, temperature and time. We report the concentration-dependent inhomogeneous linewidth of the nuclear transition, limited by the intrinsic host crystal properties. We determine an optimal working temperature for the 229 Th:CaF 2 nuclear clock at 196(5) K, at which the first-order thermal sensitivity vanishes. This would enable in situ temperature co-sensing using different quadrupole-split lines, reducing the temperature-induced systematic shift below the 10 −18 fractional frequency uncertainty level. At 195 K, the reproducibility of the nuclear transition frequency is 220 Hz (fractionally 1.1 × 10 −13 ) for two differently doped 229 Th:CaF 2 crystals over 7 months. Furthermore, these results form the foundation for understanding, controlling and harnessing the coherent nuclear excitation of 229 Th in solid-state hosts and for their applications in constraining temporal variations of fundamental constants.

Atomic and molecular physics↗

Establishing temperature from radiance of dynamically compressed metals

Precise temperature determination is a significant challenge in extreme environments of dynamic compression studies. How can radiance measurements taken in high-pressure shock experiments constrain temperature in a meaningful and physically consistent way? Experiments maintaining sample compression against a transparent window can be tailored to present a uniform measurement area with uncertain spectral emissivity. We compare several methods to analyze radiance collected at multiple wavelengths, applying statistical methods and physical principles to improve temperature inference. With proper radiance collection and analysis, dynamic temperature uncertainties become comparable to thermomechanical ambiguities of the emitting surface.

36 MATERIALS SCIENCE↗

Ultra-precision processes for optics manufacturing

The Optics MODIL (Manufacturing Operations Development and Integration Laboratory) is developing advanced manufacturing technologies for fabrication of ultra precision optical components, aiming for a ten-fold improvement in precision and a shortening of the scheduled lead time. Current work focuses on diamond single point turning, ductile grinding, ion milling, and in/on process metrology.

Martin, William R.↗

Cryogenic Thermal Distortion Model Validation for the JWST ISIM Structure

The James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Structure is a precision optical metering structure for the JWST science instruments. Optomechanical performance requirements place stringent limits on the allowable thermal distortion of the metering structure. A significant effort was completed to develop capabilities to predict and metrologize cryogenic thermal distortion of the ISIM Structure. This paper focuses on thermal distortion finite element modeling, analysis, and model validation. Extensive thermal distortion analysis was completed during the design phase for the ISIM Structure to demonstrate that thermal distortion requirements were achieved. Comparison of measurements from recently completed cryogenic testing and model predictions demonstrate the adequacy of thermal distortion modeling uncertainty factors adopted during the design phase, and provide bounds on the accuracy of the model predictions. This paper will provide an overview of the test configurations, describe the thermal distortion models of the tests, and provide a comparison of test results and analytical predictions from the models.

Johnston, John D.↗