Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Spectral Effects on the Energy Harvesting Efficiency of Two- and Four-Terminal Tandem Photovoltaics

In this work, the effect of a varying spectral irradiance and top cell bandgap on the energy harvesting efficiency of two-terminal (2T) and four-terminal (4T) perovskite//silicon tandem solar cells under outdoor operating conditions is investigated. For the comparison, an optoelectronic model employing a 1 year outdoor data set for a 4T mechanical stacked gallium arsenide (GaAs) on crystalline silicon (Si) tandem device is first validated. Then, the verified model is used to simulate perovskite//silicon tandem devices with a varying perovskite top cell bandgap for a location in Golden, Colorado, USA. Here, a spectral binning method to efficiently reduce and improve the visualization of the 1 min-resolved environmental data while maintaining the simulation accuracy is introduced. The findings reveal that, for a device that is current matched under standard testing conditions, the annual spectral deviation reduces the energy harvesting efficiency by only 2% rel . When additional realistic losses for the 4T are taken into account, 2T devices are shown to have an energy-harvesting efficiency that is at parity or higher. Deviations in the top cell bandgap are more than 0.1 eV from current matching result in a reduced energy harvesting efficiency of more than 5% rel for the 2T tandem device.

14 SOLAR ENERGY↗

Climate-simulated raceway pond culturing: quantifying the maximum achievable annual biomass productivity of Chlorella sorokiniana in the contiguous USA

Chlorella sorokiniana (DOE 1412) emerged as one of the most promising microalgae strains from the NAABB consortium project, with a remarkable doubling time under optimal conditions of 2.57 hr-1. However, its maximum achievable annual biomass productivity in outdoor ponds in the contiguous United States remained unknown. In order to address this knowledge gap, this alga was cultured in indoor LED-lighted and temperature-controlled raceways in nutrient replete freshwater (BG-11) medium at pH 7 under conditions simulating the daily sunlight intensity and water temperature fluctuations during three seasons in Southern Florida, an optimal outdoor pond culture location for this organism identified by biomass growth modeling. Prior strain characterization indicated that the average maximum specific growth rate (µmax) at 36 ºC declined continuously with pH, with µmax corresponding to 5.92, 5.83, 4.89, and 4.21 day-1 at pH 6, 7, 8, and 9, respectively. In addition, the maximum specific growth rate declined nearly linearly with increasing salinity until no growth was observed above 35 g/L NaCl. In the climate-simulated culturing studies, the volumetric ash-free dry weight-based biomass productivities during the linear growth phase were 57, 69, and 97 mg/L-day for 30-year average light and temperature simulations for January (winter), March (spring), and July (summer), respectively, which corresponds to average areal productivities of 11.6, 14.1, and 19.9 g/m2-day at a constant pond depth of 20.5 cm. The photosynthetic efficiencies (PAR) in the three climate-simulated pond culturing experiments ranged from 4.1 to 5.1%. The annual biomass productivity was estimated as ca. 15 g/m2-day, nearly double the U.S. Department of Energy (DOE) 2015 State of Technology annual cultivation productivity of 8.5 g/m2-day, but this is still significantly below the projected 2022 target of ca. 25 g/m2-day (U.S. DOE, 2016) for economic microalgal biofuel production, indicating the need for additional research in strain biology and system engineering.

annual biomass productivity↗

Research needs targeting direct air capture of carbon dioxide: Material & process performance characteristics under realistic environmental conditions

The extraction of CO 2 from ambient air, or direct air capture (DAC), is a crucial negative CO 2 emissions technology with great potential for contributing to the mitigation of global warming and climate change. Furthermore, nearly all published research on DAC has been conducted under indoor temperature conditions, i.e. 20 to 30 °C. In contrast, the future global implementation of DAC requires it to be operational across a wide expanse of geographical areas, of which the local temperatures can vary between -30 to 50 °C. Similarly, the absolute humidity can vary from ~0 to 84 g/m 3 in various locations. Due to the massive amount of air that would be processed, it may be impractical to preheat or dehumidify the air before the CO 2 separation. Therefore, it is important to develop DAC materials with good performance at realistic outdoor conditions, especially at sub-ambient conditions, i.e. -30 to 20 °C. In addition to material development, system-level studies at sub-ambient conditions are also needed for the DAC processes to reach optimal designs, which may be very different from those at ambient conditions. In this perspective article, we first assess the literature to identify the technical gaps that need to be filled for DAC to be applicable at realistic outdoor conditions. We then suggest additional research directions needed for DAC to be viable under varied conditions from the perspectives of materials and system designs. For materials, we discuss the expected physical and chemical property changes for the sorbents when the temperature or humidity reaches extremes within their range, and how that will impact performance. Similarly, for system design, we indicate how varied conditions will impact performance and how these changes will impact process optimization.

20 FOSSIL-FUELED POWER PLANTS↗

Cost minimization of deoxygenation for control of Vampirovibrio chlorellavorus in Chlorella sorokiniana cultures

Deoxygenation is a strategy for preventing Vampirovibrio chlorellavorus infection of Chlorella sorokiniana cultures. Deoxygenation cost was minimized by sparging with nitrogen gas for only one hour at the onset of night and relying on naturally-occurring dark-respiration to maintain low oxygen concentrations throughout the night. This technique substantially reduced V. chlorellavorus infection in laboratory co-cultures. The cost of the approach was evaluated in outdoor experiments with one pure water and one pathogen-free C. sorokiniana culture, grown in a 150-L sealed, vented, translucent-polyethylene reactor. Unlike the small laboratory reactors, which were also sealed and vented, the much larger outdoor reactor maintained the dissolved oxygen concentration in the C. sorokiniana culture at near zero concentration throughout the night cycle. This demonstrates that large covered tanks in commercial applications would keep oxygen concentration near zero for the entire night. The total nitrogen sparged, per night, per liter of algal culture, was determined for the 150-L reactor, and used to estimate the cost per m2 for large scale raceways. Onsite nitrogen generators are the most cost-effective method to supply a high flow of nitrogen gas to commercial scale raceways. The cost of deoxygenation treatment ranged from $16/ton AFDW algae for a shallow (2 cm) gravity flow system with 75% harvest prior to deoxygenation to over $1,300/ton for a 20 cm depth raceway with plastic tanks.

59 BASIC BIOLOGICAL SCIENCES↗

Reliability metrics and their management implications for open pond algae cultivation

The prevalence of contaminating organisms in outdoor algae cultivation, with the often-associated dramatic crop failures, necessitates the need for metrics describing production system reliability. Standard metrics for algae cultivation reliability are critically needed to be able to map improvements in operational parameters, but do not currently exist. In this work, we present a set of standard metrics including mean time to failure (MTTF) and mean time between failures (MTBF) as the basis for the calculation of pond failure rate (FR) and reliability coefficient (RC). Metrics associated with the numbers of contaminating organisms such as abundance ratio (AR), prevalence of infection (PI), and mean intensity of infection (MII) are also relevant. These metrics, based on measured experimental values of outdoor pond performance during the Algae Testbed Public-Private Partnership (ATP3) Unified Field Studies (UFS), provide a basis for quantifying pond failure and provide insight into potential pond management and contaminant mitigation strategies. From these reliability metrics applied to this dataset, we are able to link operational parameters, such as harvest frequency and inoculum source, to pond reliability for different algae strains and seasons, and from an assessment of AR, provide contamination thresholds beyond which a culture may be unrecoverable. Ultimately, the implementation of widely-practiced and simple-to-calculate algae pond reliability metrics calculated from rapid and easy to collect data or observations will reduce risk and uncertainty in large-scale algae deployment and aid in the development of integrated pest management (IPM) strategies.

09 BIOMASS FUELS↗

Janthinobacter additions reduce rotifer grazing of microalga Microchloropsis salina in biotically complex communities

Grazing and parasitism in algal production systems are significant causes of crop loss. Biological control of algal ponds, such as application of protective bacteria, represents a promising alternative to current mitigation strategies. The major barriers to probiotic methods are the lack of identified protective bacteria and uncertainty of scale-up effects, including potential negative interactions with the resident algal microbiome. Here, we report that application of Janthinobacter lividum affords robust protection against rotifer (Brachionus plicatilis) grazing on Microchloropsis salina. Protection was observed at laboratory scale from live bacteria and solvent extract additions as well as in biologically complex communities from bacterial additions to outdoor mesocosms. J. lividum persisted in outdoor communities for at least 3 days following addition, and did not lead to selective exclusion of specific taxa in the resident microbiome. These results demonstrate that J. lividum can provide protection against grazers in these diverse communities, without severe effects on the resident microbiome. Our results suggest that J. lividum is a promising treatment to mitigate algal crop losses due to pests. Additionally, the study highlights the importance of an ecologically-informed approach to algal crop management that will aid future applications in the biological control of algal ponds.

09 BIOMASS FUELS↗

Techno-economic and life-cycle assessment of fuel production from mixotrophic Galdieria sulphuraria microalgae on hydrolysate

Outdoor photoautotrophic algal growth is limited by light attenuation and attendant respiratory CO 2 losses during dark periods, limiting its productivity potential and carbon use efficiency. Developing a system that leverages mixotrophic growth (combining the benefits of both heterotrophic and photoautotrophic growth) has the potential to dramatically improve the total productivity and economics of the system. However, it is unknown if the productivity gains offset the added costs of outdoor mixotrophic cultivation using cellulosic hydrolysate as the feedstock. In this study, corn stover-derived cellulosic sugars were evaluated as the mixotrophic organic carbon source for the cultivation of Galdieria sulphuraria, which can metabolize both glucose and xylose from corn stover hydrolysate. A techno-economic analysis (TEA) and a life-cycle assessment (LCA) were conducted based on a detailed engineering process model for both glass helical photobioreactor and covered pond cultivation platforms, coupled with downstream conversion and upgrading to renewable diesel through hydrothermal liquefaction. Results show the minimum biomass selling price for cultivation in the photobioreactor design assuming a productivity of 1.575 kg m -3 day -1 and a substrate yield of 0.57 g g -1 is $2869 per dry metric ton. The costs are dramatically reduced in the covered pond design which assumes a productivity of 0.8 kg m -3 day -1 and a substrate yield of 0.7 g g -1 , 921 dollars per dry metric ton. Expanding the system boundary to include downstream processing results in a minimum fuel selling price of 8.24 dollars and 3.32 dollars dm 3 GE -1 for the photobioreactor and covered pond systems, respectively. Finally, life-cycle results demonstrate a global warming potential of 339 and 9.1 gCO 2 -eq. MJ -1 on a well-to-wheels basis and a net energy ratio of 2.21 and 0.25 MJ MJ -1 for the photobioreactor and covered pond systems, respectively. Discussion focuses on a required co-product selling price as a function of biomass diversion to meet economic parity with conventional fuels.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a field-deployable qPCR assay for real-time pest monitoring in algal cultivation systems

Outdoor cultivation is commonly used to produce algal biomass for a variety of bioproducts including food, feed, fuel, pharmaceuticals, and nutraceuticals. Outdoor cultivation ponds are highly susceptible to pest pressures that may lead to periods of low productivity or even entire loss of the algal crop. Consequently, there is a need for rapid, real-time tracking of pests for early intervention to mitigate crop loss. In this work, we describe the development of a field deployable, low-cost qPCR assay for detecting both known and novel pests of a farmed eukaryotic alga species, Nannochloropsis sp. We performed a proximity guided metagenome deconvolution approach (ProxiMeta™) to discover novel pests that temporally correspond to periods of reduced pond productivity. This approach provided high-quality metagenome assemblies that were used to design qPCR probes to detect specific pests of interest. The portable qPCR assay, designed to be deployed at remote field locations, enables low-cost surveillance with a rapid (2 h) turn-around time. Frequent sampling allows for early detection and prompts intervention strategies to remedy infected ponds to minimize crop loss. The qPCR assay was used to successfully detect a known predatory bacterium within the order Bdellovibrionales both in the lab and at a remote field location. Furthermore, we assembled the genome of two novel, site-specific pests in the Saprospiraceae family and successfully designed qPCR probes that differentially detected their presence in two different pond locations. Ultimately, this assay has the potential to monitor multiple pests simultaneously and tailor targets to match likely pest infections that differ across geographical locations, helping to mitigate crop loss on a large scale.

59 BASIC BIOLOGICAL SCIENCES↗

Optimized Illuminance Operation-A Light-Driven Dilution Strategy to Improve Microalgae Biomass Productivity

Periodic dilution is a necessary operation to avoid light limitation due to self-shading as the culture grows dense. However, environmental conditions are constantly changing in outdoor cultivation systems, making it difficult to determine the optimal dilution rate. To address this challenge, this study evaluated a dilution approach based on light penetration to optimize illuminance (OptiLum) in the culture. Biomass concentration was controlled via sensor-feedback directed dilution to ensure that light reaching the bottom of the culture was maintained above the compensation intensity. Under replicated outdoor pond conditions, by keeping the entire culture within a net-positive photosynthetic zone, the OptiLum operation improved the biomass productivities of two top-performing strains, Picochlorum celeri and Tetraselmis striata, by 95 % and 86 %, respectively, compared to conventional semi-continuous batch cultivation. The dilution rate varied daily and was dynamically adjusted based on the light status within the culture, which is concurrently influenced by weather, culture density, and growth rate. The techno-economic analysis showed that the OptiLum operation could reduce biomass production cost by as much as 24 % and 33 % for P. celeri and T. striata, respectively, assuming a low-cost dewatering approach with initial gravity settling of biomass can be realized for both strains. However, a more costly two-stage dewatering strategy, comprising only membranes and centrifuges, may be necessary for non-settling strains, such as P. celeri, which would alternatively increase production costs by 23 % for the OptiLum case. The results demonstrated that the proposed OptiLum operation is a promising approach to improve biomass productivity and lower production cost via weather-responsive and self-adjusting dilution.

09 BIOMASS FUELS↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Performance of low-cost indoor air quality monitors for PM 2.5 and PM 10 from residential sources

Advances in particle sensor design and manufacturing have enabled the development of low-cost air quality monitors (LCMs). Here, the sensors use light scattering to estimate mass concentration and thus require evaluation for aerosols of varied composition and size distribution. We tested the performance of six LCMs designed for home use and having a retail price under US$300 in October 2018. We assessed their performance by comparing their output to reference PM 2.5 and PM 10 measurements from 21 common residential sources and from infiltrated outdoor PM 2.5 . Reference data were obtained by using gravimetric measurements to adjust time-resolved output from an aerosol spectrometer with both electrical mobility and optical particle sensors. Compared by linear regression to reference measurements, LCMs had negative intercepts and slopes of 1–2 for infiltrated outdoor PM 2.5 . Semi-quantitative responses (~50–200% of actual PM 2.5 ) were obtained for varied aerosols including minerals (ultrasonic humidifier, vacuuming, test dust); combustion products (incense, mosquito coil, extinguished candles); microwave popcorn; and cooking involving frying or grilling. LCMs had low or no response to sources for which all mass was in particles smaller than 0.25 μm, including steady candle flames and cooking without frying or grilling. PM 10 data from LCMs was more variable than PM 2.5 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings

Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗