Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Note: Multi-pass Thomson scattering measurement on the TST-2 spherical tokamak

In multi-pass Thomson scattering (TS) scheme, a laser pulse makes multiple round trips through the plasma, and the effective laser energy is enhanced, and we can increase the signal-to-noise ratio as a result. We have developed a coaxial optical cavity in which a laser pulse is confined, and we performed TS measurements using the coaxial cavity in tokamak plasmas for the first time. In the optical cavity, the laser energy attenuation was approximately 30% in each round trip, and we achieved a photon number gain of about 3 compared with that obtained in the first round trip. In addition, the temperature measurement accuracy was improved by accumulating the first three round trip waveforms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Proton irradiation at kilowatt-power and neutron production from a free-surface liquid-lithium target

The free-surface Liquid-Lithium Target, recently developed at Soreq Applied Research Accelerator Facility (SARAF), was successfully used with a 1.9 MeV, 1.2 mA (2.3 kW) continuous-wave proton beam. Neutrons (∼2 × 10{sup 10} n/s having a peak energy of ∼27 keV) from the {sup 7}Li(p,n){sup 7}Be reaction were detected with a fission-chamber detector and by gold activation targets positioned in the forward direction. The setup is being used for nuclear astrophysics experiments to study neutron-induced reactions at stellar energies and to demonstrate the feasibility of accelerator-based boron neutron capture therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A rigid piezo motor with large output force and an effective method to reduce sliding friction force

We present a completely practical TunaDrive piezo motor. It consists of a central piezo stack sandwiched by two arm piezo stacks and two leg piezo stacks, respectively, which is then sandwiched and spring-clamped by a pair of parallel polished sapphire rods. It works by alternatively fast expanding and contracting the arm/leg stacks while slowly expanding/contracting the central stack simultaneously. The key point is that sufficiently fast expanding and contracting a limb stack can make its two sliding friction forces well cancel, resulting in the total sliding friction force is <10% of the total static friction force, which can help increase output force greatly. The piezo motor's high compactness, precision, and output force make it perfect in building a high-quality harsh-condition (vibration resistant) atomic resolution scanning probe microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Fast imaging of DNA in atomic force microscopy enabled by a local raster scan algorithm

Approaches to high-speed atomic force microscopy typically involve some combination of novel mechanical design to increase the physical bandwidth and advanced controllers to take maximum advantage of the physical capabilities. For certain classes of samples, however, imaging time can be reduced on standard instruments by reducing the amount of measurement that is performed to image the sample. One such technique is the local raster scan algorithm, developed for imaging of string-like samples. Here we provide experimental results on the use of this technique to image DNA samples, demonstrating the efficacy of the scheme and illustrating the order-of-magnitude improvement in imaging time that it provides.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: High-efficiency broadband acoustic energy harvesting using Helmholtz resonator and dual piezoelectric cantilever beams

A high-efficiency broadband acoustic energy harvester consisting of a compliant-top-plate Helmholtz resonator (HR) and dual piezoelectric cantilever beams is proposed. Due to the high mechanical quality factor of beams and the strong multimode coupling of HR cavity, top plate and beams, the high efficiency in a broad bandwidth is obtained. Experiment exhibits that the proposed harvester at 170–206 Hz has 28–188 times higher efficiency than the conventional harvester using a HR with a piezoelectric composite diaphragm. For input acoustic pressure of 2.0 Pa, the proposed harvester exhibits 0.137–1.43 mW output power corresponding to 0.035–0.36 μW cm{sup −3} volume power density at 170–206 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Simulation and test of a strip source electron gun

We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm{sup 2}, respectively, that corresponds to power density of 11.5 kW/cm{sup 2}, at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive. Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Design and initial results of a multi-pulsed intense electron beam source

A multi-pulsed intense electron beam source is introduced, including the design and the initial experimental results. The source can generate a burst of three pulses of intense electron beams with energy of 2–3 MeV and beam intensities of around 2.5 kA. An inductive adder is chosen to generate the pulsed diode voltages and a dispenser cathode is chosen to emit electron beams. The test results indicate that the design of the source is reliable. The multi-pulsed diode voltage is up to 2.5 MV and the beam intensities are more than 2 kA at the exit of the source with small variation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A note on the Landauer principle in quantum statistical mechanics

The Landauer principle asserts that the energy cost of erasure of one bit of information by the action of a thermal reservoir in equilibrium at temperature T is never less than k B T log 2. We discuss Landauer's principle for quantum statistical models describing a finite level quantum system S coupled to an infinitely extended thermal reservoir R. Using Araki's perturbation theory of KMS states and the Avron-Elgart adiabatic theorem we prove, under a natural ergodicity assumption on the joint system S+R, that Landauer's bound saturates for adiabatically switched interactions. The recent work [Reeb, D. and Wolf M. M., “(Im-)proving Landauer's principle,” preprint http://arxiv.org/abs/arXiv:1306.4352v2 (2013)] on the subject is discussed and compared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: On-line weak signal detection via adaptive stochastic resonance

We design an instrument with a novel embedded adaptive stochastic resonance (SR) algorithm that consists of a SR module and a digital zero crossing detection module for on-line weak signal detection in digital signal processing applications. The two modules are responsible for noise filtering and adaptive parameter configuration, respectively. The on-line weak signal detection can be stably achieved in seconds. The prototype instrument exhibits an advance of 20 dB averaged signal-to-noise ratio and 5 times averaged adjust R-square as compared to the input noisy signal, in considering different driving frequencies and noise levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Numerical simulation and experimental validation of accelerating voltage formation for a pulsed electron accelerator

This paper describes the development of a computation model of a pulsed voltage generator for a repetitive electron accelerator. The model is based on a principle circuit of the generator, supplemented with the parasitics elements of the construction. Verification of the principle model was achieved by comparison of simulation with experimental results, where reasonable agreement was demonstrated for a wide range of generator load resistance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Dynamic strain field mapping with synchrotron X-ray digital image correlation

We present a dynamic strain field mapping method based on synchrotron X-ray digital image correlation (XDIC). Synchrotron X-ray sources are advantageous for imaging with exceptional spatial and temporal resolutions, and X-ray speckles can be produced either from surface roughness or internal inhomogeneities. Combining speckled X-ray imaging with DIC allows one to map strain fields with high resolutions. Based on experiments on void growth in Al and deformation of a granular material during Kolsky bar/gas gun loading at the Advanced Photon Source beamline 32ID, we demonstrate the feasibility of dynamic XDIC. XDIC is particularly useful for dynamic, in-volume, measurements on opaque materials under high strain-rate, large, deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗