Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “New Mexico”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Verification Testing of OLI Systems Mixed Solvent Electrolyte Model for the Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 ) System to High Ionic Strength at 25°C

This technical report summarizes model verification results and summary statistics for 41 evaporite mineral solubility cases evaluated by Savannah River National Laboratory using OLI Systems’ aqueous electrolyte thermodynamic modeling software. The 41 verification cases containing a total of 60 solubility curves comprise mineral solubility data from low to high ionic strength at 25°C for the eight-component system Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 O as reported by Harvie et al. (1984). Thermodynamic calculations were executed using OLI Systems’ Stream Analyzer computation module within the OLI Studio software platform (Ver. 11.0, Rev. 11.0.1.9). The Mixed Solvent Electrolyte (MSE) thermodynamic framework was chosen for this investigation because of its superiority in modeling high ionic-strength inorganic salt solutions and actinide redox chemistry and solubility, both of which are relevant to the geological repository conditions at the Waste Isolation Pilot Plant in Carlsbad, New Mexico. Mineral solubility data in various inorganic salt solutions were digitized and extracted from figures generated by Harvie et al. (1984). For each of the 60 solubility curves, a case-specific chemistry model and input file were generated in OLI Studio using OLI Stream Analyzer and the MSE (H 3 O + ion) public databank provided by OLI Systems. Model simulation results were exported to Microsoft Excel to calculate summary statistics and to generate graphs comparing the OLI model predictions to the solubility data. Summary statistics include residuals (model – data) and concordance (accuracy × precision, where precision is indicated by the Pearson correlation coefficient and accuracy accounts for bias and scale differential). Private databanks were not developed, and activity coefficient model regressions were not performed to improve OLI model fits to the data. Of the 41 model verification plots, 83% have a mean of the percent residuals less than or equal to 25%. Similarly, 75% display a concordance greater than or equal to 0.75. Only seven of the 41 verification plots fail to show good agreement between the model and data. Of these seven, three are relevant to the WIPP repository because they involve the Mg-OH-Cl-SO 4 -CO 3 aqueous system. The remaining four address salt solubilities at the pH extremes (strong acid and strong base). It should be noted that in two of the three Mg-OH-Cl-SO 4 -CO 3 system cases, the regressed Harvie et al. (1984) solubility curve also deviated from the data. Lack of agreement between the OLI model-predicted solubility curves and the data is attributable to one or more of the following: specific solid species are not included in the OLI MSE databank; there is significant variation among the different solubility datasets chosen by Harvie et al. (1984); the OLI MSE model’s thermodynamic parameters were determined using different solubility datasets; and the activity coefficient parameters for certain relevant ion-ion and ion-molecule pairs have not been optimized via data regression. Two recommendations for future work are to (1) evaluate solubility data for the Mg-OH-Cl-SO 4 -CO 3 system at high ionic strength and, if necessary, develop a private OLI MSE database that includes missing species and, where necessary, regressed standard state properties and interaction parameters; (2) perform similar verification testing of the OLI model for actinide solubility data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advances in 3D Geologic Modeling of Alluvial Basins with a Focus on Facies and Property Modeling

The unsaturated zone alluvium reference case is one of several geologic systems under consideration by the U.S. Department of Energy Office of Nuclear Energy for hosting repositories for spent nuclear fuel and associated waste (Sevougian et al., 2019). As noted by Mariner et al. (2018), the generic alluvial basin offers positive attributes that merit its consideration as a reference case by the Spent Fuel and Waste Science and Technology (SFWST) campaign. There are hundreds of alluvial basins and sub-basins scattered across the arid western United States (Figure 1-1). Precipitation and infiltration rates are relatively low with high evapotranspiration, resulting in vertical separation between repository and water table and thus longer transport paths to an aquifer. Accumulations of alluvial sediments within these basins are typically on the order of hundreds of meters, and locally may exceed 1,000 m in thickness, as is the case for the Deming sub-basin in southern New Mexico. A thick geologic host medium, which serves as the natural barrier system (NBS) in the conceptual model framework of a geologic disposal system, isolates the waste packages from receptors in the biosphere. Further, alluvial basin fill is typically comprised of stacked playa and lacustrine deposits along the basin axis (Perry et al., 2018). Characterized by low permeability, these layers protect the biosphere above the repository and the groundwater resources below the repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Incorporating Heterogeneity into 3D Geologic Models for the Alluvial Basin Reference Case

The unsaturated zone alluvium reference case is one of several geologic systems under consideration by the U.S. Department of Energy Office of Nuclear Energy for hosting repositories for spent nuclear fuel and associated waste (Sevougian et al., 2019). As noted by Mariner et al. (2018), the generic alluvial basin offers positive attributes that merit its consideration as a reference case by the Spent Fuel and Waste Science and Technology (SFWST) campaign. Hundreds of alluvial basins and sub-basins are scattered across the arid western United States (Figure 1-1). Precipitation and infiltration rates are relatively low with high evapotranspiration, resulting in deep regional water tables. Deep regional water tables allow for significant vertical separation between proposed repository depths and groundwater and thus longer transport paths from a hypothetical repository to an aquifer. Accumulations of alluvial sediments within these basins are typically on the order of hundreds of meters, and locally may exceed 1,000 m in thickness, as is the case for the Deming sub-basin in southern New Mexico. In alluvial basins, alluvium creates a thick geologic host medium that serves as the natural barrier system (NBS) in the conceptual model framework of a geologic disposal system and isolates the waste packages from receptors in the biosphere. Further, alluvial basin fill is typically comprised of stacked playa and lacustrine deposits along the basin axis (Perry et al., 2018). Characterized by low permeability, these layers protect the biosphere above the repository and the groundwater resources below the repository by limiting flow and transport of radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗

GeoThermalCloud: A Machine Learning Tool for Discovery, Exploration, and Development of Hidden Geothermal Resources

In this 25 minute presentation, we showcase our open source “GeoThermalCloud” tool for identifying hidden geothermal resources using a publicly available dataset for southwestern New Mexico. The presenters include Bulbul Ahmmed and Luke Frash. All of the visuals use source material from LA-UR approved publications and this work falls under the Earth Sciences DUSA. The code shown in this video is already released with LANL approval in open source format on GitHub and DockerHub. The audio in this video includes only material on the topics of geothermal energy and machine learning applied to geothermal energy. The primary machine learning method used is LANL’s Non-negative Matrix Factorization “NMFk” method. Modeling work also mentions LANL’s Geothermal Design Tool “GeoDT” which is another approved open source code that has been released by LANL. This work was performed for DOE Geothermal Technologies Office (DE-EE-3.1.8.1). The host for the released video is intended to be YouTube or a suitable perpetual data repository such as GDR.

15 GEOTHERMAL ENERGY↗

Workforce Development Programs [Slides]

As educational institutions of New Mexico, develop educational, training, and research programs in support of the pit manufacturing related STEM fields, which directly benefit LANL with critical hires.

99 GENERAL AND MISCELLANEOUS↗

2022 Climate Change Vulnerability Assessment and Resilience Plan Summary

Los Alamos National Laboratory (LANL, or the Laboratory) produced a Vulnerability Assessment and Resilience Plan (VARP) following Department of Energy (DOE) Guidance to assess and manage climate change related risks to the Laboratory’s assets and operations. This is a condensed summary of the Laboratory’s 2022 VARP – the full version of the document is not publicly available at this time. The VARP was led by the Pollution Prevention (P2) Program in the Environmental Protection and Compliance Division (EPC-DO) and covers the entirety of the 36-square-mile LANL site in Los Alamos, New Mexico. A Steering Committee, composed of representatives from the three main Laboratory Directorates and the Los Alamos Field Office, identified real property Critical Assets based on their Mission Dependency Index (MDI) scores. LANL used MDI scores of 70 and above, which are considered Mission-Critical, to generate a list of 141 Critical Asset facilities.

54 ENVIRONMENTAL SCIENCES↗

Global horizontal spectral irradiance and module spectral response measurements: an open dataset for PV research

This report describes the creation process and final content of a spectral irradiance dataset for Albuquerque, New Mexico accompanied by a set of spectral response measurements for modules deployed at the same location. The spectral irradiance measurements were made using horizontally mounted spectroradiometers; therefore, they represent global horizontal irradiance. The dataset combines non-continuous spectroradiometer and weather measurements from a two-year period into a single calendar year. The data files are accompanied by extensive metadata as well as example calculations and graphs to demonstrate the potential uses of this database. The spectral response measurements were carried out by the National Renewable Energy Laboratory using 12 commercial silicon modules types that are undergoing long-term evaluation at Sandia National Laboratories in Albuquerque.

14 SOLAR ENERGY↗

Impact of Lost Generation at the Glen Canyon Powerplant due to the Environmental Requirements for the Years 2024 to 2027

This report was prepared by Argonne National Laboratory (Argonne) and the National Renewable Energy Laboratory (NREL) in support of an economic and financial analysis conducted for the U.S. Department of Energy’s Western Area Power Administration (WAPA) of the loss in Glen Canyon power generation due to the environmental requirements for the years 2024 to 2027. WAPA markets electricity produced at hydroelectric facilities operated by the Bureau of Reclamation (Reclamation). The facilities known collectively as the Salt Lake City Area Integrated Projects (SLCA/IP) include dams equipped for power generation on the Colorado, Green, Gunnison, and Rio Grande rivers and on Plateau Creek in the states of Arizona, Colorado, New Mexico, Utah, and Wyoming.

13 HYDRO ENERGY↗

Source characterization of volatile organic compounds at Carlsbad Caverns National Park

Carlsbad Caverns National Park (CAVE), located in southeastern New Mexico, experiences elevated ground-level ozone (O 3 ) exceeding the National Ambient Air Quality Standard (NAAQS) of 70 ppbv. It is situated adjacent to the Permian Basin, one of the largest oil and gas (O&G) producing regions in the US. In 2019, the Carlsbad Caverns Air Quality Study (CarCavAQS) was conducted to examine impacts of different sources on ozone precursors, including nitrogen oxides (NO x ) and volatile organic compounds (VOCs). Here, we use positive matrix factorization (PMF) analysis of speciated VOCs to characterize VOC sources at CAVE during the study. Seven factors were identified. Three factors composed largely of alkanes and aromatics with different lifetimes were attributed to O&G development and production activities. VOCs in these factors were typical of those emitted by O&G operations. Associated residence time analyses (RTA) indicated their contributions increased in the park during periods of transport from the Permian Basin. These O&G factors were the largest contributor to VOC reactivity with hydroxyl radicals (62%). Two PMF factors were rich in photochemically generated secondary VOCs; one factor contained species with shorter atmospheric lifetimes and one with species with longer lifetimes. RTA of the secondary factors suggested impacts of O&G emissions from regions farther upwind, such as Eagle Ford Shale and Barnett Shale formations. The last two factors were attributed to alkenes likely emitted from vehicles or other combustion sources in the Permian Basin and regional background VOCs, respectively. Implications: Carlsbad Caverns National Park experiences ground-level ozone exceeding the National Ambient Air Quality Standard. Volatile organic compounds are critical precursors to ozone formation. Measurements in the Park identify oil and gas production and development activities as the major contributors to volatile organic compounds. Emissions from the adjacent Permian Basin contributed to increases in primary species that enhanced local ozone formation. Observations of photochemically generated compounds indicate that ozone was also transported from shale formations and basins farther upwind. Therefore, emission reductions of volatile organic compounds from oil and gas activities are important for mitigating elevated O 3 in the region.

54 ENVIRONMENTAL SCIENCES↗

Solid-State Mixed-Potential Electrochemical Sensors for Natural Gas Leak Detection and Quality Control (Final Technical Report)

Mitigation of methane emissions are a critical factor to limiting the impact of the natural gas industry on global climate change. Throughout the period of 2020-2024, the University of New Mexico and its commercialization partner and subcontractor, SensorComm Technologies, Inc. (SCT), have worked together to develop a low-cost Artificial Intelligence (AI)-driven Internet of Things (IoT)-based multi-gas sensor platform for methane emissions detection. In the final year of the project, we extended this work to include hydrogen detection in support of a transition to a hydrogen economy where hydrogen could be transported through existing natural gas infrastructure. Mixed potential electrochemical sensors were first prototyped by ceramic additive manufacturing and then transitioned to conventional ceramic manufacturing tape casting and screen-printing technologies in preparation for mass production. Demonstrated limits of detection of 5 ppm of methane in natural gas and 1 ppm of hydrogen were measured. These limits of detection are among the lowest of solid-state electrochemical sensors that have been reported in the literature or available in the industry. Machine learning algorithms were developed to identify natural gas mixtures with > 98% accuracy level and quantify methane concentrations at 97% accuracy. The presence of hydrogen could also be identified, and its concentration quantified at these accuracy levels. These algorithms were optimized for running on portable computing hardware which enabled > 1 Hz processing rates. A portable packaged IoT system was integrated with the electrochemical sensor in collaboration with SCT. The package consists of readout electronics with < 1 mV resolution, sensor temperature control, and data transmission over cellular wireless and/or Wi-Fi networks. Field testing was performed in two rounds at Colorado State University’s Methane Emissions Technology Evaluation Center (CSU METEC). The first round of testing demonstrated successful measurements of methane from an underground natural gas leak of 20 standard liters per minute (SLPM), which agreed with previously published literature using more sophisticated and expensive analytical equipment. The second round of testing showed that an above ground leak of 2 SLPM of hydrogen could be detected at 32 ft. This project has resulted in six published peer reviewed journal articles, over ten presentations at professional conferences, and one full patent application filed in 2023. Future work on this project includes increased sensitivity, higher production yields, and applications in the hydrogen safety and flare emissions monitoring spaces.

03 NATURAL GAS↗

Efficient green and yellow light-emitting diodes (LEDs) for solid-state lighting applications

In this project, Lumileds, the University of Michigan, the University of New Mexico, Sandia National Laboratories, and Ohio State University conducted a collaborative and comprehensive research effort to investigate the most promising approaches to improve green and yellow InGaN LEDs. Advanced LED characterization methods and predictive model calculations were applied to design optimization experiments more effectively and accelerate the pace of improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Notice of Submittal – 2023 Radionuclide Air Emissions Report for Los Alamos National Laboratory

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2023 and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s Rad NESHAP compliance program, which is part of the Environmental Protection and Compliance (EPC) Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Headquarters and EPA Region 6. The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL’s EDE was 0.43 for 2023. The annual limit is 10 millirem per year, established by the EPA in 40 CFR 61 Subpart H. All measured air emissions are modeled to a single location, known as the Maximally Exposed Individual (MEI). During calendar year 2023, LANL continuously monitored radionuclide emissions at 28 “major” release points, or stacks. The Laboratory estimates emissions from an additional 59 “minor” release points using radionuclide usage source terms in lieu of stack monitoring. Also, LANL uses an EPA approved network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates several meteorological monitoring towers. From these various systems, a comprehensive evaluation is conducted to calculate the MEI dose for the Laboratory. The MEI can be any member of the public at any off-site location where there is a residence, school, business, or office. In 2023, this MEI location was a business at 129 New Mexico State Road 4 (NM-4), located in the northern end of White Rock. The primary contributors to the off-site dose at this location are the ambient air data at that location combined with the collected potential emissions from unmonitored (minor) sources. Overall, the MEI dose in 2023 is similar to that which has been observed in recent years, and it remains well below the EPA’s 10 millirem per year limit. Doses reported to the EPA for the past 10 years are shown in Table E1.

54 ENVIRONMENTAL SCIENCES↗

Proceedings of the 13 th US/German Workshop on Salt Repository Research, Design, and Operation

This report summarizes the proceedings of the 13 th US/German Workshop on Salt Repository Research, Design, and Operation hosted by Sandia National Laboratories on June 20-23, 2023, in Santa Fe, New Mexico, USA. Over 60 participants attended, representing Germany, United States, the Netherlands, Australia, and the United Kingdom, along with the IAEA. The purpose of the US/German Workshop is to foster in-person collaboration and dialogue amongst salt repository researchers and nuclear waste disposal implementers across international organizations. The workshop included five sessions of topical presentations and two breakout sessions to promote additional discussion on compelling topics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The First Tri-Lab Workshop on Formal Verification: Capabilities, Challenges, Research Opportunities, and Exemplars

The First Tri-Lab Workshop on Formal Verification was held in Santa Fe, New Mexico, on December 5th, 2023. This workshop gathered staff from Sandia, Los Alamos, and Lawrence Livermore National Laboratories and NASA’s Jet Propulsion Laboratory. This report summarizes and expands on the presentations given and discussion had at this workshop. In this report, we describe the current capabilities and research needs related to formal methods at the NNSA labs. In particular, we identify medium-term and long-term research gaps in programming languages, formalization efforts of complex systems, embedded systems verification, hardware verification, cybersecurity, formal methods usability, workflows, numerical methods, the use of formal methods for artificial intelligence (and its converse, artificial intelligence for formal methods), and collaboration opportunities and considerations on these topics. We conclude with a small number of exemplar research problems related to these topics.

97 MATHEMATICS AND COMPUTING↗

Development of a colinear Second-Harmonic Orthogonal Polarization (SHOP) interferometer for electron areal density measurements in Magnetically Insulated Transmission Lines (MITLs)

Experimental measurements of low density plasmas forming in Magnetically Insulated Transmission Line (MITL) regions are desired to improve our understanding of current loss and power flow. Therefore, a new optical interferometer diagnostic was commissioned via this LDRD project. To measure the expected 10 13 - 10 17 cm -3 electron densities inside the 0.5 - 6 mm Anode-Cathode (A-K) gaps, a colinear SHOP interferometer diagnostic was constructed. The diagnostic was initially fielded on the University of New Mexico (UNM) Helicon-Cathode (HelCat) plasma device which provided a highly repeatable and well understood plasma source for which the colinear SHOP interferometer’s functionality could be verified and measured. Utilizing the highly repeatable plasma source and shot averaging, the interferometer was able to achieve an areal density sensitivity of 1×10 14 cm -2 . This work at UNM lead to a Review of Scientific Instruments (RSI) publication [20], DOI:10.1063/5.0101687. After the diagnostic’s capability was proven at UNM, the colinear SHOP interferometer was commissioned for use on the Sandia National Laboratories (SNL) Mykonos accelerator. Here, it provided the first temporal areal density measurements of plasma formation in a parallel plate MITL. The diagnostic was able to achieve a single shot (no multi-shot averaging like at UNM) areal density sensitivity of 1×10 15 cm -2 along a ~ 2mm probing path length, which provided adequate capability to conduct fundamental physics research of MITL plasma formation. CHICAGO and ALEGRA simulations support the diagnostics experimental findings. More experimental and computational work will continue, likely leading to another publication(s). The smaller scale Mykonos accelerator work has also provided justification that the colinear SHOP interferometer is a capable diagnostic for measuring plasma areal densities in the inner MITL and convolute regions of larger TW-class accelerators like SNL’s Z machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CI/CD Pipeline and DevSecOps Integration for Security and Load Testing

Dominic D’Onofrio is currently a Junior studying Information and Technology at New Mexico Institute of Mining and Technology. He recently secured an Internship with NMCCoE, where he is involved with the TracerFIRE 12 project. Additionally, he is contributing to the load and security testing team by researching ways to implement pipelining and DevSecOps; this is his main project while he is at part time capacity for TracerFIRE 12. He is doing these projects to enhance his knowledge as a system administrator and gain a deeper understating of cybersecurity practices within national labs.

97 MATHEMATICS AND COMPUTING↗

July 2023 Monthly Sewer Monitoring Report

The Sandia National Laboratories, in California (Sandia/CA) is a research and development facility, owned by the U.S. Department of Energy’s National Nuclear Security Administration agency (DOE/NNSA). The laboratory is located in the City of Livermore (the City) and is comprised of approximately 410 acres. The Sandia/CA facility is operated by National Technology and Engineering Solutions of Sandia, LLC (NTESS) under a contract with the DOE/NNSA. The DOE/ NNSA’s Sandia Field Office (SFO) oversees the operations of the site. North of the Sandia/CA facility is the Lawrence Livermore National Laboratory (LLNL), in which Sandia/CA’s sewer system combines with before discharging to the City’s Publicly Owned Treatment Works (POTW) for final treatment and processing. The City’s POTW authorizes the wastewater discharge from Sandia/CA via the assigned Wastewater Discharge Permit #1251 (the Permit), which is issued to the DOE/NNSA’s main office for Sandia National Laboratories, located in New Mexico (Sandia/NM). The Permit requires the submittal of this Monthly Sewer Monitoring Report to the City by the twenty-fifth day of each month.

99 GENERAL AND MISCELLANEOUS↗