Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Accurate Fe–He machine learning potential for studying He effects in BCC-Fe

Nanostructured Ferritic Alloys (NFAs) containing oxide nanoparticles are prospective advanced structural materials in future fusion reactors. Lacking fusion neutron sources with an adequate flux, modeling is critical to understand radiation damage in the NFAs, including helium effects. Machine learning interatomic potentials (MLPs) have been demonstrated to be capable of describing atomic interactions in chemically complex systems with comparable accuracy to density functional theory (DFT) but with much less computational costs. Hence, MLPs are chosen to study He bubble accumulation in chemically complex NFAs. As a preliminary step, we develop a Fe–He potential, based on ~10,000 atomic configurations. The developed MLP accurately predicts the bulk properties of BCC-Fe compared to DFT, including the lattice constant (2.832 Å), elastic constants (c 11 = 271 GPa, c 12 = 141, c 44 = 93), and phonon frequencies (maximum error < 3.5%). The MLP predicts He binding energies in He n V bubbles and He n clusters with a mean absolute error (MAE) of only ~70 meV, which is ~3 to ~5 times smaller than the MAE of binding energies estimated using empirical potentials. The MLP also accurately predicts the migration barrier of interstitial He (64 meV). Furthermore, the MLP correctly predicts the maximum number of He atoms (critical size) at which a He n V bubble (He n cluster) can kick-out a self-interstitial atom (SIA), forming a bigger He n V 2 bubble (He n V bubble). Subsequently, we use the MLP to perform molecular dynamics simulations to investigate the effect of temperature on the critical size of He n V bubbles and He n clusters. We find that the critical size decreases with increasing temperature — indicating that smaller bubbles and clusters can kick-out an SIA at higher temperatures, thereby escalating the He bubble growth. We report the current Fe–He MLP can be further developed to include all chemical interactions in NFAs.

36 MATERIALS SCIENCE↗

Advanced focusing system for secondary electrons in a bunch shape monitor

Non-destructive measurements of longitudinal beam profile in non-relativistic hadron accelerators are usually performed with Bunch Shape Monitors that utilize secondary electron emission to reproduce the shape of a primary ion beam. The existing devices, however, have poor electron collection efficiency from the wire and are limited to one dimensional measurements of the phase coordinate. Here, we present the development of a bunch shape monitor with improved performance for proton beams to be used in the Spallation Neutron Source accelerator. This improvement was achieved by adding focusing optics between the wire and the entrance slit, which will also allow measurements over a much higher dynamic range. Here we present the design, simulation and experimental test results of the developed new electron beam guidance system for the existing SNS bunch shape monitor that allowed significant improvement in the collection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements of pre-emptive identification of particle accelerator failures using binary classifiers and dimensionality reduction

In this paper we look at the properties of the Spallation Neutron Source (SNS) Differential Beam Current Monitor (DCM) data and various methods of data transformation to improve pre-emptive detection of machine trips. In this study, the foundation of the approach is the analysis of new underlying data and understanding various properties with the goal of faster classification, higher precision and higher recall with the aim to reduce false positives as low as required. The result of the research presented in this paper are a binary classifier capable of predicting accelerator failures with millisecond classification time, 96% precision, 58% true positive and 0% false positive rate and optimization techniques enabling real-time implementations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model calibration of the liquid mercury spallation target using evolutionary neural networks and sparse polynomial expansions

The mercury constitutive model predicting the strain and stress in the target vessel plays a central role in improving the lifetime prediction and future target designs of the mercury targets at the Spallation Neutron Source. We leverage the experiment strain data collected over multiple years to improve the mercury constitutive model through a combination of large scale simulations of the target behavior and the use of machine learning tools for parameter estimation. We present two interdisciplinary approaches for surrogate-based model calibration of expensive simulations using evolutionary neural networks and sparse polynomial expansions. The newly calibrated simulations achieve 7% average improvement on the prediction accuracy and 8% reduction in mean absolute error compared to previously reported reference parameters, with some individual sensors experiencing up to 30% improvement. The calibrated simulations can aid in fatigue analysis to estimate the mercury target lifetime, which reduces abrupt failure and saves tremendous amount of costs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Turbulence and transport in mirror geometries in the Large Plasma Device

Thanks to advances in plasma science and enabling technology, mirror machines are being reconsidered for fusion power plants and as possible fusion volumetric neutron sources. However, cross-field transport and turbulence in mirrors remains relatively understudied compared with toroidal devices. Turbulence and transport in mirror configurations were studied utilizing the flexible magnetic geometry of the Large Plasma Device (LAPD). Multiple mirror ratios from $M=1$ to $M=2.68$ and three mirror-cell lengths from $L=3.51$ to $L=10.86$ m were examined. Langmuir and magnetic probes were used to measure profiles of density, temperature, potential and magnetic field. The electric field-fluctuation-driven ${\tilde {\boldsymbol{E}}} \times {\boldsymbol{B}}$ particle flux, where $\boldsymbol{B}$ is the background field, was calculated from these quantities. Two probe correlation techniques were used to infer wavenumbers and two-dimensional structure. Cross-field particle flux and density fluctuation power decreased with increased mirror ratio. Core density and temperatures remain similar with mirror ratio, but radial line-integrated density increased. The physical expansion of the plasma in the mirror cell by using a higher field in the source region may have led to reduced density fluctuation power through the increased gradient scale length. This increased scale length reduced the growth rate and saturation level of rotational interchange and drift-like instabilities. Despite the introduction of magnetic curvature, no evidence of mirror-driven instabilities – interchange, velocity space or otherwise – were observed. For curvature-induced interchange, many possible stabilization mechanisms were present, suppressing the visibility of the instability.

Travis, Phil (ORCID:0000000343170432)↗

Templates of expected measurement uncertainties for total neutron cross-section observables

This paper provides a template of expected uncertainties and correlations for measurements of total neutron cross-section observables by transmission. Measurements with time-of-flight and mono-energetic neutron sources are covered. The information required for evaluations in the resonance region and high energy region is detailed, along with the template of uncertainties and correlations that can be used in the absence of other information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of areal density asymmetries on scattered neutron spectra in ICF implosions

Scattered neutron spectroscopy is a diagnostic technique commonly used to measure areal density in inertial confinement fusion experiments. Deleterious areal density asymmetries modify the shape of the scattered neutron spectrum. In this work, a novel analysis is developed, which can be used to fit the shape change. This will allow experimental scattered neutron spectroscopy to directly infer the amplitude and mode of the areal density asymmetries, with little sensitivity to confounding factors that affect other diagnostics for areal density. The model is tested on spectra produced by a neutron transport calculation with both isotropic and anisotropic primary fusion neutron sources. Multiple lines of sight are required to infer the areal density distribution over the whole sphere—we investigate the error propagation and optimal detector arrangement associated with the inference of mode 1 asymmetries.

Crilly, A. J. (ORCID:0000000204299332)↗

Fused x-ray and fast neutron CT reconstruction for imaging large and dense objects

Megavolt x-ray computed tomography (CT) is a powerful tool for three-dimensional characterization. However, its utility is limited for large objects composed of high-atomic number (Z) materials, where x rays fail to penetrate. Information from fast neutron CT (FNCT) can complement x-ray CT reconstructions since fast neutrons can more readily penetrate high-Z objects. In this work, we demonstrate a method for combining FNCT and x-ray CT data to create a single reconstruction, more accurate than could be achieved with either x rays or fast neutrons alone. The algorithm was tested on an exemplar comprising multiple concentric, nested cylinders of different materials. Simulated and empirical x-ray CT data were acquired for the exemplar using a 9 MV bremsstrahlung spectrum. Additional simulated and empirical FNCT data were acquired using an accelerator based fast neutron source. The FNCT data were used to synthesize x-ray CT data and augment the x-ray CT data missing due to lack of penetration. This approach mitigates artifacts that would otherwise negatively affect the accuracy and resolution of a single-modality reconstructed volume.

47 OTHER INSTRUMENTATION↗

Bayesian inference of anisotropic 2D small-angle scattering from sparse measurement

Here, we present a Bayesian inference framework for reconstructing anisotropic two-dimensional small-angle scattering (2D SAS) patterns from sparse, noisy, or partially missing data. The method combines a symmetry-aware angular basis with radial Gaussian process priors to enable accurate, training-free interpolation and denoising. Computational benchmarks demonstrate reliable recovery of both isotropic and high-order anisotropic features under severe data reduction. Experimental validations on stretched polymers, sheared wormlike micelles, and carbon fibers show improved fidelity and resolution compared to raw measurements, achieving comparable accuracy with up to 50-fold fewer detected neutrons. This approach enables quantitative structural analysis under low-flux, time-limited, or single-shot conditions, extending the applicability of 2D SAS techniques to compact neutron sources and mechanically driven soft matter systems undergoing transient structural changes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

An algebraic convolution formulation for multiple-scattering correction in small-angle neutron scattering

Multiple scattering in small-angle neutron scattering (SANS) redistributes spectral weight and distorts structural interpretation, particularly for thick or strongly scattering samples. We develop a finite-dimensional spectral desmearing framework that corrects multiple scattering without resorting to integral transforms or model-dependent extrapolation. The primary intensity is expanded in an orthonormal basis adapted to the isotropic transverse-momentum measure, under which convolution reduces to a recursive tensor contraction, allowing the Poisson-weighted multiple-scattering series to be evaluated directly in a finite-dimensional basis representation. This formulation yields a stable forward–inverse mapping between apparent and primary spectra. Numerical tests demonstrate convergence under repeated convolution and accurate recovery of the single-scattering intensity. Application to SANS measurements collected at multiple neutron facilities, including the Spallation Neutron Source, the High Flux Isotope Reactor, and the Institut Laue-Langevin, shows the quantitative reconstruction of the underlying primary spectrum across a wide range of transmission conditions, including strongly attenuating samples. Here, the method provides a stable, model-agnostic framework for multiple-scattering correction in SANS and enables consistent structural interpretation across instruments and scattering regimes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Multiphysics Analyses of the Protected and Unprotected Loss of Forced Cooling Accidents in the HTR-PM

Here, we present the multiphysics simulation results for the protected pressurized and depressurized loss of forced cooling (PLOFC and DLOFC) events in the High-Temperature gas-cooled Reactor--Pebble-bed Module (HTR-PM) equilibrium core using the Griffin-Pronghorn coupled code system. Additionally, this paper discusses the strategy for estimating the spontaneous fission neutron source needed for unprotected events and re-criticality calculations. The solutions of the protected PLOFC and DLOFC events were verified against similar solutions obtained for temperature evolutions from the open literature. Both the average and maximum pebble surface temperatures behaved as expected during the DLOFC and remained below 1800 K. The PLOFC results are highly dependent on the ability to resolve the natural circulation in the core, which is impacted by the mesh resolution in Pronghorn. Furthermore, we present the results of the unprotected DLOFC transient to predict the timing of the re-criticality event, which occurred 47 hours after the onset of the transient, and the new steady-state power of 1.3 MW.

42 - ENGINEERING↗

Stellarator fusion systems enabled by arrays of planar coils

We present an overview of a novel electromagnetic coil configuration for stellarators and its application to two near-term fusion systems. The novel coil configuration is the planar coil stellarator, able to implement precisely-quasisymmetric 3D magnetic fields using a set of planar, plasma-encircling coils and a set of planar, field-shaping coils situated on a surface surrounding the plasma. This configuration combines the stellarator’s advantages of steady-state operation, stability, low recirculating power fraction, and a mature physics basis, with the benefits of using simpler, planar coils which allow for a maintenance scheme leveraging large ports, and the ability to control magnets individually. The initial near-term use case considered is a steady state deuterium–deuterium stellarator neutron source, called Eos. The second near-term use case considered is a deuterium–tritium stellarator fusion pilot plant, called Helios, that would be approximately twice the linear dimension of the Eos design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of PMTs for the JSNS 2 experiment

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate γ-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons from scintillation are observed by 120 Photomultiplier Tubes (PMTs). A total of 130 PMTs for the JSNS 2 experiment were both donated by other experiments and purchased from Hamamatsu. Donated PMTs were purchased around 10 years ago, therefore JSNS 2 did pre-calibration of the PMTs including the purchased PMTs. 123 PMTs demonstrated acceptable performance for the JSNS 2 experiment, and 120 PMTs were installed in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The JSNS 2 data acquisition system

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of the nEDM@SNS light collection system efficiency

Here, a system for collecting the scintillation light produced by the capture of ultra-cold neutrons (UCN) on polarized 3 He is discussed and results from simulations of its performance are presented. This system will be implemented in nEDM@SNS, the experiment searching for the neutron electric dipole moment (nEDM) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. Simulation results show that the light collection system detects on average 17 photoelectrons per UCN- 3 He capture event (sufficient to generate a robust signal), reconstructs the event location in the beam direction to approximately 3 cm accuracy, detects capture events with a high and spatially uniform efficiency (0.95 with 1% variation), and rejects greater than 50% of beta decay background events.

47 OTHER INSTRUMENTATION↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗