Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Air temperature measurement

A coupled pair of identical film-mounted spherical bead thermistors serve as air temperature sensors aboard both Balloons 8-a and 8-b. The 8-a payload was reeled downward approximately 200 m beneath the balloon. The thermistor mounts were arranged in such a way so that when solar radiation was incident in a direction which was perpendicular to one film, then the direction of the incident solar ray was parallel to the second film. As the payload rotated during the flight (its rotation rate relative to the earth's magnetic field was sensed by a magnetometer), the temperature of each sensor varied depending on the orientation of the film surfaces with respect to the sun.

Ballard, H. N.↗

Voyager 1 and 2 Preliminary Observations Within Interplanetary Space of Upstream Suprathermal < 6 KeV Electrons Evidently Connected to Jupiter’s Bow Shock

We present for the first time the Voyager 1 and 2 plasma instrument observations within the interplanetary space of upstream suprathermal E < 6 keV electrons during times when close < 100 RJ from Jupiter’s bow shock. These measurements are a biproduct of our recovery of the Voyager Jupiter flyby measurements of the plasma electrons made by the Plasma Science Experiment (PLS) (Bridge et al., 1977). The initial ion and electron plasma observations were first reported by Bridge et al. (1979a, b). The periods were chosen to follow those reported by Zwickl et al. (1981) using energetic particle data with E ≥ 30 keV from the Low Energy Charged Particle (LECP) instrument (Krimigis et al., 1977). For this study we also use Voyager magnetic field data (Ness et al., 1979a, b) which is critical for this study. Basically, whenever the interplanetary magnetic field is nearly radially aligned relative to the spacecraft sun line, connection to the Jovian bow shock is believed to occur and one would expect those times when the keV suprathermal electron would be observed, but we also see them when the field is not radial but close to Jupiter’s bow shock. Whenever the magnetic field is radial the plasma instrument’s D cup or side sensor, which makes the electron observations (10 eV ≤ E ≤ 6 keV), is viewing ∼ 90 degree pitch angle electrons but evidently its wide field-of-view (FOV) allows one to see the keV electrons assumed to be field aligned. So, we will be looking into FOV alignment issues relative to the local magnetic field vector and any evidence for pitch angle scattering by plasma waves (see Scarf et al., 1981) that might broaden their width in pitch angle and allow their detection.

E C Sittler, Jr↗

The Electromagnetic Compatibility (EMC) Design Challenge for Scientific Spacecraft Powered by a Stirling Power Converter

A 55 We free-piston Stirling Technology Demonstration Convertor (TDC) has been tested as part of an evaluation to determine its feasibility as a means for significantly reducing the amount of radioactive material required compared to Radioisotope Thermoelectric Generators (RTGs) to support long-term space science missions. Measurements were made to quantify the low frequency magnetic and electric fields radiated from the Stirling's 80 Hertz (Hz) linear alternator and control electronics in order to determine the magnitude of reduction that will be required to protect sensitive field sensors aboard some science missions. One identified "Solar Probe" mission requires a 100 dB reduction in the low frequency magnetic field over typical military standard design limits, to protect its plasma wave sensor. This paper discusses the electromagnetic interference (EMI) control options relative to the physical design impacts for this power system, composed of 3 basic electrical elements. They are (1) the Stirling Power Convertor with its linear alternator, (2) the power switching and control electronics to convert the 90 V, 80 Hz alternator output to DC for the use of the spacecraft, and (3) the interconnecting wiring including any instrumentation to monitor and control items 1 and 2.

Sargent, Noel B.↗

Intensified charge coupled devices for ultra low light level imaging

Development of a sensor incorporating a CCD and photocathode for operation in the electron bombarded mode in both a magnetic and an electrostatic focussed, gated configuration is described. Initial format size is 100 x 160 pixels with eventual growth to 400 x 400 pixels. The sensor is part of a digital camera system which includes the low level video conditioning electronics, a camera controller, a high speed buffer memory, and digital recording and display electronics. The memory uses CMOS/SOS and has a capacity of 1.6 Mbits with operating rates of 48 Mbits/sec. Individual frames are co-added to provide wide dynamic range and photometric precision better than 1%. A 4-bit video quantization is used to increase the photon counting detection rate before coincidence losses become serious.

Sobieski, S.↗

Nematic transitions in iron pnictide superconductors imaged with a quantum gas

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) uses an atomic Bose–Einstein condensate to measure magnetic fields emanating from solid-state samples. The quantum sensor does so with unprecedented d.c. sensitivity at micrometre resolution, from room to cryogenic temperatures. An additional advantage of the SQCRAMscope is the preservation of optical access to the sample so that magnetometry imaging of, for example, electron transport may be performed in concert with other imaging techniques. Here, we apply this multimodal imaging capability to the study of nematicity in iron pnictide high-temperature superconductors, where the relationship between electronic and structural symmetry breaking resulting in a nematic phase is under debate. We combine the SQCRAMscope with an in situ microscope that measures optical birefringence near the surface. This enables simultaneous and spatially resolved detection of both bulk and near-surface manifestations of nematicity via transport and structural deformation channels, respectively. By performing local measurements of emergent resistivity anisotropy in iron pnictides, we observe sharp, nearly concurrent transport and structural transitions. More broadly, these measurements demonstrate the SQCRAMscope’s ability to reveal important insights into the physics of complex quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rolling Root Mean Square Based Multimodal Anomaly Detection for Real Time Monitoring of Smart Grid

Reliable real-time monitoring is valuable for maintaining the operational integrity of modern electrical smart grids. Deployment of heterogeneous sensing technologies in substations has enabled high-resolution, multichannel waveform monitoring, but also introduces challenges for anomaly detection due to noise, baseline drift, and modality-dependent signal characteristics. In this work, we present a computationally efficient unsupervised method for multimodal event detection based on Rolling Root Mean Square based Event Detection (RRMSED). The method is developed using in-house, field deployed sensors collecting data at a utility substation. The sensing system comprises voltage and current sensors, triaxial accelerometers, and magnetometers, collectively capturing electrical, vibrational, and magnetic waveform measurements at high temporal resolution. RRMSED operates by extracting rolling RMS energy features and their first-order temporal differences from consecutive waveform segments for each channel and then applying channel-specific statistical thresholds learned from historical data. A persistence-based exceedance logic is employed to robustly identify transient events while suppressing impulsive noise, and to provide precise temporal localization with high resolution. The framework is designed for continuous server-side operation and can be deployed in real time without requiring complex models. Experiments on simulated waveform data with known ground truth demonstrate low false positive (FP) and false negative (FN) rates. Application to real substation data shows RRMSED to identify events that are not captured by conventional monitoring indicators including fast transient detection algorithm currently deployed in the system. These results indicate that rolling RMS based features provide an effective and practical basis for real-time multimodal event detection in smart-grid substations.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Optical nanofiber testbeds for benchmarking membrane-waveguide photonic integrated circuit platforms toward on-chip quantum inertial sensing

Recent advances in cold atom interferometry with optical and magnetic atom guides have set the stage for quantum inertial sensors capable of operating in dynamic environments. In this work, we present three key innovations—evanescent-field (EF) atom guides, optical nanofiber testbeds, and membrane-waveguide photonic integrated circuit (PIC) platforms—to advance EF-guided atom interferometry. First, we demonstrate EF atom guides on optical nanofiber testbeds, which serve as performance benchmarks for our membrane-waveguide PIC platforms. Second, we achieve low-power (⁠ ~ 5 mW) guiding of freely moving, laser-cooled 133 Cs atoms in two-color, traveling-wave EF optical dipole traps at the novel, heat-efficient magic wavelengths of 793 and 937 nm (i.e., “793/937-nm EF atom guides”). Concurrently, we design and fabricate membrane-waveguide PIC platforms for these EF atom guides; in our prior work, we showed that these structures safely accommodate 4–6 times the required optical trap power under vacuum and enable dense cold atom generation via magneto-optical trapping in the vicinity of the optical wavguide for efficient loading. Third, we verify preserved atomic coherence via microwave fields and EF-coupled Doppler-free Raman beams; to our knowledge, this is the first report of coherence fringes driven by co-propagating EF-coupled Raman beams with only 150 nW of total optical power. By providing a direct comparison between optical nanofiber testbeds and membrane-waveguide PIC platforms, our results lay critical groundwork for the on-chip realization of EF-guided atom interferometry and the development of fully integrated, compact, lightweight, and low-power quantum accelerometers and gyroscopes.

Orozco, Adrian [Sandia National Laboratories (SNL-↗

Development of magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals. Several mitigations will be enacted, including mu-metal shielding and a suite of magnetometers. This presentation will discuss the development of a magnetic field monitoring system based on commercial magneto-inductive sensors to be installed at several points along the interferometer.

Arce, Edwin [Unlisted; Fermilab]↗

Digital multichannel photometry with digicons

The digital system is described and compared to other sensor systems. The digicon system starts with a photocathode, has magnetic focusing of the accelerated photoelectrons, and the electrons hit an array of solid-state diodes. These characteristics, however, are the only ones which are applicable to both the digicon and the other systems. With the digicon system, instead of attempting to read the resulting charges on the diodes by probing electrons, or by a charge transfer out, an actual physical wire is connected to each separate diode. This provides a huge advantage in improved signal-to-noise ratio.

Mcilwain, C. E.↗

Ion mass spectrometer

An ion mass spectrometer is described which detects and indicates the characteristics of ions received over a wide angle, and which indicates the mass to charge ratio, the energy, and the direction of each detected ion. The spectrometer includes a magnetic analyzer having a sector magnet that passes ions received over a wide angle, and an electrostatic analyzer positioned to receive ions passing through the magnetic analyzer. The electrostatic analyzer includes a two dimensional ion sensor at one wall of the analyzer chamber, that senses not only the lengthwise position of the detected ion to indicate its mass to charge ratio, but also detects the ion position along the width of the chamber to indicate the direction in which the ion was traveling.

Neugebauer, M.↗

Analysis of electromagnetic fields on an F-106B aircraft during lightning strikes

Information on the exterior electromagnetic environment of an aircraft when it is struck by lightning has been obtained during thunderstorm penetrations with an F-106B aircraft. Electric and magnetic fields were observed, using mainly time-derivative type sensors, with bandwidths to 50 MHz. Lightning pulse lengths ranging from 25 ns to 7 microsec have been recorded. Sufficient high-frequency content was present to excite electromagnetic resonances of the aircraft, and peaks in the frequency spectra of the waveforms in the range 7 to 23 MHz are in agreement with the resonant frequencies determined in laboratory scale-model tests. Both positively and negatively charged strikes were experienced, and most of the data suggest low values of peak current.

Trost, T. F.↗

Magnetic bearings for an optical disk read/write head

A program is described whose aim is to establish the technical feasibility of developing magnetic bearings for an optical disk buffer for use in a spacecraft environment. The approach taken was to develop the specifications for the magnetic bearings and define the hardware configuration, controller characteristics, position sensors, and electronic functions required.

Hockney, Richard↗

Modelling and control of a rotor supported by magnetic bearings

In this paper we develop a dynamical model of a rotor and the active magnetic bearings used to support the rotor. We use this model to develop a stable state feedback control of the magnetic bearing system. We present the development of a rigid body model of the rotor, utilizing both Rotation Matrices (Euler Angles) and Euler Parameters (Quaternions). In the latter half of the paper we develop a stable state feedback control of the actively controlled magnetic bearing to control the rotor position under inbalances. The control law developed takes into account the variation of the model with rotational speed. We show stability over the whole operating range of speeds for the magnetic bearing system. Simulation results are presented to demonstrate the closed loop system performance. We develop the model of the magnetic bearing, and present two schemes for the excitation of the poles of the actively controlled magnetic bearing. We also present a scheme for averaging multiple sensor measurements and splitting the actuation forces amongst redundant actuators.

Gurumoorthy, R.↗

Testing of Gyroless Estimation Algorithms for the FUSE Spacecraft

The Far Ultraviolet Spectroscopic Explorer (FUSE) is equipped with two ring laser gyros on each of the spacecraft body axes. In May 2001 one gyro failed. It is anticipated that all of the remaining gyros will also fail, based on intensity warnings. In addition to the gyro failure, two of four reaction wheels failed in late 2001. The spacecraft control, now relies heavily on magnetic torque to perform the necessary science maneuvers. The only sensor available during slews is a magnetometer. This paper documents the testing and development of gyroless attitude and rate estimation algorithms for FUSE. The results of two approaches are presented, one relies on a kinematics model for propagation, a method used in aircraft tracking, and the other is a traditional Extended Kalman filter that utilizes Euler's equations in the propagation of the estimated rate. Finally, the question of closed-loop stability is addressed. The ability of the controller to meet the science slew requirements, without the gyros, is tested through simulations.

Thienel, Julie↗

Iodine Satellite

This project is a collaborative effort to mature an iodine propulsion system while reducing risk and increasing fidelity of a technology demonstration mission concept. 1 The FY 2014 tasks include investments leveraged throughout NASA, from multiple mission directorates, as a partnership with NASA Glenn Research Center (GRC), a NASA Marshall Space Flight Center (MSFC) Technology Investment Project, and an Air Force partnership. Propulsion technology is often a critical enabling technology for space missions. NASA is investing in technologies to enable high value missions with very small and low-cost spacecraft, even CubeSats. However, these small spacecraft currently lack any appreciable propulsion capability. CubeSats are typically deployed and drift without any ability to transfer to higher value orbits, perform orbit maintenance, or deorbit. However, the iodine Hall system can allow the spacecraft to transfer into a higher value science orbit. The iodine satellite (iSAT) will be able to achieve a (Delta)V of >500 m/s with <1 kg of solid iodine propellant, which can be stored in an unpressurized benign state prior to launch. The iSAT propulsion system consists of the 200 W Hall thruster, solid iodine propellant tank, a power processing unit, and the necessary valves and tubing to route the iodine vapor. The propulsion system is led by GRC, with critical hardware provided by the Busek Co. The propellant tank begins with solid iodine unpressurized on the ground and in-flight before operations, which is then heated via tank heaters to a temperature at which solid iodine sublimates to iodine vapor. The vapor is then routed through tubing and custom valves to control mass flow to the thruster and cathode assembly. 2 The thruster then ionizes the vapor and accelerates it via magnetic and electrostatic fields, resulting in thrust with a specific impulse >1,300 s. The iSAT spacecraft, illustrated in figure 1, is currently a 12U CubeSat. The spacecraft chassis will be constructed from aluminum with a finish to prevent iodine-driven corrosion. The iSAT spacecraft includes full three-axis control using wheels, magnetic torque rods, inertial management unit, and a suite of sensors and optics. The spacecraft will leverage heat generated by spacecraft components and radiators for a passive thermal control system.

Dankanich, John↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ∼2 sq. m of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

Simon R. Bandler↗

The Cusp Plasma Imaging Detector (Cupid) Cubesat Observatory: Instrumentation

The Cusp Plasma Imaging Detector (CuPID) CubeSat observatory is a 6U CubeSat designed to observe solar wind charge exchange in magnetospheric cusps to test competing theories of magnetic reconnection at the Earth’s magnetopause. The CuPID is equipped with three instruments, namely, a wide field-of-view (4.6° × 4.6°) soft x-ray telescope, a micro-dosimeter suite, and an engineering magnetometer optimized for the science operation. The instrument suite has been tested and calibrated in relevant environments, demonstrating successful design. The testing and calibration of these instruments produced metrics and coefficients that will be used to create the CuPID mission’s data product.

Magnetospheric dynamics↗

Study of magnetic perturbations on SEC vidicon tubes

A laboratory measurements program was conducted to determine the tolerances that must be imposed to achieve optimum performance from SEC-vidicon data sensors in the LST mission. These measurements along with other data were used to formulate recommendations regarding the necessary telemetry and remote control for the television data sensors when in orbit. The study encompassed the following tasks: (1) Conducted laboratory measurements of the perturbations which an external magnetic field produces on a magnetically focused, SEC-vidicon. Evaluated shielding approaches. (2) Experimentally evaluated the effects produced on overall performance by variations of the tube electrode potentials, and the focus, deflection and alignment fields. (3) Recommended the extent of ground control of camera parameters and camera parameter telemetry required for optimizing the performance of the television system in orbit. The experimental data are summarized in a set of graphs.

Long, D. C.↗