Novel Ground States and Phase Transitions in Cobalt-Based Compounds and Heterostructures. Final report, 03/15/2006 - 03/14/2019

This final report summarizes work performed over a 12-year period at the University of Minnesota, focused on magnetic and electronic properties of complex oxide materials, particularly studied with neutron scattering methods. These materials are of high basic scientific interest, but at the same time underpin some key energy technologies. The final report provides a succinct summary of the technical achievements, scientific advances, and technological relevance of the research. Specific products from the research include 55 high quality journal publications, and 73 invited presentations on this scientific content. The results of this work have thus been disseminated broadly, to a variety of scientific and engineering audiences.

36 MATERIALS SCIENCE↗

Cost of saving natural gas through efficiency programs funded by utility customers: 2012–2017

This study estimates the cost of saving a therm of natural gas from energy efficiency programs funded by utility customers during the period 2012 to 2017. Berkeley Lab researchers compiled and analyzed efficiency program data reported by investor-owned utilities and other program administrators in a dozen states representative of the four U.S. Census regions — Arkansas, California, Connecticut, Iowa, Massachusetts, Michigan, Minnesota, New Jersey, New York, Oklahoma, Rhode Island and Utah. Depending on the year, the dataset accounts for about 50 percent to 70 percent of annual national spending on natural gas efficiency programs. The estimated cost of saving natural gas during the study period is $0.40 per therm. The analysis also includes estimates of the program administrator cost of saved energy for three core sectors for natural gas: commercial and industrial, residential, and low-income households. It aggregates these sectors to provide regional and national values. Our metrics include savings-weighted averages, unweighted medians, and interquartile ranges (25th and 75th percentiles) of the levelized program administrator cost of saving gas, in constant 2017 dollars. In addition, the study analyzes cost trends during the study period, finding that average program costs trended downward. The U.S. Department of Energy’s Building Technologies Office supported this work.

03 NATURAL GAS↗

A Dark Matter Search Using the Final SuperCDMS Soudan Dataset and the Development of a Large-Format, Highly-Multiplexed, Athermal-Phonon-Mediated Particle Detector

Over the past eighty years, numerous complementary observations of our universe have indicated that our current description of physics is far from complete. The “or- dinary matter”, such as electrons, protons, photons and neutrons, that constitutes the bulk of all human physical experiences is actually only a minority (about 16%) of the total mass of the universe. The remaining 84% is very poorly understood, but has profound effects on the dynamics and evolution of our universe. Because it does not interact with light, and is not observable in telescopes on earth, this extra mass is usually referred to as “dark matter”. Although the dark matter is poorly understood, Weakly Interacting Massive Particles (WIMPs) are a well-motivated candidate that can be directly detected via a non-gravitational interaction with nor- mal matter, potentially allowing for direct terrestrial detection and characterization of this dark matter. This dissertation is focused on this direct WIMP detect ion and will be broken into two main parts. The first part focuses on the blinded analysis of roughly three years of data collected from March 2012 to November 2015 by the SuperCDMS Soudan experiment. SuperCDMS Soudan consists of an array of 15, 0.6-kg, cryogenic, Ge iZIP particle detectors situated in a decommissioned iron mine in remote northern Minnesota. This analysis is optimized to be sensitive to theoretical WIMP masses above 10 GeV/$c^2$ . This result set the strongest limits for WIMP–germanium-nucleus interac- tions for WIMP masses greater than 12 Gev/$c^2$ and can be found here [1]. The second part focuses on the development new kind of particle detector in the style of a SuperCDMS iZIP, designed to simplify fabrication and readout, improve phonon-based position reconstruction, and help to scale to larger target arrays. These detectors replace the TES-based phonon sensors of the iZIP with Microwave Kinetic Inductance Detectors (MKIDs).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for Low-Mass Dark Matter with SuperCDMS Soudan Detectors

SuperCDMS is a direct-detection dark matter (DM) experiment that uses cryogenically cooled germanium and silicon detectors to search for interac- tions between DM particles and detector nuclei, and in this thesis I describe my contributions to the experiment. I start with a brief review of DM and motivate the possibility of its de- tection in underground laboratories with sensitive detectors, and I review the SuperCDMS detector fundamentals. Then I focus on detector develop- ment for the future generation of the experiment, which will deploy an array of detectors at SNOLAB in Sudbury, Canada. Specifically I describe char- acterization of prototype detectors from surface facility testing, and discuss measurements of critical values that determine the detectors’ sensitivity to DM particles, such as the baseline resolution and the phonon collection ef- ficiency. I also describe analysis techniques developed to measure intrinsic detector noise in a high radiation environment such as a surface test facility. In the final chapters I describe a DM search analysis using four months of data from operation of SuperCDMS detectors in the Soudan Mine in northern Minnesota. I discuss how a particular detector operating mode, called CDMSlite, lowers the energy threshold of the detectors in order to improve the sensitivity to low-mass DM particles. I also present new analysis techniques that optimize the sensitivity to low-mass DM particles, including noise discrimination with multivariate classifiers, instrumental background modeling, and a profile likelihood signal and background fitting approach. In this analysis we set an upper limit on the DM-nucleon scattering cross section in germanium that is a factor of 2.5 improvement over the previous CDMSlite result for a DM mass that is five times the proton rest mass.

79 ASTRONOMY AND ASTROPHYSICS↗

100th Anniversary of the discovery of Ferroelectricity: How did it impact the Current Day Physics

Ferroelectric phenomenon in materials was identified for the first time about 100 years ago in 1920 (paper presented at the American Physical Society (APS) Meeting in Washington, DC, April 1920), at the University of Minnesota, MN, USA; by then a graduate student Joseph Valasek working under the supervision of Prof. W. F. G. Swann. Before this announcement, some prominent physicists had envisaged and even predicted the possibility of an analogous electrical behavior in some materials to that of the well-established hysteresis behavior of magnetic materials. Debye’s work tried to put the concept of Curie temperature in some solids in 1912 but it Schrodinger in the same year who formalized the term ferroelectricity. The names ferroelectrics, ferroelectricity, etc. are fully symbolic of the hysteresis loop-like behavior originally displayed by the magnetic materials. Later on when the physics of ferroelectrics was formalized, most of the terminology, e.g. Curie constant, Curie temperature, etc. that characterized the hysteresis loop or its related characteristics, was inherited from the magnetic materials. Over the years basic ferroelectricity concepts were significantly developed. The observed ferroelectric hysteresis loop between electric polarization vs applied electric field in the then well-known material, Rochelle salt, was presented at the April meeting of the APS, held at, then known as, the National Bureau of Standards or NBS (currently known as the National Institute for Standards and Technology or NIST). Interestingly, even though Valasek submitted the abstract but it was presented by Swann (and Valasek was not present). It happened to be a unique case of the earlier predictions but it did not catch the attention of many researchers working in the field of electronics. Whatever the reason, there was a little attention paid to this newly identified effect in Rochelle salt in 1920s. In late 1920, Valasek’s paper was submitted to Physical Review and that appeared in April 1921. Both ferroelectricity and ferromagnetism are the observational or experimental characteristics of a special class of materials which were not predicted by any basic theoretical approaches to start with at that time.

36 MATERIALS SCIENCE↗

Effects of Experimental Warming and Elevated CO 2 on CO 2 and CH 4 Fluxes in an Ombrotrophic Black-Spruce. Final Report

High latitude peatlands and permafrost soils contain nearly half of the soil carbon pool on Earth. The potential for large soil C stocks in peatlands and permafrost to become a positive feedback to climate change by increasing net emissions of CO₂ and CH₄ to the atmosphere is a subject of grave concern. This research was conducted at the Spruce and Peatland Responses Under Changing Environments (herein SPRUCE) experimental facility, located in the USDA’s Marcell Experimental Forest in northern Minnesota. The site is dominated by Picea mariana [herein black spruce], ericaceous shrubs and Sphagnum spp. Ten 12m-diameter open top chambers expose portions of the 8.1-ha S1 bog to warming up to +9°C in 2.25°C increments at ambient and elevated CO₂ (eCO₂, 900ppm). The Finzi lab group began manual measurements of CO₂ and CH₄ fluxes and their C-isotopic compositions in 2014. With funding from the DOE-TES program automated measurements of these species began in 2015. With a one-year no cost extension we were able to make measurements through the 2018 growing season. Across the study period we find that experimental warming of the peatland significantly increases the flux of CO₂ and CH₄ to the atmosphere. The highest temperature treatments had the highest fluxes. As peatlands have complex topography and water table dynamics, many of these results were contingent upon the topographic location in which the measurements were made. In the raised portions of the peatland divorced from the water table, fluxes of CO₂ were high and fluxes of CH₄ were low. By contrast, in the lower portions of the peatland surface, which is at or very near the water table, fluxes of CH₄ were substantially higher. A significant fraction of the total annual CH₄ flux was derived from episodic ebullitive fluxes. The occurrence and size of these ebullitive fluxes also increased with temperature. Experimental fumigation of the black spruce peatland with elevated concentrations of atmospheric CO₂ [herein eCO₂] also had significant effects on emissions of greenhouse gasses. In general these effects were far more subtle than the effects of rising temperature. This indicates that temperature change more than atmospheric chemistry changes are affect the belowground cycle of C in the peatland. Overall, this study shows that boreal peatlands are highly sensitive to changes in temperature. The warmer it becomes the more C will be lost from the peatland to the atmosphere. This appears to create a positive feedback loop that is likely to enhance the concentration of greenhouse gases in the atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Assessing Opportunities and Challenges for Streamlining Interconnection Processes

As part of the Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, Electric Power Research Institute conducted a survey of existing utility interconnection practices and evaluated opportunities for streamlining them. The report highlights opportunities for electric utilities to improve transparency and automate administrative processes with options to fit the level of interconnections that utilities are experiencing.

14 SOLAR ENERGY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Midwest EVOLVE (Midwest Electric Vehicle Opportunities: Learning, eVents, Experience)

The Midwest Electric Vehicle Opportunities: Learning, eVents, Experience (Midwest EVOLVE) project was a 45 month, seven-state effort to introduce electric vehicles to the public, workplaces, corporate fleets and auto dealership staff. Midwest EVOLVE projects were planned and completed in the following states: Illinois, Indiana, Michigan, Minnesota, North Dakota, Ohio, and Wisconsin. The project was coordinated by the American Lung Association of the Upper Midwest (ALAUM), dba Twin Cities Clean Cities Coalition (TC4).

33 ADVANCED PROPULSION SYSTEMS↗

Interactive Radiation Detection Instrumentation

This presentation will be presented at the International Joint Meeting on Nuclear/Radiological Security for Major Public Events in Minneapolis, Minnesota during January 30 - February 2, 2018 sponsored by DOE/NNSA Office of Nuclear Incident Policy and Cooperation and the International Atomic Energy Agency. .

61 RADIATION PROTECTION AND DOSIMETRY↗

Best Practices Guide: Benchmarking Energy Efficiency in Laboratories

Purpose and Audience A wide spectrum of laboratory owners, ranging from universities to federal agencies, have explicit goals for energy efficiency and greenhouse gas reductions in their facilities. For example, new federal buildings and major renovations of existing buildings are to reduce fossil fuel-generated energy consumption by 90% in 2025, and 100% in 2030, compared with a 2003 baseline (FEMP n.d.). Minnesota SB2030 standard requires achieving an 80% reduction from the average building baseline for commercial, institutional, and industrial buildings (SB2030 n.d). A laboratory—new or existing—is much more likely to meet energy efficiency goals if quantitative metrics and targets are explicitly specified and tracked over the life cycle of the building, from design through construction, commissioning, operations, and renovations. If efficiency targets are not explicitly and properly defined, any additional capital costs or design time associated with attaining higher efficiencies can be difficult to justify relative to other priorities. The purpose of this guide is to provide guidance on how to specify and compute energy efficiency metrics and benchmarks for laboratories, at the whole-building as well as the system level. The information in this guide can be used to incorporate quantitative metrics and targets into new construction or retrofit of existing facilities. For information on strategies and technologies to achieve energy efficiency, the reader is referred to I2SL resources, including technology best practice guides and case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2009 National Biodiesel Foundation Biodiesel Infrastructure Project [Final Report]

The National Biodiesel Foundation (NBF) worked with industry partners to displace nearly 10 millions of gallons of petroleum-based diesel with biodiesel by installing or modifying terminals throughout the United States (US). The original grant was to install seven terminals, but with DOE’s approval and using existing grant funds, the project provided funds for an additional terminal. The primary goal of this project was to displace 86 million gallons of petroleum based diesel with biodiesel by installing seven terminals. Although the project installed eight terminals, it only resulted in displacing approximately 9.7 million gallon. However, the project (through the Harms Oil installation) enabled the state of Minnesota to increase its biodiesel mandate from 5% to 10%, increase biodiesel demand at other MN terminals by an addition 25 million. Further, this state mandate will grow demand to 120 million gallons annually by 2018, if the state’s biodiesel mandate is fully enforced. None of this would have been possible without the Harm’s Oil terminal funded under this grant.

09 BIOMASS FUELS↗

Extraction of Neutrino Oscillation Parameters using a Simultaneous Fit of $\nu_{\mu}$ Disappearance and $\nu_{e}$ Appearance data with the NOvA Experiment

This thesis presents the analyses and results of the $\nu_{\mu} \rightarrow \nu_{\mu}$ disappearance and $\nu_{\mu} \rightarrow \nu_{e}$ appearance due to neutrino oscillations using 8.85 $\times$ 10$^{20}$ protons on target (POT) equivalent of data collected by the NOvA experiment. The data analyzed in this thesis was collected from February 06, 2014 to February 20, 2017. NOvA is an accelerator-based, long-baseline neutrino oscillation experiment and uses the two detector set-up to study the phenomenon of neutrino oscillation using a beam of muon neutrinos produced at Fermilab. One NOvA detector is placed within the Fermilab campus, 100 m underground, at a distance of 1 km from the neutrino source and is called the Near Detector (ND). The ND is 300 ton in mass and smaller in size than the Far Detector (FD) which is 14 kton in mass and is placed 810 km away from the neutrino source in Ash River, Minnesota (MN). Both ND and FD are made of the same material and are functionally identical. The ND being closer to the neutrino source, analyzes the neutrino beam before the neutrinos oscillate and the FD analyzes the neutrinos after oscillations. The ND is used to predict the signal and background expectations in the FD. The similarity in the ND and FD help to reduce the systematic uncertainties in the FD prediction. The combined oscillation fit to the $\nu_{\mu} \rightarrow \nu_{\mu}$ disappearance and $\nu_{\mu} \rightarrow \nu_{e}$ appearance gives the best fit values of the $\Delta m^{2}_{32}$, $\sin^{2}{\theta_{32}}$ and $\delta_{CP}$ oscillation parameters and are presented in this thesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-baseline Sterile Neutrino Searches in the NOvA Experiment

Experimental high energy physics constitutes the experimental investigation of the fundamental building blocks of matter and radiation and their interactions. These fundamental building blocks are classified as bosons and fermions. Neutrinos are fermions that come under the lepton category. According to the Standard Model of particle physics, they are massless, neutral particles that interacts with matter only through weak force and comes in three different flavors. Neutrinos exhibit a characteristic property, known as the neutrino oscillation. Neutrino oscillation is the the change of neutrino from one flavor to another flavor as they propagates in space. This phenomenon is only possible if the neutrinos are massive. The reported anomalous result from LSND and MiniBooNE experiments demanded the existence of a fourth kind of neutrino, at the same time, LEP experimental result confirms that only three active neutrino can exist. So if they exists, this fourth kind of neutrino can’t interact through weak force or they can be called as sterile neutrino. Some of the experiments favored the existence of sterile neutrinos, at the same time, there are some other experiments that disfavors their existence. So the search for the sterile neutrinos is very active in the field of experimental neutrino physics. NOvA is a long-baseline experiment with two functionally identical detectors, a Near Detector (ND) at Fermilab and a Far Detector at Ash River, Minnesota which is 810 km far away from the ND. They are offaxis detectors that lie 14.6 mrad off from the beam axis. This enables the detector to receive a neutrino beam with energy peak at 2 GeV. The NOvA experiment is designed to run with both the neutrino beam and antineutrino beam and NOvA has the potential to search for the existence of sterile neutrinos. This thesis is based on the sterile neutrino search by looking at the depletion of the neutral-current (NC) energy spectrum of neutrinos at the FD. Since NC events are not sensitive to three flavor oscillation, any depletion of NC events at the FD indicates the existence of sterile neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding Mechanistic Controls of Heterotrophic CO 2 and CH 4 Fluxes in a Peatland with Deep Soil Warming and Atmospheric CO 2 Enrichment

This project was funded from August 1, 2016 – July 31, 2019 with a no-cost extension until July 31, 2020 (and built upon the PI-team’s previous work supported by DE-SC0008092 (June 2012 – September 2016)). Our project focused on the Spruce and Peatland Responses Under Changing Environments (SPRUCE: https://mnspruce.ornl.gov/) experiment taking place in the S1 Bog in the Marcell Experimental Forest in northern Minnesota, USA. The SPRUCE project is a unique whole-ecosystem experiment where a bog peatland is subjected to warming and atmospheric carbon dioxide (CO 2 ) enrichment. Deep peat heating of the soil profile (to a depth of at least 2 m) began in June of 2014 and was followed by whole-ecosystem warming in August of 2015. Warming treatments included +0 °C, +2.25 °C, +4.5 °C, +6.75 °C, and +9 °C above ambient temperatures, with 2 experimental chambers for each warming treatment. Half of these chambers received ambient atmospheric CO 2 concentrations, and starting in June of 2016, the other half received elevated atmospheric CO 2 concentrations (~ +500 ppm(v) above ambient). Our primary goal with this project was to explore the mechanistic controls of anaerobic carbon cycling – especially the dynamics of the potent greenhouse gas methane (CH 4 ) – within the SPRUCE experiment.

54 ENVIRONMENTAL SCIENCES↗

State Strategies to Bring Solar to Low- and Moderate-Income Communities

This Final Technical Report describes the goals, objectives, activities, results, and accomplishments of the State Strategies to Bring Solar to Low- and Moderate-Income Communities Project, managed by the Clean Energy States Alliance. This project enabled five states (Connecticut, Minnesota, New Mexico, Oregon, and Rhode Island) and the District of Columbia to develop and implement strategies for expanding market penetration of solar PV among LMI residents and communities. The project disseminated successful strategies and lessons learned from those states to other states and stakeholders across the country.

14 SOLAR ENERGY↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗