Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Conceptual design of a high reactive-power ferroelectric fast reactive tuner

We present a novel design of a ferroelectric fast reactive tuner (FE-FRT) capable of modulating mega-VAR reactive power on a submicrosecond timescale. The high reactive power capability of our design extends the range of applications of reactive tuners to numerous applications. We present a detailed analytical model of the performance of a megawatt-class reactive power device and benchmark it against finite-element method eigenmode and frequency domain electromagnetic simulations. We introduce new features, including an annulus design for the ferroelectric capacitors and capacitive window coupling to the cavity. We consider thermal design issues and nonlinear effects in the ferroelectric. The model covers several configurations, allowing control of the frequency of superconducting and normal-conducting cavities in a variety of applications and frequencies. We calculate that the FE-FRT designed should be capable of handling around 0.45 MVAR of reactive power with around 3 kW of resistive losses, providing a frequency tuning range of 8 kHz in an example of 400 MHz cavity geometry. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Nondestructive Evaluation of Carbon Fiber Reinforced Polymers

The American Society of Mechanical Engineers Boiler and Pressure Vessel Code requires repair and replacement of safety-related piping materials to meet the original Construction Code; however, no construction criteria currently exist for carbon fiber reinforced polymer (CFRP) materials in the nuclear industry. Although nondestructive examination (NDE) techniques for cast and wrought ferritic and austenitic steels are well established, licensees are increasingly deploying novel materials such as CFRP for which assessment of the use of NDE is required, as the inspectability of such materials and the influence of manufacturing processes on inspectability remain insufficiently understood. To address these gaps, Pacific Northwest National Laboratory (PNNL) evaluated the fabrication of several CFRP repair mockups and the effectiveness of NDE methods to support regulatory review of CFRP repairs in nuclear power plant applications. Representative flat-plate mockups containing realistic fabrication defects were manufactured and inspected using manual and automated tap testing, dynamic response spectroscopy (DRS), and ultrasonic testing (UT). The study identified significant fabrication variability, particularly in controlling defect size and epoxy thickness, which strongly influenced defect detectability by NDE methods. Tap testing was effective for shallow defects in thin epoxy configurations but unreliable for thicker repairs and deeper flaws. DRS demonstrated higher sensitivity to dry spots but produced unconfirmed indications for thicker plates, requiring further validation. Conventional UT, particularly at 1.0 MHz, showed the strongest overall capability for detecting a range of defects, although performance degraded with increasing repair thickness and complexity. The results highlight the need to better define critical defect sizes, develop reliable mockup fabrication methods, and validate NDE methods needed to support CFRP repairs.

36 MATERIALS SCIENCE↗

The impedance characteristic of a spherical probe in an isotropic plasma.

Experimental investigation of the impedance characteristic of a spherical plasma probe for a quantitative assessment of theoretical work, and of hydrodynamic or fluid theory in particular. A stable, low-temperature (about 500K) plasma was produced in nitrogen by a cold-cathode discharge, with a plasma frequency of the order of 15 MHz and with an electron collision frequency in the range from one to ten million per sec. Hydrodynamic probe theory was tested against the experimental results for the specific cases corresponding to the probe at floating potential and at space potential. Good agreement was obtained for both the real and imaginary parts. The real part of the impedance shows a peak near the plasma frequency, a small shift being explicable in terms of realistic sheath profiles. Electron density can thus be deduced rather accurately, and electron temperature approximately, on the basis of hydrodynamic theory. Accurate values of the electron-neutral collision frequency were also obtained for plasmas where the collision frequency was larger than 0.4 times the radian plasma frequency. At lower pressures the presence of collisionless or Landau damping was clearly established, and the more accurate kinetic theory is necessary to explain the experimental results.

Tarstrup, J.↗

Airoscope telemetry system

The AIROscope (Ames Infrared Observatory telescope) telemetry system is described from signal conditioning on the gondola to display and storage at the ground station. All analog and digital data from the systems and experiments on the gondola go to a PCM encoder which formats the data into 10-bit words. Therefore, 0.1-percent resolution is inherently available for experimental data. The coded bit stream directly modulates the carrier of the FM transmitter. To insure reliable transmission over a 650-km range an 11-watt FM transmitter operating at 1483.5 MHz is used on the gondola. Modulation is narrow band FM with a maximum deviation of plus or minus 500 kHz. The maximum modulation frequency is determined by the data bit rate which could be as high as 500 kbps. Presently, a rate of 20.48 kbps is used. The ground station receiving system includes a steerable antenna (19-db gain), preamplifier (21-db gain) and receiver. All data are recorded on a tape recorder. The recorded signal then can be played back through the PCM decommutator unit at a later time for detailed data analysis by the experimenter.

Pitts, K. J.↗

Determination of travelling ionospheric disturbances

A total of 35 days of Faraday rotation data was obtained from the ATS-6 radio beacon experiment operating with the closely spaced network of Elbert, Table Mountain, and Fort Morgan. The 140-MHz Faraday bandpass data are uncorrelated in the transmission range from 8 to 45 minutes. There are distinct, well correlated, and time-displaced maxima and minima that allow the calculation of the speed and direction of horizontal motions of plane fronts of disturbances in the ionosphere. For some selected events, velocities between 88 and 278 m/sec were obtained.

Degenhardt, W.↗

An ultrasonic plethysmograph for space flight applications

The development of an ultrasonic plethysmograph based on the transit time measurement principle is reported, which meets the space-imposed requirements for evaluating cardiovascular deconditioning. It consists of a pulse generator, pulse receiver amplifier, voltage comparator, synchronous pulse generator, elapsed time counter, and transmit and receive piezoelectric crystals resonant at 2 MHz and of 3 mm diameter. The transit time for an ultrasonic pulse to propagate across a limb cross section is computed in a digital fashion using a 32 MHz clock, and resolution is 0.049 mm with the range being approximately 200 mm. Experimental results regarding dynamic system response were found comparable in both accuracy and sensitivity to those of a Whitney strain gage using a 50 torr venous occlusion.

Bhagat, P. K.↗

Global Positioning System Time Transfer Receiver (GPS/TTR) prototype design and initial test evaluation

Time transfer equipment and techniques used with the Navigation Technology Satellites were modified and extended for use with the Global Positioning System (GPS) satellites. A prototype receiver was built and field tested. The receiver uses the GPS L1 link at 1575 MHz with C/A code only to resolve a measured range to the satellite. A theoretical range is computed from the satellite ephemeris transmitted in the data message and the user's coordinates. Results of user offset from GPS time are obtained by differencing the measured and theoretical ranges and applying calibration corrections. Results of the first field test evaluation of the receiver are presented.

Oaks, J.↗

A Multichannel Averaging Phasemeter for Picometer Precision Laser Metrology

The Micro-Arcsecond Metrology (MAM) team at the Jet Propulsion Laboratory has developed a precision phasemeter for the Space Interferometry Mission (SIM). The current version of the phasemeter is well-suited for picometer accuracy distance measurements and tracks at speeds up to 50 cm/sec, when coupled to SIM's 1.3 micron wavelength heterodyne laser metrology gauges. Since the phasemeter is implemented with industry standard FPGA chips, other accuracy/speed trade-off points can be programmed for applications such as metrology for earth-based long-baseline astronomical interferometry (planet finding), and industrial applications such as translation stage and machine tool positioning. The phasemeter is a standard VME module, supports 6 metrology gauges, a 128 MHz clock, has programmable hardware averaging, and a maximum range of 232 cycles (2000 meters at 1.3 microns).

Halverson, Peter G.↗

Low-Frequency Type III Bursts and Solar Energetic Particle Events

We analyzed the coronal mass ejections (CMEs), flares, and type 11 radio bursts associated with a set of six low frequency (<14 MHz) extended type III bursts from active region 10588. The durations were measured at 1 and 14 MHz using high resolution data from Wind/WAVES and were within the range (>15 min) normally used to define these bursts. All but one of the type III bursts was not associated with a type 11 burst in the metric or longer wavelength domains. The burst without type 11 burst also lacked a solar energetic particle (SEP) event at energies >25 MeV. The 1-MHz duration of the type III burst (28 min) is near the median value of type III durations found for gradual SEP events and ground level enhancement (GLE) events. Yet, there was no sign of SEP events. On the other hand, two other type III bursts from the same active region had similar duration but accompanied by WAVES type 11 bursts; these bursts were also accompanied by SEP events detected by SOHO/ERNE. The CMEs were of similar speeds and the flares are also of similar size and duration. This study suggests that the type III burst duration may not be a good indicator of an SEP event.

Gopalswamy, Nat↗

The localized origin of equatorial F region irregularity patches

An intensive study of nighttime irregularities of electron density in the equatorial ionosphere was performed in October 1976 by making 50-MHz radar backscatter measurements at Jicamarca, Peru, and scintillation measurements of 249-MHz transmissions from Les 9 at two ground stations (Ancon and Huancayo, both in Peru) as well as by aircraft flying in the vicinity of the stations. The 137-MHz scintillations from the orbiting Wideband satellite were also recorded at Huancayo. The results of such measurements made on October 16-17, 1976, are discussed in this report. We find that on this particular night a large-scale irregularity patch evolved first in the west, as was detected by the radar at Jicamarca, and drifted eastward to cause successive onsets of scintillation activity on propagation paths from Ancon and Huancayo. The observations indicate the east-west dimension of the large-scale structure to be 400 km drifting eastward at a speed of approximately 100 m/s, having a lifetime of several hours, and containing a hierarchy of irregularity scale sizes in the range of kilometers to meters causing both scintillations at 249 MHz and radar backscatter at 50 MHz.

Aarons, J.↗

An initial assessment of the performance achieved by the Seasat-1 radar altimeter

The results of an initial on-orbit engineering assessment of the performance achieved by the radar altimeter system flown on SEASAT-1 are presented. Additionally, the general design characteristics of this system are discussed and illustrations of altimeter data product are provided. The instrument consists of a 13.5 GHz monostatic radar system that tracks in range only using a one meter parabolic antenna pointed at the satellite nadir. Two of its unique features are a linear FM transmitter with 320 MHz bandwidth which yields a 3.125 nanosecond time delay resolution, and microprocessor implemented closed loop range tracking, automatic gain control (AGC), and real time estimation of significant wave height (SWH). Results presented show that the altimeter generally performed in accordance with its orginal performance requirments of measuring altitude to a precision of less the 10 cm RMS, significant wave height to an accuracy of + or - 0.5 m or 10%, whichever is greater, and ocean backscatter coefficient to an accuracy of + or - 1 db, all over an SWH range of 1 to 20 meters.

Townsend, W. F.↗

Wireless Capacitive Pressure Sensor With Directional RF Chip Antenna for High Temperature Environments

This paper presents the design, fabrication and characterization of a wireless capacitive pressure sensor with directional RF chip antenna that is envisioned for the health monitoring of aircraft engines operating in harsh environments. The sensing system is characterized from room temperature (25 C) to 300 C for a pressure range from 0 to 100 psi. The wireless pressure system consists of a Clapp-type oscillator design with a capacitive MEMS pressure sensor located in the LC-tank circuit of the oscillator. Therefore, as the pressure of the aircraft engine changes, so does the output resonant frequency of the sensing system. A chip antenna is integrated to transmit the system output to a receive antenna 10 m away.The design frequency of the wireless pressure sensor is 127 MHz and a 2 increase in resonant frequency over the temperature range of 25 to 300 C from 0 to 100 psi is observed. The phase noise is less than minus 30 dBcHz at the 1 kHz offset and decreases to less than minus 80 dBcHz at 10 kHz over the entire temperature range. The RF radiation patterns for two cuts of the wireless system have been measured and show that the system is highly directional and the MEMS pressure sensor is extremely linear from 0 to 100 psi.

Pressure sensor↗

The NANOGrav 12.5 Year Data Set: Monitoring Interstellar Scattering Delays

We extract interstellar scintillation parameters for pulsars observed by the NANOGrav radio pulsar timing program. Dynamic spectra for the observing epochs of each pulsar were used to obtain estimates of scintillation timescales, scintillation bandwidths, and the corresponding scattering delays using a stretching algorithm to account for frequency-dependent scaling. We were able to measure scintillation bandwidths for 28 pulsars at1500 MHz and 15 pulsars at 820 MHz. We examine scaling behavior for 17 pulsars and find power-law indices ranging from−0.7 to−3.6, though these may be biased shallow due to insufficient frequency resolution at lower frequencies. We were also able to measure scintillation timescales for six pulsars at 1500 MHz and seven pulsars at820 MHz. There is fair agreement between our scattering delay measurements and electron-density model predictions for most pulsars. We derive interstellar scattering-based transverse velocities assuming isotropic scattering and a scattering screen halfway between the pulsar and Earth. We also estimate the location of the scattering screens assuming proper motion and interstellar scattering-derived transverse velocities are equal. We find no correlations between variations in scattering delay and either variations in dispersion measure or flux density. For most pulsars for which scattering delays are measurable, we find that time-of-arrival uncertainties for a given epoch are larger than our scattering delay measurements, indicating that variable scattering delays are currently subdominant in our overall noise budget but are important for achieving precisions of tens of nanoseconds or less.

Jacob E Turner↗

Signal phase switches offer greater dynamic range

Circuit, placed in the signal path of a closed-loop receiver to modulate telemetered data in the 10-MHz spectrum, improves signal-to-noise ratio by 3 db in a communication receiver. The switch enables bandwidth reduction which reduces noise overload on the following stages, giving the system greater dynamic range.

Crow, R. B.↗

W/V-Band RF Propagation Experiment Design

The utilization of frequency spectrum for space-to-ground communications applications has generally progressed from the lowest available bands capable of supporting transmission through the atmosphere to the higher bands, which have required research and technological advancement to implement. As communications needs increase and the available spectrum in the microwave frequency bands (3 30 GHz) becomes congested globally, future systems will move into the millimeter wave (mm-wave) range (30 300 GHz). While current systems are operating in the Ka-band (20 30 GHz), systems planned for the coming decades will initiate operations in the Q-Band (33 50 GHz), V-Band (50 75 GHz) and W Band (75 110 GHz) of the spectrum. These bands offer extremely broadband capabilities (contiguous allocations of 500 MHz to 1GHz or more) and an uncluttered spectrum for a wide range of applications. NASA, DoD and commercial missions that can benefit from moving into the mm-wave bands include data relay and near-Earth data communications, unmanned aircraft communications, NASA science missions, and commercial broadcast/internet services, all able to be implemented via very small terminals. NASA Glenn Research Center has a long history of performing the inherently governmental function of opening new frequency spectrum by characterizing atmospheric effects on electromagnetic propagation and collaborating with the satellite communication industry to develop specific communications technologies for use by NASA and the nation. Along these lines, there are critical issues related to W/V-band propagation that need to be thoroughly understood before design of any operational system can commence. These issues arise primarily due to the limitations imposed on W/V-band signal propagation by the Earth s atmosphere, and to the fundamental lack of understanding of these effects with regards to proper system design and fade mitigation. In this paper, The GRC RF propagation team recommends measurements that are required to assure that the risk associated with the use of mm-wave is minimized. We develop first order beacon and transponder system payload requirements and beacon terminal requirements. We will suggest and discuss a possible hardware implementation for the space segment, as well for the ground segment. A discussion on a propagation measurement campaign for taking relevant statistical data is also included.

Acosta, Roberto J.↗

Science with the Square Kilometre Array

The Square Kilometre Array (SKA) is the centimeter- and meter-wavelength telescope for the 21st Century. Its Key Science Projects are (a) The end of the Dark Ages, involving searches for an H i signature and the first metalrich systems; (b) Testing theories of gravitation using an array of pulsars to search for gravitational waves and relativistic binaries to probe the strong-field regime; (c) Observations of H i to a redshift z ~ 2 from which to study the evolution of galaxies and dark energy. (d) Astrobiology including planetary formation within protoplanetary disks; and (c) The origin and evolution of cosmic magnetism, both within the Galaxy and in intergalactic space. The SKA will operate over the wavelength range of at least 1.2 cm to 4 m (70 MHz to 25 GHz), providing milliarcsecond resolution at the shortest wavelengths.

cosmic microwave↗

Optics-on-a-chip for ultrafast manipulation of 350-MHz hard x-ray pulses

Microelectromechanical systems (MEMS) are miniature devices integrated into a vast range of industrial and consumer applications. Optical MEMS are developed for dynamic spatiotemporal control in lightwave manipulation and communication as modulators, switches, multiplexers, spectrometer, etc. However, they have not been shown to function similarly in sub-nm wavelength regimes, namely, with hard x-rays, as high-brilliance pulsed x-rays have proven powerful for addressing challenges in time-domain science, from energy conversion to neurobiological control. While desirable temporal properties of x-ray pulses can be enhanced by optics, conventional x-ray optics are inherently massive in size, hence, never dynamic. We demonstrate highly ultrafast x-ray optics-on-a-chip based on MEMS capable of modulating hard x-ray pulses exceeding 350 MHz, 10 3 × higher than any other mechanical modulator, with a pulse purity >10 6 without compromising the spectral brilliance. Moreover, the timing characteristics of the devices can be tuned on-the-fly to deliver optimal pulse properties to create a host of dynamic x-ray instruments and applications, impossible with traditional optics of 10 9 × bulkier and more massive. The advent of the ultrafast optics-on-a-chip heralds a new paradigm of x-ray photonics, time-domain science, and accelerator diagnostics, especially at not only the future-generation light sources that offer coherent and high-frequency pulses but also lab-based facilities that normally do not offer timing structures.

42 ENGINEERING↗