Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Investigation of the Suppression of Edge Localized Modes by Resonant Magnetic Perturbations in NSTX/NSTX-U (Final Technical Report)

The purpose of the grant was to investigate the suppression of edge localized modes by resonant magnetic perturbations in both NSTX and NSTX-U. Unfortunately, the project quickly exhausted all of the relevant experimental data from NSTX. It was originally intended to use new data from NSTX-U, when it restarted. However, the considerable delay in the restart made this impossible. Hence, with the permission of DOE, the grant was pivoted toward a more general examination of the MHD stability of tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicting operational windows of ELMs suppression by resonant magnetic perturbations in the DIII-D and KSTAR tokamaks

A newly developed plasma response model, combining the nonlinear two-fluid MHD code TM1 and toroidal MHD code GPEC run in ideal mode, quantitatively predicts the narrow isolated q 95 windows (Δq 95 ~ 0.1) of ELM suppression by n = 1, 2 and 3 resonant magnetic perturbations (RMPs) in both DIII-D and KSTAR tokamaks across a wide range of plasma parameters. The key physics that unites both experimental observations and our simulations is the close alignment of essential resonant q-surfaces and the location of the top of the pedestal prior to an ELM. This alignment permits an applied RMP to produce field penetration due to the lower E × B rotation at the pedestal top rather than being screened. The model successfully predicts that narrow magnetic islands form when resonant field penetration occurs at the top of pedestal, and these islands are easily screened when q 95 moves off resonance, leading to very narrow windows of ELM suppression (typically Δq 95 ~ 0.1). Furthermore, the observed reduction in the pedestal height is also well captured by the calculated classical collisional transport across the island. We recover observed q 95 , β N and plasma shape dependence of ELM suppression due to the effect of magnetic islands on pedestal transport and Peeling-Ballooning- Mode (PBM) stability. Importantly, experiments do occasionally observe wide windows of ELM suppression (Δq 95 > 0.5). Our model reveals that at low pedestal-top density multiple islands open, leading to wide operational windows of ELM suppression consistent with experiment. The model indicates that wide q95 windows of ELM suppression can be achieved at substantially higher pedestal pressure with less confinement degradation in DIII-D by operating at higher toroidal mode number (n = 4) RMPs. As a result, this can have significant implications for the operation of the ITER ELM control coils for maintaining high confinement together with ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of a novel weak interaction between MUC1 and Src-SH3 using nuclear magnetic resonance spectroscopy

Highlights: Black-Right-Pointing-Pointer MUC1 binds the Src-SH3 domain potentially triggering Src dependent cell migration. Black-Right-Pointing-Pointer NMR Spectroscopy was used to monitor MUC1-CD and Src SH3 domain titrations. Black-Right-Pointing-Pointer MUC1-CD peptides bind with a low affinity (K{sub d} of 2-3 mM) to a non-canonical site. Black-Right-Pointing-Pointer Weak interactions may mediate dynamic processes like migration. Black-Right-Pointing-Pointer The MUC1-CD and Src-SH3 interaction may be a prime target to inhibit cell migration. -- Abstract: Breast cancer causes death through cancer cell migration and subsequent metastasis to distant organs. In vitro, the MUC1 mucin can mediate breast cancer cell migration by binding to intercellular adhesion molecule-1 (ICAM-1). This migration is dependent on MUC1 cytoplasmic domain (MUC1-CD) activation of the non-receptor tyrosine kinase, Src, possibly through competitive displacement of an inhibitory Src intramolecular SH3 binding. Therefore, we characterized the binding site and affinity of the MUC1-CD for Src-SH3 using multidimensional nuclear magnetic resonance (NMR) spectroscopy to monitor the titration of the {sup 15}N labeled Src-SH3 domain with synthetic native and mutant peptides of MUC1-CD. The results revealed that the dissociation constant (K{sub d}) for the interaction of the native MUC1-CD peptides and Src-SH3 domain was weak with a K{sub d} of 2-3 mM. Notably, the SH3 residues most perturbed upon peptide binding were located outside the usual hydrophobic binding cleft in a previously described alternate binding site on the Src-SH3, suggesting that MUC1-CD binds to a non-canonical site. The binding characteristics outlined here suggest that the interaction between Src-SH3 and MUC1-CD represents a novel weak electrostatic interaction of the type which is increasingly recognized as important in transient and dynamic protein complexes required for cell migration and signal transduction. As such, this study forms the foundation for the design of specific inhibitors of this interaction which may target breast cancer metastases with exquisite specificity.

60 APPLIED LIFE SCIENCES↗

Effect of energy and momentum conservation on fluid resonances for resonant magnetic perturbations in a tokamak

In this paper, the impact of momentum and energy conservation of the collision operator in the kinetic description for Resonant Magnetic Perturbations (RMPs) in a tokamak is studied. The particle conserving differential collision operator of Ornstein-Uhlenbeck type is supplemented with integral parts such that energy and momentum are conserved. The application to RMP penetration in a tokamak shows that energy conservation in the electron collision operator is important for the quantitative description of plasma shielding effects at the resonant surface. On the other hand, momentum conservation in the ion collision operator does not significantly change the results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Full suppression of runaway electron generation by the mode penetration of resonant magnetic perturbations during disruptions on J-TEXT

The avoidance and suppression of runaway electron (RE) generation during disruptions is of great importance for the safe operation of tokamaks. Massive gas injection is enacted to suppress the generation of REs, but the poor gas mixing efficiency and extremely high density required to suppress RE generation make the full RE suppression unreliable. The magnetic perturbations provide an alternative RE suppression during disruptions. The use of mode penetration induced by resonant magnetic perturbations (RMPs) to suppress RE generation has been investigated on the J-TEXT tokamak. For a sufficiently long mode penetration duration, robust runaway suppression has been reached during the disruptions. The m/n = 2/1 mode RMP with high amplitude excites large magnetic islands inside the plasma and leads to the large-scale destruction of magnetic surfaces during disruptions, which results in RE loss and runaway-free disruptions. The essential island width required for runaway suppression is estimated to be larger than 0.16 as the minor radius. This value might be slightly underestimated because of the misalignment between the electron cyclotron emission diagnostic and the island O-point. NIMROD simulations are used to investigate the effect of magnetic islands on RE generation during disruption, showing that the large magnetic islands have the ability to enhance RE seed loss during disruptions. RMP can excite large magnetic islands in the target plasma without tearing mode and might be a way to prevent RE generation during disruptions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond-laser–induced modifications in Co/Pt multilayers studied with tabletop resonant magnetic scattering

We characterize the magnetic domain structure of Co/Pt multilayer fi lms on length scales below one hundred nanometers using resonant magnetic scattering and magnetic force microscopy. The extreme ultraviolet light for the scattering experiment is created by a laser- based high-order harmonic generation source. After illumination with intense ultrashort laser pulses, we observe pronounced changes in the magnetic structure and morphology. Furthermore, this study points out the importance of a detailed analysis of the different laser-induced modifications of a magnetic thin fi lm that influence the scattering patterns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accelerating Dynamic Magnetic Resonance Imaging (MRI) for Lung Tumor Tracking Based on Low-Rank Decomposition in the Spatial–Temporal Domain: A Feasibility Study Based on Simulation and Preliminary Prospective Undersampled MRI

Purpose: To evaluate a low-rank decomposition method to reconstruct down-sampled k-space data for the purpose of tumor tracking. Methods and Materials: Seven retrospective lung cancer patients were included in the simulation study. The fully-sampled k-space data were first generated from existing 2-dimensional dynamic MR images and then down-sampled by 5 × -20 × before reconstruction using a Cartesian undersampling mask. Two methods, a low-rank decomposition method using combined dynamic MR images (k-t SLR based on sparsity and low-rank penalties) and a total variation (TV) method using individual dynamic MR frames, were used to reconstruct images. The tumor trajectories were derived on the basis of autosegmentation of the resultant images. To further test its feasibility, k-t SLR was used to reconstruct prospective data of a healthy subject. An undersampled balanced steady-state free precession sequence with the same undersampling mask was used to acquire the imaging data. Results: In the simulation study, higher imaging fidelity and low noise levels were achieved with the k-t SLR compared with TV. At 10 × undersampling, the k-t SLR method resulted in an average normalized mean square error <0.05, as opposed to 0.23 by using the TV reconstruction on individual frames. Less than 6% showed tracking errors >1 mm with 10 × down-sampling using k-t SLR, as opposed to 17% using TV. In the prospective study, k-t SLR substantially reduced reconstruction artifacts and retained anatomic details. Conclusions: Magnetic resonance reconstruction using k-t SLR on highly undersampled dynamic MR imaging data results in high image quality useful for tumor tracking. The k-t SLR was superior to TV by better exploiting the intrinsic anatomic coherence of the same patient. The feasibility of k-t SLR was demonstrated by prospective imaging acquisition and reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) versus endoscopic retrograde cholangiopancreatography (ERCP) in the pediatric population: a clinical effectiveness study

Purpose: To determine the diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) for detecting biliary and pancreatic abnormalities in a pediatric population, using endoscopic retrograde cholangiopancreatography (ERCP) as the reference standard. Materials and methods: Institutional review board approval with a waiver of informed consent was obtained for this retrospective investigation. Records from the Cincinnati Children’s Hospital Medical Center, Division of Gastroenterology and Department of Radiology were used to identify patients aged ≤ 18 years who had undergone both ERCP and MRCP within a 4-week interval between January 2013 and May 2017. Biliary and pancreatic duct findings were documented for each modality to determine the diagnostic performance of MRCP (with 95% confidence intervals), using ERCP as the reference standard. Results: 54 patients met inclusion criteria. Mean patient age at time of ERCP was 10.4 ± 4.9 years, and 25 (46%) were male. Mean interval between ERCP and MRCP was 11.2 ± 9.7 days. For detection of any abnormality (n = 99 ERCP findings), MRCP had a sensitivity of 76.8% (67.5–84.0%) and a positive predictive value (PPV) of 81.7% (72.7–88.3%). MRCP was 75.7% (59.9–86.6%) sensitive, with a PPV of 84.9% (69.1–93.4%) for biliary findings (n = 37) and 73.5% (59.7–83.8%) sensitive, with a PPV of 78.3% (64.4–87.7%) for pancreatic findings (n = 49). For pancreatobiliary abnormalities (n = 13), MRCP had a sensitivity of 92.3% (66.7–99.6%) and a PPV of 85.7% (60.1–97.5%). Conclusion: In clinical practice, MRCP is moderately sensitive for biliary and pancreatic abnormalities, with false-negative and false-positive examinations being relatively common.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Diffusion-Weighted Magnetic Resonance Imaging for Prediction and Early Assessment of Response to Neoadjuvant Radiochemotherapy in Rectal Cancer: Preliminary Results

Purpose: To evaluate diffusion-weighted magnetic resonance imaging (DWI) for response prediction before and response assessment during and early after preoperative radiochemotherapy (RCT) for locally advanced rectal cancer (LARC). Methods and Materials: Twenty patients receiving RCT for LARC underwent MRI including DWI before RCT, after 10-15 fractions and 1 to 2 weeks before surgery. Tumor volume and apparent diffusion coefficient (ADC; b-values: 0-1000 s/mm{sup 2}) were determined at all time points. Pretreatment tumor ADC and volume, tumor ADC change ( Increment ADC), and volume change ( Increment V) between pretreatment and follow-up examinations were compared with histopathologic findings after total mesorectal excision (pathologic complete response [pCR] vs. no pCR, ypT0-2 vs. ypT3-4, T-downstaging or not). The discriminatory capability of pretreatment tumor ADC and volume, Increment ADC, and Increment V for the detection of pCR was compared with receiver operating characteristics analysis. Results: Pretreatment ADC was significantly lower in patients with pCR compared with patients without (in mm{sup 2}/s: 0.94 {+-} 0.12 Multiplication-Sign 10{sup -3} vs. 1.19 {+-} 0.22 Multiplication-Sign 10{sup -3}, p = 0.003), yielding a sensitivity of 100% and specificity of 86% for detection of pCR. The volume reduction during and after RCT was significantly higher in patients with pCR compared with patients without (in %: {Delta}V{sub during}: -62 {+-} 16 vs. -33 {+-} 16, respectively, p = 0.015; and {Delta}V{sub post}: -86 {+-} 12 vs. -60 {+-} 21, p = 0.012), yielding a sensitivity of 83% and specificity of 71% for the {Delta}V{sub during} and, respectively, 83% and 86% for the {Delta}V{sub post}. The Increment ADC during ({Delta}ADC{sub during}) and after RCT ({Delta}ADC{sub post}) showed a significantly higher value in patients with pCR compared with patients without (in %: {Delta}ADC{sub during}: 72 {+-} 14 vs. 16 {+-} 12, p = 0.0006; and {Delta}ADC{sub post}: 88 {+-} 35 vs. 26 {+-} 19, p = 0.0011), yielding a sensitivity and specificity of 100% for the {Delta}ADC{sub during} and, respectively, 100% and 93% for the {Delta}ADC{sub post}. Conclusions: These initial findings indicate that DWI, using pretreatment ADC, {Delta}ADC{sub during}, and {Delta}ADC{sub post} may be useful for prediction and early assessment of pathologic response to preoperative RCT of LARC, with higher accuracy than volumetric measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of resonant magnetic perturbations on secondary structures in drift-wave turbulence

Recent experiments showed a decrease of long range correlations during the application of resonant magnetic perturbations (RMPs) [Y. Xu et al., Nucl. Fusion 51, 063020 (2011)]. This finding suggests that RMPs damp zonal flows. To elucidate the effect of the RMPs on zonal structures in drift wave turbulence, we construct a generalized Hasegawa-Wakatani model including RMP fields. The effect of the RMPs is to induce a linear coupling between the zonal electric field and the zonal density gradient, which drives the system to a state of electron radial force balance for large RMP amplitude. A predator-prey model coupling the primary drift wave dynamics to the zonal modes evolution is derived. This model has both turbulence drive and RMP amplitude as control parameters and predicts a novel type of transport bifurcation in the presence of RMPs. The novel regime has a power threshold which increases with RMP amplitude as {gamma}{sub c}{approx}[({delta}B{sub r}/B)]{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasi-linear toroidal simulations of resonant magnetic perturbations in eight ITER H-mode scenarios

Abstract Both linear and quasi-linear aspects of the plasma response to the resonant magnetic perturbation (RMP) field are numerically investigated for various H-mode scenarios in ITER, covering the pre-fusion power operation and the fusion power operation phases. Linear response computations for eight ITER scenarios, with varying plasma current and toroidal magnetic field, reveal that the best coil current phasing for controlling the type-I edge localized modes (ELMs) scales roughly linearly with the edge safety factor. The coil phasing is defined as the relative toroidal phase of the coil currents between different rows, for a given toroidal harmonic. Quasi-linear initial value simulation, which is the focus of the present study, shows that application of the n = 3 ( n is the toroidal mode number) RMP field has a minimum side effect on the plasma core momentum confinement but potentially a large effect on the global particle transport. Generally, the RMP field with the best (worst) coil phasing for ELM control produces the strongest (weakest) effect on the plasma edge flow and the overall density. This robustly holds for all eight ITER scenarios. Consequently, in order to minimize the RMP induced side effects while achieving ELM control (suppression) in ITER, a compromise is necessary in choosing the coil current configuration.

Physics↗

Quantitative correlational study of microbubble-enhanced ultrasound imaging and magnetic resonance imaging of glioma and early response to radiotherapy in a rat model

Purpose: Radiotherapy remains a major treatment method for malignant tumors. Magnetic resonance imaging (MRI) is the standard modality for assessing glioma treatment response in the clinic. Compared to MRI, ultrasound imaging is low-cost and portable and can be used during intraoperative procedures. The purpose of this study was to quantitatively compare contrast-enhanced ultrasound (CEUS) imaging and MRI of irradiated gliomas in rats and to determine which quantitative ultrasound imaging parameters can be used for the assessment of early response to radiation in glioma. Methods: Thirteen nude rats with U87 glioma were used. A small thinned skull window preparation was performed to facilitate ultrasound imaging and mimic intraoperative procedures. Both CEUS and MRI with structural, functional, and molecular imaging parameters were performed at preradiation and at 1 day and 4 days postradiation. Statistical analysis was performed to determine the correlations between MRI and CEUS parameters and the changes between pre- and postradiation imaging. Results: Area under the curve (AUC) in CEUS showed significant difference between preradiation and 4 days postradiation, along with four MRI parameters, T{sub 2}, apparent diffusion coefficient, cerebral blood flow, and amide proton transfer-weighted (APTw) (all p < 0.05). The APTw signal was correlated with three CEUS parameters, rise time (r = − 0.527, p < 0.05), time to peak (r = − 0.501, p < 0.05), and perfusion index (r = 458, p < 0.05). Cerebral blood flow was correlated with rise time (r = − 0.589, p < 0.01) and time to peak (r = − 0.543, p < 0.05). Conclusions: MRI can be used for the assessment of radiotherapy treatment response and CEUS with AUC as a new technique and can also be one of the assessment methods for early response to radiation in glioma.

60 APPLIED LIFE SCIENCES↗

Influence of resonant magnetic perturbations and induced islands on plasma rotations and turbulence properties in the J-TEXT tokamak

Dedicated experiments have been carried out at the J-TEXT tokamak for investigating plasma responses to the externally applied resonant magnetic perturbation (RMP) field with various RMP currents under four different toroidal phases. After its penetration, the dominant component of the RMP resonated at q =2 surface and excited an m/n =2/1 magnetic island, which rotated poloidally when changing the toroidal phase of the RMP. The experimental results show significant influence of the RMP on plasma toroidal and perpendicular rotations, density fluctuations and geodesic acoustic modes (GAMs) as well as nonlinear interaction of ambient turbulence. Whereas the plasma rotations do not show big difference at the RMP-induced island O- and X-point, the turbulence level is substantially lower at the island O-point due to reduced local temperature gradient. The GAM zonal flows outside the island area are profoundly affected by the RMP in various RMP phases. Furthermore, it was found that under certain RMP currents the nonlinear coupling of ambient turbulence was considerably enhanced, no matter of at the island O- or X-point. The results suggest a possible controlling role of the RMP in regulating the nonlinear interplay of electrostatic turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonant features of energy and particle transport during application of resonant magnetic perturbation fields at TEXTOR and DIII-D

In this paper, results of a direct comparison of TEXTOR and DIII-D experiments with resonant magnetic perturbation (RMP) fields are presented. This comparison of resistive L-mode plasmas at TEXTOR with highly conductive H-mode plasmas at DIII-D is useful to identify generic physics mechanisms during application of RMP fields with a strong field line pitch angle alignment in the plasma edge. A reduction in the pedestal electron pressure p(e) with increasing extension of the vacuum modelled stochastic layer and p(e) recovery with decreasing layer width is found caused by a q(95) resonant reduction in the edge (0.8 < Psi(N) < 0.95) electron temperature T-e(q(95)) on both devices. For RMP edge-localized mode (ELM) suppressed H-mode plasmas at DIII-D, the gradients del T-e and nominal values of T-e are reduced in this edge region while increasing in the pedestal (0.95 < Psi(N) < 1.0) with RMP field applied and both are highly dependent on q(95). In contrast, an increase in the central ion temperature with strong steepening of the ion temperature profile at mid-radius is found-again being highly dependent on q(95). However, these resonant thermal transport effects are only seen in high triangularity plasmas revealing a strong shape dependence of the thermal transport. In contrast to the highly q(95) dependent thermal transport features, the reduction of n(e)-known as density pump out-shows a much weaker dependence on q(95). We show the potential to reduce the RMP induced particle pump out by fine tuning of the RMP spectral properties. At low resonant field amplitudes enhanced particle confinement is seen in high-field side limited L-mode discharges on both devices while higher resonant field amplitudes yield particle pumps out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

True Local Recurrence Rate in the Conserved Breast After Magnetic Resonance Imaging-Targeted Radiotherapy

Purpose: Better accuracy of local radiotherapy may substantially improve local control and thus long-term breast cancer survival. Magnetic resonance imaging (MRI) has high resolution and sensitivity in breast tissue and may depict the tumor bed more accurately than conventional planning techniques. A postoperative complex (POCx) comprises all visible changes thought to be related to surgery within the breast and acts as a surrogate for the tumor bed. This study reports on local recurrence rates after MRI-assisted radiotherapy planning to ensure adequate coverage of the POCx. Methods and Materials: Simple opposed tangential fields were defined by surface anatomy in the conventional manner in 221 consecutive patients. After MRI, fields were modified by a single radiation oncologist to ensure encompassment of the POCx with a 10-mm margin. Genetic analysis was performed on all local relapses (LRs) to distinguish true recurrences (TRs) from new primaries (NPs). Results: This was a high risk cohort at 5 years: only 9.5% were classified as low risk (St Gallen): 43.4% were Grade 3 and 19.9% had surgical margins <1 mm; 62.4% of patients received boosts. Adjustments of standard field margins were required in 69%. After a median follow-up of 5 years, there were 3 LRs (1.3%) as the site of first relapse in 221 patients, comprising two TRs (0.9%) and one NP (0.4%). Conclusions: Accurate targeting of the true tumor bed is critical. MRI may better define the tumor bed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Tumor Radioresponsiveness and Metastatic Potential by Dynamic Contrast-Enhanced Magnetic Resonance Imaging

Purpose: It has been suggested that gadolinium diethylene-triamine penta-acetic acid (Gd-DTPA)-based dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) may provide clinically useful biomarkers for personalized cancer treatment. In this preclinical study, we investigated the potential of DCE-MRI as a noninvasive method for assessing the radioresponsiveness and metastatic potential of tumors. Methods and Materials: R-18 melanoma xenografts growing in BALB/c nu/nu mice were used as experimental tumor models. Fifty tumors were subjected to DCE-MRI, and parametric images of K{sup trans} (the volume transfer constant of Gd-DTPA) and v{sub e} (the fractional distribution volume of Gd-DTPA) were produced by pharmacokinetic analysis of the DCE-MRI series. The tumors were irradiated after the DCE-MRI, either with a single dose of 10 Gy for detection of radiobiological hypoxia (30 tumors) or with five fractions of 4 Gy in 48 h for assessment of radioresponsiveness (20 tumors). The host mice were then euthanized and examined for lymph node metastases, and the primary tumors were resected for measurement of cell survival in vitro. Results: Tumors with hypoxic cells showed significantly lower K{sup trans} values than tumors without significant hypoxia (p < 0.0001, n = 30), and K{sup trans} decreased with increasing cell surviving fraction for tumors given fractionated radiation treatment (p < 0.0001, n = 20). Tumors in metastasis-positive mice had significantly lower K{sup trans} values than tumors in metastasis-negative mice (p < 0.0001, n = 50). Significant correlations between v{sub e} and tumor hypoxia, radioresponsiveness, or metastatic potential could not be detected. Conclusions: R-18 tumors with low K{sup trans} values are likely to be resistant to radiation treatment and have a high probability of developing lymph node metastases. The general validity of these observations should be investigated further by studying preclinical tumor models with biological properties different from those of the R-18 tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Alterations in Mouse Brain Development Characterized by Magnetic Resonance Imaging

Purpose: The purpose of this study was to identify regions of altered development in the mouse brain after cranial irradiation using longitudinal magnetic resonance imaging (MRI). Methods and Materials: Female C57Bl/6 mice received a whole-brain radiation dose of 7 Gy at an infant-equivalent age of 2.5 weeks. MRI was performed before irradiation and at 3 time points following irradiation. Deformation-based morphometry was used to quantify volume and growth rate changes following irradiation. Results: Widespread developmental deficits were observed in both white and gray matter regions following irradiation. Most of the affected brain regions suffered an initial volume deficit followed by growth at a normal rate, remaining smaller in irradiated brains compared with controls at all time points examined. The one exception was the olfactory bulb, which in addition to an early volume deficit, grew at a slower rate thereafter, resulting in a progressive volume deficit relative to controls. Immunohistochemical assessment revealed demyelination in white matter and loss of neural progenitor cells in the subgranular zone of the dentate gyrus and subventricular zone. Conclusions: MRI can detect regional differences in neuroanatomy and brain growth after whole-brain irradiation in the developing mouse. Developmental deficits in neuroanatomy persist, or even progress, and may serve as useful markers of late effects in mouse models. The high-throughput evaluation of brain development enabled by these methods may allow testing of strategies to mitigate late effects after pediatric cranial irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗