Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

An Investigation into the Electromagnetic Interactions between a Superconducting Torus and Solenoid for the Jefferson Lab 12 GeV Upgrade

The Jefferson Lab 12 GeV Upgrade in Hall B will need CLAS12 detector that requires two superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a Toroidal configuration (Torus) and the second is an actively shielded solenoidal magnet (Solenoid). Both the torus and solenoid are located in close proximity to one another and are surrounded by sensitive detectors. This paper investigates the electromagnetic interactions between the two systems during normal operation as well as during various fault scenarios as part of a Risk Assessment and Mitigation (RAM).

Torus, actively shielded, Solenoid, SSC-NbTi,Ruthe↗

Spin-orbit coupling induced robust spin-Seebeck effect and pure thermal spin currents in achiral molecule systems

Spin-Seebeck effect (SSE) is an effective route to realize pure spin current by using spin-polarized electrons or spin-wave transport in magnetic systems. In this work we propose a route, i.e., by using spin-orbit coupling (SOC), to achieve robust SSE characterized by pure thermal spin current. The material examples are constructed on achiral nanotubes, and the theoretical results reveal that (i) as temperature gradient is applied along the nanotubes, thermal spin-up and spin-down currents with opposite flow directions are produced without any accompanying charge current, (ii) the SSE is robust against decoherence and nonuniform interchain SOC, (iii) the thermal spin currents display a multioscillation feature with increasing device temperatures, supporting their potential device applications in thermal spin-current multiswitcher, and (vi) strain engineering in the radical direction of nanotubes is an effective way to improve SSE and to control pure thermal spin current. These inspiring spin transport behaviors in achiral molecular systems put forward a mechanism to realize the robust SSE characterized by pure spin current and develop the research field of spin-orbito-caloritronics, which focuses on the interplay of electrons’ spin and orbital degrees of freedom in the presence of temperature gradient.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of magnetic parameters in La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/SrTiO{sub 3} thin films using EMCD

It is well known that the magnetic state of the La{sub 0.7}Sr{sub 0.3}MnO{sub 3} (LSMO) thin-film heterostructure is strongly correlated with the lattice, spin, orbital, and charge states, since these influence the electric and magnetic transport properties even on the unit-cell level. Therefore, understanding the material's magnetic properties on the nanoscale is important for the development of novel applications. The recently developed electron magnetic-circular dichroism (EMCD) technique allows the determination of atomic site-specific magnetic information via the use of transmitted electrons; however, its sensitivity is not high enough to quantitatively acquire magnetic information in many weak magnetism systems. Here, we utilized a dynamical diffraction-effect assisted EMCD technique to quantitatively determine the spin and orbital magnetic moment of LSMO/SrTiO{sub 3} thin films on the nanometer scale using a transmission electron microscope. Further, data processing was optimized to enhance the intensity of the EMCD signals for manganese, which have very weak magnetism at room temperature. High signal-to-noise ratio and accurate quantitative magnetic measurement are eventually achieved. Finally, the spin magnetic moments (0.73 ± 0.26 μ{sub B}) are derived, and we also limited the ratio of the orbital to spin magnetic moment within an interval of (−0.03, 0.01). Our results not only present the nanoscale magnetic parameters of LSMO/SrTiO{sub 3}, but also demonstrate how the measurement limit of the spin (or orbital) magnetic moment can be achieved, which is via the developed dynamical diffraction effect assisted EMCD technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FINE MAGNETIC STRUCTURE AND ORIGIN OF COUNTER-STREAMING MASS FLOWS IN A QUIESCENT SOLAR PROMINENCE

We present high-resolution observations of a quiescent solar prominence that consists of a vertical and a horizontal foot encircled by an overlying spine and has ubiquitous counter-streaming mass flows. While the horizontal foot and the spine were connected to the solar surface, the vertical foot was suspended above the solar surface and was supported by a semicircular bubble structure. The bubble first collapsed, then reformed at a similar height, and finally started to oscillate for a long time. We find that the collapse and oscillation of the bubble boundary were tightly associated with a flare-like feature located at the bottom of the bubble. Based on the observational results, we propose that the prominence should be composed of an overlying horizontal spine encircling a low-lying horizontal and vertical foot, in which the horizontal foot consists of shorter field lines running partially along the spine and has ends connected to the solar surface, while the vertical foot consists of piling-up dips due to the sagging of the spine fields and is supported by a bipolar magnetic system formed by parasitic polarities (i.e., the bubble). The upflows in the vertical foot were possibly caused by the magnetic reconnection at the separator between the bubble and the overlying dips, which intruded into the persistent downflow field and formed the picture of counter-streaming mass flows. In addition, the counter-streaming flows in the horizontal foot were possibly caused by the imbalanced pressure at the both ends.

79 ASTRONOMY AND ASTROPHYSICS↗

Charge-magnetic interference resonant scattering studies of ferromagnetic crystals and thin films

The element- and site-specificity of X-ray resonant magnetic scattering (XRMS) makes it an ideal tool for furthering our understanding of complex magnetic systems. In the hard X-rays, XRMS is readily applied to most antiferromagnets where the relatively weak resonant magnetic scattering (10 -2 –10 -6 I c ) is separated in reciprocal space from the stronger, Bragg charge scattered intensity, I c . In ferro(ferri)magnetic materials, however, such separation does not occur and measurements of resonant magnetic scattering in the presence of strong charge scattering are quite challenging. We discuss the use of charge-magnetic interference resonant scattering for studies of ferromagnetic (FM) crystals and layered films. We review the challenges and opportunities afforded by this approach, particularly when using circularly polarized X-rays. Here we illustrate current capabilities at the Advanced Photon Source with studies aimed at probing site-specific magnetism in ferromagnetic crystals, and interfacial magnetism in films.

36 MATERIALS SCIENCE↗

Dynamic Optimization of Switched-Reluctance Motors

A design algorithm is proposed for switched-reluctance motors used in manufacturing systems. The algorithm includes an optimization procedure and is based on the Monte Carlo method. In optimization of the magnetic system, it is advisable to take account of the motor’s operating conditions. The results of optimization are compared. Recommendations are made regarding the selection of the tooth-zone dimensions.

42 ENGINEERING↗

Tolerance Studies of the Mu2e Solenoid System

The muon-to-electron conversion experiment at Fermilab is designed to explore charged lepton flavor violation. It is composed of three large superconducting solenoids, namely, the production solenoid, the transport solenoid, and the detector solenoid. Each subsystem has a set of field requirements. Tolerance sensitivity studies of the magnet system were performed with the objective of demonstrating that the present magnet design meets all the field requirements. Systematic and random errors were considered on the position and alignment of the coils. The study helps to identify the critical sources of errors and which are translated to coil manufacturing and mechanical support tolerances.

43 PARTICLE ACCELERATORS↗

Energy and momentum conservation in spin transfer

We utilize simulations of spin-polarized electron scattering by a chain of localized quantum spins to show that energy and linear momentum conservation laws impose strong constraints on the properties of magnetic excitations induced by spin transfer. In turn, orbital and spin dynamics of conduction electrons depends on the dynamical characteristics of the local spins. Furthermore, our results suggest the possibility to achieve precise control of spin-transfer-driven magnetization dynamics by tailoring the spectral characteristics of the magnetic systems and of the driving electrons.

36 MATERIALS SCIENCE↗

Out-of-Plane Magnetic Anisotropy Engineered via Band Distortion in Two-Dimensional Materials

We unveil the connection between magnetic anisotropy and band structures in Γ-specialized In 2 Se 3 /Fe 3 GeTe 2 heterostructure, through first-principles calculations. A significant band distortion occurs near the Γ point with a formed valley. As the band-distortion-caused valley moves relative to the quasivalence band maximum, the magnetic anisotropy switches between in-plane and out-of-plane magnetic anisotropy. Such a rule applies to either the strained or polarization-switched In 2 Se 3 /Fe 3 GeTe 2 heterostructure. Furthermore, these findings demonstrate the feasibility of predicting the magnetic anisotropy by band structure modification in two-dimensional magnetic systems.

2-dimensional systems↗

Symmetry-dependent ultrafast manipulation of nanoscale magnetic domains

Symmetry is a powerful concept in physics, but its applicability to far-from-equilibrium states is still being understood. Recent attention has focused on how far-from-equilibrium states lead to spontaneous symmetry breaking. Conversely, ultrafast optical pumping can be used to drastically change the energy landscape and quench the magnetic order parameter in magnetic systems. Here, we find a distinct symmetry-dependent ultrafast behaviour by use of ultrafast x-ray scattering from magnetic patterns with varying degrees of isotropic and anisotropic symmetry. After pumping with an optical laser, the scattered intensity reveals a radial shift exclusive to the isotropic component and exhibits a faster recovery time from quenching for the anisotropic component. These features arise even when both symmetry components are concurrently measured, suggesting a correspondence between the excitation and the magnetic order symmetry. Our results underline the importance of symmetry as a critical variable to manipulate the magnetic order in the ultrafast regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetoelastics of a spin liquid : x-ray diffraction studies of Tb{sub 2}Ti{sub 2}O{sub 7} in pulsed magnetic fields.

We report high resolution single crystal x-ray diffraction measurements of the frustrated pyrochlore magnet Tb{sub 2}Ti{sub 2}O{sub 7}, collected using a novel low temperature pulsed magnet system. This instrument allows characterization of structural degrees of freedom to temperatures as low as 4.4 K, and in applied magnetic fields as large as 30 T. We show that Tb{sub 2}Ti{sub 2}O{sub 7} manifests intriguing structural effects under the application of magnetic fields, including strongly anisotropic giant magnetostriction, a restoration of perfect pyrochlore symmetry in low magnetic fields, and ultimately a structural phase transition in high magnetic fields. It is suggested that the magnetoelastic coupling thus revealed plays a significant role in the spin liquid physics of Tb{sub 2}Ti{sub 2}O{sub 7} at low temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interfacial tuning of chiral magnetic interactions for large topological Hall effects in LaMnO 3 /SrIrO 3 heterostructures

Chiral interactions in magnetic systems can give rise to rich physics manifested, for example, as nontrivial spin textures. The foremost interaction responsible for chiral magnetism is the Dzyaloshinskii-Moriya interaction (DMI), resulting from inversion symmetry breaking in the presence of strong spin-orbit coupling. However, the atomistic origin of DMIs and their relationship to emergent electrodynamic phenomena, such as topological Hall effect (THE), remain unclear. Here, we investigate the role of interfacial DMIs in 3 d –5 d transition metal-oxide-based LaMnO 3 /SrIrO 3 superlattices on THE from a chiral spin texture. By additively engineering the interfacial inversion symmetry with atomic-scale precision, we directly link the competition between interfacial collinear ferromagnetic interactions and DMIs to an enhanced THE. The ability to control the DMI and resulting THE points to a pathway for harnessing interfacial structures to maximize the density of chiral spin textures useful for developing high-density information storage and quantum magnets for quantum information science.

36 MATERIALS SCIENCE↗

Magnetic Measurement With Single Stretched Wire Method on SuperKEKB Final Focus Quadrupoles

Superconducting-final-focus-quadrupole magnet system (QCS) were installed on an interaction region (IR) of SuperKEKB on Feb. 2017. The QCS consists of eight quadrupole magnets and four compensation solenoids; these magnets are contained in the two cryostats and are installed into Belle II detector which generates a solenoid field of 1.5 T. We determined the quadrupole centers with respect to accelerator beam lines with a single stretched wire (SSW) method. Here the results of the magnetic measurement with SSW are presented.

43 PARTICLE ACCELERATORS↗

Bead-based microfluidic immunoassay for diagnosis of Johne's disease

Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types of SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.

60 APPLIED LIFE SCIENCES↗

Prospects for pilot plants based on the tokamak, spherical tokamak and stellarator.

A potentially attractive next-step towards fusion commercialization is a pilot plant, i.e. a device ultimately capable of small net electricity production in as compact a facility as possible and in a configuration scalable to a full-size power plant. A key capability for a pilot-plant programme is the production of high neutron fluence enabling fusion nuclear science and technology (FNST) research. It is found that for physics and technology assumptions between those assumed for ITER and nth-of-a-kind fusion power plant, it is possible to provide FNST-relevant neutron wall loading in pilot devices. Thus, it may be possible to utilize a single facility to perform FNST research utilizing reactor-relevant plasma, blanket, coil and auxiliary systems and maintenance schemes while also targeting net electricity production. In this paper three configurations for a pilot plant are considered: the advanced tokamak, spherical tokamak and compact stellarator. A range of configuration issues is considered including: radial build and blanket design, magnet systems, maintenance schemes, tritium consumption and self-sufficiency, physics scenarios and a brief assessment of research needs for the configurations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SUPERCONDUCTING RING CYCLOTRON FOR RIKEN RI BEAM FACTORY IN JAPAN

Since 1997, RIKEN Nishina Center has been constructing the Radioactive Isotope Beam Factory (RIBF) and succeeded in beam commissioning of its accelerator complex at the end of 2006. The world's first superconducting ring cyclotron (SRC) is the final booster in the RIBF accelerator complex which is able to accelerate all-element heavy ions to a speed of about 70% of the velocity of light. The ring cyclotron consists of 6 major superconducting sector magnets with a maximum field of 3.8 T. The total stored energy is 235 MJ, and its overall sizes are 19 m diameter, 8 m height and 8,300 tons. The magnet system assembly was completed in August 2005, and successfully reached the maximum field in November 2005. The first beam was extracted at the end of 2006 and the first uranium beam was extracted in March 2007. However operation of the helium refrigerator was not satisfactory although the commissioning of SRC was successful. Operation was stopped every two month due to degradation of its cooling power. In February 2008 the reason of the degradation was revealed to be oil contamination. Operation of the cryogenic system was restarted from August 2008 after hard task to clean up the helium refrigerator and to add oil separators to the compressor. After restoration long-term steady operation to keep the magnet superconducting continued for about 8 months with no sign of degradation of cooling capacity.

43 PARTICLE ACCELERATORS↗

Pulsed spallation neutron spectroscopy of low dimensional magnets: past, present, and future

The early 1990s saw the first useful application of pulsed neutron spectroscopy to the study of excitations in low dimensional magnetic systems, with Roger Cowley as a key participant in important early experiments. Since that time the technique has blossomed as a powerful tool utilizing vastly improved neutron instrumentation coupled with more powerful pulsed sources. In this work, we review representative experiments illustrating some of the fascinating physics that has been revealed in quasi-one and two dimensional systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗