Use of a commercially available nucleating agent to control the morphological development of solution-processed small molecule bulk heterojunction organic solar cells
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We report here the coordination chemistry of the tripodal tris[2-amido(2-pyridyl)ethyl]amine ligand, L, with thorium(IV) and uranium(IV). Using a salt-metathesis strategy from the potassium salt of this ligand, K 3 L, new actinide complexes were isolated, namely the dimeric thorium complex [ThCl(L)] 2 (1) and the monomeric uranium complex UI(THF)(L) (2); under different crystallisation conditions, the dimeric uranium complex is also isolated, [UI(L)] 2 (2-dimer). With the aim of studying electronic phenomena such as magnetic exchange between two actinide ions, we have synthesised the first examples of dinuclear, quinoid-bridged actinide complexes from dianionic 2,5-bis[2,6-(diisopropyl)anilide]-1,4-benzoquinone (Q Dipp ) and 2,5-bis[2-(methoxy)anilide]-1,4-benzoquinone (Q OMe ) ligands. The resulting complexes are [Th(L)] 2 Q Dipp (3), [Th(THF)(L)] 2 Q OMe (5) and [U(L)] 2 Q OMe (6). The targeted [U(L)] 2 Q Dipp complex (4) could not be isolated. All isolated complexes have been characterised by spectroscopic methods and X-ray crystallography. The uranium(IV) complexes 2-dimer and 6 have been studied by SQUID magnetometry but indicate that there is negligible magnetic exchange between the two uranium(IV) ions. The reduced form of 6, [K(18-c-6)][6 - ] is unstable and highly sensitive, but X-ray crystallography indicates that it is a novel U IV U IV complex bridged by a quinoid-radical.
Vanadium is the main competitor for uranium extraction from seawater, and V( iv ) comprises a minor but important portion of this. V( iv ) undergoes redox reactions with oximes and amidoxime ligands under seawater-relevant conditions, leading to V( v ) complexes and loss of oxime functional groups.
Crystals of Cu 2 (pacman) inflate on taking up neon at 46 000 atm through a switch in the ligand conformation.
The catalytic properties of zeolites are intimately linked to the distribution and relative positions of Al atoms and defects in the pore network. However, characterizing this distribution is challenging, in particular when different local Al arrangements are considered. In this contribution we use a combination of first principles calculations and experimental measurements to develop a model for the Al-distribution in protonated SSZ-13. We furthermore apply this model to understand trends in OH-IR, 27 Al-NMR and 29 Si-NMR spectra. We use a Boltzmann distribution to predict the proton position for a given local Al configuration and demonstrate that for each configuration several H positions are occupied. Therefore a multi-peak spectrum in OH-IR vibrational spectroscopy is observed for all Al configurations, which is in line with experimentally measured spectra for zeolites at different Si/Al ratios. From NMR spectroscopy we find that the proton position leads to significant shifts in 27 Al-NMR and 29 Si-NMR spectra due to the modification of the local strain, which is lost when a uniform background charge is introduced. These findings are supported by experimental measurements. Finally we discuss the shortcomings of the presented model in terms of unit cell size and the impact of adjacent unit cells.
Aqueous solutions of polyethylene oxide–polypropylene oxide–polyethylene oxide (PEO–PPO–PEO) copolymers form micelles and cubic lattices as their temperature is raised. The presence of added solutes within the dispersions can also affect the kinetics of structure formation. In this work, we investigate the structures formed in the amphiphiles P104, P105, and F108 solutions at 31% mass per v both neat and co-formulated with the drug cisplatin (0.02% to 0.1% mass per v) using small-angle X-ray scattering. P104 formed BCC colloidal crystals while P105 and F108 formed FCC structures. Cisplatin had a minor influence of the formation and stability of the crystals during these thermal excursions. The largest interaction between the amphiphiles and cisplatin was P104 where there was a 2% reduction in the BCC lattice parameter of P104 as cisplatin loading rose to 0.1% at 28 °C. The F108 unit cell swelled ~2% upon cisplatin loading of 0.1%. A progressive evolution and breakdown of these structures was noted as the temperature rose from 10 °C to 35 °C. For the different amphiphiles, crystal thermal expansion coefficients of ~1 × 10 –2 °C –1 were determined in neat and loaded amphiphiles with cisplatin and all the crystals swelled with increasing temperature.
A U IV /U IV “Pacman” complex exhibits facile oxo-ligand functionalisation and substitution reactivity, owing to a bridging catecholate ligand that enhances the μ-oxo nucleophilicity and stabilises the resulting products.
Unfunctionalized vinyl-addition polynorbornene (VAPNB) possesses many outstanding properties such as high thermal, chemical, and oxidative stability. These features make VAPNB a promising candidate for many engineering applications. However, VAPNB has a small service window between its glass transition temperature (T g ) and decomposition temperature (T d ), and it cannot be readily processed in a melt state. In this work, we demonstrate that the service window of VAPNBs can be tailored through the use of norbornene monomers bearing alkyl, aryl, and aryl ether substituents. The vinyl addition homopolymerization and copolymerization of these functionalized norbornyl-based monomers yielded VAPNBs with high T' g s (>150 °C) and large service windows (T d –T g > 100 °C), which are comparable to other commercial engineering thermoplastics. To further establish the feasibility of melt processing, a functionalized VAPNB material with T g = 209 °C and a service window of 170 °C was successfully extruded and molded into bars. Subsequent characterization of the bars by dynamic mechanical analysis (DMA), nuclear magnetic resonance spectroscopy (NMR), and gel permeation chromatography (GPC) revealed only minor signs of polymer degradation. Furthermore, these studies suggest that substituted VAPNBs could be developed into a new class of engineering thermoplastics that is compatible with workhorse melt processing techniques such as extrusion and injection molding, as well as emerging techniques such as extrusion-based 3D printing.
Symmetric Ni( i ) agostic complexes reveal an unusual mode of bonding that is dominated by direct carbon-to-metal charge transfer.
Data acquisition systems for high energy physics experiments readout terabytes of data per second from a large number of electronic components. They are thus inherently distributed systems and require fast online data selection, otherwise requirements for permanent storage would be enormous. Still, incoming data need to be buffered while waiting for this selection to happen. Each minute of an experiment can produce hundreds of terabytes that cannot be lost before a selection decision is made. In this context, we present the design of DAQDB (Data Acquisition Database) - a distributed key-value store for high-bandwidth, generic data storage in event-driven systems. DAQDB offers not only high-capacity and low-latency buffer for fast data selection, but also opens a new approach in high-bandwidth data acquisition by decoupling the lifetime of the data analysis processes from the changing event rate due to the duty cycle of the data source. This is achievable by the option to extend its capacity even up to hundreds of petabytes to store hours of an experiment’s data. Our initial performance evaluation shows that DAQDB is a promising alternative to generic database solutions for the high luminosity upgrades of the LHC at CERN.
Data acquisition systems are a key component for successful data taking in any experiment. The DAQ is a complex distributed computing system and coordinates all operations, from the data selection stage of interesting events to storage elements. For the High Luminosity upgrade of the Large Hadron Collider, the experiments at CERN need to meet challenging requirements to record data with a much higher occupancy in the detectors. The DAQ system will receive and deliver data with a significantly increased trigger rate, one million events per second, and capacity, terabytes of data per second. An effective way to meet these requirements is to decouple real-time data acquisition from event selection. Data fragments can be temporarily stored in a large distributed key-value store. Fragments belonging to the same event can be then queried on demand, by the data selection processes. Implementing such a model relies on a proper combination of emerging technologies, such as persistent memory, NVMe SSDs, scalable networking, and data structures, as well as high performance, scalable software. In this paper, we present DAQDB (Data Acquisition Database) — an open source implementation of this design that was presented earlier, with an extensive evaluation of this approach, from the single node to the distributed performance. Furthermore, we complement our study with a description of the challenges faced and the lessons learned while integrating DAQDB with the existing software framework of the ATLAS experiment.
The Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) Camera is scheduled to start taking data in the summer of 2025. The Data Release Production will run the LSST Science Pipe software at data facilities in the US, France and the UK. The LSST Science Pipeline consists of complex directed acyclic graphs (DAGs) of tasks. Rubin will use the Production and Distributed Analysis (PanDA) workflow and workload management system to orchestrate this complex workflow and the distribution of workloads to the data facilities. When run end-to-end by a team of data production staff, this processing (the Science Pipelines, distributed by the workflow and workload management system) is referred to as a 'campaign'. This paper describes the central services and data facility specific services that support this multi-site data process model, including the service deployment infrastructure, the workload and workflow system, the Campaign Management tools, and connection to Rubin Data Management. This paper will also mention the experience of processing the Rubin Commissioning Camera data. All these are part of the effort to scale up the processing capabilities for the expected very large data volume from the LSST Camera.
Intersecting stacks of supersymmetric fractional branes on the Z{sub 6}{sup '} orientifold may be used to construct the supersymmetric Standard Model. We construct a four-stack model, which has the matter spectrum of the supersymmetric Standard Model, including a single pair of Higgs doublets, plus three neutrino-singlet states. However, the gauge group is SU(3){sub colour}xSU(2){sub L}xU(1){sub Y}xU(1), and there is no overall cancellation of Ramond-Ramond tadpoles.
Numerous applications exist for CW linear accelerators with final energies in the 0.5 to 4.0 MeV proton energy range. Typical proton current at the linac output energy is 20 mA. An important subsystem for the accelerator facility is a reliable dc mode proton injector. We present here design and laboratory results for a dc, 25-keV, 30-mA proton injector. The proton source is a 2.45-GHz microwave hydrogen ion source which operates with an 875-G axial magnetic field. Low emittance, high proton fraction (>85%), beams have been demonstrated from this source. The injector uses a novel dual-solenoid magnet for matching the injector beam into a radio frequency quadrupole (RFQ) linear accelerator. Recently, a dc ion-source development program has given up to 30 mA beam current. The dual solenoid is a compact and simple design utilizing tape-wound, edge-cooled coils. The low-energy beam transport design as well as 25-keV beam matching calculations to an RFQ will also be presented.
Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.
In this work, we use X-ray Excited Luminescence Microscopy to investigate the elemental and layer resolved magnetic reversal in an interlayer exchange coupled (IEC) epitaxial Fe/Cr wedge/Co heterostructure. The transition from strongly coupled parallel Co-Fe reversal for Cr thickness t(Cr) < 0.34 nm to weakly coupled layer independent reversal for t(Cr) > 1.5 nm is punctuated at 0.34 < t(Cr) < 1.5 nm by a combination of IEC guided domain wall motion and stationary zig zag domain walls. Domain walls nucleated at switching field minima are guided by IEC spatial gradients and collapse at switching field maxima.
A previous publication [P. D. McChesney, “Multi-plate interceptive electron beam energy diagnostic—Theoretical design,” AIP Adv. (submitted)] reported a new interceptive electron beam kinetic energy measurement technique based on the beam penetration depth within a stack of conductive plates and gave results on the theoretical design of such a device. This paper expands on this and gives further results on the actual implementation of the diagnostic. The device geometry and measurement electronics system are described in detail. A prototype version of the multi-plate diagnostic was fabricated and tested using an electron linear accelerator at the Idaho Accelerator Center (IAC). A high-precision magnetic spectrometer system was designed and built for the purpose of validating the multi-plate diagnostic’s energy measurement capabilities. It was found that the diagnostic provides electron beam energy estimates that are accurate to better than the 10% level.