Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integral Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Distribution of Neutrons in a Cold Lucite Moderator

A series of experiments was performed in 2010 to study the behavior of neutrons in a cold Lucite moderator. The diffusion of neutrons in a cold moderator is described as a two-step process. In the first step, the fast neutrons produced by a neutron source collide with the nuclei of Lucite, losing energy until they reach thermal energies. In the second step, the thermal neutrons continue to diffuse without any significant loss of energy until they are absorbed or leak out of the system. However, because the Lucite moderator is at low temperature, there is less up scattering in the neutron energy compared to a Lucite moderator at room temperature. Experiments were performed to study the behavior of neutrons and their distribution in a cold Lucite moderator and their results compared to simulations. Based on these measurements, an estimation of the absorption cross section at -78.5 °C yielded a value of 0.54 barns ± 0.02 barns.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Analysis of H 2 O Pulsed Neutron Die Away Experiments to the H-H 2 O Thermal Scattering Law

Lawrence Livermore National Laboratory is conducting new Pulsed-Neutron Die-Away (PNDA) benchmark experiments to validate neutron thermal scattering laws (TSLs). TSLs are important data for modeling thermal fission reactors, criticality safety scenarios, and radiation protection and detection, i.e. any application with thermal neutrons. These simulations require high-quality nuclear data, with confidence in their quality established through validation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant at or Near Delayed Critical [Abstract]

Experimenters at Los Alamos National Laboratory (LANL) measure the prompt neutron decay constant for many experiments at the National Criticality Experiments Research Center (NCERC) to infer reactivity and the effective neutron multiplication factor. These quantities are very important for nuclear criticality safety and validating nuclear data. Uncertainty in measures of criticality of an experimental configuration can be determined prior to physically performing the experiment by applying first order perturbation theory to Monte Carlo codes, such as MCNP®. The first order perturbation theory produces first derivatives of some nuclear parameter to nuclear data (e.g., cross section data). This first derivative is commonly referred to as a sensitivity coefficient. Currently, the MCNP® software has the capability of computing effective neutron multiplication factor sensitivity coefficients to cross section data. This work builds off of this MCNP® capability and the first order perturbation theory to provide a method of calculating sensitivity coefficients for the prompt neutron decay constant at or near delayed critical to cross section data. The prompt neutron decay constant sensitivity coefficient calculated in this work does not depend on any modification of the MCNP® source code. Prompt neutron decay constant sensitivity coefficient calculations can be used to infer reactivity and effective neutron multiplication factor sensitivity coefficient values as well. By investigating the trends of prompt neutron decay constant sensitivity coefficients for nuclide-reaction pairs across energy spectra, experiments can be designed to maximize or minimize the uncertainty in the prompt neutron decay constant in a particular energy region, which can lead to further optimization studies. Prompt neutron decay constant sensitivity coefficients will be calculated for the Jezebel benchmark. Subsequently, these sensitivity coefficients will be used in a data assimilation process to determine if there is or are optimal experiments that can be performed to provide insight into adjustments of uncertain/inaccurate cross section data. Specifically, the effect of the prompt neutron decay constant sensitivity coefficients on the nuclear data-induced uncertainty in the effective neutron multiplication factor will be examined

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks [Slides]

This presentation discusses Nuclear Criticality Safety (NCS) and how designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear experiments. The presentation poses the question of how this analysis can be performed and states that the answer lies in matching new nuclear experiments with existing benchmark experiments using similarity metrics. By increasing the criticality safety of the application in this work, higher mass limits could be used in PF-4 operations. Additionally, the presentation discusses MCNP6.2®, Whisper-1.1, the software that can be used in this analysis. Also discussed is the fact that International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks rarely match new nuclear applications and that there are significant differences in given set of materials and/or geometry. If there are no benchmarks that match the application, the presentation discusses the possibility of creating new benchmarks. In conclusion, this work presents a Gaussian process (GP) optimization scheme that was used to generate new benchmarks with the highest sensitivity-based similarity metrics to user-defined nuclear applications. The Gaussian process optimization successfully designed 3 new experimental benchmarks that were highly correlated to the application of interest and had k eff values near critical. Optimization over c k,i-r has shown that investigating specific isotope reactions for different applications is crucial to designing benchmark experiments. Partial contribution from Pu dominates c k similarity metric. Future work includes testing new stand-alone similarity metrics or new combinations of similarity metrics as the design criterion of this optimization – design criterion is application dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-523: Design of a UO 2 -BeO Critical Experiment at Sandia [Slides]

This lecture is on the design of a Uranium Dioxide-Beryllium Oxide UO 2 -BeO Critical Experiment at Sandia. This presentation provides background info on the Annular Core Research Reactor (ACRR). Additionally, this presentation shows experimental and alternative designs and concludes with a sensitivity analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Fidelity Measurements for Flattop-HEU Benchmark Reevaluation

Flattop was first built in the 1950’s at Los Alamos National Laboratory. Flattop-HEU is composed of a sphere of highly enriched uranium (HEU) surrounded by a thick spherical natural uranium (NU) reflector. The reflector is composed of three parts: a stationary hemisphere and two movable quarter spheres. For fine control of the reactivity of the system, there are three control rods of natural uranium located in voids in the stationary hemisphere. The final components that make Flattop a useful critical assembly are the glory hole and mass adjustment pieces. These pieces can be loaded in various configurations into the glory hole and the core pedestal to control the known worth of the system. The glory hole and mass adjustment pieces are mostly small pieces of HEU with some mass adjustment pieces fabricated from NU. This allows for the irradiation of samples to a specified level. To better document the system, Flattop was evaluated and included in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook. The original benchmark evaluation of Flattop-HEU was written in 1999 based on an experiment completed in the 1960’s. This original evaluation was written to provide a single diameter that defined critical mass; however, as computational capabilities have increased, the focus for benchmark evaluations has shifted to include detailed modelswith all physical dimensions. Thus, as Flattop is a lynchpin in critical experiment work, the benchmark is being reevaluated at current standards. This summary discusses some of the largest known uncertainties from the evaluation and the high-fidelity measurements taken to reduce these uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rossi-α Measurements on a System Consisting of Weapons Grade Plutonium Moderated by Polyethylene [Poster]

A series of experiments nicknamed "TEX," standing for Thermal-Epithermal eXperiments, were performed at the National Criticality Experiments Research Center (NCERC) on the Planet critical assembly. The TEX experiment campaigns are a collaboration between Los Alamos National Laboratory (LANL) and Lawrence Livermore National Laboratory (LLNL) and funded by the Nuclear Criticality Safety Program (NCSP). The TEX experiment consists of several campaigns; this work specifically discusses measurements made on one series of TEX experiments designed to examine the thermal scattering law (TSL) for polyethylene. This series consisted of two different critical configurations which contain plutonium fuel. The plutonium plates are 2 in. by 3 in. by 0.125 in. Zero Power Physics Reactor (ZPPR) plates and are placed in a tray in an array of 6 plates by 4 plates wide creating a 12 in. by 12 in. square. These trays of plutonium are interleaved between polyethylene plates. These measurements differ from previous TEX experiments in that they examine a more thermal neutron spectrum than previously examined by interleaving much thicker interstitial moderating plates than the previous measurements. The two configurations differ in the thickness of polyethylene between the fissile material. While the experiment was designed to examine the TSL, this work only examines the results of Rossi-α measurements on the two different configurations. For both configurations, Rossi-α measurements were performed to experimentally validate the neutron spectrum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Update on the Benchmark Analysis of the Jupiter Experiments: Plutonium Moderated by Lead

The Jupiter experiment was a series of measurements in the summer of 2017 to analyze the effects of voids in lead moderated plutonium assemblies. This experiment was part of a larger campaign that took place at the National Criticality Experiments Research Center (NCERC) in collaboration with the Japan Atomic Energy Agency (JAEA) that also investigated assemblies with differing uranium enrichments. The purpose for this campaign was to provide data useful for a potential lead-bismuth cooled accelerator driven system. This data is needed due to the low number of benchmarks involving lead. Given the wide use of lead for shielding in addition to new reactor designs, there is a need for further benchmarking that this experiment could help fulfill. In addition, adding more benchmarks to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) is helpful for further validation of simulation methods used for criticality safety. This summary is an update on the current progress of this analysis, and all results shown are preliminary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EUCLID Experiment: Design, Execution, and Early Results [Slides]

This presentation covers design, execution, and early results for the EUCLID experiment. Unresolved compensating errors for Pu-239 and the Joint uncertainty problems are discussed. Various tools and design implementations are discussed along with upcoming work. Additional slides compare EUCLID calculations to experiment for several nuclear data libraries. ENDF/B-VIII.1β2 is named e81b2.

97 MATHEMATICS AND COMPUTING↗

In Silico Versus In Situ: The Challenging Landscape of Nuclear Criticality Safety Training

Nuclear criticality safety grew out of the ranks of experimentalists studying the physics of chain-reacting systems at critical experiment facilities. Consequently, critical experiment facilities provide the best forum for conducting training in nuclear criticality safety. As the nuclear renaissance gains traction, there is an increased demand to train personnel in nuclear criticality safety (NCS). Strides have been made in both on-line and virtual reality based NCS training. While these are perhaps a necessary component of NCS training, hands-on training at critical experiments facilities remains the most effective means of developing competency for fissionable material handlers, managers of fissionable material operations, criticality safety analysts, and experimentalists. This paper explores the challenges of developing and maintaining workforce competency in nuclear criticality safety to support safe and efficient fissionable material operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Horizontal Split Table Conceptual Design for Validation of Nuclear Data used in Advanced Reactors [Slides]

A methodology to create conceptual designs of benchmark critical experiments for advanced reactors nuclear data testing and validation was developed. A first concept was explored, pebble-bed high-temperature gas cooled reactor, based on the HTR-10 reactor. The very high correlation is a proof of concept that the design is similar to the application, and performing such critical experiments would help nuclear data testing and validation. This proof-of-concept was included in the IER-539 CED-1:Preliminary Design of a New Horizontal Split Table report. Other concepts could be explored if needed, such as Molten-salt reactor, Sodium-cooled fast reactor or Heat pipe reactors/Microreactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Equivalent Fundamental-Mode Source Simulations for Spherical Uranium and Plutonium Systems [Abstract]

The equivalent fundamental-mode source refers to a “source” which is identically distributed in space, energy, and angle as that of a fundamental-mode fission source distribution. It has previously been shown that the system fixed source multiplication ($M_{fs}$) relates to the effective multiplication factor ($\kappa_{eff}$) as $M_{fs} = \frac{g^*}{1-k_{eff}}$ The term $\mathcal{g}$* therefore relates the system source distribution to the system equivalent fundamental-mode source. As previously shown, the $\mathcal{g}$* term is approximately 1 for deeply subcritical systems and then diverges as the system multiplication increases. For a system with a point source located in the center of an assembly (such a sphere), $\mathcal{g}$* will be greater than 1; this happens because there is a higher probability of induced fission when all of the starter neutrons originate from the center of the sphere. For a uniform source, $\mathcal{g}$* is less than 1, but does not diverge from 1 as dramatically as seen by a point source. One reason that $\mathcal{g}$* is an important parameter is that it is used in measurement methods to infer reactor kinetics parameters ($β_{eff}$ being one example). This work will discuss multiple ways to simulate $\mathcal{g}$* using MCNP®6.2, which include use of traditional methods versus a single input file method that was recently published. A discussion related to methods to simulate $M_{fs}$ will be presented. Spherical systems of Highly Enriched Uranium (HEU) will be compared with previous works. In addition, results of plutonium including multiple reflector materials will be investigated. Simulated systems will include both parametric studies as well as configurations used in recent experiments performed at the National Criticality Experiments Research Center (NCERC). These studies will include subtleties associated with system geometry that have not been previously shown. Last, this work will investigate the relationship between $\mathcal{g}$* and reactor kinetics parameters (such as $β_{eff}$).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Deimos Experiment: Advanced Reactor Testbed

Advanced reactor initiatives are growing significantly through programs nationwide. This research area includes small modular reactors, microreactors, and space reactors. Many of the reactors being designed are untested concepts. They include unique moderators, varying fuel types, high temperatures, and compact configurations. The shift in fuel type, from highly enriched uranium (HEU) to high assay, low enriched uranium (HALEU), is particularly important as it has driven many of the other changes. For example, lower enrichment requires advanced moderators, which in turn require different reflectors to make the systems compact. The change in materials including the transition from HEU to HALEU affects the temperature feedback of the systems. Additionally, these advanced reactor concepts generally have a thermal neutron spectrum in contrast to earlier fast spectrum advanced reactor. With the extensive changes from previous reactor designs, validation experiments are needed. The National Criticality Experiments Research Center (NCERC) is uniquely equipped to perform such experiments. The Deimos experiment, designed for execution at NCERC, will serve as a testbed for advanced reactor concepts. It will use HALEU fuel in a graphite matrix, provide the ability to use advanced moderators, and allow measurements of temperature reactivity coefficients (TRCs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity-based Similarity Metrics for New Experiment Design Optimization

The nuclear data used in advanced reactor simulations requires validation. Data from nuclear criticality experiments can provide this validation. New nuclear criticality experiment design requires extensive knowledge and expert judgement such that the experimental design parameters are selected in such a way to keep the experiment subcritical. To aide in this experimental design process, professionals can utilize sensitivity and uncertainty analysis. Sensitivity and uncertainty analysis relies on matching new application experiments with currently existing benchmark experiments. Currently, there is functionality in the Whisper 1.1 software package to calculate a similarity metric based on neutron multiplication factor sensitivity coefficients between a new application designed by the user and existing International Criticality Safety Benchmark Experiment Project (ICSBEP) benchmarks. The Whisper 1.1 software package is included in Monte Carlo N-Particle ® Code Version 6.21 (MCNP ® 6.2). This work is geared toward expanding this capability to new similarity metrics based on beta-effective sensitivity coefficients and reactivity coefficient sensitivity coefficients. While the investigation of these sensitivity coefficients is presented in detail in separate works at this same conference, this work will be primarily focused on studying the similarity metrics in more detail. These similarity metrics will then be incorporated into the optimization algorithms used for experiment design in EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data), which is a Los Alamos National Laboratory (LANL) project designed to constrain nuclear data of interest, such that adjustments can be made to possible inaccuracies. A more detailed optimization can be subsequently performed by breaking down these similarity metrics by isotope, reaction, and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hydra: Computer Vision for Online Data Quality Monitoring

Hydra is a system utilizing computer vision for near real-time data quality monitoring. Currently operational across all of Jefferson Lab’s experimental halls, it reduces the workload of shift takers by autonomously monitoring diagnostic plots during experiments. Hydra uses "off-the-shelf" supervised learning technologies and is supported by a comprehensive MySQL database. To simplify access, web apps have been developed to facilitate both labeling and monitoring of Hydra’s inferences. Hydra can connect with the alarm system and incorporates complete historical tracking, enabling it to identify issues that shift takers could miss. When issues are detected, a natural first question is: "Why does Hydra think there is a problem?" To answer, Hydra employs Gradient-weighted Class Activation Maps (GradCAM) to identify regions of the image that are important for the specific classification. This interpretive layer enhances transparency and trustworthiness, which is essential for integration with experiment workflows and operation. The Hydra system, results, and sociological considerations for deployment will be discussed.

Jeske, Torri↗

Benchmark Evaluation of one Dimensional Array of HEU Moderated and Reflected by Lucite [Poster]

Two critical experiments with HEU-Lucite were performed using the Planet Universal Critical Assembly Machine at Los Alamos National Laboratory in 2019. HEU foils were interleaved with Lucite in a column stack for moderation and reflection from the square Lucite plates. The evaluation of the experiments is presented. A Monte-Carlo (MCNP6) calculation model was developed for the determination of uncertainties and their effect on the multiplication factor. Experimental uncertainties were found to be low with the overall uncertainty in k eff approximately 240 pcm. The comparison of calculations with experimental data is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗