Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Velocity Dispersions of Massive Quiescent Galaxies from Weak Lensing and Spectroscopy

We use MMT spectroscopy and deep Subaru Hyper Suprime-Cam (HSC) imaging to compare the spectroscopic central stellar velocity dispersion of quiescent galaxies with the effective dispersion of the dark matter halo derived from the stacked lensing signal. The spectroscopic survey (the Smithsonian Hectospec Lensing Survey) provides a sample of 4585 quiescent galaxy lenses with measured line-of-sight central stellar velocity dispersion ($\sigma_{\rm SHELS}$) that is more than 85\% complete for $R < 20.6$, $D_{n}4000> 1.5$ and $M_{\star} > 10^{9.5}{\rm M}_{\odot}$.The median redshift of the sample of lenses is 0.32. We measure the stacked lensing signal from the HSC deep imaging. The central stellar velocity dispersion is directly proportional to the velocity dispersion derived from the lensing $\sigma_{\rm Lens}$, $\sigma_{\rm Lens} = (1.05\pm0.15)\sigma_{\rm SHELS}+(-21.17\pm35.19)$. The independent spectroscopic and weak lensing velocity dispersions probe different scales, $\sim3$kpc and $\gtrsim$ 100 kpc, respectively, and strongly indicate that the observable central stellar velocity dispersion for quiescent galaxies is a good proxy for the velocity dispersion of the dark matter halo. We thus demonstrate the power of combining high-quality imaging and spectroscopy to shed light on the connection between galaxies and their dark matter halos.

79 ASTRONOMY AND ASTROPHYSICS↗

(abstract) Mars Global Surveyor: A Global Mapping Mission

The Mars Global Surveyor Mission will launch a single spacecraft to Mars in November 1996. After arrival at the planet in September 1997 aerobraking will be used to lower the spacecraft into a low, sun-synchronous, polar-mapping orbit over several months. Early in 1998 mapping observations will begin and continue for a Mars year (687 days). Following completion of this first Mars year of mapping the spacecraft will continue to act as a relay orbiter for an additional three Earth years. The five instruments carried involve magnetometry, surface and atmosphere imaging, atmospheric sounding, laser altimetry, gravity and thermal emission spectroscopy. In addition, the spacecraft carries a Mars relay receiver/transmitter which will operate over the entire five year orbital mission ending in January of 2003. The Mars Global Surveyor mission is intended to accomplish a portion of the scientific objectives of the Mars Observer mission which was lost in 1993 three days before entering Mars orbit. The instrumentation to be used for the magnetometers, cameras, laser altimeter, emission spectrometer and radio science are very nearly the same as those carried by Mars Observer. The spacecraft design will be new but will use spare equipment from Mars Observer and has a mass about two and one-half time smaller. All experiments will be controlled remotely from their investigators home installation. The long planned period of observation supports the mission's global and seasonal objectives.

Mars Global Surveyor Mars Observer mapping spectro↗

Height-resolved emission spectroscopy and high-speed imaging of the TiAl6V4 vapor plume under laser powder bed fusion conditions

Optical emission spectroscopy is increasingly used as an in situ monitoring technique during laser powder bed fusion (LPBF) because plume emission holds elemental information not found in other in situ sensing techniques. This work explores the shape, stability, and temperature of the emission plume above the melt pool of Ti6Al4 V undergoing laser scans under LPBF-like processing conditions, using high-speed video and height-resolved spectroscopy to study the details of plume dynamics. Optical emission spectroscopy is conducted in the 480 nm to 525 nm region, where Ti emission is strong, with 0.3 mm vertical resolution above the baseplate. The Boltzmann plot method is used to determine temperature at each probed elevation, which indicates that the hottest location of the plume is occasionally elevated 0.3 mm to 0.6 mm above the scanning surface. The results show that the plume shape, stability, temperature, and spectra are highly dependent on the processing conditions. We highlight some of the complexities of optical emission spectroscopy and discuss potential challenges for implementing optical emission spectroscopy across an entire build.

36 MATERIALS SCIENCE↗

Simulating Reflected Light Exoplanet Spectra of the Promising Direct Imaging Target, υ Andromedae d, with a New, Fast Sampling Method Using the Planetary Spectrum Generator

Simulations of exoplanet albedo profiles are key to planning and interpreting future direct imaging observations. In this paper we demonstrate the use of the Planetary Spectrum Generator (PSG) to produce simulations of reflected light exoplanet spectra. We use PSG to examine multiple issues relevant to all models of directly imaged exoplanet spectra and to produce sample spectra of the bright, nearby exoplanet υ Andromedae d (υ And d), a potential direct imaging target for next-generation facilities. We introduce a new, fast, and accurate subsampling technique that enables calculations of disk-integrated spectra one order of magnitude faster than Chebyshev–Gauss sampling for moderate- to high-resolution sampling. Using this method and a first-principles-derived atmosphere for υ And d, we simulate phase-dependent spectra for a variety of different potential atmospheric configurations. The simulated spectra for υ And d include versions with different haze and cloud properties. Based on our combined analysis of this planet’s orbital parameters, phase- and illumination-appropriate model spectra, and realistic instrument noise parameters, we find that υ And d is a potentially favorable direct imaging and spectroscopy target for the Coronagraph Instrument (CGI) on the Nancy Grace Roman Space Telescope. When a noise model corresponding to the Roman CGI SPC spectroscopy mode is included, PSG predicts the time required to reach a signal-to-noise ratio of 10 of the simulated spectra in both the central wavelength bin of the Roman CGI SPC spectroscopy mode (R = 50 spectrum) and of the Band 1 HLC imaging mode is approximately 400 and less than 40 hr, respectively. We also discuss potential pathways to extricating information about the planet and its atmosphere with future observations and find that Roman observations may be able to bound the interior temperature of the planet.

74 ATOMIC AND MOLECULAR PHYSICS↗

Imaging Nanoscale Energy Transport and Conversion with Ultrafast Electron Microscopy (Final Technical Report)

Light-matter interactions are ubiquitous in nature and reside at the heart of innumerable technologies. The cascade of processes that occur when a material absorbs a photon of light are exceedingly complex and are interwoven in both space and time, rendering precise determination of the atomic-scale and ultrafast mechanisms immensely challenging. The advent of methods for generating short pulses of light several decades ago led to major advances in understanding the initial moments of light absorption and the resultant effects, though directly interrogating the response of the atoms within the material continued to prove challenging. More recently, methods for generating ultrashort pulses of X-rays and fast electrons have opened the way to probing photoinduced structural dynamics of a wide range of matter in multiple phases. An especially promising laboratory-scale method is ultrafast electron microscopy (UEM), wherein the modalities of conventional transmission electron microscopes (imaging, diffraction, spectroscopy) are extended into the femtosecond temporal regime. Here, the ultrafast imaging and diffraction modalities of UEM were used to study the transient structural aspects of photoexcitation of semiconducting materials (e.g., spatially-resolved electron-phonon coupling, excitation and emission of acoustic phonons, and discrete nanoscale scattering processes). The project had three main objectives: (1) determination of the excitation mechanisms of dense, hypersonic charge-carrier waves and the spatially mediated means by which they couple to the lattice via coherent phonon emission, especially with UEM imaging, wherein effects of nanoscale structural and morphological features on the coupling and relaxation dynamics are expected to dictate nucleation sites and preferred wave vectors, (2) elucidation of photoinduced acoustic-phonon seeding, emergence, propagation, and decay over nanoscale crystal regions and especially with respect to local strain fields and atomic-scale disruptions in lattice order, and (3) interwoven with the first two were efforts aimed at realizing combined angstrom-femtosecond spatiotemporal imaging with UEM. The outcomes and impacts of this project were the generation of new knowledge with respect to fundamental light-matter interactions and, especially, the spatially-mediated excitation and evolution of the structural response of materials following coherent photoexcitation. Importantly, the spatial and temporal resolutions of the UEM imaging modalities used are well-suited for such studies and enable spatially-resolved mechanisms to be determined as a function of atomic order, structural features, and morphology. In addition, ultrafast crystallographic measurements were used to correlate real- and reciprocal-space dynamics in order to determine atomic-scale preferential wave vectors and ultrafast scattering mechanisms, especially as dictated by specimen boundary conditions. The obtained results, as detailed in peer-reviewed publications and presentations, illustrate the importance of ultrafast, angstrom-scale real-space imaging for developing a comprehensive understanding of energy transport and conversion in materials.

47 OTHER INSTRUMENTATION↗

Correlative acoustic time-of-flight spectroscopy and X-ray imaging to investigate gas-induced delamination in lithium-ion pouch cells during thermal runaway

It remains difficult to detect internal mechanical deformation and gas-induced degradation in lithium-ion batteries, especially outside specialized diagnostics laboratories. In this work, we demonstrate that electrochemical acoustic time-of-flight (EA-ToF) spectroscopy can be used as an insightful and field-deployable diagnostic/prognostic technique to sense the onset of failure. A 210 mAh commercial lithium-ion cell undergoing thermal abuse testing is probed with in situ and operando EA-ToF spectroscopy, together with simultaneous fractional thermal runaway calorimetry (FTRC) and synchrotron X-ray imaging. The combination of X-ray imaging and EA-ToF analysis provides new understanding into the through-plane mechanical deformation in lithium-ion batteries through direct visualisation and the acoustic ToF response. Internal structural changes, such as gas-induced delamination, are identified using EA-ToF spectroscopy due to variations in the attenuation and signal peak shifts. This is corroborated using X-ray imaging, demonstrating EA-ToF spectroscopy as a promising technique for detecting onset of battery failure.

25 ENERGY STORAGE↗

The Infrared-Optical Telescope (IRT) of the Exist Observatory

The IRT is a 1.1m visible and infrared passively cooled telescope, which can locate, identify and obtain spectra of GRB afterglows at redshifts up to z 20. It will also acquire optical-IR, imaging and spectroscopy of AGN and transients discovered by the EXIST (The Energetic X-ray Imaging Survey Telescope). The IRT imaging and spectroscopic capabilities cover a broad spectral range from 0.32.2m in four bands. The identical fields of view in the four instrument bands are each split in three subfields: imaging, objective prism slitless for the field and objective prism single object slit low resolution spectroscopy, and high resolution long slit on single object. This allows the instrument, to do simultaneous broadband photometry or spectroscopy of the same object over the full spectral range, thus greatly improving the efficiency of the observatory and its detection limits. A prompt follow up (within three minutes) of the transient discovered by the EXIST makes IRT a unique tool for detection and study of these events, which is particularly valuable at wavelengths unavailable to the ground based observatories.

Kutyrev, Alexander↗

Visible core spectroscopy at Wendelstein 7-X

This paper presents an overview of recent hardware extensions and data analysis developments to the Wendelstein 7-X visible core spectroscopy systems. These include upgrades to prepare the in-vessel components for long-pulse operation, nine additional spectrometers, a new line of sight array for passive spectroscopy, and a coherence imaging charge exchange spectroscopy diagnostic. Progress in data analysis includes ion temperatures and densities from multiple impurity species, a statistical comparison with x-ray crystal spectrometer measurements, neutral density measurements from thermal passive Balmer-alpha emission, and a Bayesian analysis of active hydrogen emission, which is able to infer electron density and main ion temperature profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

1999 Marsokhod Field Experiment: A Simulation of a Mars Rover Science Mission

A field experiment to simulate a rover mission to Mars was performed in February 1999. This experiment, the latest in a series of rover field experiments, was designed to demonstrate and validate technologies and investigation strategies for high-science, high-technology performance, and cost-effective planetary rover operations. Objectives: The experiment objectives were to: (1) train scientists in a mission configuration relevant to Surveyor program rover missions at a terrestrial analog field site simulating the criteria of high-priority candidate landing-sites on Mars; (2) develop optimal exploration strategies; (3) evaluate the effectiveness of imaging and spectroscopy in addressing science objectives; (4) assess the value and limitation of descent imaging in supporting rover operations; and (5) evaluate the ability of a science team to correctly interpret the geology of the field site using rover observations. A field site in the California Mojave Desert was chosen for its relevance to the criteria for landing site selection for the Mars Surveyor program. These criteria are: (1) evidence of past water activity; (2) presence of a mechanism to concentrate life; (3) presence of thermal energy sources; (4) evidence of rapid burial; and (5) excavation mechanisms that could expose traces of life.

Stoker, C.↗

The Distance and Mass of the Galaxy Cluster Abell 1995 Derived From Sunyaev-Zel'dovich Effect and X-Ray Measurements

We present multi-wavelength observations of the Abell 1995 galaxy cluster. From analysis of x-ray spectroscopy and imaging data we derive the electron temperature, cluster core radius, and central electron number density. Using optical spectroscopy of 15 cluster members, we derive an accurate cluster redshift and velocity dispersion. Finally, the interferometric imaging of the SZE toward Abell 1995 at 28.5 GHz provides a measure of the integrated pressure through the cluster.

Patel, Sandeep K.↗

The Distance and Mass of the Galaxy Cluster Abell 1995 Derived from Sunyaev-Zeldovich Effect and X-Ray Measurements

We present multiwavelength observations of the Abell 1995 galaxy cluster. From an analysis of X-ray spectroscopy and imaging data, we derive the electron temperature, cluster core radius, and central electron number density. Using optical spectroscopy of 15 cluster members, we derive an accurate cluster redshift and velocity dispersion. Finally, the interferometric imaging of the Sunyaev-Zeldovich effect toward Abell 1995 at 28.5 GHz provides a measure of the integrated pressure through the cluster. The X-ray and Sunyaev-Zeldovich effect observations are combined to determine the angular diameter distance to the cluster of D(sub A) = 1294(sup +294 +438, sub -283 -458) Mpc (Statistical followed by systematic uncertainty), implying a Hubble constant of H(sub 0) = 52.2(sup +11.4 +18.5, sub -11.9 -17.7) km/s.Mpc for Omega(sub M) = 0.3 and Omega(sub lambda) = 0.7. We find a best-fit H(sub 0) of 46 km/s.Mpc for the Omega(sub M) = 1 and Omega(sub lambda) = 0 cosmology, and 48 km/s.Mpc for Omega(sub M) = 0.3 and Omega(sub lambda) = 0.0. The X-ray data are also used to derive a total cluster mass of M(sup HSE, sub tot)(r(sub 500)) = 5.18(sup +0.62, sub -0.48) x 10(exp 14)/h solar mass; the optical velocity dispersion yields an independent and consistent estimate of M(sup virial, sub tot)(r(sub 500)) = 6.35(sup +1.51, sub -1.19) X 10(exp 14) /h solar mass. Both of the total mass estimates are evaluated at a fiducial radius, r(sub 500) = 830 /h kpc, where the overdensity is 500 times the critical density. The total cluster mass is then combined with gas mass measurements to determine a cluster gas mass fraction of F(sub g) = 0.056(sup +0.010, sub -0.013) /h(sup 3/2) in combination with recent baryon density constraints, the measured gas mass fraction yields an upper limit on the mass density parameter of Omega(sub M) h(sup 1/2) <= 0.34(sup +/0.06, sub 0.05.

Patel, Sandeep K.↗

Three-dimensional (3D) velocity map imaging: from technique to application

The velocity map imaging (VMI) technique was first introduced by Eppink and Parker in 1997, as an improvement to the original ion imaging method by Houston and Chandler in 1987. The method has gained huge popularity over the past two decades and has become a standard tool for measuring high-resolution translational energy and angular distributions of ions and electrons. VMI has evolved gradually from 2D momentum measurements to 3D measurements with various implementations and configurations. The most recent advancement has brought unprecedented 3D performance to the technique in terms of resolutions (both spatial and temporal), multi-hit capability as well as acquisition speed while maintaining many attractive attributes afforded by conventional VMI such as being simple, cost-effective, visually appealing and versatile. Here, in this tutorial, we will discuss many technical aspects of the recent advancement and its application in probing correlated chemical dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

Development of a high resolution liquid xenon imaging chamber for gamma-ray astronomy

The objective was to develop the technology of liquid xenon (LXe) detectors for spectroscopy and imaging of gamma rays from astrophysical sources emitting in the low to medium energy regime. In particular, the technical challenges and the physical processes relevant to the realization of the LXe detector operated as a Time Projection Chamber (TPC) were addressed and studied. Experimental results were obtained on the following topics: (1) long distance drift of free electrons in LXe (purity); (2) scintillation light yield for electrons and alphas in LXe (triggering); and (3) ionization yield for electrons and gamma rays in LXe (energy resolution). The major results from the investigations are summarized.

Aprile, Elena↗

Research in planetary astronomy

The composition, structure and processes operating on the surfaces of solar system objects were determined using the Mauna Kea observing facilities and modern instrumentation. Reflectance spectroscopy and multispectral imaging in the 0.3 to 5.0 micrometers spectral region are the major techniques used. Major focus was in qualifying and using the new imaging spectrometer and the 2-D IR detectors for spectroscopy and imaging. The major observational program emphasis was on preparing for the next Mars opposition, and searching for compositional units in the lunar highlands.

Mccord, T. B.↗