Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

The Design, Verification and Performance of the James Webb Space Telescope

The James Webb Space Telescope (JWST) is NASA’s flagship mission successor to the highly successful Hubble Space Telescope. It is an infrared observatory featuring a cryogenic 6.6 m aperture, deployable Optical Telescope Element (OTE) with a payload of four science instruments (SIs) assembled into an Integrated Science Instrument Module (ISIM) that provide imagery and spectroscopy in the near-infrared band between 0.6 and 5 μm and in the mid-infrared band between 5 and 28.1 μm. JWST was successfully launched on 2021 December 25 aboard an Ariane 5 launch vehicle. All 50 major deployments were successfully completed on 2022 January 8. The observatory performed all midcourse correction maneuvers and achieved its operational mission orbit around the Sun–Earth second Lagrange point (L2). All commissioning and calibration activities have been completed, and JWST has begun its science mission. This paper will provide a description of the driving requirements and their technical challenges, the engineering processes involved in the design formulation, the resulting observatory design, the verification programs that proved it to be flightworthy, and the measured on-orbit performance of the observatory. Since companion papers will describe the details of the OTE and SIs, this paper will concentrate on describing the key features of the observatory architecture that accommodates these elements, particularly those features and capabilities associated with accommodating the radiometric and image-quality performance.

Galaxy evolution↗

The Science Performance of JWST as Characterized in Commissioning

This paper characterizes the actual science performance of the James Webb Space Telescope (JWST), as determined from the six month commissioning period. We summarize the performance of the spacecraft, telescope, science instruments, and ground system, with an emphasis on differences from pre-launch expectations. Commissioning has made clear that JWST is fully capable of achieving the discoveries for which it was built. Moreover, almost across the board, the science performance of JWST is better than expected; in most cases, JWST will go deeper faster than expected. The telescope and instrument suite have demonstrated the sensitivity, stability, image quality, and spectral range that are necessary to transform our understanding of the cosmos through observations spanning from near-earth asteroids to the most distant galaxies.

Infrared astronomy↗

Modis TEB Electronic Crosstalk Correction Update and Impact on L1B Product Uncertainty

The MODIS instruments on board the Terra and Aqua satellites have been in operation for over 22 and 20 years, respectively. The instruments’ calibration accuracy has been maintained, even with instrument degradation. Electronic crosstalk in the thermal emissive bands (TEB) is a known issue with an increasing impact on the calibration and product. The Terra MODIS photovoltaic (PV) longwave infrared (LWIR) bands crosstalk corrections have been applied in Collection 6.1 (C6.1). However, the electronic crosstalk contamination for some detectors in the mid-wave infrared(MWIR) bands and the Aqua PVLWIR bands affect the Level-1B(L1B) product’s measurement accuracy and image quality. In Collection 7 (C7), crosstalk corrections for select detectors in the Terra and Aqua MWIR and Aqua PV LWIR bands are applied. The entire mission crosstalk coefficients for the select detectors and bands are derived from scheduled lunar observations and populated in the form of look-up tables (LUTs). The Aqua PV-LWIR bands exhibit similar downward crosstalk trends as the Terra PV-LWIR bands, especially in recent years. The crosstalk coefficients and their trends provide a guideline for the correction application. Earth measurement analyses before and after the correction provide contamination and correction assessments. It has been shown that the product quality is enhanced with the crosstalk correction applied in C7. For C7, the crosstalk coefficient uncertainty is derived from the fit residuals between the measured values and a linear fit over a three-year sliding window. The uncertainty propagation is modeled and applied in the total uncertainty calculation intheL1B product. The TEB electronic cross talk LUT shave been processed over the entire Terra and Aqua MODIS missions. This paper presents the C7 crosstalk correction, as well as its assessment and uncertainty propagation algorithm to the TEB uncertainty.

Tiejun Chang↗

Electrical Impedance Tomography Technology: 2013 Center Innovation Fund Final Report

Electrical impedance tomography is a medical noninvasive imaging technology which has advantages over other medical imaging technologies for medically safe long term real time internal imaging monitoring applications in human patients. The technology is much more compact, portable, low power and potentially more low cost compared to other medical image technologies, making it very well suited for medical aerospace and spaceflight applications. EIT technology’s main drawback has been low image resolution, and consequently improving EIT resolution is the primary research goal, as well as increasing imaging speed for real time animation imaging. In a relatively short time the BERL group has brought together design plans, technical resources and has built and tested hardware with the purpose of improving EIT imaging technology. EIT prototype system development plans and system designs have been made to target needed EIT technical improvement in electronic and computer hardware as well as EIT software technology. New hardware design and fabrication resources and technologies have been brought together through resourceful use of existing equipment and software at BERL, and a significant advance has been made in custom electronic hardware prototyping capabilities in collaboration with EFAL, for mutual benefit for both NASA KSC laboratories. BERL has gained significant EIT software capability and tested EIT imaging algorithm code through collaboration with an internationally recognized EIT software development and research forum. A new custom workstation has been developed, built and tested using internal resources, equipment and expertise, that includes a new state-of-the-art massively parallel technology that is commercially available. Custom prototype hardware has been designed and tested, a high priority electronic design, key to improving electronic performance and image quality, has been researched and tested in four designs, with a summary of test results of the selected design illustrated here. The selected design performance exceeds the developed EIT design hardware specifications.

Michael R Lapointe↗

Habitable Worlds Observatory

After 2+ years in space, Webb’s image quality remains twice as sharp as required and a great starting point for the Habitable Worlds Observatory (HWO).

HWO↗

Commercial Synthetic Aperture Radar Data for Surface Deformation and Change

The commercial synthetic aperture radar (SAR) market is experiencing year-over-year growth and is currently capable of imaging anywhere in the world within an hour at X-band. Surface Deformation and Change (SDC) is a mission study at NASA to investigate innovative architectures beyond the NASA-ISRO SAR (NISAR) mission in the next decade. In this article we present preliminary findings on the technical capabilities of the currently available commercial SAR data, and investigate their applicability to SDC goals, such as imaging quality and retrieval of surface motion.

SAR↗

Evaluation of Landsat-4 Thematic Mapper and multispectral scanner data quality

Landsat-4 image data quality was evaluated for test sites in Iowa and Illinois. Radiometric and geometric quality was tested and an applications evaluation was carried out using a cooling-pond thermal-mapping example. Geometric quality was found to be generally very good. Small errors were found in registration of the middle IR bands of the TM and the thermal IR band was found to be misregistered by one 120-meter pixel. Radiometric quality of the TM is excellent with only minor striping effects.

Bartolucci, L. A.↗

Second Harmonic Imaging improves Echocardiograph Quality on board the International Space Station

Ultrasound (US) capabilities have been part of the Human Research Facility (HRF) on board the International Space Station (ISS) since 2001. The US equipment on board the ISS includes a first-generation Tissue Harmonic Imaging (THI) option. Harmonic imaging (HI) is the second harmonic response of the tissue to the ultrasound beam and produces robust tissue detail and signal. Since this is a first-generation THI, there are inherent limitations in tissue penetration. As a breakthrough technology, HI extensively advanced the field of ultrasound. In cardiac applications, it drastically improves endocardial border detection and has become a common imaging modality. U.S. images were captured and stored as JPEG stills from the ISS video downlink. US images with and without harmonic imaging option were randomized and provided to volunteers without medical education or US skills for identification of endocardial border. The results were processed and analyzed using applicable statistical calculations. The measurements in US images using HI improved measurement consistency and reproducibility among observers when compared to fundamental imaging. HI has been embraced by the imaging community at large as it improves the quality and data validity of US studies, especially in difficult-to-image cases. Even with the limitations of the first generation THI, HI improved the quality and measurability of many of the downlinked images from the ISS and should be an option utilized with cardiac imaging on board the ISS in all future space missions.

Garcia, Kathleen↗

Physical correction filter for improving the optical quality of an image

A family of physical correction filters is described. Each filter is designed to correct image content of a photographed scene of limited resolution and includes a first filter element with a pinhole through which light passes to a differential amplifier. A second filter element through which light passes through one or more openings, whose geometric configuration is a function of the cause of the resolution loss included. The light, passing through the second filter element, is also supplied to the differential amplifier whose output is used to activate an optical display or recorder to reproduce a photograph or display of the scene in the original photograph or display of the scene in the original photograph with resolution which is significantly greater than that characterizing the original photograph.

Lee, S. Y.↗

On-Orbit Lunar Modulation Transfer Function Measurements for the Moderate Resolution Imaging Spectroradiometer

Spatial quality of an imaging sensor can be estimated by evaluating its modulation transfer function (MTF) from many different sources such as a sharp edge, a pulse target, or bar patterns with different spatial frequencies. These well-defined targets are frequently used for prelaunch laboratory tests, providing very reliable and accurate MTF measurements. A laboratory-quality edge input source was included in the spatial-mode operation of the Spectroradiometric Calibration Assembly (SRCA), which is one of the onboard calibrators of the Moderate Resolution Imaging Spectroradiometer (MODIS). Since not all imaging satellites have such an instrument, SRCA MTF estimations can be used as a reference for an on-orbit lunar MTF algorithm and results. In this paper, the prelaunch spatial quality characterization process from the Integrated Alignment Collimator and SRCA is briefly discussed. Based on prelaunch MTF calibration using the SRCA, a lunar MTF algorithm is developed and applied to the lifetime on-orbit Terra and Aqua MODIS lunar collections. In each lunar collection, multiple scan-directionMoon-to-background transition profiles are aligned by the subpixel edge locations from a parametric Fermi function fit. Corresponding accumulated edge profiles are filtered and interpolated to obtain the edge spread function (ESF). The MTF is calculated by applying a Fourier transformation on the line spread function through a simple differentiation of the ESF. The lifetime lunar MTF results are analyzed and filtered by a relationship with the Sun-Earth-MODIS angle. Finally, the filtered lunarMTF values are compared to the SRCA MTF results. This comparison provides the level of accuracy for on-orbit MTF estimations validated through prelaunch SRCA measurements. The lunar MTF values had larger uncertainty than the SRCA MTF results; however, the ratio mean of lunarMTF fit and SRCA MTF values is within 2% in the 250- and 500-m bands. Based on the MTF measurement uncertainty range, the suggested lunar MTF algorithm can be applied to any on-orbit imaging sensor with lunar calibration capability.

Choi, Taeyong↗

Improved image decompression for reduced transform coding artifacts

The perceived quality of images reconstructed from low bit rate compression is severely degraded by the appearance of transform coding artifacts. This paper proposes a method for producing higher quality reconstructed images based on a stochastic model for the image data. Quantization (scalar or vector) partitions the transform coefficient space and maps all points in a partition cell to a representative reconstruction point, usually taken as the centroid of the cell. The proposed image estimation technique selects the reconstruction point within the quantization partition cell which results in a reconstructed image which best fits a non-Gaussian Markov random field (MRF) image model. This approach results in a convex constrained optimization problem which can be solved iteratively. At each iteration, the gradient projection method is used to update the estimate based on the image model. In the transform domain, the resulting coefficient reconstruction points are projected to the particular quantization partition cells defined by the compressed image. Experimental results will be shown for images compressed using scalar quantization of block DCT and using vector quantization of subband wavelet transform. The proposed image decompression provides a reconstructed image with reduced visibility of transform coding artifacts and superior perceived quality.

Orourke, Thomas P.↗

The earth's surface studied from space; Proceedings of Workshop II of the COSPAR 25th Plenary Meeting, Graz, Austria, June 25-July 7, 1984

Consideration is given to: Landsat image data quality studies; a preliminary evaluation of Landsat-4 Thematic Mapper (TM) data for mineral exploration; and the early evaluation of TM data for mapping forest, agricultural and soil resources. Among other topics discussed are: shortwave infrared detection of vegetation; SPOT image quality and post-launch assessment; an evaluation of SPOT HRV simulation data for Corps of Engineers applications; and the application potential of SPOT imagery for topographic mapping. Consideration is also given to: verification studies of MOS-1 sensors; multiple sensor geocoded data; and the utility of proposed sensors for coastal engineering studies.

Ungar, S. G.↗

Exploiting Measurement Uncertainty Estimation in Evaluation of GOES-R ABI Image Navigation Accuracy Using Image Registration Techniques

In evaluating GOES-R Advanced Baseline Imager (ABI) image navigation quality, upsampled sub-images of ABI images are translated against downsampled Landsat 8 images of localized, high contrast earth scenes to determine the translations in the East-West and North-South directions that provide maximum correlation. The native Landsat resolution is much finer than that of ABI, and Landsat navigation accuracy is much better than ABI required navigation accuracy and expected performance. Therefore, Landsat images are considered to provide ground truth for comparison with ABI images, and the translations of ABI sub-images that produce maximum correlation with Landsat localized images are interpreted as ABI navigation errors. The measured local navigation errors from registration of numerous sub-images with the Landsat images are averaged to provide a statistically reliable measurement of the overall navigation error of the ABI image. The dispersion of the local navigation errors is also of great interest, since ABI navigation requirements are specified as bounds on the 99.73rd percentile of the magnitudes of per pixel navigation errors. However, the measurement uncertainty inherent in the use of image registration techniques tends to broaden the dispersion in measured local navigation errors, masking the true navigation performance of the ABI system. We have devised a novel and simple method for estimating the magnitude of the measurement uncertainty in registration error for any pair of images of the same earth scene. We use these measurement uncertainty estimates to filter out the higher quality measurements of local navigation error for inclusion in statistics. In so doing, we substantially reduce the dispersion in measured local navigation errors, thereby better approximating the true navigation performance of the ABI system.

navigation performance↗

Land use management in Minnesota

The author has identified the following significant results. Preliminary analysis of bulk imagery suggests that the forty-acre data cell used in the Minnesota Land Management Information Systems (MLMIS) can be utilized in interpretation of ERTS-1 data. High quality bulk images of the Twin Cities metropolitan area suggest that detail in urban land use patterns is much greater than originally anticipated. This implies a greater work effort in this area than was planned. Furthermore, the forest classes of land use can also be usefully divided into subcategories. Preliminary analysis of one rather low quality image also indicates that subclasses of wetlands can be identified. Prospects are bright for improving the potential detail that ERTS-1 can contribute to MLMIS.

Sizer, J. E.↗

Image registration error variance as a measure of overlay quality

When one image (the signal) is to be registered with a second image (the signal plus noise) of the same scene, one would like to know the accuracy possible for this registration. This paper derives an estimate of the variance of the registration error that can be expected via two approaches. The solution in each instance is found to be a function of the effective bandwidth of the signal and the noise, and the signal-to-noise ratio. Application of these results to LANDSAT-1 data indicates that for most cases, registration variances will be significantly less than the diameter of one picture element.

Mcgillem, C. D.↗

Characterization of Landsat-4 MSS and TM digital image data

The launch of Landsat-4 in July 1982 represents a continuation in the remote sensing of earth resources. The 80-m spatial resolution provided by the Multispectral Scanner (MSS) on board the satellite is fine enough to resolve many natural features and land-use details in both rural and urban settings. The second sensor of the spacecraft, the Thematic Mapper (TM), introduces a new era of sensing with refined spatial resolution (30 m) and expanded spectral coverage (7 bands). This paper describes results from engineering studies of the characteristics of digital image data from the two Landsat-4 sensors. These studies form a part of the Landsat-4 Image Data Quality Analysis program (LIDQA). The image data were generally found to be of high quality and the TM provided several improvements over the MSS, in its spatial and spectral characteristics.

Malila, W. A.↗

Characterization of LANDSAT-4 MSS and TM digital image data

The launch of LANDSAT-4 in July 1982 represents a continuation in the remote sensing of earth resources. The 80-m spatial resolution provided by the Multispectral Scanner (MSS) on board the satellite is fine enough to resolve many natural features and land-use details in both rural and urban settings. The second sensor of the spacecraft, the Thematic Mapper (TM), introduce a new era of sensing with refined spatial resolution (30 m) and expanded spectral coverage (7 bands). This paper describes results from engineering studies of the characteristics of digital image data from the two LANDSAT-4 sensors are described. These studies form a part of the LANDSAT-4 Image Data Quality Analysis program (LIDQA). The image data were generally found to be of high quality and the TM provided several improvements over the MSS, in its spatial and spectral characteristics.

Malila, W. A.↗

Advanced applications: an overview

Applications of materials in white-light optical imaging, remote-sensing systems are discussed. Image formation in terms of wavefronts and the influence of materials on the quality of images is given. The rationale for why some space optics structures are large is presented.

image quality structure material↗