Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Khayyam; Progress and Prospects of Coupling a Spatial Heterodyne Spectrometer (SHS) to a Cassegrain Telescope for Optical Interferometry

In the temporal study of faint, extended sources at high resolving power, Spatial Heterodyne Spectrometer (SHS) can offer significant advantages about conventional dispersive grating spectrometers. We describe here a four-year continuous progress in Mt. Hamilton, Lick Observatory, toward development of a prototype reflective Spacial Heterodyne Spectrometer, Khayyam, instrument-telescope configuration to combine all of the capabilities necessary to obtain high resolving power visible band spectra of diffuse targets from small aperture on-axis telescopes where significant observing time can be obtained. We will discuss the design considerations going into this new system, installation, testing of the interferometer-telescope combination, the technical challenges and procedures moving forward.

extended targets↗

Processing of KaRIn/SWOT Data

The Surface Water and Ocean Topography (SWOT) mission [1] is part of NASA’s Decadal Survey Program, and prepared jointly by NASA’s Jet Propulsion Laboratory (JPL), the French space agency (CNES), and the Canadian space agency (CSA). Launch is currently foreseen in 2020. The principal instrument KaRIn (Ka-band Radar Interferometer) would be a bistatic SAR system operating at Kaband, with 200 MHz bandwidth, covering 50 km wide near-nadir swaths (1-4° incidence) on both sides of the satellite track. The nominal payload also would include a conventional Ku/C-band nadir altimeter, a water vapor radiometer, and a precise orbit determination suite. Moreover, additional near-nadir channels from KaRIn to reduce the gap between the nominal swaths may be considered. The main mission goals would be to improve the spatio-temporal coverage of the oceans with respect to today’s nadir-looking altimeters (such as the Jason series), by providing measurements on a 1 km2 grid with virtually complete coverage up to ±78° latitude, while keeping a height precision of 1-2 cm, and to extend the altimetry measurements to continental water surfaces, including lakes, reservoirs and wetlands bigger than 250x250 m2 and rivers down to a width of 100 m (50 m as a goal), with a height precision of the order of 10 cm, represented with a horizontal point spacing of about 50 m. The fine scale of the measurements, with continuous acquisition over both oceans and continents, will result in huge data volumes, starting at the spacecraft and flowing through all links of the ground system. Furthermore, the centimetric height accuracy required means that all aspects of the processing must be considered carefully. In this article we give an overview of the foreseen data products and data processing chains for KaRIn on SWOT. Some particularly challenging processing steps are (will be) described in more detail.

Desroches, Damien↗

Method and apparatus for measuring biofilm thickness and topology

An apparatus and method of measuring biofilm and biological activity on a surface is disclosed. The apparatus includes a biofilm, which includes one or more microorganisms, grown on a substrate. A viewing window is placed on a surface of the biofilm and a gas bubble is introduced between the viewing window and the surface of the biofilm. The space between the substrate and the viewing window may be enclosed in a casing that has an inlet and an outlet, forming a flow cell. A microscope system, such as a white light interferometer, captures data of the biofilm in situ and non-destructively. The 3D images of biofilm surface have high resolution while maintaining a large field of view. The apparatuses and methods will be useful for fundamental studies of biofilms, biomedical and environmental screening, and many other applications in biology and the life sciences.

Larimer, Curtis J.↗

Dissipation Enables Strongly Detuning-Dependent Interference in Pulsed Dynamical Decoupling

One of the defining features of pulsed dynamical decoupling is its suppression of a driven qubit's sensitivity to static detuning errors between the drive field and qubit resonance. In this paper, we show that dissipation, in the form of excited-state decay, can change this behavior entirely, producing an interference signal with a strong detuning dependence. This signal arises from decay during driven evolution and relies on coherence retained by the qubit after such a decay event. We develop analytical and numerical models that capture the underlying mechanism and observe this same dissipation-induced detuning dependence experimentally in both a free-space strontium atom interferometer and a superconducting transmon qubit system. We also use this dissipation-induced detuning dependence as the basis for a new spectroscopic technique called Dissipative Carr-Purcell Spectroscopy (DCPS) and compare it with a traditional Ramsey sequence. Our results establish a regime of pulsed dynamical decoupling in which dissipation reshapes, rather than merely degrades, coherent control, and we expect these dynamics to be relevant to a wide range of quantum systems.

DeRose, Kenneth [Northwestern U.; Fermilab] (ORCID↗

Precision Cryogenic Dilatometer

A dilatometer based on a laser interferometer is being developed to measure mechanical creep and coefficients of thermal expansion (CTEs) of materials at temperatures ranging from ambient down to 15 K. This cryogenic dilatometer has been designed to minimize systematic errors that limit the best previously available dilatometers. At its prototype stage of development, this cryogenic dilatometer yields a strain measurement error of 35 ppb or 1.7 ppb/K CTE measurement error for a 20-K thermal load, for low-expansion materials in the temperature range from 310 down to 30 K. Planned further design refinements that include a provision for stabilization of the laser and addition of a high-precision sample-holding jig are expected to reduce the measurement error to 5-ppb strain error or 0.3-ppb/K CTE error for a 20-K thermal load. The dilatometer (see figure) includes a common-path, differential, heterodyne interferometer; a dual-frequency, stabilized source bench that serves as the light source for the interferometer; a cryogenic chamber in which one places the material sample to be studied; a cryogenic system for cooling the interior of the chamber to the measurement temperature; an ultra-stable alignment stage for positioning the chamber so that the sample is properly positioned with respect to the interferometer; and a data-acquisition and control system. The cryogenic chamber and the interferometer portion of the dilatometer are housed in a vacuum chamber on top of a vibration isolating optical table in a cleanroom. The sample consists of two pieces a pillar on a base both made of the same material. Using reflections of the interferometer beams from the base and the top of the pillar, what is measured is the change in length of the pillar as the temperature in the chamber is changed. In their fundamental optical and electronic principles of operation, the laser light source and the interferometer are similar to those described in Common-Path Heterodyne Interferometers (NPO-20786), NASA Tech Briefs, Vol. 25, No. 7 (July 2001), page 12a, and Interferometer for Measuring Displacement to Within 20 pm (NPO- 21221), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), page 8a. However, the present designs incorporate a number of special geometric, optical, and mechanical features to minimize optical and thermal-expansion effects that contribute to measurement errors. These features include the use of low-thermal expansion materials for structural components, kinematic mounting and symmetrical placement of optical components, and several measures taken to minimize spurious reflections of laser beams.

Dudik, Matthew↗

Particle Size Measurements From the First Fundamentals of Ice Crystal Icing Physics Test in the NASA Propulsion Systems Laboratory

This paper presents particle measurements by the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments from the first Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The work focuses on humidity sweeps at a larger and a smaller median volumetric diameter. The particle size distribution, number density, and water content measured by the Phase Doppler Interferometer and High Speed Imaging instruments from the sweeps are presented and compared. The current capability for these two instruments to measure and discriminate ICI conditions is examined.

Aircraft icing↗

Particle Size Measurements from the first Fundamentals of Ice Crystal Icing Physics Test in the NASA Propulsion Systems Laboratory

This presentation shows particle measurements by the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments from the first Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The work focuses on humidity sweeps at a larger and a smaller median volumetric diameter. The particle size distribution, number density, and water content measured by the Phase Doppler Interferometer and High Speed Imaging instruments from the sweeps are presented and compared. The current capability for these two instruments to measure and discriminate ICI conditions is examined.

thermal scaling↗

Two color multichannel heterodyne interferometer set up for high spatial resolution electron density profile measurements in TJ-II

A high spatial resolution two color [CO{sub 2}, {lambda}=10.6 {mu}m/Nd:YAG (Nd:YAG denotes neodymium-doped yttrium aluminum garnet), and {lambda}=1.064 {mu}m] expanded-beam multichannel heterodyne interferometer has been installed on the TJ-II stellarator. Careful design of the optical system has allowed complete control on the evolution of both Gaussian beams along the interferometer, as well as the evaluation and optimization of the spatial resolution to be expected in the measurements. Five CO{sub 2} (measurement) channels and three Nd:YAG (vibration compensation) channels have been used to illuminate the plasma with a probe beam of 100 mm size. An optimum interpolation method has been applied to recover both interferometric phasefronts prior to mechanical vibration subtraction. The first results of the installed diagnostic are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of losses on the quantum-noise cancellation in the SU(1,1) interferometer

Quantum-noise cancellation (QNC) is an effective method to control the noise of the quantum system, which reduces or even eliminates the noise of the quantum systems by utilizing destructive interference in the quantum system. However, QNC can be extremely dependent on the losses inside the system. In this letter, we experimentally and theoretically study how the losses can affect the QNC in the SU(1,1) interferometer. We find that losses in the different arms inside the SU(1,1) interferometer can have different effects on the QNC in the output fields from the SU(1,1) interferometer. And the QNC in the SU(1,1) interferometer can almost be insensitive to the losses in some cases. Our findings may find its potential applications in the quantum noise control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Figure and Dimension Metrology of Extremely Lightweight X-Ray Mirrors for Space Astronomy Applications

The International X-ray Observatory (IXO) is the next major space X-ray observatory, performing both imaging and spectroscopic studies of all kinds of objects in the Universe. It is a collaborative mission of the National Aeronautics and Space Administration of the United States, the European Space Agency, and Japan Aerospace Exploration Agency. It is to be launched into a Sun-Earth L2 orbit in 2021. One of the most challenging aspects of the mission is the construction of a flight mirror assembly capable focusing X-rays in the band of 0.1 to 40 keY with an angular resolution of better than 5 arc-seconds and with an effective collection area of more than 3 sq m. The mirror assembly will consist of approximately 15,000 parabolic and hyperbolic mirror segments, each of which is approximately 200mm by 300mm with a thickness of 0.4mm. The manufacture and qualification of these mirror segments and their integration into the giant mirror assembly have been the objectives of a vigorous technology development program at NASA's Goddard Space Flight Center. Each of these mirror segments needs to be measured and qualified for both optical figure and mechanical dimensions. In this talk, I will describe the technology program with a particular emphasis on a measurement system we are developing to meet those requirements, including the use of coordinate measuring machines, Fizeau interferometers, and custom-designed, and -built null lens. This system is capable of measuring highly off-axis aspherical or cylindrical mirrors with repeatability, accuracy, and speed.

Zhang, William W.↗

Optical Displacement Sensor for Sub-Hertz Applications

A document discusses a sensor made from off-the-shelf electro-optical photodiodes and electronics that achieves 20 nm/(Hz)(exp 1/2) displacement sensitivity at 1 mHz. This innovation was created using a fiber-coupled laser diode (or Nd:YAG) through a collimator and an aperture as the illumination source. Together with a germanium quad photodiode, the above-mentioned displacement sensor sensitivities have been achieved. This system was designed to aid the Laser Interferometer Space Antenna (LISA) with microthruster tests and to be a backup sensor for monitoring the relative position between a proof mass and a spacecraft for drag-free navigation. The optical displacement sensor can be used to monitor any small displacement from a remote location with minimal invasion on the system.

Abramovici, Alexander↗

Technology for Space Optical Interferometry

Optical interferometers are expected to provide the next great leap forward in space based astronomy beyond the Hubble Space Telescope. Various systems are envisioned, ranging from large orbiting structures to lunar based facilities to separated spacecraft flying in formation. Regardless of the specific architecture, these systems will present unprecedented challenges in the measurement and control of optical surfaces, hence driving the technological state-of-the-art in the areas of laser metrology and alignment and stabilization of optomechanical systems.

interferometry↗

Design and implementation of a multichannel millimeter wave interferometer for the Compact Toroidal Hybrid experiment

A three-channel 1 mm wave interferometer has been designed, assembled, and installed on the Compact Toroidal Hybrid torsatron (CTH). The interferometer design makes novel use of a subharmonic mixer for detection, which simplifies alignment. It employs a single electronically tunable source that is repetitively chirped using a sawtooth waveform of frequency up to 1 MHz. The 15.25 GHz drive oscillator is multiplied in two stages to 122 GHz before a final doubler stage brings it to 244 GHz. Local oscillator (LO) power at 122 GHz is directed through waveguide to the LO input of the subharmonic mixer of each viewing chord, simplifying alignment. Phase detection is performed by directly digitizing the amplified mixer outputs at 50 MHz and processing them with a software algorithm. Initial measurements made with the central chord of the new interferometer agree with those from the existing 4 mm system at low densities. The 1 mm system performs well in current-driven discharges reaching densities over 10{sup 19} m{sup -3}, whereas the lower frequency interferometer is found to be less reliable due to loss of fringes. This is a critical improvement for experiments studying the onset, avoidance, and vacuum magnetic transform dependence of disruptions in the CTH device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared observations of the Uranian system

Initial results are presented from analyses of IR interferometer spectrometer data collected by Voyager 2 during passes of Uranus and the moons Miranda and Ariel. The data covered reflected solar radiation in the visible and near-IR and thermal emissions between 25 and 50 microns. An equatorial atmospheric He mole fraction of 0.10-0.20 and a mass fraction of 0.16-0.34 was observed for Uranus. Para-hydrogen was also a significant fraction Uranus CH4 atmosphere. Average polar and equatorial spectra were employed to generate vertical temperature profiles between 60-900 mbar, with the finding that the temperatures at the equator and the poles are markedly similar between 400-900 mbar. The effective temperature of Uranus had a calculated upper limit of about 59.4 K, while the subsolar temperatures of Miranda and Arial were around 86 and 84 K, respectively. The albedos of the two satellites indicated surface microstructures composed of isotopically scattering grains.

Hanel, R.↗

Interferometric studies of the radiation wave front on the Luch setup

A radial shear interferometer for studying the shape of the wave front and aberrations of the optical system of the Luch setup were designed and created. To improve the interferometric pattern, the interferometer was simulated numerically by using the Fresnel software package. The parameters of the interferometer were optimized. The interferometer allows one to record interferograms of pulsed radiation at the first and second harmonics of a neodymium laser, as well as of continuous IR radiation with a short coherence length. A new method was developed for recovering the wave front by using the WinFringe software for interferograms with a reference front. Aberrations introduced by different parts and the entire optical system of the setup were measured. The wave fronts of the first and second harmonics obtained in full-scale experiments are presented. The experimental results agree with the radiation divergence measured by other methods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GQuEST Control System Resolution

GQuEST (Gravity from Quantum Entanglement of Space-Time), is a collaboration verifying a quantum gravity model by measuring holographic effects on a microscopic scale. Its interferometer apparatus filters excessive optical noise and requires a control system that can adjust the filtration to accommodate for frequency changes in the output light. We stress-test this control system by simulating filter behaviors with parameters in their outermost regimes, and we have determined a threshold that maintains precision while minimizing resource usage. These results are important for the successful operation of GQuEST's interferometer, enabling more accurate tests of quantum gravity models and thereby advancing our understanding of gravity at the quantum mechanical level.

Nguyen, David↗

A fiber-coupled heterodyne interferometric displacement sensor

Space-based interferometers and large segmented reflectors will require precision metrology with nanometer accuracy for active control systems. This paper summarizes an experimental study of an optical heterodyne interferometer with resolution of about 3 nm. Optical signals are carried to and from the interferometer by optical fibers to avoid thermally loading the reflector panels. Heterodyne detection provides far greater precision than does traditional interferometry.

Nerheim, Noble↗

Design and initial characterization of a compact, ultra high vacuum compatible, low frequency, tilt accelerometer

A compact tilt accelerometer with high sensitivity at low frequency was designed to provide low frequency corrections for the feedback signal of the Advanced Laser Interferometer Gravitational Wave Observatory active seismic attenuation system. It has been developed using a Tungsten Carbide ceramic knife-edge hinge designed to avoid the mechanical 1/f noise believed to be intrinsic in polycrystalline metallic flexures. Design and construction details are presented; prototype data acquisition and control limitations are discussed. The instrument's characterization reported here shows that the hinge is compatible with being metal-hysteresis-free, and therefore also free of the 1/f noise generated by the dislocation Self-Organized Criticality in the metal. A tiltmeter of this kind will be effective to separate the ground tilt component from the signal of horizontal low frequency seismometers, and to correct the ill effects of microseismic tilt in advanced seismic attenuation systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗