Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Imaging the inside of thick structures using cosmic rays

The authors present here a new method to image reinforcement elements inside thick structures and the results of a demonstration measurement performed on a mock-up wall built at Los Alamos National Laboratory. The method, referred to as “multiple scattering muon radiography”, relies on the use of cosmic-ray muons as probes. The work described in this article was performed to prove the viability of the technique as a means to image the interior of the dome of Florence Cathedral Santa Maria del Fiore, one of the UNESCO World Heritage sites and among the highest profile buildings in existence. Its result shows the effectiveness of the technique as a tool to radiograph thick structures and image denser object inside them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional tomographic imaging for dynamic radiation behavior study using infrared imaging video bolometers in large helical device plasma

A three-dimensional (3D) tomography system using four InfraRed imaging Video Bolometers (IRVBs) has been designed with a helical periodicity assumption for the purpose of plasma radiation measurement in the large helical device. For the spatial inversion of large sized arrays, the system has been numerically and experimentally examined using the Tikhonov regularization with the criterion of minimum generalized cross validation, which is the standard solver of inverse problems. The 3D transport code EMC3-EIRENE for impurity behavior and related radiation has been used to produce phantoms for numerical tests, and the relative calibration of the IRVB images has been carried out with a simple function model of the decaying plasma in a radiation collapse. The tomography system can respond to temporal changes in the plasma profile and identify the 3D dynamic behavior of radiation, such as the radiation enhancement that starts from the inboard side of the torus, during the radiation collapse. The reconstruction results are also consistent with the output signals of a resistive bolometer. These results indicate that the designed 3D tomography system is available for the 3D imaging of radiation. The first 3D direct tomographic measurement of a magnetically confined plasma has been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration

Myocardial perfusion imaging (MPI) using slow rotating large field of view cameras requires spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration. In vivo, MPI contains additional degrees of freedom involving unavoidable motion of the heart due to quasiperiodic beating and the effects of respiration, which can severely degrade the quality of the images. This work develops a technique for a single photon emission computed tomography (SPECT) that reconstructs the distribution of the radiotracer concentration in the myocardium using a tensor product of different sets of basis functions that approximately describe the spatiotemporal variation of the radiotracer concentration and the motion of the heart. In this study the temporal B-spline basis functions are chosen to reflect the dynamics of the radiotracer, while the intrinsic deformation and the extrinsic motion of the heart are described by a product of a discrete set of Gaussian basis functions. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it deforms due to cardiac beating, and is displaced due to respiratory motion. We find these results are compared with the conventional 4D-spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. The higher dimensional reconstruction method proposed here improves bias, yet the signal-to-noise ratio (SNR) decreases slightly due to redistribution of the counts over the cardiac-respiratory gates. Finally, there is a trade-off between the number of gates and the number of projections per gate to achieve high contrast images.

60 APPLIED LIFE SCIENCES↗

ULTRADEEP IRAC IMAGING OVER THE HUDF AND GOODS-SOUTH: SURVEY DESIGN AND IMAGING DATA RELEASE

The IRAC ultradeep field and IRAC Legacy over GOODS programs are two ultradeep imaging surveys at 3.6 and 4.5 μm with the Spitzer Infrared Array Camera (IRAC). The primary aim is to directly detect the infrared light of reionization epoch galaxies at z > 7 and to constrain their stellar populations. The observations cover the Hubble Ultra Deep Field (HUDF), including the two HUDF parallel fields, and the CANDELS/GOODS-South, and are combined with archival data from all previous deep programs into one ultradeep data set. The resulting imaging reaches unprecedented coverage in IRAC 3.6 and 4.5 μm ranging from >50 hr over 150 arcmin{sup 2}, >100 hr over 60 sq arcmin{sup 2}, to ∼200 hr over 5–10 arcmin{sup 2}. This paper presents the survey description, data reduction, and public release of reduced mosaics on the same astrometric system as the CANDELS/GOODS-South Wide Field Camera 3 (WFC3) data. To facilitate prior-based WFC3+IRAC photometry, we introduce a new method to create high signal-to-noise PSFs from the IRAC data and reconstruct the complex spatial variation due to survey geometry. The PSF maps are included in the release, as are registered maps of subsets of the data to enable reliability and variability studies. Simulations show that the noise in the ultradeep IRAC images decreases approximately as the square root of integration time over the range 20–200 hr, well below the classical confusion limit, reaching 1σ point-source sensitivities as faint as 15 nJy (28.5 AB) at 3.6 μm and 18 nJy (28.3 AB) at 4.5 μm. The value of such ultradeep IRAC data is illustrated by direct detections of z = 7–8 galaxies as faint as H{sub AB} = 28.

79 ASTRONOMY AND ASTROPHYSICS↗

Microwave Imaging Reflectometry for the study of Edge Harmonic Oscillations on DIII-D [Microwave Imaging Reflectometry (MIR) for the study of Edge Harmonic Oscillations (EHOs) on DIII-D]

Quiescent H-mode (QH) is an ELM free mode of operation in which edge-localized harmonic oscillations (EHOs) are believed to enhance particle transport, thereby stabilizing ELMs and preventing damage to the divertor and plasma facing components. Microwave Imaging Reflectometer (MIR) enabling direct comparison between the measured and simulated 2D images of density fluctuations near the edge can determine the 2D structure of density oscillation which can help to explain the physics behind EHO modes. MIR data sometimes indicates a counter-propagation between higher (n>1) and dominant (n=1) harmonics of coherent EHOs in the steep gradient regions of the pedestal. To preclude diagnostic artifacts, we have performed forward modeling that includes possible optical misalignments to show that offsets between transmitting and receiving antennas do not account for this feature. We have also simulated the non-uniform rotation of the EHO structure, which induces multiple harmonics that are properly characterized in the synthetic diagnostic. Excluding these possible explanations for the data, the counter-propagation observed in MIR data, which is not corroborated by external Mirnov coil array measurements, may be due to subtleties of the eigenmode structure, such as an inversion radius consistent with a magnetic island. Similar effects are observed in analysis of internal ECE-Imaging and BES data. Furthermore, the identification of a non-ideal structure motivates further exploration of nonlinear models of this instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional reconstruction of the size and shape of protein microcrystals using Bragg coherent diffractive imaging

Three-dimensional imaging of protein crystals during X-ray diffraction experiments opens up a range of possibilities for optimising crystal quality and gaining new insights into the fundamental processes that drive radiation damage. Obtaining this information at the appropriate lengthscales however is extremely challenging. One approach that has been recently demonstrated as a promising avenue for charactering the size and shape of protein crystals at nanometre lengthscales is Bragg Coherent Diffractive Imaging (BCDI). BCDI is a recently developed technique that is able to recover the phase of the continuous diffraction intensity signal around individual Bragg peaks. When data is collected at multiple points on a rocking curve a Reciprocal Space Map (RSM) can be assembled and then inverted using BCDI to obtain a three-dimensional image of the crystal. The first demonstration of two-dimensional BCDI of protein crystals was reported by Boutet at al., recently this work was extended to the study of radiation damage of micron-sized crystals. Here we present the first three-dimensional reconstructions of a Lysozyme protein crystal using BDI. The results are validated against RSM and TEM data and have implications for both radiation damage studies and for developing new approaches to structure retrieval from micron-sized protein crystals.

Bragg coherent diffractive imaging↗

Image registration for in situ X-ray nano-imaging of a composite battery cathode with deformation

The structural and chemical evolution of battery electrodes at the nanoscale plays an important role in affecting the cell performance. Nano-resolution X-ray microscopy has been demonstrated as a powerful technique for characterizing the evolution of battery electrodes under operating conditions with sensitivity to their morphology, compositional distribution and redox heterogeneity. In real-world batteries, the electrode could deform upon battery operation, causing challenges for the image registration which is necessary for several experimental modalities, e.g. XANES imaging. To address this challenge, this work develops a deep-learning-based method for automatic particle identification and tracking. This approach was not only able to facilitate image registration with good robustness but also allowed quantification of the degree of sample deformation. The effectiveness of the method was first demonstrated using synthetic datasets with known ground truth. The method was then applied to an experimental dataset collected on an operating lithium battery cell, revealing a high degree of intra- and interparticle chemical complexity in operating batteries.

25 ENERGY STORAGE↗

SU-E-J-27: Shifting Multiple EPID Imager Layers to Improve Image Quality and Resolution in MV CBCT

Purpose: Vertical stacking of four conventional EPID layers can improve DQE for MV-CBCT applications. We hypothesize that shifting each layer laterally by half a pixel relative to the layer above, will improve the contrast-to-noise ratio (CNR) and image resolution. Methods: For CNR assessment, a 20 cm diameter digital phantom with 8 inserts is created. The attenuation coefficient of the phantom is similar to lung at the average energy of a 6 MV photon beam. The inserts have attenuations 1, 2…8 times of lung. One of the inserts is close to soft tissue, resembling the case of a tumor in lung. For resolution assessment, a digital phantom featuring a bar pattern is created. The phantom has an attenuation coefficient similar to soft tissue and the bars have an attenuation coefficient of calcium sulfate. A 2 MeV photon beam is attenuated through these phantoms and hits each of the four stacked detector layers. Each successive layer is shifted by half a pixel in the x only, y only, and x and y (combined) directions, respectively. Blurring and statistical noise are added to the projections. Projections from one, two, three and four layers are used for reconstruction. CNR and image resolution are evaluated and compared. Results: When projections from multiple layers are combined for reconstruction, CNR increases with the number of layers involved. CNR in reconstructions from two, three and four layers are 1.4, 1.7 and 1.99 times that from one layer. The resolution from the shifted four layer detector is also improved from a single layer. In a comparison between one layer versus four layers in this preliminary study, the resolution from four shifted layers is at least 20% better. Conclusion: Layer-shifting in a stacked EPID imager design enhances resolution as well as CNR for half scan MV-CBCT. The project described was supported, in part, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

High Miller-Index Germanium Crystals For High-Energy X-ray Imaging Applications

Near-normal-incidence bent crystals are widely used for x-ray imaging applications. Advantages include high collection solid angle and potentially high efficiency for narrow-band sources, while disadvantages include relatively large (several Å) interatomic spacings and a limited number of suitable matches between a crystal 2d value and an integral multiple of useful emission line wavelengths. The disadvantages become more significant at x-ray energies >10 keV. The former disadvantage can be mitigated by using high-order reflections from crystal planes having low Miller indices, but both disadvantages can be mitigated by using low-order reflections from crystal planes having high Miller indices. We report here on integrated reflectivity measurements we performed of Ge (15,7,7) (2d=0.6296 Å), a candidate for imaging Ru He-α (θ(B)=87°). We find good agreement with calculations, and the data show a multitude of closely spaced reflections with slightly different Bragg angles including a fifth-order reflection of Ge (3,1,1) that has comparable reflectivity. This demonstrates that arbitrary choices of Miller indices in Ge crystals can be used to fine-tune Bragg angles for near-normal-incidence x-ray imaging at tens of kiloelectron volt x-ray energies with minimal lower-energy contamination from lower-order reflections, and that existing calculational tools can be used to reliably estimate integrated reflectivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PET Imaging Agents (FES, FFNP, and FDHT) for Estrogen, Androgen, and Progesterone Receptors to Improve Management of Breast and Prostate Cancers by Functional Imaging

Many breast and prostate cancers are driven by the action of steroid hormones on their cognate receptors in primary tumors and in metastases, and endocrine therapies that inhibit hormone production or block the action of these receptors provide clinical benefit to many but not all of these cancer patients. Because it is difficult to predict which individuals will be helped by endocrine therapies and which will not, positron emission tomography (PET) imaging of estrogen receptor (ER) and progesterone receptor (PgR) in breast cancer, and androgen receptor (AR) in prostate cancer can provide useful, often functional, information on the likelihood of endocrine therapy response in individual patients. This review covers our development of three PET imaging agents, 16α-[ 18 F]fluoroestradiol (FES) for ER, 21-[ 18 F]fluoro-furanyl-nor-progesterone (FFNP) for PgR, and 16β-[ 18 F]fluoro-5α-dihydrotestosterone (FDHT) for AR, and the evolution of their clinical use. For these agents, the pathway from concept through development tracks with an emerging understanding of critical performance criteria that is needed for successful PET imaging of these low-abundance receptor targets. Progress in the ongoing evaluation of what they can add to the clinical management of breast and prostate cancers reflects our increased understanding of these diseases and of optimal strategies for predicting the success of clinical endocrine therapies.

60 APPLIED LIFE SCIENCES↗

Toward Autonomous Field Inspection of CSP Collectors With a Polarimetric Imaging Drone

We developed a polarimetric imaging drone to perform field inspections of heliostats and carried out field tests at Sandia’s National Solar Thermal Test Facility (NSTTF). The preliminary results show that Degree of Linear Polarization (DOLP) and Angle of Polarization (AOP) images greatly enhanced the edge detection results compared with the conventional visible images, supporting fast and accurate detection of heliostat mirror edges and cracks. The system holds the promise to enable future automated detection of heliostats optical errors and mirror defects.

14 SOLAR ENERGY↗

Spaceborne Imaging Radar-C: An Advanced Imaging Radar Studied the Earth

None given. From Intro: The U.S. launched the most sophisticated imaging radar ever on-board the space shuttle Endeavor twice within a year as part of NASA's Mission to Planet Earth Program. Survey image products were available within three months following each of the missions. Most important aspect of SIR-C products is that the images are calibrated.The interferometry experiment conducted during the second flight clearly demonstrated that global high-resolution topographic maps are within the reach of current SAR technology.

SIR-C imaging radar MAPS synthetic radar SAR SRL S↗

Guide for Atomic Force Microscopy Image Analysis To Discriminate Heteroatoms in Aromatic Molecules [A Guide for AFM Image Analysis To Discriminate Heteroatoms in Aromatic Molecules]

Heteroatoms are essential for functional groups in organic structures and are complementary to hydrocarbon molecules in reactivities and properties. However, it is still a challenge to quickly identify heteroatoms with only non-contact atomic force microscopy (nc-AFM) to resolve chemical structures in complex unknown mixtures. This study aimed to understand the effect of elemental types on the contrast of atomic force microscopy (AFM) images using a few selected model heterocycles, including dibenzothiophene (DBT), acridine (ACR), and carbazole (CBZ). We identified several features that can be used to find common heteroatoms (S and N) and discriminated them from carbon atoms (C) using nc-AFM images alone. The mechanism of the atom and bond contrast was studied with image simulations and was found to be mostly correlated to van der Waals radii, but other factors, such as bonding geometry, electron density, and substrate interaction, need to be considered. As a result, this work will allow for rapid identification of these common heteroatoms in petroleum with AFM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗