Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Unimodal Imaging of Monovalent Metal-Chelator Complexes and Lipids by MALDI Imaging Mass Spectrometry

Careful regulation of monovalent metal ions (M + ) is necessary to maintain a functional cellular system. Of these ions, appropriate sodium (Na + ) and potassium (K + ) concentrations are particularly integral for electrochemical signaling, as well as the secondary transport of nutrients and waste. Dysregulation of M + homeostasis can disrupt these mechanisms, potentially influencing the metabolism of downstream biomolecules such as lipids. Thus, the relationship between M + abundances and related biomolecular distributions must be elucidated to better understand the physiology of healthy and disordered tissues. Traditional techniques for imaging biological metal distributions include SIMS, LA-ICP-MS, and XRF; however, these capabilities are limited to elemental analysis or the analysis of molecular fragments and must be paired with other modalities to visualize distributions of more complex biomolecules within the same or similar samples. Conversely, matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) is a powerful tool often used for mapping such biomolecular distributions, but current methods are unable to detect metals within tissue. This study illustrates a novel methodology that adds metal detection to the MALDI IMS repertoire through which the simultaneous detection of M + metals and lipids is achievable. Using a robotic sprayer for homogeneous application, on-tissue deposition of the chelator deferiprone (DEF) enables subsequent detection of the ionizable metal-chelator complex by MALDI without hindering lipid detection. Our work provides proof-of-concept data for the simultaneous detection of K + , Na + , and intact lipids using MALDI IMS.

59 BASIC BIOLOGICAL SCIENCES↗

Improved Quantitative Analysis of Ion Mobility Spectrometry by Chemometric Multivariate Calibration

Traditional peak-area calibration and the multivariate calibration methods of principle component regression (PCR) and partial least squares (PLS), including unfolded PLS (U-PLS) and multi-way PLS (N-PLS), were evaluated for the quantification of 2,4,6-trinitrotoluene (TNT) and cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) in Composition B samples analyzed by temperature step desorption ion mobility spectrometry (TSD-IMS). The true TNT and RDX concentrations of eight Composition B samples were determined by high performance liquid chromatography with UV absorbance detection. Most of the Composition B samples were found to have distinct TNT and RDX concentrations. Applying PCR and PLS on the exact same IMS spectra used for the peak-area study improved quantitative accuracy and precision approximately 3 to 5 fold and 2 to 4 fold, respectively. This in turn improved the probability of correctly identifying Composition B samples based upon the estimated RDX and TNT concentrations from 11% with peak area to 44% and 89% with PLS. This improvement increases the potential of obtaining forensic information from IMS analyzers by providing some ability to differentiate or match Composition B samples based on their TNT and RDX concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric Pressure Chemical Ionization Sources Used in The Detection of Explosives by Ion Mobility Spectrometry

Explosives detection is a necessary and wide spread field of research. From large shipping containers to airline luggage, numerous items are tested for explosives every day. In the area of trace explosives detection, ion mobility spectrometry (IMS) is the technique employed most often because it is a quick, simple, and accurate way to test many items in a short amount of time. Detection by IMS is based on the difference in drift times of product ions through the drift region of an IMS instrument. The product ions are created when the explosive compounds, introduced to the instrument, are chemically ionized through interactions with the reactant ions. The identity of the reactant ions determines the outcomes of the ionization process. This research investigated the reactant ions created by various ionization sources and looked into ways to manipulate the chemistry occurring in the sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contribution of Lake-Effect Snow to the Catskill Mountains Snowpack

Meltwater from snow that falls in the Catskill Mountains in southern New York contributes to reservoirs that supply drinking water to approximately nine million people in New York City. Using the NOAA National Ice Centers Interactive Multisensor Snow and Ice Mapping System (IMS) 4km snow maps, we have identified at least 32 lake-effect (LE) storms emanating from Lake Erie andor Lake Ontario that deposited snow in the CatskillDelaware Watershed in the Catskill Mountains of southern New York State between 2004 and 2017. This represents a large underestimate of the contribution of LE snow to the Catskills snowpack because many of the LE snowstorms are not visible in the IMS snow maps when they travel over snow-covered terrain. Most of the LE snowstorms that we identified originate from Lake Ontario but quite a few originate from both Erie and Ontario, and a few from Lake Erie alone. Using satellite, meteorological and reanalysis data we identify conditions that contributed to LE snowfall in the Catskills. Clear skies following some of the storms permitted measurement of the extent of snow cover in the watershed using multiple satellite sensors. IMS maps tend to overestimate the extent of snow compared to MODerate resolution Imaging Spectroradiometer (MODIS) and Landsat-derived snow-cover extent maps. Using this combination of satellite and meteorological data, we can begin to quantify the important contribution of LE snow to the Catskills Mountain snowpack. Changes that are predicted in LE snowfall from the Great Lakes could impact the distribution of rain vs snow in the Catskills which may affect future reservoir operations in the NYC Water Supply System.

Lake Ontario↗

Pedestal Hazard Abatement and Soil Removal Construction Completion Report for Launch Complex 34, Solid Waste Management Unit CC054, Cape Canaveral Space Force Station, Florida

This Construction Completion Report summarizes the activities associated with implementation of an interim measure (IM) for hazard abatement of the Launch Pedestal and soil removal at Launch Complex 34 (LC34), Cape Canaveral Space Force Station, Florida. The purpose of the hazard abatement IM was to mitigate any continuing source of contamination associated with residual paint on the Launch Pedestal that contained polychlorinated biphenyls (PCBs). Sampling determined that residual PCB concerns were limited to the steel elements on the top-side of the Pedestal, which included the torus ring, feed pipe, down pipes, pipe straps and shields, remaining steel cover plates and bolts, and railing support steel. The IM also mitigated the potential spread of contamination to surrounding areas by removing fallen metal fragments from the concrete launch pad, as well as soil from trenches on the launch pad where PCB-containing paint chips may have accumulated prior to or during Pedestal hazard abatement activities.

Complex 34↗

Impact of environmental backgrounds on atmospheric monitoring of nuclear explosions

Radionuclide monitoring for nuclear explosions includes measuring radioactive aerosol and noble gas concentrations in the atmosphere. The International Monitoring System (IMS) of the Comprehensive Nuclear Test Ban Treaty (CTBT) has made such measurements for decades, revealing much about how atmospheric radioactivity impacts the sensitivity of the network. For example, civilian emissions of radioiodine make a substantial regional impact, but a minor global impact, while civilian radioxenon emissions create major regional and complex global impacts. This example statement is strongly influenced by the minimum signal level anticipated to be interesting. The original design of the IMS anticipated relatively large signal levels, and the accomplished IMS network substantially meets or exceeds the sensitivity needed to detect those signal levels. Much lower signal levels can be motivated, which could require reconsideration of station sensitivity. Using measured and simulated background concentrations, various possible desired signal levels, and an innovative anomaly threshold, maps of sensitivity and a station ranking are developed for current and future stations. These provide a strong motivation for additional experimentation to learn about sources and the potential plusses of new technology.

Eslinger, Paul W.↗

Enhancing glycan isomer separations with metal ions and positive and negative polarity ion mobility spectrometry-mass spectrometry analyses

Glycomics has become an increasingly important field of research since glycans play critical roles in biology processes ranging from molecular recognition and signaling to cellular communication. Glycans often conjugate with other biomolecules such as proteins and lipids, and alter their properties and functions, so understanding the effect glycans have on cellular systems is essential. However the analysis of glycans is extremely difficult due to their complexity and structural diversity (i.e., the number and identity of monomer units, and configuration of their glycosidic linkages and connectivities). In this work, we coupled ion mobility spectrometry with mass spectrometry (IMS-MS) to characterize glycan standards and biologically important isomers of synthetic αGal-containing O-glycans including glycotopes of the protozoan parasite Trypanosoma cruzi, which is the causative agent of Chagas disease. IMS-MS results showed significant differences for the glycan structural isomers when analyzed in positive and negative polarity and complexed with different metal cations. These results suggest specific metal ions or ion polarities could be used to target and baseline separate glycan isomers of interest with IMS-MS.

Environmental Molecular Sciences Laboratory↗

Detecting and Removing Data Artifacts in Hadamard Transform Ion Mobility-Mass Spectrometry Measurements

Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that both fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and appear as noise in downstream processing of the data. To address this problem, we have developed a novel algorithm that discovers and eliminates data artifacts. The algorithm uses knowledge of the true signal peaks derived from the encoded data and allows for both artifacts and noise to be removed with high confidence, decreasing the likelihood of false identifications in subsequent data processing. The result is that IMS-MS can be applied to increase measurement sensitivity while avoiding artifacts that have previously limited its utility.

47 OTHER INSTRUMENTATION↗

Aerosol Vacuum-Assisted Plasma Ionization (Aero-VaPI) Coupled to Ion Mobility-Mass Spectrometry

In this communication, we report on the real-time analysis of organic aerosol particles by Vacuum-assisted Plasma Ionization-Mass Spectrometry (Aero-VaPI-MS) using a home-built VaPI ion source coupled to a Synapt G2-S HDMS ion mobility-mass spectrometry (IM-MS) system. Standards of organic molecules of interest in prebiotic chemistry were used to generate aerosols. Monocaprin and decanoic acid aerosol particles were successfully detected in both the positive and negative ion modes, respectively. A complex aerosol mixture of different sizes of polymers of L-malic acid was also examined through ion mobility (IM) separations, resulting in the detection of polymers of up to eight monomeric units. This noncommercial plasma ion source is proposed as a low cost alternative to other plasma ionization platforms used for aerosol analysis, and a higher-performance alternative to more traditional aerosol mass spectrometers. VaPI provides robust online ionization of organics in aerosols without extensive ion activation, with the coupling to IM-MS providing higher peak capacity and excellent mass accuracy. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical Characterization of High-Temperature Carbon Fiber-Polyphenylene Sulfide Composites for Large Area Extrusion Deposition Additive Manufacturing

Additive manufacturing (AM) is evolving from rapid prototyping to production of structural components. The widespread application of AM demands a high level of mechanical performance from these components, and it is therefore essential to improve feedstock material in order to meet these mechanical expectations. However, compared to traditional manufacturing techniques, the mechanical properties of AM materials and their resulting components are not well understood. In this study, we investigated the processability, microstructure, and mechanical performance of twin-screw compounded short carbon fiber reinforced polyphenylene sulfide (PPS) pellets as a feedstock material for big area AM (BAAM). The performance of the AM components was compared to that of traditional processing methods, namely injection molding (IM) and extrusion-compression molding (ECM). It was found that the AM composites exhibited 118% lower tensile strength and 55% lower tensile modulus when compared to traditional injection molding composite specimens; however, AM composites exhibited comparable properties to ECM composites. This response was attributed to highly aligned fibers in IM and AM samples. However, the AM composites contained porosity (15.5% volume), which reduced their mechanical properties in comparison to ECM composites. Finally, the IM process showed the maximum amount of fiber attrition with minimum porosity (0.007% volume), while the ECM process exhibited the least fiber attrition with 4.3% volume porosity.

36 MATERIALS SCIENCE↗

Efficient electrocatalytic conversion of CO 2 to ethanol enabled by imidazolium-functionalized ionomer confined molybdenum phosphide

An effective electrochemical carbon dioxide reduction reaction (eCO 2 RR) requires the discovery of a catalytic system that is highly active and selective for multi-carbon products together with superior CO 2 diffusion at a catalyst layer to minimize the reduction barriers. Here, we found a catalytic system that uses molybdenum phosphide (MoP) nanoparticles covered by imidazolium-functionalized ionomer (Im) that promotes CO 2 diffusion at the catalyst layer toward the catalyst surface, where CO 2 is reduced to ethanol (C 2 H 5 OH). The electrochemical results with the MoP-Im co-catalyst show a C 2 H 5 OH production Faradaic efficiency and a cathodic energy efficiency of 77.4% and 63.3%, respectively, at a potential as low as - 200 mV vs. RHE. The electrochemical experiments along with our physicochemical characterizations indicate that the Im improves CO 2 diffusion and balances water content resulting in a higher CO 2 -to-water ratio at the catalyst layer and fine-tunes the electronic properties of Mo atoms at the MoP surface. Finally, in-situ Raman spectroscopy reveals that a high number of adsorbed *CO intermediates on the surface and a higher binding strength of *CO intermediates on the Mo surface sites in the presence of imidazolium molecules are the main reasons for a superior C-C coupling and thereby the improved C 2 H 5 OH formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amyloid formation and disaggregation of {alpha}-synuclein and its tandem repeat ({alpha}-TR)

Research highlights: {yields} Formation of the {alpha}-synuclein amyloid fibrils by [BIMbF{sub 3}Im]. {yields} Disaggregation of amyloid fibrils by epigallocatechin gallate (EGCG) and baicalein. {yields} Amyloid formation of {alpha}-synuclein tandem repeat ({alpha}-TR). -- Abstract: The aggregation of {alpha}-synuclein is clearly related to the pathogenesis of Parkinson's disease. Therefore, detailed understanding of the mechanism of fibril formation is highly valuable for the development of clinical treatment and also of the diagnostic tools. Here, we have investigated the interaction of {alpha}-synuclein with ionic liquids by using several biochemical techniques including Thioflavin T assays and transmission electron microscopy (TEM). Our data shows a rapid formation of {alpha}-synuclein amyloid fibrils was stimulated by 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [BIMbF{sub 3}Im], and these fibrils could be disaggregated by polyphenols such as epigallocatechin gallate (EGCG) and baicalein. Furthermore, the effect of [BIMbF{sub 3}Im] on the {alpha}-synuclein tandem repeat ({alpha}-TR) in the aggregation process was studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A generic method for interfacing IEDs using low voltage interfaces to real-time simulators with hardware in the loop

This study presents an interface method (IM) to interconnect real-time simulators (RTSs) without amplifiers for different intelligent electronic devices (IEDs), such as protective relays, smart meters, and other devices. It is a significant topic for the power systems protection community because there are many protection devices with different requirements. These protection devices have pinouts that measure bus voltages/currents and breaker pole states and generate trip/close pulse signals. Most of the emulation test beds with RTSs and HIL need amplifiers to connect IEDs from different product manufacturers because the low-voltage interface levels are not available in some instruction manuals. Additionally, commercial amplifiers have cutoff frequency limitations and have an excessive cost when several IEDs are wired onto test beds. Then, the validation of protection and control systems with RTSs and IEDs in the loop from different vendors without amplifiers results in an unfeasible alternative. In this paper, the IM was based on using an interface box, power source, and RTS to identify IED inputs/outputs. Here, the sequence to recognize IED pinouts and calculate the current/voltage scaling factors is described. The IM was validated satisfactorily with RTS and a protection device (with unknown pinouts) in the loop.

42 ENGINEERING↗

Single-Isocenter Frameless Intensity-Modulated Stereotactic Radiosurgery for Simultaneous Treatment of Multiple Brain Metastases: Clinical Experience

Purpose: To describe our clinical experience using a unique single-isocenter technique for frameless intensity-modulated stereotactic radiosurgery (IM-SRS) to treat multiple brain metastases. Methods and Materials: Twenty-six patients with a median of 5 metastases (range, 2-13) underwent optically guided frameless IM-SRS using a single, centrally located isocenter. Median prescription dose was 18 Gy (range, 14-25). Follow-up magnetic resonance imaging (MRI) and clinical examination occurred every 2-4 months. Results: Median follow-up for all patients was 3.3 months (range, 0.2-21.3), with 20 of 26 patients (77%) followed up until their death. For the remaining 6 patients alive at the time of analysis, median follow-up was 14.6 months (range, 9.3-18.0). Total treatment time ranged from 9.0 to 38.9 minutes (median, 21.0). Actuarial 6- and 12-month overall survivals were 50% (95% confidence interval [C.I.], 31-70%) and 38% (95% C.I., 19-56%), respectively. Actuarial 6- and 12-month local control (LC) rates were 97% (95% C.I., 93-100%) and 83% (95% C.I., 71-96%), respectively. Tumors {<=}1.5 cm had a better 6-month LC than those >1.5 cm (98% vs. 90%, p = 0.008). New intracranial metastatic disease occurring outside of the treatment volume was observed in 7 patients. Grade {>=}3 toxicity occurred in 2 patients (8%). Conclusion: Frameless IM-SRS using a single-isocenter approach for treating multiple intracranial metastases can produce clinical outcomes that compare favorably with those of conventional SRS in a much shorter treatment time (<40 minutes). Given its faster treatment time, this technique is appealing to both patients and personnel in busy clinics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source Term Estimates of Radioxenon Released from the BaTek Medical Isotope Production Facility Using External Measured Air Concentrations

Abstract Batan Teknologi (BaTek) operates an isotope production facility in Serpong, Indonesia that supplies 99mTc for use in medical procedures. Atmospheric releases of Xe-133 in the production process at BaTek are known to influence the measurements taken at the closest stations of the International Monitoring System (IMS). The purpose of the IMS is to detect evidence of nuclear explosions, including atmospheric releases of radionuclides. The xenon isotopes released from BaTek are the same as those produced in a nuclear explosion, but the isotopic ratios are different. Knowledge of the magnitude of releases from the isotope production facility helps inform analysts trying to decide whether a specific measurement result came from a nuclear explosion. A stack monitor deployed at BaTek in 2013 measured releases to the atmosphere for several isotopes. The facility operates on a weekly cycle, and the stack data for June 15-21, 2013 show a release of 1.84E13 Bq of Xe-133. Concentrations of Xe-133 in the air are available at the same time from a xenon sampler located 14 km from BaTek. An optimization process using atmospheric transport modeling and the sampler air concentrations produced a release estimate of 1.88E13 Bq. The same optimization process yielded a release estimate of 1.70E13 Bq for a different week in 2012. The stack release value and the two optimized estimates are all within 10 percent of each other. Weekly release estimates of 1.8E13 Bq and a 40 percent facility operation rate yields a rough annual release estimate of 3.7E13 Bq of Xe-133. This value is consistent with previously published estimates of annual releases for this facility, which are based on measurements at three IMS stations. These multiple lines of evidence cross-validate the stack release estimates and the release estimates from atmospheric samplers.

atmospheric modeling↗

Improved performance comparisons of radioxenon systems for low level releases in nuclear explosion monitoring

The Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests and mandates development of verification measures to detect treaty violations. One verification measure is detection of radioactive xenon isotopes produced in the fission of actinides. The International Monitoring System (IMS) currently deploys automated radioxenon systems that can detect four radioxenon isotopes. Radioxenon systems with lower detection limits are currently in development. Historically, the sensitivity of radioxenon systems was measured by the minimum detectable concentration for each isotope. In this paper we analyze the response of radioxenon systems using rigorous metrics in conjunction with hypothetical representative releases indicative of an underground nuclear explosion instead of using only minimum detectable concentrations. Our analyses incorporate the impact of potential spectral interferences on detection limits and the importance of measuring isotopic ratios of the relevant radioxenon isotopes in order to improve discrimination from background sources particularly for low-level releases. To provide a sufficient data set for analysis, hypothetical representative releases are simulated every day from the same location for an entire year. The performance of three types of samplers are evaluated assuming they are located at 15 IMS radionuclide stations in the region of the release point. The performance of two IMS-deployed samplers and a next-generation system is compared with proposed metrics for detection and discrimination using representative releases from the nuclear test site used by the Democratic People’s Republic of Korea.

Haas, Derek A.↗

Radionuclide measurements of the international monitoring system

The International Monitoring System (IMS) is a unique global network of sensors, tuned to measure various phenomenology, with the common goal of detecting a nuclear explosion anywhere in the world. One component of this network collects measurements of radioactive particulates and gases (collectively known as radionuclides) present in the atmosphere; through this, compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT) can be verified. The radionuclide sub-network consists of 120 sensors across 80 locations, supported by 16 measurement laboratories. All radionuclide stations make use of a form of γ-ray spectroscopy to measure radionuclides from samples; this remains largely unchanged since the network was first established 25 years ago. Advances in sampling and spectroscopy systems can yield improvements to the sensitivity of the network to detect a nuclear explosion. This paper summarises the status of the IMS radionuclide network, the current suite of technology used and reviews new technology that could enhance future iterations, potentially improving the verification power of the IMS.

Goodwin, Matthew A.↗