Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection of Grid-Signal Distortions Using the Spectral Correlation Function

This study proposes a novel method for signal detection and feature extraction based on the spectral correlation function, enabling improved characterization of grid-signal distortions. Our approach differs from existing treatments of signal distortion in its analysis of the varied spectral content of signals observed in real-world scenarios. The method we propose has state-of-the-art discriminative power that provides meaningful and understandable characterizations of various grid events and anomalies. In conclusion, to validate the approach, we use real world data from the Grid Event Signature Library, which is maintained jointly by Oak Ridge National Laboratory and Lawrence Livermore National Laboratory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Future Electric Power Industry and Grids—Now What Again is Our Destination?

Having a vision that others agree to support and work toward is highly desirable but hard to achieve. We seem to lack a common and shared understanding of the vision—or worse, multiple visions (vivid mental images or documented statements) with varying areas of focus and details: • some appear to be similar but have differing underlying goals and characteristics, or • some reflect differing viewpoints as to effects on various stakeholders. These desirable and undesirable situations apply to realizing visions for enterprise and industry, including the electricity sector. Multiple industry stakeholder groups have developed goals, industry vision statements, and characterizations of the future. The viewpoints are promoted, discussed, refined by their stakeholder group, and often published to promote broad understanding and to inform or influence others. The GridWise Architecture Council asked itself how well-aligned these characterizations of the future are. If these publications collectively set the overall direction for the industry, it is useful to identify their answers to questions such as, where is the electric industry headed, guided by what objectives, and with what role(s) for the customers, electric utilities, and other stakeholders? Are these goals, visions, and future states moving toward a common vision, do they provide value for the stakeholders, and are they likely to meet the objective stated? This paper addresses these questions via an assessment and characterization of a sampling of stakeholder groups’ publicly available vision and future state reports for the electricity industry. Identified electric power grid architectural topic areas needing further work are described, along with GridWise Architecture Council analysis and observation, potential collaborative work efforts, and suggested next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of the polygeneration approach in wastewater treatment plants for enhanced energy efficiency and green hydrogen/ammonia production

Wastewater treatment plants (WWTPs) offer opportunities to optimize resource utilization and enhance energy efficiency. Here, this study provides a comprehensive analysis of using the polygeneration approach in WWTPs to reduce grid energy dependence, optimize energy distribution, and utilize surplus energy for hydrogen (H 2 ) and ammonia (NH 3 ) production. Several models were employed, including photovoltaic (PV) cells, parabolic trough collectors (PTCs), steam methane reforming, and polymer electrolyte membranes, to assess the feasibility of this approach. Three scenarios were evaluated and compared: Scenario 1 (Baseline) represents the current situation, Scenario 2 maximizes the Net Present Value (NPV), and Scenario 3 minimizes NH 3 production costs. Real data from As-Samra WWTP in Jordan was used to accurately assess the feasibility of each scenario. The results show that Scenario 2 offers the highest profitability and efficiency, with a NPV of 87.48 million USD and an annual NH 3 production of 15,417 tons, reducing both grid dependency and biogas fuel consumption. Both Scenarios 2 and 3 demonstrate the ability to meet thermal demands efficiently while generating significant revenue from NH 3 production. Scenario 3, in particular, achieves competitive H 2 and NH 3 production costs. Environmentally, Scenario 2 significantly reduces annual greenhouse gas emissions by 12.66 kilotons of CO 2eq , with near-zero carbon intensity for thermal energy due to solar reliance. In conclusion, the polygeneration approach offers a promising pathway for WWTPs to achieve greater sustainability, economic gains, and reduced environmental impact, providing valuable insights for decision-makers.

42 ENGINEERING↗

Resource assessment of ocean thermal energy conversion in Puerto Rico and U.S. Virgin Islands

Island communities often struggle to establish and maintain traditional electric grids and are therefore heavily reliant on costly imported fossil fuels. In the case of Puerto Rico, these challenges are enhanced by extreme weather and other natural hazards that threaten the local electricity generation and transmission infrastructure. Ocean thermal energy conversion (OTEC) could play an important role in establishing a more resilient electrical grid in the region. Here, in this study, a detailed analysis is conducted to characterize the ocean thermal resource and power potential of OTEC in Puerto Rico based on a 14-year dataset of modeled ocean temperature. The assessment considers seasonal and interannual variability in the region's thermal resource and examines the operational limitations associated with minimal thermal gradients required to run a typical OTEC heat engine. Notably, the local thermal resource is found to be sensitive to El Niño-Southern Oscillation (ENSO) climate patterns, with La Niña conditions linked to greater OTEC power availability. Seven areas of opportunity are identified based on their resource potential and proximity to existing electrical distribution lines, including two that could benefit the nearby U.S. Virgin Islands. The greatest OTEC power potential is observed to the south of the main island of Puerto Rico in the Caribbean Sea with an estimated capacity of 138 MW for a plant pumping cold water from a depth of 1,000 m, or the equivalent amount of electricity required to power 219,000 households.

OTEC↗

Scalable and Secure Power Outage Data Reporting: A Hexagonal Geospatial Approach

Power outages disrupt critical infrastructure and cause billions of dollars in economic losses annually in the United States. Accurate and granular outage reporting is vital for effective restoration and mitigation. This paper examines the integration of the Hexagonal Hierarchical Geospatial Indexing System (H3) to enhance power outage reporting, leveraging its uniform grid structure, scalable resolutions, and support for privacy-preserving analysis. Using high-resolution LandScan Global population data and K-anonymization techniques, this work achieves a balance between data granularity and privacy. Results show that lower privacy thresholds (e.g., K-anonymity = 2) enable higher resolution, while stricter thresholds (e.g., >15 people per hex) reduce granularity, potentially affecting localized responses. State-and county-level resolution case studies demonstrate H3’s adaptability and the trade-offs between precision and privacy. The proposed H3-based framework offers a scalable and efficient solution for geospatial data integration within the energy sector, such as outage data, aiding utilities and regulators in improving resilience and response efforts, particularly in disaster-prone regions.

Ahmad, Nasir [ORNL] (ORCID:0000000150677368)↗

Climate Extremes and Variability Surrounding Chesapeake Bay: Past, Present, and Future

Measures of extreme climate variability around Chesapeake Bay have changed over the past century (1895–2014), resulting in the need to establish new baselines for understanding future change. Here, observed climate variability is compared with Coupled Model Intercomparison Project fifth assessment climate models to evaluate ensemble model skill in this region. Observed trends include annual and seasonal declines in the percentage of cold days. Similarly, increases in the annual and seasonal percentages of warm days occurred in all seasons of the North Chesapeake (>38.2°N) but were only significant in spring and summer in the South (<38.2°N) demonstrating regional differences even at local scales. Precipitation intensity increased over the past century. Models using emissions scenarios RCP4.5 and 8.5 project these trends will continue, though they have little skill in precipitation extremes. Pacific and Atlantic climate modes are generally more correlated with climate extremes than mean temperature and precipitation suggesting potential predictability in the synoptic patterns underlying the extremes. However, they also drive the need for time series at least 60-years long for establishing climate trends. This local analysis differs from regional, state level, and local 2.5° × 3.75° grid analyses, highlighting the importance of local climate assessments that consider topographic and regional weather patterns.

54 ENVIRONMENTAL SCIENCES↗

Interregional Electricity Transmission in the United States: Realized Savings and Opportunities for Increased Value, 2014 to 2023

Interregional electricity trade in the United States reduces total energy costs, but falls short of maximizing the economic potential of existing transmission infrastructure. This analysis of thirty-two U.S. electricity system interfaces crossing grid or market seams finds an average achieved cost savings of at least $1,226 million per year. This positive impact is offset by an average annual cost of uneconomic interchange of $551 million. Additional value of at least $238 million per year could be enabled by increasing utilization. Notably, uneconomic flows and low utilization rates can persist even when the price spread between regions is large. These conclusions are derived from historical (2014–2023) data on the magnitude and direction of interregional price spreads, the magnitude and direction of net energy transfers, and how these variables coincide, but do not account for all system constraints. These findings motivate the development and deployment of solutions that improve interregional transmission operations, in parallel with robust transmission infrastructure planning. JEL Classification: Q40 Energy: General

Q40 Energy: General↗

Modeling Capabilities to Quantify the Benefits of DERMS (Cooperative Research and Development Final Report)

The funds-in under the CRADA will fund a team of National Renewable Energy Laboratory (NREL) researchers to participate in Energy I-Corps (formerly known as Lab-Corps). Energy I-Corps pairs teams of researchers with industry mentors for an intensive two-month training where the researchers define technology value propositions, conduct customer discovery interviews, and develop viable market pathways for their technologies. FedIMPACT, LLC and its affiliate IP Group, Inc., will evaluate the work completed at Energy I-Corps to determine whether it would like to pursue further commercialization and development of related technologies and background intellectual property.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Studies for Pumped Storage Hydropower (Final CRADA Report)

The research focused on estimating the value of various services and contributions that pumped storage hydropower (PSH) provides to the grid, especially in locations characterized by high penetration of variable renewable energy resources. Under this CRADA, the Participant provided the Contractors with non-proprietary data and information on the proposed Banner Mountain PSH project that describe project’s technoeconomic and environmental characteristics, planned market and business models, and other relevant information necessary to describe the proposed project and its planned operations. The Contractors analyzed this information and performed various technoeconomic studies to estimate the value of different services and contributions that PSH project could provide to the grid. The outcome of this CRADA was a detailed technoeconomic analysis conducted in a comprehensive cost–benefit and decision analysis framework.

13 HYDRO ENERGY↗

Study of Storage Requirements and Costs for Shaping Renewables and Nuclear Energy (FY23 Summary Report)

To decarbonize electricity generation primarily by using wind and solar resources, it is likely that additional low (or zero) carbon dioxide (CO 2 ) alternatives will be required for ensuring a reliable electricity supply. This study extends the work and modeling framework that we consolidated in FY 2022, by assessing the zero-CO 2 pathways of a Texas power system in which the availability of variable renewable energy (VRE), nuclear energy, and energy storage types (i.e., battery and thermal energy storage [TES]) are considered the sole resources available for expansion. Using the Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON) frameworks, this study investigates the market of two nuclear energy technologies (i.e., large light-water reactors [LWRs] and LWR-type small modular reactors [SMRs]) under two plausible storage coupling scenarios (i.e., electric coupling and direct thermal coupling). We also explore optimal environments for nuclear energy deployment, and identify key performance characteristics that make nuclear energy economically viable in areas with significant intermittent energy sources. Our analysis encompasses 24 cases. We model the least-cost grid systems, highlight the potential for a coupled LWR-TES approach, and utilize SMRs to achieve deep decarbonization in an affordable, technically feasible manner. We also examine seasonal variations in balancing electricity supply and demand, and account for varying performance, costs, and grid constraints. Overall, the findings of our modeling afford valuable insights for supporting future technology investment decisions in the energy sector.

25 ENERGY STORAGE↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable Truck Charging Demand Simulation for Cost-Optimized Infrastructure Planning

This project developed a scalable, high-resolution model to simulate medium- and heavy-duty (MHD) electric truck charging demand and assess its impact on grid infrastructure. Using generative modeling, simulation, and cost optimization, the project delivered an end-to-end software pipeline and a library of 96 real-world scenarios for the Dallas–Houston megaregion. We demonstrated a modular architecture for transportation and grid modeling, implemented cost-optimized infrastructure planning methods, and quantified grid capital, operational, and environmental costs across a wide range of truck electrification scenarios. The results have been adopted by major utility stakeholders and contributed to regional planning efforts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Analysis of a Thermophotovoltaic Integrated Self-Powered Furnace

This work investigates the energy efficiency and carbon reduction potential of self-powered residential building heating equipment using a thermodynamic modeling approach. An integrated thermophotovoltaic power module and residential scale furnace system (40,000 Btu/h) were modeled and studied in detail to assess the influence of different design configurations on primary energy efficiency. Operational characteristics such as total power generation, electrical efficiency, and heat recovery were examined in a self-powered system configuration. A sensitivity analysis was conducted to determine the influence of the electric grid’s carbon dioxide footprint (carbon intensity) and the cost of electricity on the environmental, as well as the economic, benefit associated with the self-powered configuration. Compared with a traditional furnace powered by an electric grid at a carbon intensity of 0.5 kg CO 2eq /kWh EL , the self-powered furnace was shown to decrease the annual carbon dioxide emissions by approximately 550 kg (~75% reduction), while also saving more than USD 200 in utility expenses, annually. Additionally, the carbon emission reduction potential of blending different concentrations of hydrogen in natural gas fuel was also studied.

14 SOLAR ENERGY↗

A Sustainable Wind–Biogas Hybrid System for Remote Areas in Jordan: A Case Study of Mobile Hospital for a Zaatari Syrian Refugee Camp

Access to reliable and sustainable energy in remote areas remains a pressing global challenge, significantly affecting economic development and the quality of life. This study focuses on the implementation of fully off-grid wind–biogas hybrid power systems to address this issue, with a focus on remote healthcare camp facilities. This paper investigates the performance of a hybrid renewable energy system within the context of one of Jordan’s northern remote areas, the Zaatari Syrian Refugee Camp, assessing its efficiency and environmental impact by taking the Zaatari hospital as the case study. Simulations were conducted to evaluate system components, including wind turbines, biogas generators, and diesel generators. A comprehensive evaluation was conducted, encompassing both the operational efficiency of the system and its impact on the environment. This study also considered various scenarios (SC#), including grid availability and autonomy levels, to optimize system configurations. The techno-economic assessment employed the levelized cost of energy (LCOE) as a key performance indicator, and sensitivity analyses explored the impact of diesel costs and wind power fluctuations on the system. Additionally, environmental assessment was conducted to evaluate the environmental effects of hybrid systems, with a specific focus on reducing greenhouse gas emissions. This investigation involved an examination of emissions in three different scenarios. The results indicate that the lowest LCOE that could be achieved was 0.0734 USD/kWh in SC#1 with 72.42% autonomy, whereas achieving 100% autonomy increased the LCOE to 0.1756 USD/kWh. Additionally, the results reveal that in scenarios SC#2 and SC#3, which have a higher proportion of diesel generator usage, there were elevated levels of NO x and CO 2 emissions. Conversely, in SC#1, which lacks diesel generators, emissions were notably lower. The proposed hybrid system demonstrates its potential to provide a reliable energy supply to healthcare facilities in remote regions, emphasizing both economic feasibility and environmental benefits. These findings contribute to informed decision making for sustainable energy solutions in similar contexts, promoting healthcare accessibility and environmental sustainability.

09 BIOMASS FUELS↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗