Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally graded materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

GaSb solar cells grown on GaAs via interfacial misfit arrays for use in the III-Sb multi-junction cell

We present that growth of GaSb with low threading dislocation density directly on GaAs may be possible with the strategic strain relaxation of interfacial misfit arrays. This creates an opportunity for a multijunction solar cell with access to a wide range of well-developed direct bandgap materials. Multijunction cells with a single layer of GaSb/GaAs interfacial misfit arrays could achieve higher efficiency than state-of-the-art inverted metamorphic multi-junction cells while forgoing the need for costly compositionally graded buffer layers. To develop this technology, GaSb single junction cells were grown via molecular beam epitaxy on both GaSb and GaAs substrates to compare homoepitaxial and heteroepitaxial GaSb device results. The GaSb-on-GaSb cell had an AM1.5g efficiency of 5.5% and a 44-sun AM1.5d efficiency of 8.9%. The GaSb-on-GaAs cell was 1.0% efficient under AM1.5g and 4.5% at 44 suns. The lower performance of the heteroepitaxial cell was due to low minority carrier Shockley-Read-Hall lifetimes and bulk shunting caused by defects related to the mismatched growth. A physics-based device simulator was used to create an inverted triple-junction GaInP/GaAs/GaSb model. Lastly, the model predicted that, with current GaSb-on-GaAs material quality, the not-current-matched, proof-of-concept cell would provide 0.5% absolute efficiency gain over a tandem GaInP/GaAs cell at 1 sun and 2.5% gain at 44 suns, indicating that the effectiveness of the GaSb junction was a function of concentration.

14 SOLAR ENERGY↗

Chemical Characterization and Removal of Carbon-14 from Irradiated Graphite II - 13023

Approximately 250,000 tonnes of irradiated graphite waste exists worldwide and that quantity is expected to increase with decommissioning of Generation II reactors and deployment of Generation IV gas-cooled, graphite moderated reactors. This situation indicates the need for a graphite waste management strategy. Of greatest concern for long-term disposal of irradiated graphite is carbon-14 (C-14), with a half-life of 5730 years. Study of irradiated graphite from some nuclear reactors indicates C-14 is concentrated on the outer 5 mm of the graphite structure. The aim of the research presented last year and updated here is to identify the chemical form of C-14 in irradiated graphite and develop a practical method by which C-14 can be removed. A nuclear-grade graphite, NBG-18, and a high-surface-area graphite foam, POCOFoam{sup R}, were exposed to liquid nitrogen (to increase the quantity of C-14 precursor) and neutron-irradiated (10{sup 13} neutrons/cm{sup 2}/s). Finer grained NBG-25 was not exposed to liquid nitrogen prior to irradiation at a neutron flux on the order of 10{sup 14} /cm{sup 2}/s. Characterization of pre- and post-irradiation graphite was conducted to determine the chemical environment and quantity of C-14 and its precursors via the use of surface sensitive characterization techniques. Scanning Electron Microscopy (SEM) was used to evaluate the morphological features of graphite samples. The concentration, chemical composition, and bonding characteristics of C-14 and its precursors were determined through X-ray Photoelectron Spectroscopy (XPS), Time-of-Flight Secondary Ion Mass Spectrometry (SIMS), and Energy Dispersive X-ray Analysis Spectroscopy (EDX). Results of post-irradiation characterization of these materials indicate a variety of surface functional groups containing carbon, oxygen, nitrogen and hydrogen. During thermal treatment, irradiated graphite samples are heated in the presence of an inert carrier gas (with or without oxidant gas), which carries off gaseous products released during treatment. Graphite gasification occurs via interaction with adsorbed oxygen complexes. Experiments in argon were performed at 900 deg. C and 1400 deg. C to evaluate the selective removal of C-14. Thermal treatment also was performed with the addition of 3 and 5 volume % oxygen at temperatures 700 deg. C and 1400 deg. C. Thermal treatment experiments were evaluated for the effective selective removal of C-14. Lower temperatures and oxygen levels correlated to more efficient C-14 removal. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additive Manufacturing, Design, Testing, and Fabrication: A Full Engineering Experience at JSC

I worked on several projects this term. While most projects involved additive manufacturing, I was also involved with two design projects, two testing projects, and a fabrication project. The primary mentor for these was Richard Hagen. Secondary mentors were Hai Nguyen, Khadijah Shariff, and fabrication training from James Brown. Overall, my experience at JSC has been successful and what I have learned will continue to help me in my engineering education and profession long after I leave. My 3D printing projects ranged from less than a 1 cubic centimeter to about 1 cubic foot and involved several printers using different printing technologies. It was exciting to become familiar with printing technologies such as industrial grade FDM (Fused Deposition Modeling), the relatively new SLA (Stereolithography), and PolyJet. My primary duty with the FDM printers was to model parts that came in from various sources to print effectively and efficiently. Using methods my mentor taught me and the Stratasys Insight software, I was able to minimize imperfections, hasten build time, improve strength for specific forces (tensile, shear, etc...), and reduce likelihood of a print-failure. Also using FDM, I learned how to repair a part after it was printed. This is done by using a special kind of glue that chemically melts the two faces of plastic parts together to form a fused interface. My first goal with SLA technology was to bring the printer back to operational readiness. In becoming familiar with the Pegasus SLA printer, I researched the leveling, laser settings, and different vats to hold liquid material. With this research, I was successfully able to bring the Pegasus back online and have successfully printed multiple sample parts as well as functional parts. My experience with PolyJet technology has been focused on an understanding of the abilities/limits, costs, and the maintenance for daily use. Still upcoming will be experience with using a composite printer that uses FDM technology to print plastic while laying an internal filament of Kevlar or carbon-fiber inside the printed material. It has been incredible being exposed to this range of technologies and I feel very fortunate to be ready for virtually any kind of printing technology I come across in the future. Design work played a part in my internship this term as well. Working with Hai Nguyen, I was able to design a set of testing tips and a test frame for use with an Arcjet. The testing tips will be made of several different materials that will possibly be used in the heat shield of the Orion space craft. These designs included technical drawings that were presented to the fabrication shop. The frame design was created from 80/20 (a popular brand of frame construction equipment) and included an order form with pricing for fabrication. An independent design was also done for the virtual reality lab. This design was to create a hand-controller based on a previous design. This final design was sent directly to a 3D printer without technical drawings. Overall, my design work has given me experience with using 80/20, helped improve my CAD (Computer Aided Design) proficiency, and increased my knowledge of how to set up technical drawings for fabrication. The final role I have played in this internship has been to assist with testing of the inflatable technology materials working Khadijah Shariff. I began the internship assisting with permeability testing with the initial plan to continue the testing independently after training. Unfortunately, the testing apparatus suffered a technical failure and had funding pulled which cancelled that portion of the project. Further testing with inflatable technology continued with tensile testing of various stitching methods. This testing took place over a two-days and concluded successfully. Final testing was to be more tensile testing but of straps used to connect various inflatable sections. Unfortunately, the needed grips for the tensile tests could not be located and put the testing on hold. It is possible this round of testing will still take place by the end of the internship if the grips can be found. Overall, this portion of the internship has helped me become familiar with one kind of permeability test as well as a popular tensile/compression testing machine. Finally, I also had the chance to be trained using a metal lathe for making very small tips for a soldering iron. These tips will be used to melt threaded brass inserts into 3D printed plastic. Working with James Brown, I was able to successfully machine a brass rod down to as little as 0.064 inches plus or minus 0.001 inches. It was very rewarding to learn how to best use the machine and become familiar with a skill that will undoubtedly be used again in the future. I have been told by several professional engineers that learning to use a lathe and mill will be invaluable skills in the field. This knocks 50 percent of that goal off and I look forward to learning the mill at some point in the future. As is apparent with this list of projects, my internship was not focused on a single over-arching goal. Instead, I was able to gain experience in a myriad of very different areas. I feel like my time here was spent bouncing from one project to the next. Though sometimes difficult to switch gears, it was very rewarding to be a part of so much in so little time. My career and education will be positively impacted by what I have learned at JSC. My experience with 3D printing has improved my ability to handle many issues that may come up in the future with multiple different technologies. The design work I took part in, especially creating technical drawings, will help me better present designs to any engineer or shop I will encounter. My testing experience has helped me become familiar with a popular kind of tensile test machine that will likely be similar to the kinds I will encounter in the future. Finally, my experience with fabrication has given me a rare opportunity, as an engineer, to take part in the fabrication of a part. This experience will help me better tailor my future designs for the manufacturing process and has given me an appreciation for detailed/delicate machining work. My experience at JSC has been successful and will continue to assist me for a long time within the engineering field.

Zusack, Steven↗

A Graded, Porous Composite of Natural Biopolymers and Octacalcium Phosphate Guides Osteochondral Differentiation of Stem Cells

Abstract Lesions involving the osteochondral unit are difficult to treat. Biomimetic scaffolds are previously shown as promising alternative. Such devices often lack multiple functional layers that mimic bone, cartilage, and the interface. In this study, multilayered scaffolds are developed based on the use of natural extracellular matrix (ECM)‐like biopolymers. Particular attention is paid to obtain a complex matrix that mimics the native osteochondral transition. Porous, sponge‐like chitosan‐collagen‐octacalcium phosphate (OCP) scaffolds are obtained. Collagen content increases while the amount of OCP particles decreases toward the cartilage layer. The scaffolds are bioactive as a mineral layer is deposited containing hydroxyapatite at the bony side. The scaffolds stimulate proliferation of human adipose‐derived mesenchymal stem cells, but the degree of proliferation depends on the cell seeding density. The scaffolds give rise to a zone‐specific gene expression. RUNX2, COL1A1, BGLAP, and SPP1 are upregulated in the bony layer of the scaffold. SOX9 is upregulated concomitant with COL2A1 expression in the cartilage zone. Mineralization in presence of the cells is prominent in the bone area with Ca and P steadily increasing over time. These results are encouraging for the fabrication of biomimetic scaffolds using ECM‐like materials and featuring gradients that mimic native tissues and their interface.

Amann, Elisabeth↗

Assessment and Response of Treated Cocos nucifera Reinforced Toughened Epoxy Composite Towards Fracture and Viscoelastic Properties

The current research work is dedicated to addressing the fibre orientation problem and environmental issues through the development of micron-sized coir particle reinforced epoxy composite with enhanced fracture toughness and viscoelastic properties. A ‘specific grade’ standard epoxy adhesive based polymer composite is produced with reinforcement of surface modified coir particle filler. The surface modification on raw coir filler is carried out by NaOH and confirmed by Fourier transform infrared spectroscopy (FTIR), X-ray diffractogram and thermogravimetric analysis (TGA). The reduced intensity of hydroxide functional group as well as the enhanced thermal stability of surface modified coir filler is observed by FTIR and TGA respectively. The properties of produced composite samples are investigated by tensile test with low to high strain rate, fracture toughness test and dynamic mechanical analysis. The investigation revealed an improvement in tensile strength, fracture toughness and storage modulus values of toughened coir–epoxy composite with filler loading. The maximum value of ultimate tensile strength, modulus of elasticity and fracture toughness were 27.58 MPa, 0.738 GPa and 1.792 MPa m{sup 1/2}. The constraints like strain rate and filler content demarcated some critical effects on tensile strength, Young’s modulus and modulus of rupture. The research work suggests the applicability of the developed material as household items, replacement of timber product for indoor and outdoor decorations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multiscale topology optimization using neural network surrogate models

In this study, we are concerned with optimization of macroscale elastic structures that are designed utilizing spatially varying microscale metamaterials. The macroscale optimization is accomplished using gradient-based nonlinear topological optimization. But instead of using density as the optimization decision variable, the decision variables are the multiple parameters that define the local microscale metamaterial. This is accomplished using single layer feedforward Gaussian basis function networks as a surrogate models of the elastic response of the microscale metamaterial. The surrogate models are trained using highly resolved continuum finite element simulations of the microscale metamaterials and hence are significantly more accurate than analytical models e.g. classical beam theory. Because the derivative of the surrogate model is important for sensitivity analysis of the macroscale topology optimization, a neural network training procedure based on the Sobolev norm is described. Since the SIMP method is not appropriate for spatially varying lattices, an alternative method is developed to enable creation of void regions. Lastly, the efficacy of this approach is demonstrated via several examples in which the optimal graded metamaterial outperforms a traditional solid structure.

42 ENGINEERING↗

A Risk-Informed Performance-Based Methodology to Manage Fire Protection Systems in Nuclear Facilities

Fire protection systems (FPSs) and features are installed in U.S. Department of Energy (DOE) Hazard Category 1, 2, or 3 nuclear facilities to protect property (maximum possible fire loss thresholds), life, and nuclear safety (i.e., structures, systems, and components). These FPSs and features are designed and maintained in accordance with the prescriptive guidance provided in applicable building codes and National Fire Protection Association codes and standards. Management, operations, and maintenance activities of FPSs involve significant effort. A DOE facility’s documented safety analysis or other safety basis document could also rely on FPSs to provide either a safety significant or safety class function to mitigate fire hazards and minimize radiological consequences. In some cases, the designation of safety significant or safety class may be determined to provide a layer of defense-in-depth to minimize nuclear safety risks independent of the fire risk. DOE standards allow the use of performance-based design alternatives developed by the fire industry but do not consider the defense-in-depth layers of protection provided in DOE facilities to prevent or mitigate the risks associated with unintended release of radioactive materials into the environment. Pacific Northwest National Laboratory developed a decision-making methodology tailored for DOE non-reactor nuclear facilities to manage FPSs and features by integrating nuclear safety risk insights into a performance-based analysis. This risk-informed, performance-based (RIPB) methodology can be used to provide the technical basis for classifying an FPS as safety class and safety significant, tailoring administrative controls (e.g., technical safety requirements), and ranking the importance of FPSs to prioritize maintenance, upgrades, and replacement activities. The RIPB methodology is a graded approach to inform DOE facility owners and Fire Protection Program managers of the most risk-significant FPSs and equipment, and those systems would be cost-beneficial to relax rigor if there is a need to re-design the FPS coverage or deviate from DOE and National Fire Protection Association standards for those systems that would be less significant. This paper describes the framework used to develop the RIPB methodology and the outcome of implementing this methodology in a use-case nuclear facility. This paper also discusses the impact to DOE policies and standards and the safety margins and defense-in-depth measures credited in nuclear safety assessments in a facility’s documented safety analysis and the benefits of implementing an RIPB methodology in lieu of a prescriptive method to comply with fire protection requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Combined Ventilation and Perfusion Imaging Correlates With the Dosimetric Parameters of Radiation Pneumonitis in Radiation Therapy Planning for Lung Cancer

Purpose: The purpose of this study was to prospectively investigate clinical correlations between dosimetric parameters associated with radiation pneumonitis (RP) and functional lung imaging. Methods and Materials: Functional lung imaging was performed using four-dimensional computed tomography (4D-CT) for ventilation imaging, single-photon emission computed tomography (SPECT) for perfusion imaging, or both (V/Q-matched region). Using 4D-CT, ventilation imaging was derived from a low attenuation area according to CT numbers below different thresholds (vent-860 and -910). Perfusion imaging at the 10th, 30th, 50th, and 70th percentile perfusion levels (F10-F70) were defined as the top 10%, 30%, 50%, and 70% hyperperfused normal lung, respectively. All imaging data were incorporated into a 3D planning system to evaluate correlations between RP dosimetric parameters (where fV20 is the percentage of functional lung volume irradiated with >20 Gy, or fMLD, the mean dose administered to functional lung) and the percentage of functional lung volume. Radiation pneumonitis was evaluated using Common Terminology Criteria for Adverse Events version 4.0. Statistical significance was defined as a P value of <.05. Results: Sixty patients who underwent curative radiation therapy were enrolled (48 patients for non-small cell lung cancer, and 12 patients for small cell lung cancer). Grades 1, 2, and ≥3 RP were observed in 16, 44, and 6 patients, respectively. Significant correlations were observed between the percentage of functional lung volume and fV20 (r=0.4475 in vent-860 and 0.3508 in F30) or fMLD (r=0.4701 in vent-860 and 0.3128 in F30) in patients with grade ≥2 RP. F30∩vent-860 results exhibited stronger correlations with fV20 and fMLD in patients with grade ≥2 (r=0.5509 in fV20 and 0.5320 in fMLD) and grade ≥3 RP (r=0.8770 in fV20 and 0.8518 in fMLD). Conclusions: RP dosimetric parameters correlated significantly with functional lung imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AGC-2 Irradiation Data Qualification (Final Report)

The Graphite Technology Development Program will run a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. The second Advanced Graphite Creep (AGC) experiment (AGC-2) began with Advanced Test Reactor (ATR) Cycle 149A on April 12, 2011, and ended with ATR Cycle 151B on May 5, 2012. The purpose of this report is to qualify AGC-2 irradiation monitoring data following INL Management and Control Procedure 2691, Data Qualification. Data that are Qualified meet the requirements for data collection and use as described in the experiment planning and quality assurance documents. Data that do not meet the requirements are Failed . Some data may not quite meet the requirements, but may still provide some useable information. These data are labeled as Trend . No Trend data were identified for the AGC-2 experiment. All thermocouples functioned throughout the AGC-2 experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Relevance of Biologically Equivalent Dose Values in Outcome Evaluation of Stereotactic Radiotherapy for Lung Nodules

Purpose: Different biologically equivalent dose (BED) values associated with stereotactic radiotherapy (SRT) of patients with primary and metastatic pulmonary nodules were studied. The BED values were calculated for tumoral tissue and low {alpha}/{beta} ratio, assuming that better local response could be obtained by using stereotactic high-BED treatment. Methods and Materials: Fifty-eight patients with T1-T3 N0 non-small-cell lung cancer and 46 patients with metastatic lung nodules were treated with SRT. The BED was calculated for {alpha}/{beta} ratios of 3 and 10. Overall survival (OS) was assessed according to Kaplan-Meier and appraised as a function of three BED levels: low (30-50 Gy), medium (50-70 Gy), and high (70-98 Gy; {alpha}/{beta} = 10). Results: The OS rates for all 104 patients at 12, 24, and 36 months were 73%, 48.3%, and 35.8%, respectively. Local response greater than 50% for low, medium, and high BED values was observed in 54%, 47%, and 73%, respectively. In the high-BED treated group, OS rates at 12, 24, and 36 months (80.9%, 70%, and 53.6%, respectively) were significantly improved compared with low- (69%, 46.1%, and 30.7%, respectively) and medium-BED (67%, 28%, and 21%, respectively) treated patients. Results are also discussed in terms of BED calculated on {alpha}/{beta} 3 Gy characteristic of the microcapillary bed. No acute toxicity higher than Grade 1 was observed. Conclusions: Radioablation of pulmonary neoplastic nodules may be achieved with SRT delivered by using a high-dose fraction with high BED value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bladder Function Preservation With Brachytherapy, External Beam Radiation Therapy, and Limited Surger in Bladder Cancer Patients: Long-Term Results

Purpose: To report long-term results of a bladder preservation strategy for muscle-invasive bladder cancer (MIBC) using external beam radiation therapy and brachytherapy/interstitial radiation therapy (IRT). Methods and Materials: Between May 1989 and October 2011, 192 selected patients with MIBC were treated with a combined regimen of preoperative external beam radiation therapy and subsequent surgical exploration with or without partial cystectomy and insertion of source carrier tubes for afterloading IRT using low dose rate and pulsed dose rate. Data for oncologic and functional outcomes were prospectively collected. The primary endpoints were local recurrence-free survival (LRFS), bladder function preservation survival, and salvage cystectomy-free survival. The endpoints were constructed according to the Kaplan-Meier method. Results: The mean follow-up period was 105.5 months. The LRFS rate was 80% and 73% at 5 and 10 years, respectively. Salvage cystectomy-free survival at 5 and 10 years was 93% and 85%. The 5- and 10-year overall survival rates were 65% and 46%, whereas cancer-specific survival at 5 and 10 years was 75% and 67%. The distant metastases-free survival rate was 76% and 69% at 5 and 10 years. Multivariate analysis revealed no independent predictors of LRFS. Radiation Therapy Oncology Group grade ≥3 late bladder and rectum toxicity were recorded in 11 patients (5.7%) and 2 patients (1%), respectively. Conclusions: A multimodality bladder-sparing regimen using IRT offers excellent long-term oncologic outcome in selected patients with MIBC. The late toxicity rate is low, and the majority of patients preserve their functional bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bifunctionally Graded Electrode Supported SOFC Modeling and Computational Thermal Fluid Analysis for Experimental Design

A comprehensive 3D computational fluid dynamics (CFD) model is developed for a bi-electrode supported cell (BSC) solid oxide fuel cell (SOFC). The model includes complicated transport phenomena of mass/heat transfer, charge (electron and ion) migration, and electrochemical reactions. The uniqueness of the modeling study is that functionally graded porous electrode property is taken into account, including not only linear but also nonlinear porosity distributions. The model is validated using experimental data from open literature. Numerical results indicate that BSC performance is strongly dependent on both operating conditions and porous microstructure distributions of electrodes. Using the proposed fuel/gas feeding design, the uniform hydrogen distribution within the porous anode is achieved; the oxygen distribution within the cathode is dependent on porous microstructure distributions as well as pressure loss conditions. Simulation results also show that fairly uniform temperature distribution can be obtained with the proposed fuel/gas feeding design. This modeling work can provide a pre-experimental analysis and guide experimental designs for BSC test.

carbon sequestration↗

Hypofractionated Intensity Modulated Radiation Therapy in Combined Modality Treatment for Bladder Preservation in Elderly Patients With Invasive Bladder Cancer

Purpose/Objective(s): To review our experience with bladder-preserving trimodality treatment (TMT) using hypofractionated intensity modulated radiation therapy (IMRT) for the treatment of elderly patients with muscle-invasive bladder cancer. Methods and Materials: Retrospective study of elderly patients treated with TMT using hypofractionated IMRT (50 Gy in 20 fractions) with concomitant weekly radiosensitizing chemotherapy. Eligibility criteria were as follows: age ≥70 years, a proven diagnosis of muscle-invasive transitional cell bladder carcinoma, stage T2-T3N0M0 disease, and receipt of TMT with curative intent. Response rate was assessed by cystoscopic evaluation and bladder biopsy. Results: 24 patients with a median age of 79 years were eligible. A complete response was confirmed in 83% of the patients. Of the remaining patients, 1 of them underwent salvage cystectomy, and no disease was found in the bladder on histopathologic assessment. After a median follow-up time of 28 months, of the patients with a complete response, 2 patients had muscle-invasive recurrence, 1 experienced locoregional failure, and 3 experienced distant metastasis. The overall and cancer-specific survival rates at 3 years were 61% and 71%, respectively. Of the surviving patients, 75% have a disease-free and functioning bladder. All patients completed hypofractionated IMRT, and 19 patients tolerated all 4 cycles of chemotherapy. Acute grade 3 gastrointestinal or genitourinary toxicities occurred in only 4% of the patients, and acute grade 3 or 4 hematologic toxicities, liver toxicities, or both were experienced by 17% of the cohort. No patient experienced grade 4 gastrointestinal or genitourinary toxicity. Conclusions: Hypofractionated IMRT with concurrent radiosensitizing chemotherapy appears to be an effective and well-tolerated curative treatment strategy in the elderly population and should be considered for patients who are not candidates for cystectomy or who wish to avoid cystectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study on the dynamic recrystallization model and mechanism of nuclear grade 316LN austenitic stainless steel

In this study, the dynamic recrystallization behaviors of a nuclear grade 316LN austenitic stainless steel were researched through hot compression experiment performed on a Gleeble-1500 simulator at temperatures of 900–1250 °C and strain rates of 0.01–1 s{sup −1}. By multiple linear regressions of the flow stress-strain data, the dynamic recrystallization mathematical models of this steel as functions of strain rate, strain and temperature were developed. Then these models were verified in a real experiment. Furthermore, the dynamic recrystallization mechanism of the steel was determined. The results indicated that the subgrains in this steel are formed through dislocations polygonization and then grow up through subgrain boundaries migration towards high density dislocation areas and subgrain coalescence mechanism. Dynamic recrystallization nucleation performs in grain boundary bulging mechanism and subgrain growth mechanism. The nuclei grow up through high angle grain boundaries migration. - Highlights: •Establish the DRX mathematical models of nuclear grade 316LN stainless steel •Determine the DRX mechanism of this steel •Subgrains are formed through dislocations polygonization. •Subgrains grow up through subgrain boundaries migration and coalescence mechanism. •DRX nucleation performs in grain boundary bulging mechanism and subgrain growth mechanism.

36 MATERIALS SCIENCE↗

Aichi Cancer Center Initial Experience of Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer Using Helical Tomotherapy

Purpose: To assess the feasibility of helical tomotherapy (HT) for patients with nasopharyngeal carcinoma. Methods and Materials: From June 2006 to June 2007, 20 patients with nasopharyngeal carcinoma were treated with HT with (n = 18) or without (n = 2) systemic chemotherapy. The primary tumor and involved lymph node (PTV1) were prescribed 70 Gy and the prophylactic region 54 Gy at D95, respectively. The majority of patients received 2 Gy per fraction for PTV1 in 35 fractions. Parotid function was evaluated using quantitative scintigraphy at pretreatment, and posttreatment at 3 months and 1 year later. Results: The median patient age was 53 years, ranging from 15 to 83. Our cohort included 5, 8, 4, 2, and 1 patients with disease Stages IIB, III, IVA, IVB, and IVC, respectively. Histopathological record revealed two for World Health Organization Type I and 18 for Type 2 or 3. The median duration time for treatment preparation was 9.5 days, and all plans were thought to be acceptable regarding dose constraints of both the planning target volume and organ at risk. All patients completed their treatment procedure of intensity-modulated radiation therapy (IMRT). All patients achieved clinical remission after IMRT. The majority of patients had Grade 3 or higher toxicity of skin, mucosa, and neutropenia. At the median follow-up of 10.9 months, two patients recurred, and one patient died from cardiac disease. Parotid gland function at 1 year after completion of IMRT was significantly improved compared with that at 3 months. Conclusion: HT was clinically effective in terms of IMRT planning and utility for patients with nasopharyngeal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vibration Analysis of a Unimorph Nanobeam with a Dielectric Layer of Both Flexoelectricity and Piezoelectricity

In this study, for the first time, free and forced vibrational responses of a unimorph nanobeam consisting of a functionally graded base, along with a dielectric layer of both piezoelectricity and flexoelectricity, is investigated based on paradox-free local/nonlocal elasticity. The formulation and boundary conditions are attained by utilizing the energy method Hamilton’s principle. In order to set a comparison, the formulation of a model in the framework of differential nonlocal is first presented. An effective implementation of the generalized differential quadrature method (GDQM) is then utilized to solve higher-order partial differential equations. This method can be utilized to solve the complex equations whose analytic results are quite difficult to obtain. Lastly, the impact of various parameters is studied to characterize the vibrational behavior of the system. Additionally, the major impact of flexoelectricity compared to piezoelectricity on a small scale is exhibited. The results show that small-scale flexoelectricity, rather than piezoelectricity, is dominant in electromechanical coupling. One of the results that can be mentioned is that the beams with higher nonlocality have the higher voltage and displacement under the same excitation amplitude. The findings can be helpful for further theoretical as well as experimental studies in which dielectric material is used in smart structures.

36 MATERIALS SCIENCE↗

Surface roughness of anodized titanium coatings.

Samples of grade five 6Al4V titanium alloy were coated with two commercial fluoropolymer anodizations (Tiodize and Canadize) and compared. Neither coating demonstrates significant outgassing. The coatings show very similar elemental analysis, except for the presence of lead in the Canadize coating, which may account for its lower surface friction in humid environments. Surface roughness has been compared by SEM, contact profilometry, optical profilometry, power spectral density and bidirectional scattering distribution function (BSDF). The Tiodize film is slightly smoother by all measurement methods, but the Canadize film shows slightly less scatter at all angles of incidence. Both films exhibited initial friction coefficients of 0.2 to 0.4, increasing to 0.4 to 0.8 after 1000 cycles of sliding due to wear of the coating and ball. The coatings are very similar and should behave identically in most applications.

36 MATERIALS SCIENCE↗

Effect of Air Oxidation on Pore Structure Development and Mechanical Properties of Nuclear Graphite

This document reports on continuation of R&D activities at ORNL directed at investigating the effect of air oxidation of nuclear graphite on development and structure of porosity in the oxidized layer, and on the effect on mechanical properties of oxidized graphite. The material investigated was nuclear-grade graphite (purified PCEA graphite, from GrafTech International). Based on conclusions of previous work (ORNL/TM-2009/192), the method of analysis of the porosity in the oxidized layer based on optical microscopy coupled with automated image analysis was further improved and standardized. In addition, characterization of oxidized specimens by optical microscopy was complemented with measurements of mechanical properties (compressive strength) on a statistically significant number of specimens. A series of cylindrical shape specimens were machined and oxidized in air at two temperatures (600 and 700 o C) and at three levels of burn-off at each temperature (5-6 %; 10-12 % and 15-17%). The procedure used for specimen preparation and oxidation, and the oxidation equipment, were those recommended in ASTM D-7542-09. However, in order to comply with the aspect ratio requirements for specimens employed in compressive strength measurements (ASTM C-695-91) all specimens were machined with a length to diameter ratio of 2 (i.e. 25.4 mm height vs. 12.7 mm diameter) instead of 25.4 mm length and 25.4 mm diameter recommended by ASTM D-7542-09. After oxidation, mechanical properties (compressive strength) were measured on at least three samples obtained at equal oxidation conditions, while another specimen from the same lot was sectioned, mounted in resin and surface polished for optical microscopy analysis. In the latter procedure, mosaic pictures were collected of a rectangular stripe across the diameter of each specimen. These images were analyzed in order to derive the penetration depth and the pore structure in the oxidized layer as a function of oxidation temperature and weight loss level. Automated image analysis was performed using the commercial software Image Pro Plus. The results led to the conclusion that the depth of the oxidation layer is more dependent on the oxidation temperature than on the level of weight-loss. The penetration depth of the oxidized layer is about 6 mm at 600 o C and about 1.5 mm at 700 o C. Consequently, the 12.5 mm diameter specimens oxidized at 600 o C were completely penetrated by oxidation, while those oxidized at 700 o C had the oxidation layer restricted in a narrower band near the exposed surface. This difference was reflected by mechanical properties. A closer analysis of high magnification images in the oxidized layer revealed that oxidation attacks preferentially the binder phase in graphite, where development of fine new pores was observed. The density of new pores was higher near large pores pre-existing in graphite structure. Acute oxidation at low temperatures (e.g. 600 o C) causes more damage on mechanical strength than high temperature oxidation (700 o C). Although the latter is much faster, the oxidized layer is limited to a narrow zone next to the external surface, so that the core is not visibly affected. In contrast, oxidation at lower temperature, although slower, is more damaging because it penetrates deeply beyond the exposed surface.

36 MATERIALS SCIENCE↗