Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Hydrogen enhanced crack growth in 18 Ni maraging steels

The kinetics of sustained-load subcritical crack growth for 18 Ni maraging steels in high-purity hydrogen are examined using the crack-tip stress intensity factor K as a measure of crack driving force. Crack growth rate as a function of stress intensity exhibited a clearly defined K-independent stage (Stage II). Crack growth rates in an 18 Ni (grade 250) maraging steel are examined for temperatures from -6 to +100 C. A critical temperature was observed above which crack growth rates became diminishingly small. At lower temperatures the activation energy for Stage II crack growth was found to be 16.7 plus or minus 3.3 kJ/mole. Temperature and hydrogen partial pressure are shown to interact in a complex manner to determine the apparent Kth (stress intensity level below which no observable crack growth occurs) and the crack growth behavior. Comparison of results on '250' and '300' grades of 18 Ni maraging steel indicate a significant influence of alloy composition and/or strength level on the crack growth behavior.

Hudak, S. J., Jr.↗

High velocity continuous-flow reactor for the production of solar grade silicon

The feasibility of a high volume, high velocity continuous reduction reactor as an economical means of producing solar grade silicon was tested. Bromosilanes and hydrogen were used as the feedstocks for the reactor along with preheated silicon particles which function both as nucleation and deposition sites. A complete reactor system was designed and fabricated. Initial preheating studies have shown the stability of tetrabromosilane to being heated as well as the ability to preheat hydrogen to the desired temperature range. Several test runs were made and some silicon was obtained from runs carried out at temperatures in excess of 1180 K.

Woerner, L.↗

Beyond the classical kinetic model for chronic graphite oxidation by moisture in high temperature gas-cooled reactors

Four grades of nuclear graphite with various microstructures were subjected to accelerated oxidation tests in helium with traces of moisture and hydrogen in order to evaluate the effects of chronic oxidation on graphite components in high temperature gas cooled reactors. Kinetic analysis showed that the Langmuir-Hinshelwood (LH) model cannot consistently reproduce all results. In particular, at high temperatures and water partial pressures oxidation was always faster than the LH model predicts, with stronger deviations for superfine grain graphite than for medium grain grades. It was also found empirically that the apparent reaction order for water has a sigmoid-type variation with temperature which follows the integral Boltzmann distribution function. This suggests that the apparent activation with temperature of graphite reactive sites that causes deviations from the LH model is rooted in specific structural and electronic properties of surface sites on graphite. A semi-global kinetic model was proposed, whereby the classical LH model was modified with a temperature-dependent reaction order for water. The new Boltzmann-enhanced model (BLH) was shown to consistently predict experimental oxidation rates over large ranges of temperature (800-1100 oC) and partial pressures of water (3-1200 Pa) and hydrogen (0-300 Pa), not only for the four grades of graphite but also for the historic grade H-451. The BLH model offers as more reliable input for modeling the chemical environment effects during the life-time operation of new grades of graphite in advanced nuclear reactors operating at high and very high temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ASCENDE-RT: An Analysis of Treatment-Related Morbidity for a Randomized Trial Comparing a Low-Dose-Rate Brachytherapy Boost with a Dose-Escalated External Beam Boost for High- and Intermediate-Risk Prostate Cancer

Purpose: To report the genitourinary (GU) and gastrointestinal (GI) morbidity and erectile dysfunction in a randomized trial comparing 2 methods of dose escalation for high- and intermediate-risk prostate cancer. Methods and Materials: ASCENDE-RT (Androgen Suppression Combined with Elective Nodal and Dose Escalated Radiation Therapy) enrolled 398 men, median age 68 years, who were then randomized to either a standard arm that included 12 months of androgen deprivation therapy and pelvic irradiation to 46 Gy followed by a dose-escalated external beam radiation therapy (DE-EBRT) boost to 78 Gy, or an experimental arm that substituted a low-dose-rate prostate brachytherapy (LDR-PB) boost. At clinic visits, investigators recorded GU and GI morbidity and information on urinary continence, catheter use, and erectile function. Exclusion of 15 who received nonprotocol treatment and correction of 14 crossover events left 195 men who actually received a DE-EBRT boost and 188, an LDR-PB boost. Median follow-up was 6.5 years. Results: The LDR-PB boost increased the risk of needing temporary catheterization and/or requiring incontinence pads. At 5 years the cumulative incidence of grade 3 GU events was 18.4% for LDR-PB, versus 5.2% for DE-EBRT (P<.001). Compared with the cumulative incidence, the 5-year prevalence of grade 3 GU morbidity was substantially lower for both arms (8.6% vs 2.2%, P=.058). The 5-year cumulative incidence of grade 3 GI events was 8.1% for LDR-PB, versus 3.2% for DE-EBRT (P=.124). The 5-year prevalence of grade 3 GI toxicity was lower than the cumulative incidence for both arms (1.0% vs 2.2%, respectively). Among men reporting adequate baseline erections, 45% of LDR-PB patients reported similar erectile function at 5 years, versus 37% after DE-EBRT (P=.30). Conclusions: The incidence of acute and late GU morbidity was higher after LDR-PB boost, and there was a nonsignificant trend for worse GI morbidity. No differences in the frequency of erectile dysfunction were observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Evaluation of Acute Toxicity and Quality of Life After IMRT and Concurrent Chemotherapy for Anal Canal and Perianal Cancer

Purpose: A prospective cohort study was conducted to evaluate toxicity, quality of life (QOL), and clinical outcomes in patients treated with intensity modulated radiation therapy (IMRT) and concurrent chemotherapy for anal and perianal cancer. Methods and Materials: From June 2008 to November 2010, patients with anal or perianal cancer treated with IMRT were eligible. Radiation dose was 27 Gy in 15 fractions to 36 Gy in 20 fractions for elective targets and 45 Gy in 25 fractions to 63 Gy in 35 fractions for gross targets using standardized, institutional guidelines, with no planned treatment breaks. The chemotherapy regimen was 5-fluorouracil and mitomycin C. Toxicity was graded with the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. QOL was assessed with the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 and CR29 questionnaires. Correlations between dosimetric parameters and both physician-graded toxicities and patient-reported outcomes were evaluated by polyserial correlation. Results: Fifty-eight patients were enrolled. The median follow-up time was 34 months; the median age was 56 years; 52% of patients were female; and 19% were human immunodeficiency virus—positive. Stage I, II, III, and IV disease was found in 9%, 57%, 26%, and 9% of patients, respectively. Twenty-six patients (45%) required a treatment break because of acute toxicity, mainly dermatitis (23/26). Acute grade 3 + toxicities included skin 46%, hematologic 38%, gastrointestinal 9%, and genitourinary 0. The 2-year overall survival (OS), disease-free survival (DFS), colostomy-free survival (CFS), and cumulative locoregional failure (LRF) rates were 90%, 77%, 84%, and 16%, respectively. The global QOL/health status, skin, defecation, and pain scores were significantly worse at the end of treatment than at baseline, but they returned to baseline 3 months after treatment. Social functioning and appetite scores were significantly better at 12 months than at baseline. Multiple dose-volume parameters correlated moderately with diarrhea, skin, and hematologic toxicity scores. Conclusion: IMRT reduces acute grade 3 + hematologic and gastrointestinal toxicities compared with reports from non-IMRT series, without compromising locoregional control. The reported QOL scores most relevant to acute toxicities returned to baseline by 3 months after treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The 2001 Mars In-Situ-Propellant-Production Precursor (MIP) Flight Demonstration

The successful performance of the five individual demonstrations of MARS IN-SITU-PROPELLANT-PRODUCTION PRECURSOR (MIP) will provide both knowledge of and confidence in the reliability of this technology. At the completion of this flight demonstration, the MIP Team will be able to: a) recommend preferred hardware configurations for the intake and adsorption of carbon dioxide from the Martian atmosphere; b) understand the performance characteristics of zirconia cells to generate propellant-grade oxygen; c) understand long-term performance characteristics of advanced solar cells/arrays operated in the actual Mars environment; d) evaluate the functionality of methods to mitigate the deposition of airborne dust onto solar arrays; and e) recommend preferred hardware designs for innovative thermal management including the radiation of heat to the outside environment.

Kaplan, David I.↗

Assessing alcohol intake & its dose-dependent effects on liver enzymes by 24-h recall and questionnaire using NHANES 2001-2010 data

Alcohol is a significant component of the diet with dose-dependent risks and benefits. High doses of alcohol damage the liver and early symptoms of liver disease include changes in routinely assessed liver enzymes. Less is known regarding the mechanisms responsible for the benefits of moderate alcohol consumption, including their effects on the liver. The objectives of this study were to examine alcohol’s dose-dependent effects on markers of liver function (alkaline phosphatase (ALP), alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma glutamyl transferase (GGT), and bilirubin), as well as to compare the different methods of assessing alcohol intake using NHANES 2001–2010 adult data (N =24,807). Three methods were used to estimate alcohol intake from all volunteers: 24-h recall; the National Cancer Institute (NCI) method of usual intake; and a specific alcohol intake questionnaire. Mean alcohol intake by 24-h recall, NCI method and questionnaire was 41.0 ± 0.8 g/d, 10.9 ± 0.2 g/d and 11.0 ± 0.2 g/d, respectively. Alcohol consumers had significantly lower levels of ALP and higher levels of AST, GGT and bilirubin compared to non-consumers (P < 0.01) and activities of ALT, AST, and GGT increased and of ALP decreased as alcohol intake increased, regardless of intake assessment method used. The most sensitive measure of alcohol consumption was GGT. Since alcohol had a graded linear effect on several liver enzymes, including at low and moderate doses, benefits as well as risks of alcohol intake may be related to liver function. In conclusion, since the NCI method and alcohol questionnaire yielded very similar alcohol intake estimates, this study cross-validated these methods and demonstrated the robustness of the NCI method for estimating intake of irregularly consumed foods.

60 APPLIED LIFE SCIENCES↗

Three filters for visualization of phase objects with large variations of phase gradients

We propose three amplitude filters for visualization of phase objects. They interact with the spectra of pure-phase objects in the frequency plane and are based on tangent and error functions as well as antisymmetric combination of square roots. The error function is a normalized form of the Gaussian function. The antisymmetric square-root filter is composed of two square-root filters to widen its spatial frequency spectral range. Their advantage over other known amplitude frequency-domain filters, such as linear or square-root graded ones, is that they allow high-contrast visualization of objects with large variations of phase gradients.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

Non-NASA Center↗

A neutron tomography study to visualize fluoride salt (FLiNaK) intrusion in nuclear-grade graphite

Manufactured graphite is a preferred material for in-core components of molten salt reactors and fluoride salt-cooled high-temperature reactors, which are in permanent contact with liquid salts. However, owing to the porous nature of nuclear graphite, under certain conditions, molten salts may intrude graphite's pores and affect graphite's properties and functionality. Therefore, a better understanding of molten salt intrusion (distribution across sample cross section and penetration depth) is needed to assess its effects. Here, in this work, we have demonstrated the use of neutron imaging (computed tomography) in the evaluation of salt penetration and distribution of a wide range of graphite grades with diverse microstructures that have been subjected to FLiNaK (LiF–NaF–KF) intrusion at 750 °C and 5 bar pressure for 12 h. Because of the great neutron attenuation contrast from scattering and adsorption between Li (from FLiNaK) and the graphite matrix, we have obtained direct visualization of FLiNaK salt distribution in the salt-impregnated graphites for the first time. Three-dimensional reconstructed images and cross-sectional concentration profiles demonstrate that salt penetration and density distribution are greatly dependent on the microstructural properties of the graphite grade.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An experimental study of convective heat transfer with microencapsulated phase change material suspension: Laminar flow in a circular tube under constant heat flux

By contrast with the conventional heat transfer fluid (water), the microencapsulated phase change material (MPCM) suspension, with a small temperature difference between storing and releasing heat, is of much larger apparent specific heat and much higher thermal energy storage capacity. It has been suggested to serve as a dual-functional medium for thermal energy transport and/or storage. The heat transfer characteristics of a kind of MPCM suspension, formed by microencapsulating industrial-grade 1-bromohexadecane (C{sub 16}H{sub 33}Br) as phase change material, were experimentally studied for laminar flow in a circular tube under constant heat flux. A new expression of Ste is put forward in the paper, according to the physical definition of Stefan number. The results in the experiments show: (a) the dimensionless internal wall temperature of the MPCM suspension is lower than pure water, and the decrease can be up to 30% of that of water; (b) the heat transfer enhancement ratio can be 1.42 times of that of water at x{sup +} = 4.2 x 10{sup -2} for 15.8 wt% MPCM suspension, which is not as much as in some references; and (c) the pump consumption of the MPCM suspension system decrease greatly for the larger heat transfer rate compared with water, due to phase change, the decrease can be up to 67.5% of that of water at q = 750 W (15.8 wt%). The kind of MPCM suspension has good application feasibility in practice. (author)

14 SOLAR ENERGY↗

Laparoscopic Cytoreductive Surgery with Hyperthermic Intraperitoneal Chemotherapy (L-CRS/HIPEC) for Perforated Low-Grade Appendiceal Mucinous Neoplasm (LAMN II)

Introduction: Cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (CRS/HIPEC) is an established treatment for pseudomyxoma peritonei resulting from a perforated low-grade appendiceal mucinous neoplasm (LAMN II). In patients with localized disease, a laparoscopic procedure (L-CRS/HIPEC) can be undertaken. Methods: This video demonstrates L-CRS/HIPEC in a 66-year-old male who had previously undergone an appendicectomy for an LAMN II lesion. The preoperative computed tomography (CT) scan suggested disease localized to the right iliac fossa. However, laparoscopic assessment unexpectedly revealed disease in the pelvis and on the right hemidiaphragm and liver surface. Results: A technique for treating the thin film of mucin in the pelvis and on the right hemidiaphragm is demonstrated. The liver is mobilized to facilitate ablation of mucin on the serosal surface of the right lobe. Tips and tricks for starting the omentectomy, dealing with the vascular pedicle, and completing the dissection in the left upper quadrant are shown. The Peritoneal Cancer Index (PCI) score was 5 (3 for the right upper quadrant, 1 for the pelvis, 1 for the small bowel), and the cytoreduction score was CC-1. The operative duration was 8.5 h, and length of hospital stay was 5 days. The patient returned to work after 6 weeks. Discussion: L-CRS/HIPEC can be performed when patients are unexpectedly found to have disease, provided the appendiceal pathology is low grade and the PCI score is low. There are potential benefits to this approach, with a shorter length of hospital stay and faster functional recovery when compared with traditional open surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advances in Detector-Integrated Filter Coatings for the Far Ultraviolet

We report on the continued development of multilayer optical coatings on back-illuminated silicon imaging sensors in order to enhance the functionality of such systems at ultraviolet wavelengths. This includes the development metal-dielectric filter structures to enable solar-blind operation, and graded thickness coatings to tune the spatial response of a detector system to the dispersion of a spectrometer. Such systems can maintain the high internal quantum efficiency afforded by the delta-doping process utilized at NASA JPL, while also providing long-wavelength rejection or a spatially optimized efficiency (or both). We present the characterization of CCD and CMOS image sensors incorporating these processes, and describe the atomic layer deposition coating processes. Such detectors are currently being developed for ground-based high energy physics applications as well as NASA orbital astrophysics instruments operating at wavelengths shorter than 200 nm.

Nikzad, Shouleh↗

SAS4A/SASSYS-1 VERIFICATION AND VALIDATION TEST SUITE

SAS4A/SASSYS-1 is a safety analysis software package already under copyright by Argonne National Laboratory. There is interest from third-party users of the software to gain access to our internal verification and validation test suite. Therefore we are seeking to establish copyright over the test suite, which includes input files and reference results for hundreds of test cases that demonstrate functionality of the software. Making the test suite available to licensed users allows them to utilize the broad range of tests for commercial grade dedication activities needed to qualify the SAS4A/SASSYS-1 software under their own Software Quality Assurance program for use in a regulatory environment (e.g. with the Nuclear Regulatory Commission).

FANNING, THOMAS↗

Low-temperature carbonization of polyacrylonitrile/graphene carbon fibers: A combined ReaxFF molecular dynamics and experimental study

Graphene inclusion in a polymer matrix is a promising route to significantly enhance the mechanical properties of low-grade carbon fibers (CFs). Using ReaxFF molecular dynamics simulation, the atomistic mechanism leading to this enhancement is investigated. We demonstrate that the graphene edges along with the nitrogen and oxygen functional groups play a catalytic role and act as seeds to expedite alignment of the all-carbon rings, which are starting sites for the growth of graphitic structures. To examine the role of this proposed mechanism that enhances the graphitic structure of PAN/graphene CFs, we discuss the experimental results wherein the PAN/graphene CFs carbonized at 1250 C demonstrate 91% (from 632 to 1207 MPa) increase in strength and 101% (from 88 to 177 GPa) enhancement in Young’s modulus compared to PAN-based CFs carbonized at 1500 C. In conclusion, these enhanced mechanical properties of low-grade carbon fibers achieved via graphene inclusion at decreased carbonization temperature provide a means to realize both energy savings and cost reduction.

42 ENGINEERING↗

Monolithic graded-refractive-index glass-based antireflective coatings. Broadband/omnidirectional light harvesting and self-cleaning characteristics

The design of multifunctional coatings impact impact the performance of many optical systems and components. Such coatings should be mechanically robust, and combine user-defined optical and wetting functions with scalable fabrication formulations. By taking cues from the properties of some natural biological structures, we report here the formation of low-refractive index antireflective glass films that embody omni-directional optical properties over a wide range of wavelengths, while also possessing specific wetting capabilities. The coatings comprise an interconnected network of nanoscale pores surrounded by a nanostructured silica framework. These structures result from a novel fabrication method that utilizes metastable spinodal phase separation in glass-based materials. The approach not only enables design of surface microstructures with graded-index antireflection characteristics, where the surface reflection is suppressed through optical impedance matching between interfaces, but also facilitates self-cleaning ability through modification of the surface chemistry. Based on near complete elimination of Fresnel reflections (yielding >95% transmission through a single-side coated glass) and corresponding increase in broadband transmission, the fabricated nanostructured surfaces are found to promote a general and an invaluable ~3–7% relative increase in current output of multiple direct/indirect bandgap photovoltaic cells. Moreover, these antireflective surfaces also demonstrate superior resistance against mechanical wear and abrasion. Unlike conventional counterparts, the present antireflective coatings are essentially monolithic, enabling simultaneous realization of graded index anti-reflectivity, self-cleaning capability, and mechanical stability within the same surface. Moreover, the concept represents a fundamental basis for development of advanced coated optical quality products, especially where environmental exposure is required.

36 MATERIALS SCIENCE↗

BCL-2 family protein, BAD is down-regulated in breast cancer and inhibits cell invasion

We have previously demonstrated that the anti-apoptotic protein BAD is expressed in normal human breast tissue and shown that BAD inhibits expression of cyclin D1 to delay cell-cycle progression in breast cancer cells. Herein, expression of proteins in breast tissues was studied by immunohistochemistry and results were analyzed statistically to obtain semi-quantitative data. Biochemical and functional changes in BAD-overexpressing MCF7 breast cancer cells were evaluated using PCR, reporter assays, western blotting, ELISA and extracellular matrix invasion assays. Compared to normal tissues, Grade II breast cancers expressed low total/phosphorylated forms of BAD in both cytoplasmic and nuclear compartments. BAD overexpression decreased the expression of β-catenin, Sp1, and phosphorylation of STATs. BAD inhibited Ras/MEK/ERK and JNK signaling pathways, without affecting the p38 signaling pathway. Expression of the metastasis-related proteins, MMP10, VEGF, SNAIL, CXCR4, E-cadherin and TlMP2 was regulated by BAD with concomitant inhibition of extracellular matrix invasion. Inhibition of BAD by siRNA increased invasion and Akt/p-Akt levels. Clinical data and the results herein suggest that in addition to the effect on apoptosis, BAD conveys anti-metastatic effects and is a valuable prognostic marker in breast cancer. - Highlights: • BAD and p-BAD expressions are decreased in breast cancer compared with normal breast tissue. • BAD impedes breast cancer invasion and migration. • BAD inhibits the EMT and transcription factors that promote cancer cell migration. • Invasion and migration functions of BAD are distinct from the BAD's role in apoptosis.

60 APPLIED LIFE SCIENCES↗

FINITE ELEMENT MODEL MESH REFINEMENT EFFECTS ON QUALIFICATION OF NUCLEAR GRADE GRAPHITE COMPONENTS

The American Society of Mechanical Engineers (ASME) provides the full and simplified design-by-analysis probabilistic assessments for determining acceptance of nuclear grade graphite core components. The assessments can be characterized by three parts: (1) a component stress distribution, often determined by a finite element (FE) model; (2) a Weibull probability density function (pdf) that characterizes the experimental tensile strength distribution; and (3) the post-processor, which combines the FE model and the Weibull strength distribution in accordance with the full and simplified assessments to determine component acceptance. It is known that the level of mesh refinement in FE models can affect the modeled component’s calculated stress distribution. Depending on the component geometry, the stress distribution may converge with sufficient refinement. It was previously unknown whether the acceptance decision resulting from the full and simplified assessments might change even with sufficient mesh refinement. This study explores that question using experimental strength results for a dog-bone geometry for two graphite grades, IG-110 and PCEA. The simplified assessment has two criteria that must be met, the first limits the combined membrane stress by the allowable stress and the second limits the peak equivalent stress by the allowable stress scaled by the ratio of flexural to tensile strength. In the application of the simplified assessment, convergence of the peak equivalent stress required extreme mesh refinement, however, the acceptance decision was not affected. It is hypothesized that more complex geometries with stress concentrations may present mesh refinement effects on the simplified assessment acceptance decision. Mesh refinement did affect the acceptance decision in the full assessment for the applied pressure loadings in this study. This work suggests component stress distribution convergence is not a sufficient criteria for POF convergence in the full assessment and that mesh refinement should continue until the POF has converged, especially where the resulting POF is bordering the SRC acceptable POF limit.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗