Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focuses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Evaluation of Turner relaxed state as a model of long-lived ion-trapping structures in plasma focus and Z-pinches

Relatively long-lived spheroidal structures coincident with the neutron emission phase have been observed in frozen deuterium fiber Z-pinch and some plasma focus devices. Existence of energetic ion-trapping mechanism in plasma focus has also been inferred from experimental data. It has been conjectured that these are related phenomena. This paper applies Turner's theory [L. Turner, IEEE Trans. Plasma Sci. 14, 849 (1986)] of relaxation of a Hall magnetofluid to construct a model of these structures and ion-trapping mechanism. Turner's solution modified for a finite-length plasma is used to obtain expressions for the magnetic field, velocity, and equilibrium pressure fields and is shown to represent an entity which is simultaneously a fluid vortex, a force-free magnetic field, a confined finite-pressure plasma, a charged object, and a trapped energetic ion beam. Characteristic features expected from diagnostic experiments are evaluated and shown to resemble experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusion neutron detector for time-of-flight measurements in z-pinch and plasma focus experiments

We have developed and tested sensitive neutron detectors for neutron time-of-flight measurements in z-pinch and plasma focus experiments with neutron emission times in tens of nanoseconds and with neutron yields between 10{sup 6} and 10{sup 12} per one shot. The neutron detectors are composed of a BC-408 fast plastic scintillator and Hamamatsu H1949-51 photomultiplier tube (PMT). During the calibration procedure, a PMT delay was determined for various operating voltages. The temporal resolution of the neutron detector was measured for the most commonly used PMT voltage of 1.4 kV. At the PF-1000 plasma focus, a novel method of the acquisition of a pulse height distribution has been used. This pulse height analysis enabled to determine the single neutron sensitivity for various neutron energies and to calibrate the neutron detector for absolute neutron yields at about 2.45 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-focusing of cosh-Gaussian laser beam in a plasma with weakly relativistic and ponderomotive regime

This paper presents an investigation of the self-focusing of cosh-Gaussian laser beam in a plasma with linear absorption taking into account the combined effects of relativistic and ponderomotive type nonlinearities. Nonlinear parabolic partial differential equation governing the evolution of complex envelope in slowly varying envelope approximation is solved using variational approach. Self-focusing and self-phase modulation as well as self-trapping of cosh-Gaussian beam are studied at various values of decentered parameter b, with different absorption levels k{sub i}{sup '}. Numerical analysis shows that these parameters play vital role on propagation characteristics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Hamiltonian method for collective dynamics analysis of an intense charged particle beam propagating through a periodic focusing quadrupole lattice

Identifying regimes for quiescent propagation of intense beams over long distances has been a major challenge in accelerator research. In particular, the development of systematic theoretical approaches that are able to treat self-consistently the applied oscillating force and the nonlinear self-field force of the beam particles simultaneously has been a major challenge of modern beam physics. In this paper, the recently developed Hamiltonian averaging technique [E. A. Startsev, R. C. Davidson, and M. Dorf, Phys. Rev. ST Accel. Beams 13, 064402 (2010)] which incorporates both the applied periodic focusing force and the self-field force of the beam particles, is generalized to the case of time-dependent beam distributions. The new formulation allows not only a determination of quasi-equilibrium solutions of the non-linear Vlasov-Poison system of equations but also a detailed study of their stability properties. The corrections to the well-known ''smooth-focusing'' approximation are derived, and the results are applied to a matched beam with thermal equilibrium distribution function. It is shown that the corrections remain small even for moderate values of the vacuum phase advance {sigma}{sub {upsilon}}. Nonetheless, because the corrections to the average self-field potential are non-axisymmetric, the stability properties of the different beam quasi-equilibria can change significantly.

43 PARTICLE ACCELERATORS↗

Development of an Adaptive Optical System for Sub-10-nm Focusing of Synchrotron Radiation Hard X-rays

In the hard x-ray region, to obtain the theoretical resolution or diffraction-limited focusing size in an imaging optical system, both ultraprecise optics and highly accurate alignment are necessary. An adaptive optical system is used for the compensation of aberrations in various optical systems, such as optical microscopes and space telescopes. In situ wavefront control of hard x-rays is also effective for realizing ideal performance. The aim of this paper is to develop an adaptive optical system for sub-10-nm hard x-ray focusing. The adaptive optical system performs the wavefront measurement using a phase retrieval algorithm and wavefront control using grazing-incidence deformable mirrors. Several results of experiments using the developed system are reported.

43 PARTICLE ACCELERATORS↗

Extraction of a strongly focusing He{sup +} beam from three-stage concave electrodes for alpha particle measurement system in ITER

A strongly focusing He{sup +} ion beam source equipped with concave multi-aperture electrodes was developed for production of He{sup -} through a charge exchange cell. The beam was extracted at a voltage less than 20 kV from 301 apertures distributed in an area of 100 mm {phi}, and focused at 750 mm distance. The beam current and the beam size of 2 A and 20 mm in diameter, respectively, were achieved with an arc power less than 10 kW. The optimum perveance was obtained at 0.02 A/kV{sup 1.5} at the beam energy less than 20 keV which is suitable for the conversion to He{sup -} in an alkali vapor cell.

43 PARTICLE ACCELERATORS↗

Electrostatic plasma lens for focusing negatively charged particle beams

We describe the current status of ongoing research and development of the electrostatic plasma lens for focusing and manipulating intense negatively charged particle beams, electrons, and negative ions. The physical principle of this kind of plasma lens is based on magnetic isolation electrons providing creation of a dynamical positive space charge cloud in shortly restricted volume propagating beam. Here, the new results of experimental investigations and computer simulations of wide-aperture, intense electron beam focusing by plasma lens with positive space charge cloud produced due to the cylindrical anode layer accelerator creating a positive ion stream towards an axis system is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-field focused photoemission from polystyrene microspheres studied with photoemission electron microscopy

We use photoemission electron microscopy(PEEM) to image 3 μm diameter polystyrene spheres supported on a metalthin film illuminated by 400 nm (~3.1 eV) and 800 nm (~1.5 eV) femtosecond (fs) laser pulses. Intense photoemission is generated by microspheres even though polystyrene is an insulator and its ionization threshold is well above the photon energies employed. We observe intense photoemission from the far side (the side opposite the incident light) of the illuminated microsphere that is attributed to light focusing within the microsphere. For the case of p-polarized, 800 nm fs laser pulses, we observe photoemission exclusively from the far side of the microsphere and additionally resolve sub-50 nm hot spots in the supporting Pt/Pd thin film that are located only within the focal region of the microsphere. We compare the PEEM images with finite difference time domain(FDTD) electrodynamic simulations to model our experimental results. Finally, the FDTD simulations predict light focusing in the microsphere and subsequent interaction with the supporting metal surface that is consistent with the experimental observations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical characterization of the reproducibility of neutron emission of small plasma focus devices

The purpose of this work is to discuss the techniques related to the detection of fast pulsed neutrons produced in plasma focus (PF) devices, the statistical analysis of the corresponding data, and the methodologies for evaluation of the device performance in low emission neutron sources. A general mathematical framework is presented for the assessment of the reproducibility of the neutron emission of small PF devices given the shot-to-shot distribution and detector efficiency. The effect on the reproducibility in case of using two independent detectors is also discussed. The analysis is applied to the neutron emission of the plasma focus device PF-50J operating in repetitive mode (0.1-0.5 Hz and 65 J bank energy).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coded aperture imaging of fusion source in a plasma focus operated with pure D{sub 2} and a D{sub 2}-Kr gas admixture

The coded aperture imaging (CAI) technique has been used to investigate the spatial distribution of DD fusion in a 1.6 kJ plasma focus (PF) device operated in, alternatively, pure deuterium or deuterium-krypton admixture. The coded mask pattern is based on a singer cyclic difference set with 25% open fraction and positioned close to 90 Degree-Sign to the plasma focus axis, with CR-39 detectors used to register tracks of protons from the D(d, p)T reaction. Comparing the coded aperture imaging proton images for pure D{sub 2} and D{sub 2}-Kr admixture operation reveals clear differences in size, density, and shape between the fusion sources for these two cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of non-stationary self-focusing of intense laser pulse in cold quantum plasma using ramp density profile

The authors have investigated the non-stationary self-focusing of Gaussian laser pulse in cold quantum plasma. In case of high dense plasma, the nonlinearity in the dielectric constant is mainly due to relativistic high intense interactions and quantum effects. In this paper, we have introduced a ramp density profile for plasma and presented graphically the behavior of spot size oscillations of pulse at rear and front portions of the pulse. It is observed that the ramp density profile and quantum effects play a vital role in stronger and better focusing at the rear of the pulse than at the front in cold quantum plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focused electron beam in pyroelectric electron probe microanalyzer

We report a method to focus the electron beam generated using a pyroelectric crystal. An electron beam with a spot size of 100 μm was achieved by applying an electrical field to an electroconductive needle tip set on a pyroelectric crystal. When the focused electron beam bombarded a sample, characteristic X-rays of the sample were only detected due to the production of an electric field between the needle tip and the sample.

43 PARTICLE ACCELERATORS↗

The role of the gas/plasma plume and self-focusing in a gas-filled capillary discharge waveguide for high-power laser-plasma applications

The role of the gas/plasma plume at the entrance of a gas-filled capillary discharge plasma waveguide in increasing the laser intensity has been investigated. Distinction is made between neutral gas and hot plasma plumes that, respectively, develop before and after discharge breakdown. Time-averaged measurements show that the on-axis plasma density of a fully expanded plasma plume over this region is similar to that inside the waveguide. Above the critical power, relativistic and ponderomotive self-focusing lead to an increase in the intensity, which can be nearly a factor of 2 compared with the case without a plume. When used as a laser plasma wakefield accelerator, the enhancement of intensity can lead to prompt electron injection very close to the entrance of the waveguide. Self-focusing occurs within two Rayleigh lengths of the waveguide entrance plane in the region, where the laser beam is converging. Analytical theory and numerical simulations show that, for a density of 3.0 × 10{sup 18} cm{sup −3}, the peak normalized laser vector potential, a{sub 0}, increases from 1.0 to 1.85 close to the entrance plane of the capillary compared with a{sub 0} = 1.41 when the plume is neglected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-focusing of a high current density ion beam extracted with concave electrodes in a low energy region around 150 eV

Spontaneous self-focusing of ion beam with high current density (J{sub c} ∼ 2 mA/cm{sup 2}, I{sub b} ∼ 65 mA) in low energy region (∼150 eV) is observed in a hydrogen ion beam extracted from an ordinary bucket type ion source with three electrodes having concave shape (acceleration, deceleration, and grounded electrodes). The focusing appears abruptly in the beam energy region over ∼135–150 eV, and the J{sub c} jumps up from 0.7 to 2 mA/cm{sup 2}. Simultaneously a strong electron flow also appears in the beam region. The electron flow has almost the same current density. Probably these electrons compensate the ion space charge and suppress the beam divergence.

43 PARTICLE ACCELERATORS↗

Study on electron beam in a low energy plasma focus

Electron beam emission was investigated in a low energy plasma focus device (2.2 kJ) using copper hollow anode. Faraday cup was used to estimate the energy of the electron beam. XR100CR X-ray spectrometer was used to explore the impact of the electron beam on the target observed from top-on and side-on position. Experiments were carried out at optimized pressure of argon gas. The impact of electron beam is exceptionally notable with two different approaches using lead target inside hollow anode in our plasma focus device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and characterization of electron beam focusing for X-ray generation in novel medical imaging architecture

A novel electron beam focusing scheme for medical X-ray sources is described in this paper. Most vacuum based medical X-ray sources today employ a tungsten filament operated in temperature limited regime, with electrostatic focusing tabs for limited range beam optics. This paper presents the electron beam optics designed for the first distributed X-ray source in the world for Computed Tomography (CT) applications. This distributed source includes 32 electron beamlets in a common vacuum chamber, with 32 circular dispenser cathodes operated in space charge limited regime, where the initial circular beam is transformed into an elliptical beam before being collected at the anode. The electron beam optics designed and validated here are at the heart of the first Inverse Geometry CT system, with potential benefits in terms of improved image quality and dramatic X-ray dose reduction for the patient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Summary of recent experiments on focusing of target-normal-sheath-accelerated proton beam with a stack of conducting foils

We present a summary of recent experiments on focusing of laser target-normal-sheath-accelerated (TNSA) proton beam with a stack of thin conducting foils. The experiments were performed using the Phelix laser (GSI-Darmstadt) and the Titan laser, Lawrence Livermore National Laboratory. The phenomena consistent with self-collimation (or weak self-focusing) of TNSA protons were experimentally observed for the first time at the Phelix laser user facility, in a specially engineered structure ('lens') consisting of a stack of 300 thin aluminum foils separated by 50 μm vacuum gaps. Follow up experiments using the Titan laser obtained results consistent with the collimation/focusing observed in the initial experiments using the Phelix. The Titan experiments employed improved, 25 μm- and 50 μm-gap targets and the new fine mesh diagnostic. All the experiments were carried out in a “passive environment,” i.e., no external fields were applied, and no neutralization plasma or injection of secondary charged particles was imposed. A plausible interpretation of the observed phenomena is that the combination of magnetic self-pinch forces generated by the beam current together with the simultaneous reduction of the repulsive electrostatic forces due to the conducting foils inhibits radial expansion of the beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Response to “Comment on ‘Stationary self-focusing of Gaussian laser beam in relativistic thermal quantum plasma’” [Phys. Plasmas 21, 064701 (2014)]

Habibi and Ghamari have presented a Comment on our paper [Phys. Plasmas 20, 072703 (2013)] by examining quantum dielectric response in thermal quantum plasma. They have modeled the relativistic self-focusing of Gaussian laser beam in cold and warm quantum plasmas and reported that self-focusing length does not change in both situations. In this response, we have reached the following important conclusions about the comment itself.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗