Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Feedback Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Control method and system for hydraulic machines employing a dynamic joint motion model

A control method and system for controlling a hydraulically actuated mechanical arm to perform a task, the mechanical arm optionally being a hydraulically actuated excavator arm. The method can include determining a dynamic model of the motion of the hydraulic arm for each hydraulic arm link by relating the input signal vector for each respective link to the output signal vector for the same link. Also the method can include determining an error signal for each link as the weighted sum of the differences between a measured position and a reference position and between the time derivatives of the measured position and the time derivatives of the reference position for each respective link. The weights used in the determination of the error signal can be determined from the constant coefficients of the dynamic model. The error signal can be applied in a closed negative feedback control loop to diminish or eliminate the error signal for each respective link.

42 ENGINEERING↗

Catalyst Ammonia Storage Measurements Using Radio Frequency Sensing1

Motivated by increasingly strict nitrogen oxides (NOx) limits, engine manufacturers have adopted selective catalytic reduction (SCR) technology to reduce engine-out NOx. In the SCR process, NOx react with ammonia (NH3) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NOx and/or NH3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF)-based method to directly monitor the ammonia storage state of the SCR. This approach utilizes the catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH3) were evaluated over a wide range of frequencies, temperatures, and exhaust conditions. The RF response to NH3 storage, desorption, and oxidation on the SCR was well correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10% of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NOx conversion and decrease urea consumption.

Engineering↗

Harnessing on-machine metrology data for prints with a surrogate model for laser powder directed energy deposition

In this study, we leverage the massive amount of multi-modal on-machine metrology data generated from Laser Powder Directed Energy Deposition (LP-DED) to construct a comprehensive surrogate model of the 3D printing process. By employing Dynamic Mode Decomposition with Control (DMDc), a data-driven technique, we capture the complex physics inherent in this extensive dataset. This physics-based surrogate model emphasizes thermodynamically significant quantities, enabling us to accurately predict key process outcomes. The model ingests 21 process parameters, including laser power, scan rate, and position, while providing outputs such as melt pool temperature, melt pool size, and other essential observables. Furthermore, it incorporates uncertainty quantification to provide bounds on these predictions, enhancing reliability and confidence in the results. We then deploy the surrogate model on a new, unseen part and monitor the printing process as validation of the method. Our experimental results demonstrate that the predictions align with actual measurements with high accuracy, confirming the effectiveness of our approach. Furthermore, this methodology not only facilitates real-time predictions but also operates at process-relevant speeds, establishing a basis for implementing feedback control in LP-DED.

Digital twins↗

CATALYST AMMONIA STORAGE MEASUREMENTS USING RADIO FREQUENCY SENSING

Motivated by increasingly strict NO x limits, engine manufactures have adopted selective catalytic reduction (SCR) technology to reduce engine-out NO x below mandated levels. In the SCR process, nitrogen oxides (NO x ) react with ammonia (NH 3 ) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NO x and/or NH 3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF) -based method to directly monitor the ammonia storage state of the SCR catalyst. This approach utilizes the SCR catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH 3 ) were evaluated over a wide frequency range as well as temperature and exhaust conditions. The RF response to NH 3 storage, desorption, and oxidation on the SCR was observed to be well-correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10 % of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NO x conversion and decrease urea consumption.

Aguilar, Jonathan↗

Design and implementation of a 150 GHz single-channel millimeter wave interferometer on Joint TEXT tokamak

A simple, single-channel millimeter-wave interferometer system has been designed, fabricated, and installed on the J-TEXT tokamak. For the plasma density anticipated on J-TEXT, a solid-state source operating at 150 GHz has been chosen to minimize errors due to both vibration along the beam path and refraction in the plasma. The new aspect of the interferometer design is to use a subharmonic mixer for detection with a frequency doubled 150 GHz source. It employs a single source which is bias-tuned and modulated with a sawtooth wave form up to 100 kHz in order to generate the intermediate frequency. The 12.5 GHz voltage-controlled oscillator is multiplied to 75 GHz before a final doubler raises it to 150 GHz. A portion of the 75 GHZ power is used for the local oscillator (LO) and is directly connected to the LO input of the subharmonic mixer. The phase is evaluated by a digital phase comparator using a software-based algorithm. Detection noise limits the minimum resolvable phase change with the interferometer to {+-}0.05 fringe, which corresponds to an averaged electron density change along the chord of {+-}1.1 Multiplication-Sign 10{sup 17} m{sup -2}. The maximum measurable electron density is expected to be {approx}9 Multiplication-Sign 10{sup 19} m{sup -3}. A comparison of preliminary results from the millimeter wave interferometer with that from the far-infrared hydrogen cyanide laser (wavelength of 337 {mu}m) interferometer shows good agreement during the pulse flat-top period. The millimeter wave interferometer system will be used as a part of the density feedback control system in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Modeling of Cold Crucible Induction Melting for Process Control and Optimization

The Idaho National Laboratory (INL) and the St. Petersburg Electrotechnical University 'LETI' (ETU) have collaborated on development and validation of an advanced numerical model of the cold crucible induction melting (CCIM) process. This work was conducted in support of the Department of Energy (DOE) Office of Environmental Management Technology and Engineering (EM-20) International Program. The model predicts quasi-steady state temperature distributions, convection cell configurations, and flow field velocities for a fully established melt of low conductivity non-magnetic materials at high frequency operations. The INL/ETU ANSYS{sup C} finite element model is unique in that it has been developed specifically for processing borosilicate glass (BSG) and other glass melts. Specifically, it accounts for the temperature dependency of key material properties, some of which change by orders of magnitude within the temperature ranges experienced (temperature differences of 500 deg. C are common) in CCIM processing of glass, including density, viscosity, thermal conductivity, specific heat, and electrical resistivity. These values, and their responses to temperature changes, are keys to understanding the melt characteristics. Because the model has been validated, it provides the capability to conduct parametric studies to understand operational sensitivities and geometry effects. Additionally, the model can be used to indirectly determine difficult to measure material properties at higher temperatures such as resistivity, thermal conductivity and emissivity. The model can also be used to optimize system design and to predict operational behavior for specific materials and system configurations, allowing automated feedback control. This becomes particularly important when designing melter systems for full-scale industrial applications. (authors)

42 ENGINEERING↗

Improving precision in resonance ionization mass spectrometry : influence of laser bandwidth in uranium isotope ratio measurements.

The use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of {sup 235}U/{sup 238}U ratios by resonance ionization mass spectrometry (RIMS) to decrease laser-induced isotopic fractionation. By broadening the bandwidth of the first laser in a three-color, three-photon ionization process from a bandwidth of 1.8 GHz to about 10 GHz, the variation in sequential relative isotope abundance measurements decreased from 10% to less than 0.5%. This procedure was demonstrated for the direct interrogation of uranium oxide targets with essentially no sample preparation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resonance ionization mass spectrometry for precise measurements of iostope ratios.

Resonance ionization mass spectrometry offers extremely high sensitivity and elemental selectivity in microanalysis, but the isotopic precision attainable by this technique has been limited. Measured isotope ratios are sensitive to small fluctuations in the pointing, pulse timing, and wavelength of the resonance lasers. We show that, by minimizing these fluctuations using feedback controls and by power-broadening the optical transitions, we are able to measure chromium isotope ratios with statistics-limited precision better than 1%. Small additional improvements in reproducibility come from careful shaping of the electric field in the region where atoms are photoionized and from minimizing pulse-to-pulse variations in the time-of-flight mass spectrometer through which the photoions travel. The increased reproducibility of isotopic measurements on standard materials has enabled us to detect anomalous chromium isotopic abundances in presolar SiC grains extracted from primitive meteorites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Measurement of Ammonia Storage on Passive SCR Systems for Lean Gasoline NOx Reduction Using Radio Frequency Sensing

Lean gasoline engine operation provides clear efficiency benefits relative to conventional stoichiometric combustion approaches. One of the key hurdles to the widespread, practical implementation of lean gasoline combustion remains the challenge of lean NOx control. One of the potential approaches for controlling NOx emission from lean gasoline engines is the so-called passive selective catalytic reduction (SCR) system. In such systems, periods of rich operation generate ammonia over a three-way catalyst (TWC), which is then adsorbed on the downstream SCR and consumed during lean operation. Brief periods of rich operation must occur in response to the depletion of stored ammonia on the SCR, which requires reliable measurements of the SCR ammonia inventory. Presently, lean exhaust system controls rely on a variety of gas sensors mounted up- and downstream of the catalysts, and which only provide an indirect inference of the operation state.In this study, a radio frequency (RF) sensor was used to provide a direction measurement of the amount of ammonia adsorbed on the SCR in real-time. The RF sensor was calibrated and deployed on a BMW N43B20 4-cylinder lean gasoline engine equipped with a passive SCR system. Brief periods of rich operation performed at lambda values between 0.98 and 0.99 generated the ammonia, subsequently stored on the SCR for consumption during periods of lean operation. The experiments compared real-time measurements of SCR ammonia inventory from the RF sensor with estimates of ammonia coverage derived from exhaust gas composition measurements upstream and downstream of the catalyst. The results showed a high degree of correlation between the RF measurements and SCR ammonia storage inventory, and demonstrated NOx conversion efficiencies above 98%, confirming the feasibility of the concept. Relative to stoichiometric operation, lean-gasoline operation resulted in fuel efficiency gains of up to 10%, which may be further improved through direct feedback control from the RF sensor to optimize lean–rich cycling based on actual, measured SCR ammonia levels.

Ragaller, Paul↗

A two-axis in-plane motion measurement system based on optical beam deflection

Measurement of in-plane motion with high resolution and large bandwidth enables model-identification and real-time control of motion-stages. This paper presents an optical beam deflection based system for measurement of in-plane motion of both macro- and micro-scale motion stages. A curved reflector is integrated with the motion stage to achieve sensitivity to in-plane translational motion along two axes. Under optimal settings, the measurement system is shown to theoretically achieve sub-angstrom measurement resolution over a bandwidth in excess of 1 kHz and negligible cross-sensitivity to linear motion. Subsequently, the proposed technique is experimentally demonstrated by measuring the in-plane motion of a piezo flexure stage and a scanning probe microcantilever. For the former case, reflective spherical balls of different radii are employed to measure the in-plane motion and the measured sensitivities are shown to agree with theoretical values, on average, to within 8.3%. For the latter case, a prototype polydimethylsiloxane micro-reflector is integrated with the microcantilever. The measured in-plane motion of the microcantilever probe is used to identify nonlinearities and the transient dynamics of the piezo-stage upon which the probe is mounted. These are subsequently compensated by means of feedback control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of ITER 15 MA ELMy H-mode Inductive Scenario

The poloidal field (PF) coil system on ITER, which provides both feedforward and feedback control of plasma position, shape, and current, is a critical element for achieving mission performance. Analysis of PF capabilities has focused on the 15 MA Q = 10 scenario with a 300-500 s flattop burn phase. The operating space available for the 15 MA ELMy H-mode plasma discharges in ITER and upgrades to the PF coils or associated systems to establish confidence that ITER mission objectives can be reached have been identified. Time dependent self-consistent free-boundary calculations were performed to examine the impact of plasma variability, discharge programming, and plasma disturbances. Based on these calculations a new reference scenario was developed based upon a large bore initial plasma, early divertor transition, low level heating in L-mode, and a late H-mode onset. Equilibrium analyses for this scenario indicate that the original PF coil limitations do not allow low li (<0.8) operation or lower flux states, and the flattop burn durations were predicted to be less than the desired 400 s. This finding motivates the expansion of the operating space, considering several upgrade options to the PF coils. Analysis was also carried out to examine the feedback current reserve required in the CS and PF coils during a series of disturbances and a feasibility assessment of the 17 MA scenario was undertaken. Results of the studies show that the new scenario and modified PF system will allow a wide range of 15 MA 300-500 s operation and more limited but finite 17 MA operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of MHD stability and active mode control on KSTAR for high confinement, disruption-free plasma

Long-pulse plasma operation at high normalized beta, $β_N$, above the $\textit{n}$= 1 ideal MHD no-wall stability limit in KSTAR is presently limited by tearing instabilities rather than resistive wall modes. H-mode plasma operation during the recent KSTAR device campaign produced discharges having strong $\textit{m/n}$= 2/1 tearing instabilities at $β_N$ lower than the ideal MHD no-wall beta limit. The unstable tearing mode consequently reduced plasma confinement and toroidal plasma rotation significantly. We report the experiment confirmed that an extended duration of electron cyclotron heating (ECH) at the initial phase of the discharge plays a critical role in mode destabilization. To study destabilizing mechanisms that affect the mode growth, the stability of the observed tearing modes from plasmas with significantly different $β_N$ is computed by using the resistive DCON code and the M3D-C 1 code. Equilibrium reconstructions that include constraints from internal profile diagnostics, and computed fast particle pressure are used as input for reliable computation of stability. The classical tearing stability index, Δ', from resistive DCON is computed to be unstable when the island is fully saturated with large amplitude, while the unstable mode is not computed by M3D-C 1 . The modified Rutherford equation (MRE) describing the evolution of the island width has been constructed for KSTAR plasmas by using plasma parameters computed by the TRANSP code. The MRE model estimates a saturated island width corresponding to ~10% of the plasma minor radius for equilibrium at high $β_N$ 3 having a stable Δ' from the resistive DCON. In preparation for long-pulse plasma operation at higher beta utilizing increased plasma heating power, a resistive wall mode (RWM) active feedback control algorithm has been completed and enabled on KSTAR. To accurately determine the $\textit{n}$= 1component produced by RWMs, an algorithm has been developed that includes magnetic sensor compensation of the prompt applied field and the field from the induced current on the passive conductors. Use of multiple toroidal sensor arrays is enabled by modifying the sensor toroidal angles assumed in mode decomposition to include the effect of varied mode helicities in the outboard region where the mode measurement is made. This analysis on stability, transport, and control provides the required foundation for disruption prediction and avoidance research on KSTAR.

resistive wall mode (RWM)↗

A reduced-order modeling of a tubular solar reactor for long duration thermochemical energy storage

The storage of solar energy in a solid form, referred to as a “solar fuel”, can be achieved through a process known as endothermic solar thermochemistry. This process transforms the absorbed solar energy into a stable and retrievable form that can be stored for extended periods of time. This paper presents a low–order heat transfer model of a counter–current tubular falling bed reactor designed to produce thermally reduced magnesium manganese oxide pellets for long duration thermochemical energy storage. The energy required for the endothermic reduction was supplied by concentrated solar energy or renewable electricity via indirect heating of the gas and solid reactants flowing in a ceramic tube. The counter-current gas flow enhances the mixing of the solid particles with the heat recuperation zone, allowing the gas and particles to enter and exit the tubular reactor close to room temperature. Further, the reactor was vertically oriented and was heated circumferentially by an adjustable level heat flux along a finite segment of its length. The temperature distribution of the reactor in response to transient changes along the tube was modeled by considering conduction, convection, and radiation heat transfer. Governing equations for the heat transfer model were solved by discretizing the reactor tube into a finite number of control volumes and using an energy balance for the heat exchange between the reactor wall, gas, and particles within the control volume. The energy absorbed during this endothermic reaction was modeled numerically by fitting the data of the chemical conversion rate with the corresponding temperature of particles in the heating zone. The numerical model has been experimentally validated using a reactor prototype made of a 121.92 cm alumina tube heated by a 7kW electric tube–furnace. The alumina tube receives magnesium manganese oxide pellets of 3.66±0.516 mm in diameter from the top, and a counter–current gas flow from the bottom. The reactor wall temperature was monitored by six thermocouples installed along the reactor tube length. The experimental procedure was numerically simulated, and the temperature variation along the reactor tube was compared with a matrix of experimental runs for a range of particles mass flowrates (0.75–1.25g/s) and corresponding gas flowrates (36–65 SLPM). The reactor system was heated gradually from room temperature to a steady state temperature of 1673K, and then cooled down to room temperature. The heating and cooling processes were simulated, and the numerical and experimental results were compared throughout processes. The numerical model showed similar trends to the experimental results, with an error of 0.69 to 7.9% for the particle inlet and 0.7 to 7.9% for the gas inlet during steady-state operation. The proposed numerical model can be implemented as a simplified physical model to design a feedback control system to regulate reactor temperature.

14 SOLAR ENERGY↗

Quantifying Uranium Isotope Ratios Using Resonance Ionization Mass Spectrometry: The Influence of Laser Parameters on Relative Ionization Probability

Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure relative uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process to provide a distinction between uranium atoms and potential isobars without the aid of chemical purification and separation. We explore the laser parameters critical to the ionization process and their effects on the measured isotope ratio. Specifically, the use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of 235 U/ 238 U ratios to decrease laser-induced isotopic fractionation. By broadening the bandwidth of the first laser in a 3-color, 3-photon ionization process from a bandwidth of 1.8 GHz to about 10 GHz, the variation in sequential relative isotope abundance measurements decreased from >10% to less than 0.5%. This procedure was demonstrated for the direct interrogation of uranium oxide targets with essentially no sample preparation. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variation in laser parameters on the measured isotope ratio. This work demonstrates that RIMS can be used for the robust measurement of uranium isotope ratios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Revisiting the quantum Szilard engine with fully quantum considerations

By considering level shifting during the insertion process we revisit the quantum Szilard engine (QSZE) with fully quantum consideration. We derive the general expressions of the heat absorbed from thermal bath and the total work done to the environment by the system in a cycle with two different cyclic strategies. We find that only the quantum information contributes to the absorbed heat, and the classical information acts like a feedback controller and has no direct effect on the absorbed heat. This is the first demonstration of the different effects of quantum information and classical information for extracting heat from the bath in the QSZE. Moreover, when the well width L{yields}{infinity} or the temperature of the bath T{yields}{infinity} the QSZE reduces to the classical Szilard engine (CSZE), and the total work satisfies the relation W{sub tot}=k{sub B}Tln2 as obtained by Sang Wook Kim et al. [S.W. Kim, T. Sagawa, S. De Liberato, M. Ueda, Phys. Rev. Lett. 106 (2011) 070401] for one particle case. - Highlights: Black-Right-Pointing-Pointer For the first time analyze the QSZE by considering energy level shifts. Black-Right-Pointing-Pointer Find different roles played by classical and quantum information in the QSZE. Black-Right-Pointing-Pointer The amount of work extracted depends on the cyclic strategies of the QSZE. Black-Right-Pointing-Pointer Verify that the QSZE will reduce to the CSZE in the classical limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Fabrication of a Radiation-Hard 500-MHz Digitizer Using Deep Submicron Technology

The proposed International Linear Collider (ILC) will use tens of thousands of beam position monitors (BPMs) for precise beam alignment. The signal from each BPM is digitized and processed for feedback control. We proposed the development of an 11-bit (effective) digitizer with 500 MHz bandwidth and 2 G samples/s. The digitizer was somewhat beyond the state-of-the-art. Moreover we planned to design the digitizer chip using the deep-submicron technology with custom transistors that had proven to be very radiation hard (up to at least 60 Mrad). The design mitigated the need for costly shielding and long cables while providing ready access to the electronics for testing and maintenance. In FY06 as we prepared to submit a chip with test circuits and a partial ADC circuit we found that IBM had changed the availability of our chosen IC fabrication process (IBM 6HP SiGe BiCMOS), making it unaffordable for us, at roughly 3 times the previous price. This prompted us to change our design to the IBM 5HPE process with 0.35 µm feature size. We requested funding for FY07 to continue the design work and submit the first prototype chip. Unfortunately, the funding was not continued and we will summarize below the work accomplished so far.

43 PARTICLE ACCELERATORS↗

Quantitative comparison of two independent lateral force calibration techniques for the atomic force microscope

Two independent lateral-force calibration methods for the atomic force microscope (AFM)--the hammerhead (HH) technique and the diamagnetic lateral force calibrator (D-LFC)--are systematically compared and found to agree to within 5% or less, but with precision limited to about 15%, using four different tee-shaped HH reference probes. The limitations of each method, both of which offer independent yet feasible paths toward traceable accuracy, are discussed and investigated. We find that stiff cantilevers may produce inconsistent D-LFC values through the application of excessively high normal loads. In addition, D-LFC results vary when the method is implemented using different modes of AFM feedback control, constant height and constant force modes, where the latter is more consistent with the HH method and closer to typical experimental conditions. Specifically, for the D-LFC apparatus used here, calibration in constant height mode introduced errors up to 14 %. In constant force mode using a relatively stiff cantilever, we observed an {approx_equal} 4 % systematic error per {mu}N of applied load for loads {<=} 1 {mu}N. The issue of excessive load typically emerges for cantilevers whose flexural spring constant is large compared with the normal spring constant of the D-LFC setup (such that relatively small cantilever flexural displacements produce relatively large loads). Overall, the HH method carries a larger uncertainty, which is dominated by uncertainty in measurement of the flexural spring constant of the HH cantilever as well as in the effective length dimension of the cantilever probe. The D-LFC method relies on fewer parameters and thus has fewer uncertainties associated with it. We thus show that it is the preferred method of the two, as long as care is taken to perform the calibration in constant force mode with low applied loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗