Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fault Injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Big Hill Geomechanical Analysis Using M-D Viscoplastic Material Model

The integrity of wellbores at the interbed between the caprock and salt is a serious concern in the Big Hill site. For the remediation and life extension of wellbores, more accurate predictions from the global model are needed. The Big Hill global model is improved using the M-D viscoplastic contact surface model and the mesh containing the interbed layer with contact surfaces between the salt and caprock layers, and fault blocks in overburden and caprock layers. The model calibration has been performed based on the cavern volumetric closures obtained from the Caveman calculations. The results agree well from 1991 to the early 2000s. The difference starts to widen after that, it might be because of frequent fluid movement and raw water injection. Therefore, the predictions from this improved model could be used to examine the structural integrity of caverns in Big Hill salt dome.

42 ENGINEERING↗

Measurement-based Coherency Identification and Aggregation for Power Systems

In power system model reduction, a high reduction ratio is often desired to handle much more complex power systems. The bottleneck of traditional methods lies in: Coherency identification methods are conservative. Some coherency generators are not detected when system topology or operating points change, because coherency identification depends on system topology or operating points. There are some solitary generators in external systems. These generators do not belong to any coherency group. However, sometimes these solitary generators have little impact on tie-line power flow, and it might be possible to ignore their dynamics in model reduction. But because they do not belong to any coherency group, existing reduction methods cannot handle them well. In order to overcome the first problem, a measurement-based online coherency identification method is presented in this paper. By analyzing post-fault trajectories measured by Phasor Measurement Units (PMUs), coherency generators are identified through principal component analysis. The method can track time-varying system topology and operating points. In order to address the second problem, this paper introduces sensitivity analysis into traditional reduction methods. The sensitivity of tie-line power flow against injected active power of external system generators is derived. Those generators having loose connection with tie-line power are identified through the sensitivity analysis, and their dynamics are ignored by replacing them with negative impedances. We test if the sensitivity, based on static power flow, provides good guidance to reduce the dynamic model. Case studies show that the proposed method can handle well these solitary generators and the reduction ratio can be enhanced through this method. Future work will include generalization of the sensitivity method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Hydrogeologic Characterization Results from the Wallula Basalt Pilot Study

The DOE's Big Sky Regional Carbon Sequestration Partnership has completed drilling the first continental flood basalt sequestration pilot borehole to a total depth (TD) of 4,110 feet on the Boise White Paper Mill property at Wallula, Washington. Site suitability was assessed prior to drilling by the 2007-2008 acquisition, processing and analysis of a four-mile, five-line three component seismic swath, which was processed as a single data-dense line. Analysis of the seismic survey data indicated a composite basalt formation thickness of {approx}8,000 feet and absence of major geologic structures (i.e., faults) along the line imaged by the seismic swath. Drilling of Wallula pilot borehole was initiated on January 13, 2009 and reached TD on April 6, 2009. Based on characterization results obtained during drilling, three basalt breccia zones were identified between the depth interval of 2,716 and 2,910 feet, as being suitable injection reservoir for a subsequent CO2 injection pilot study. The targeted injection reservoir lies stratigraphically below the massive Umtanum Member of the Grande Ronde Basalt, whose flow-interior section possesses regionally recognized low-permeability characteristics. The identified composite injection zone reservoir provides a unique and attractive opportunity to scientifically study the reservoir behavior of three inter-connected reservoir intervals below primary and secondary caprock confining zones. Drill cuttings, wireline geophysical logs, and 31one-inch diameter rotary sidewall cores provided geologic data for characterization of rock properties. XRF analyses of selected rock samples provided geochemical characterizations of the rocks and stratigraphic control for the basalt flows encountered by the Wallula pilot borehole. Based on the geochemical results, the pilot borehole was terminated in the Wapshilla Ridge 1 flow of the Grande Ronde Basalt Formation. Detailed hydrologic test characterizations of 12 basalt interflow reservoir zones and 3 flow-interior/caprock intervals were performed during drilling and immediately following reaching the final borehole drilling depth (i.e., 4,110 ft). In addition, six of the 12 basalt interflow zones were selected for detailed hydrochemical characterization. Results from the detailed hydrologic test characterization program provided the primary information on basalt interflow zone transmissivity/injectivity, and caprock permeability characteristics.

58 GEOSCIENCES↗

Experimental study of fracture slip due to stress perturbation in fractured geo-resources

Anthropogenic activities such as underground fluid injection/extraction, well stimulation, and dam impoundment will perturb the state-of-stress in the subsurface, which could activate critically stressed pre-existing fractures and faults. Fault and fracture activation can induce seismicity, change flow behavior, and damage asperities on the fracture surface to alter reservoir permeability. Here, in this study, triaxial shear tests were conducted on saw cut and rough fracture Barre granite specimens to better characterize how a decrease in normal stress and increase in shear stress will influence crystalline rock fracture hydromechanical properties. In a triaxial set up, confining pressure (CP) and differential stress (DS) were used to induce normal and shear stress on a 45° oriented fracture. Fracture slip and the corresponding stress relaxation was observed when the confining stress decreased. Fracture permeability increased when the fracture slipped. Moreover, new micro-cracks observed by x-ray images indicated the creation of new flow paths for fluid movement. The experimental outcomes of this study indicate that decrease in normal stress due to stress perturbations along the faults/fractures in the extensional stress regime can induce the slip along the fracture. This could have a significant influence on slope stability in quarries, stimulation and injection strategy in deep geo-resources, and potentially minimize the risk of induced seismicity. The observed stress dependency of hydraulic aperture in rough fracture during pre- and post-slip stages could provide key inputs for field-scale simulation of geo-resources.

58 GEOSCIENCES↗

Interpretation of Tracer Experiments on Inverted Five-spot Well-patterns within the Western Half of the Farnsworth Unit Oil Field

The Southwest Carbon Partnership (SWP), one of the U.S. Department of Energy (U.S. DOE) seven Regional Carbon Sequestration Partnerships, is currently working to demonstrate the utilization and storage of CO 2 in the Farnsworth Unit (FWU) Enhanced Oil Recovery (EOR) site under the final development phase of this U.S. DOE initiative. A component of the research is to use fluid tracers to understand the multifluid flow patterns that develop between injection and production wells via collected field data and supporting numerical reservoir models. The FWU, located in the Anadarko Basin, Ochiltree County, Texas, and being operated by Chaparral Energy, is a mature EOR water-flood field, which is currently being converted to a CO 2 flow, with inverted 5-spot patterns transitioning from pure water to alternating CO 2 and water floods (i.e., water alternating gas (WAG)) at an approximate rate of one every 6 to 10 months. The SWP tracer program is conducting a suite of tracer injections into the active 5-spot patterns at the FWU. Tracers have been selected to be nonreactive and either principally soluble in CO 2 (gas soluble) or water (aqueous soluble). In addition to characterizing the multifluid flow behaviour within reservoir, the gas and aqueous tracers have roles in detecting any leakage from the reservoir. A total of seven unique perfluorocarbon tracer (PFT) compounds make up the suite of gas soluble tracers and eight unique naphthalene sulfonate tracer (NPT) compounds comprise the aqueous soluble tracers. Lastly, all selected tracers are significantly detectable below the parts per billion concentrations, allowing for high resolution for the inter-well tests at relatively low injection volumes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neutron irradiation-induced microstructure damage in ultra-high temperature ceramic TiC

Titanium carbide (TiC) is an ultra-high temperature ceramic with potential as a structural material candidate for advanced reactor concepts. However, the irradiation tolerance of TiC is not well understood. Here, we reveal the key irradiation damage microstructure degradation processes in TiC using mixed spectrum neutron irradiations at dose of ~2 displacements per atom (dpa) at temperatures of ~220, 620, and 1115 °C, combined with state-of-art microstructure characterization using transmission electron microscopy (TEM) and high-resolution TEM (HRTEM). The helium injection (~65 atomic parts per million) produced by neutron transmutation also occurred in the sample. TiC was observed to form irradiation-induced interstitial-type dislocation loops and He-stabilized cavities. At 220 and 620 °C, the analysis of the electron diffraction patterns, rel-rod imaging and HRTEM revealed that the dislocation loops were faulted Frank loops with Burgers vector b Frank = 1/3<111> lying on {111} planes. A detailed Burgers vector identification performed by the g.b technique revealed that the dislocation loops forming at 1115 °C were unfaulted, edge-type, with Burgers vectors b = a<100> and a/2<110> with corresponding {100} and {110} habit planes. Using continuum mechanics, we estimated the critical radius at which a faulted dislocation loop transitions to a perfect loop to be 9 nm. Further, no amorphization occurred in TiC under-investigated irradiation conditions while macroscopic swelling under point defect swelling regime was observed. He-stabilized cavities were detected at 1115 °C, but not at lower temperature irradiation. These observations indicate the onset of long-range vacancy migration in TiC occurs between 620 and 1115 °C.

36 MATERIALS SCIENCE↗

Structure of V-defects in long wavelength GaN-based light emitting diodes

The V-defect is a naturally occurring inverted hexagonal pyramid structure that has been studied in GaN and InGaN growth since the 1990s. Strategic use of V-defects in pre-quantum well superlattices or equivalent preparation layers has enabled record breaking efficiencies for green, yellow, and red InGaN light emitting diodes (LEDs) utilizing lateral injection of holes through the semi-polar sidewalls of the V-defects. In this article, we use advanced characterization techniques such as scattering contrast transmission electron microscopy, high angle annular dark field scanning transmission electron microscopy, x-ray fluorescence maps, and atom probe tomography to study the active region compositions, V-defect formation, and V-defect structure in green and red LEDs grown on (0001) patterned sapphire and (111) Si substrates. We identify two distinct types of V-defects. The “large” V-defects are those that form in the pre-well superlattice and promote hole injection, usually nucleating on mixed (Burgers vector b = ±a±c⁠) character threading dislocations. In addition, “small” V-defects often form in the multi-quantum well region and are believed to be deleterious to high-efficiency LEDs by providing non-radiative pathways. The small V-defects are often associated with basal plane stacking faults or stacking fault boxes. Furthermore, we show through scattering contrast transmission electron microscopy that during V-defect filling, the threading dislocation, which runs up the center of the V-defect, will “bend” onto one of the six {10$\overline{1}$1} semi-polar planes. In conclusion, this result is essential to understanding non-radiative recombination in V-defect engineered LEDs.

42 ENGINEERING↗

Center for Frontiers of Subsurface Energy Security (Final Report)

For the past two decades a slowly growing consensus has been that rising temperature is being caused by increases in carbon dioxide (CO 2 ) in the Earth’s atmosphere. What is less consensual is what to do about it. Solutions range from reducing emissions to various ways to capture CO 2 (from effluents of power plants, as plants, etc.) and store it away from the atmosphere. The problem is of such magnitude that it is likely that we will need many methods. Also some methods would cause draconian harm to global economies. This work is about the storage part of the reducing of CO 2 in the atmosphere. There have been many methods proposed for storing CO 2 : in vegetation, at the bottom of oceans, in land farms, and in subsurface formations. The latter is particularly prominent given the large estimated volume in porous formation in the Earth, and the 50-year old experience in injecting CO 2 for enhanced oil recovery. This report is about the science behind subsurface storage, called here geological carbon storage or GCS. Effective GCS requires that billions of metric tons of CO 2 be injected into storage reservoirs annually. GCS feasibility requires balancing the opposing impacts of large emplacement (injection) rates without compromising caprock seal integrity during injection. Once injected, the challenge is to assure the injected CO 2 remains permanently stored. Under most conditions, CO 2 is in a supercritical state, or scCO 2 . scCO 2 is immiscible with the subsurface brine and has a factor of ten smaller viscosity, leading to the development of two-phase fluid flow and scCO 2 bypassing. After the injection of large volumes of scCO 2 , the pore pressure, state of stress, chemical, thermal, and biological steady-state or equilibrium conditions in the subsurface are disrupted, which may lead to unpredictable behavior because the responses to these changes are often non-linear. Current challenges for efficient and reliable scCO 2 storage are: (1) sustaining large injection rates; (2) using available pore space efficiently, and (3) controlling undesired or unexpected behavior, such as scCO 2 leakage. Various aspects of these challenges are addressed by collaborative projects within Center for Frontiers in Subsurface Energy Security (CFSES). Challenge 1 – Sustaining large storage rates. To offset the annual CO 2 emissions of in the United States, ~7 billion metric tons of CO 2 must be injected into the storage reservoirs annually. Injected CO 2 forms a plume that starts spreading, displacing originally resident brine, though inefficiently so. Because of its low viscosity, and buoyant forces, a CO 2 plume rises to the reservoir rock-caprock interface. Injecting large volumes of scCO 2 at sufficiently high rates into subsurface storage formations leads to increases in pore pressures, potential expansion of the reservoir rock, and may result in fracturing of the reservoir rock and/or caprock. CFSES research uses existing and new experimental and modeling approaches to identify chemical-physical controls on the permeability and pore pressure dynamics, anticipating geomechanical (fracturing) events, predicting multi-phase flow patterns and trapping of CO 2 . Challenge 2 – Using pore space with unprecedented efficiency. Since large volumes of scCO 2 are to be stored, the volume available in storage reservoirs must be used efficiently. Storage efficiency is defined as a fraction of pore space occupied by carbon dioxide. Current estimates are that less than 5 percent of available pore volume is available for storage because scCO 2 , having a smaller density and viscosity than reservoir brine, tends to form viscous fingers, and bypass available pore space. This flow regime results in a CO 2 plume spreading over large areas in subsurface. The research goal in Challenge 2 is to advance the fundamental understanding of two-phase flow through porous media, including molecular-to meter- scale experimental and modeling approaches. This work leads to novel strategies to ensure that injected CO 2 occupies more than 5% of the pore space, ideally up to 50%. Challenge 3 – Controlling undesired or unexpected behavior. Following the injection of scCO 2 , the subsurface reservoir re-equilibrates to different physical and chemical states. This re-equilibration in space and time could lead to unexpected and/or undesired behavior: fracturing of reservoir rock and/or caprock, development of preferential flow paths, CO 2 leakage (to the surface or overlaying fresh water reservoirs), induced seismicity, and activation of faults. One of the main research goals of CFSES was to advance the fundamental understanding of how individual chemical and physical processes are coupled. We particularly focused on the chemical-mechanical coupling, and flow-mechanical coupling. We collected experimental and modeling data to determine the temporal and spatial scales of the coupled processes, which may lead to pore collapse caused by creep, activation of fractures and faults, chemically-induced fracture propagation, and self-focusing of scCO 2 flow.

54 ENVIRONMENTAL SCIENCES↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

GeoThermalCloud: Cloud Fusion of Big Data and Multi-Physics Models using Machine Learning for Discovery, Exploration, and Development of Hidden Geothermal Resources

The primary goals of this project are exploring hidden geothermal resources in the U.S.A. and designing profitable enhanced geothermal systems (EGS). Many processes and parameters control geothermal exploration and energy production from geothermal fields. Diverse datasets (e.g., geology, geochemistry, geophysics, satellite, airborne geophysics) are available to help characterize subsurface geothermal conditions. Sparse and multi-scale characteristics of these datasets prohibit properly leveraging these datasets for geothermal exploration and profitable EGS design. Recent advancements in machine learning (ML) promise to resolve these issues. The tremendous challenges and risks of geothermal exploration and production bring the demand for novel ML methods and tools that can (1) analyze large field datasets, (2) assimilate model simulations (large inputs and outputs), (3) process sparse datasets, (4) perform transfer learning (between sites with different exploratory levels), (5) extract hidden geothermal signatures in the field and simulation data, (6) label geothermal resources and processes, (7) identify high-value data acquisition targets, and (8) guide geothermal exploration and production by selecting optimal exploration, production, and drilling strategies. To address these necessities, ML-based geothermal resources exploration and enhanced geothermal systems (EGS) design tools have been developed. The exploration tool is called GeoThermalCloud and EGS design tool is called GeoDT-ML. GeoThermalCloud (https://github.com/SmartTensors/GeoThermalCloud.jl) utilizes a LANL unsupervised ML platform called SmartTensors (https://tensors.lanl.gov/) to automate data analyses and interpretations by extracting hidden signatures to identify geothermal prospects. Also, it enables the identification of critical measurements needed to identify geothermal resource signatures. Alternatively, GeoDT-ML (https://github.com/SmartTensors/GeoThermalCloud.jl/tree/master/EGS) is an ML-based alternative to GeoDT (https://github.com/GeoDesignTool/GeoDT.git), a fast, simplified multi-physics solver to evaluate EGS project designs in uncertain geologic systems. GeoDT-ML leverages recent advances in deep learning and high-performance computing. It is a faster and simpler version of GeoDT. To make this project a success, we used capabilities of LANL, PNNL, Google, Stanford, and Julia Computing. We analyzed eight datasets of the U.S.A. using GeothermalCloud and demonstrated potential highly prospective geothermal resources and identified key factors defining highly prospective sites. The first data set includes 44 locations in southwest New Mexico and 18 geological, hydrogeological, geophysical, geothermal, geochemical attributes. We defined low- and medium-temperature hydrothermal systems and discovered a new highly prospective site. The second data set analyzed 18 shallow water chemistry attributes at 14,342 locations in the Great Basin. It demarcated modestly, moderately, and highly prospective sites including key attributes for each type of prospectivity. The third data set analyzed Utah FORGE data including satellite (InSAR), geophysical (gravity, seismic), geochemical, and geothermal attributes. Here, we performed prospectivity analysis to identify future drilling locations using geological, geochemical, and geophysical attributes. Maps of temperature at depth and heat flow are constructed based on the available data. Prospectivity maps were generated, and drilling locations were proposed for future geothermal field exploration. The fourth data set analyzed 21 attributes at 120 locations in Tularosa Basin, New Mexico; data comes from past play fairway analyses in this region. ML analyses identified geothermal signatures associated with modestly, moderately, and highly hydrothermal systems. We also defined dominant attributes and spatial distribution of the geothermal signatures. The fifth, sixth, seventh, and eighth datasets include Tohatchi Springs, New Mexico, Hawaii, Brady site, Nevada, and EGS Collab, respectively. Moreover, we coupled GeothermalCloud and magnetotellurics data to pinpoint drilling locations for developing geothermal projects in the Tularosa Basin, New Mexico. GeothermalCloud found potential prospective locations for geothermal resources near White Sands Missile Range and McGregor Range at Fort Bliss. Magnetotellurics data determined the potential depth (~1800m) of geothermal prospects at McGregor Range based on apparent resistivity structures/layers in the subsurface. The McGregor Range consists of three resistivity layers and two resistivity structures. Magnetotellurics data also helps identify that the western portion of the McGregor Range has thick and low-resistivity earth materials. The low resistivity to the west is most likely for a fault system. Assuming temperature is consistent with a geothermal reservoir, the west-central part of the McGregor Range has the highest geothermal potential because of the increase in porosity and associated permeability attributed to the interpreted fault system. Also, we devised a coupling strategy between a process model and GeothermalCloud to characterize hydrogeological conditions and geothermal conditions, respectively. The process model characterizes hydrogeological and geothermal conditions on highly prospective geothermal sites provided by GeothermalCloud. We developed a physics-informed neural network (PINN) version of the Burns equation that can be easily coupled with GeothermalCloud. Furthermore, we performed an optimal design decision maximizing the economic value of an EGS power plant. This study optimized the range of well spacing between injection and production wells maximizing net present value in dollars (NPV). For this task, we used the GeoDT to simulate the Utah FORGE EGS development cycle from the initial well design to the end of production. Next, we accomplished another crucial task, which is predicting permeability of geothermal reservoirs. Predicting permeability of geothermal reservoirs is a non-trivial task because of huge computational runtime of simulation and lack of measurements. To avoid these limitations, we used easy-to-measure chemical concentrations in the subsurface as measurement data and convolutional neural network based ML model of a high-fidelity model. Next, we predicted permeability using Markov chain Monte Carlo simulation. We found that Markov chain Monte Carlo simulation predicts permeability with a high certainty if the prediction zone in the simulation area has chemical concentration data. Finally, we analyzed the DOE funded INGENIOUS and GeoDAWN projects data. For discovering hidden geothermal systems in the Great Basin, the INGENIOUS project accumulated old data, collected new data, and released them in 2022. The dataset includes a total of 24 geological, geophysical, and geochemical attributes. Data resolution and scale significantly vary prohibiting an appropriate usage. To avoid such limitations, we brought all data in the same resolution and scale by applying the inverse distance weighting interpolation technique for predicting data in unsampled locations. Subsequently, we analyzed LiDAR data of the GeoDAWN project. We received data in tiles format. The DOE’s overarching goal is to use ML on LiDAR data for finding favorable geological structures (e.g., step up faults in Brady, Nevada). To serve the purpose, we need to label favorable geologic structures that correspond to LiDAR data. We wrote an algorithm to label the LiDAR data with the favorable geologic structures.

15 GEOTHERMAL ENERGY↗

Evaluation of Maximum Dose Rate Resulting from Failure of the Linac Charge Monitoring System

This evaluation was prepared in response to a request from the Accelerator Readiness Review Team for NSLS-II Routine Operations. The purpose of this evaluation is to document the maximum dose rate potential for failures in the linac charge monitoring system. It is noted that the probability of such a failure is extremely low and likely never realized. For the failure to occur, the linac injection has to be set to maximum output, monitoring devices as displayed in the Control Room would go unnoticed by the Operators, the Operator on duty would have to fail to recognize the event, other accumulating charge monitors that alarm at ASE limits would also need to fail or would have to go unrecognized by the Operator and finally there would have to be a simultaneous fault in the storage ring to generate dose on the experimental floor. Regardless of these multiple layers of protection, the maximum dose rate to staff on the NSLS-II experimental floor is presented below.

36 MATERIALS SCIENCE↗

Innovations in underground hydrogen storage with multiphysics simulations, optimization, and monitoring: A review

Underground Hydrogen Storage (UHS) is a promising solution for large-scale energy storage and a critical component in advancing low-carbon energy system. Ensuring the safety and efficiency of UHS necessitates a comprehensive understanding of multiphysical interactions driven by cyclic pore fluid pressure fluctuations and coupled physicochemical processes. Here, this review examines the key geomechanical responses in UHS, including rock property variations under cyclic loading, fracture evolution and propagation, reservoir stress sensitivity, and fault stability. It also explores the impact of geochemical and microbial reactions on geomechanical characteristics. We provide an in-depth analysis of Thermal-Hydraulic-Mechanical-Chemical (THMC) coupled numerical simulations, highlighting their potential for future multi-scale modeling. Limitations of current machine learning (ML) approaches in addressing UHS challenges are highlighted, emphasizing the need for innovative ML-based methodologies. Operational strategies for hydrogen injection and production are reviewed, focusing on safety, efficiency, and economic viability. The necessity for multi-objective optimization (MOO) to balance storage efficiency, risk mitigation, and cost-effectiveness is also discussed. Current monitoring technologies are evaluated to ensure safe and efficient UHS operations. Finally, this review identifies critical knowledge gaps and underscores the importance of advancing geomechanical understanding under multiphysics-coupling. We highlight the need for ML-driven multiphysics theories, enhanced modeling techniques, and robust optimization strategies to improve UHS performance. This study serves as a comprehensive reference for future research and the large-scale implementation of UHS systems.

25 ENERGY STORAGE↗

Integrating distributed acoustic sensing, borehole 3C geophone array, and surface seismic array data to identify long-period long-duration seismic events during stimulation of a Marcellus Shale gas reservoir

Microseismic monitoring by downhole geophones, surface seismic, fiber-optic distributed acoustic sensing (DAS), and distributed temperature sensing (DTS) observations were made during the hydraulic fracture stimulation of the MIP-3H well in the Marcellus Shale in northern West Virginia. DAS and DTS data measure the fiber strain and temperature, respectively, along a fiber-optic cable cemented behind the casing of the well. The presence of long-period long-duration (LPLD) events is evaluated in the borehole geophones, DAS data, and surface seismic data of one of the MIP-3H stimulated stages. LPLD events are generally overlooked during the conventional processing of microseismic data, but they represent significant nonbrittle deformation produced during hydraulic fracture stimulation. In a single stage that was examined, 160 preexisting fractures and two faults of suboptimal orientation are noted in the image logs. We identified two low-frequency ([Formula: see text]) events of large temporal duration (tens of seconds) by comparing the surface seismic data, borehole geophone data, and DAS amplitude spectra of one of the MIP-3H stages. Spectrograms of DAS traces in time and depth reveal that the first low-frequency event might be an injection noise that has footprints on all DAS channels above the stimulated stage. However, the surface seismic array indicates an LPLD event concurrent with the first low-frequency event on DAS. The second LPLD event on DAS data and surface seismic data is related to a local deformation and does not have footprints on all DAS channels. The interpreted events have duration less than 100 s with frequencies concentrated below 10 Hz, and are accompanied by microseismic events.

Geochemistry & Geophysics↗

Pattern formation during healing of fluid-filled cracks: an analog experiment

The formation and subsequent healing of cracks and crack networks may control such diverse phenomena as the strengthening of fault zones between earthquakes, fluid migrations in the Earth's crust, or the transport of radioactive materials in nuclear waste disposal. An intriguing pattern-forming process can develop during healing of fluid-filled cracks, where pockets of fluid remain permanently trapped in the solid as the crack tip is displaced driven by surface energy. Here, we present the results of analog experiments in which a liquid was injected into a colloidal inorganic gel to obtain penny-shaped cracks that were subsequently allowed to close and heal under the driving effect of interfacial tension. Depending on the properties of the gel and the injected liquid, two modes of healing were obtained. In the first mode, the crack healed completely through a continuous process. The second mode of healing was discontinuous and was characterized by a 'zipper-like' closure of a front that moved along the crack perimeter, trapping fluid that may eventually form inclusions trapped in the solid. This instability occurred only when the velocity of the crack tip decreased to zero. Our experiments provide a cheap and simple analog to reveal how aligned arrays of fluid inclusions may be captured along preexisting fracture planes and how small amounts of fluids can be permanently trapped in solids, modifying irreversibly their material properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Report: Approaches to Some of the Outstanding Problems of Heterogeneous Compactive Deformation of Geomaterials

Evidence from laboratory experiments and field observations on porous rocks (and other porous materials) has indicated that compaction does not necessarily occur homogeneously, but, instead, is localized in narrow planar zones that are perpendicular to the maximum compressive stress. Because the permeability of these zones is reduced by several orders of magnitude, they present barriers to fluid flow across them. Consequently, their formation in reservoirs or aquifers can adversely affect attempts to inject or withdraw fluids, such as CO 2 . Because the zones are narrow, they will be difficult to detect from the surface and, as a result, it is important to understand the conditions for their formation and extension.

58 GEOSCIENCES↗

Geodetic measurements and numerical models of transient deformation at Raft River geothermal field, Idaho, USA

Here, we perform synthetic aperture radar interferometry using data acquired between 2004 and 2016 by the Envisat, and ALOS-2 satellite missions to measure transient deformation at the Raft River geothermal field in Cassia County in Southern Idaho where geothermal production began in late 2007. Time-series analysis of multiple interferometric pairs indicates uplift at an exponentially decaying rate, over an ~8 km-by-5 km area centered near three injection wells that recycle produced brine. Similarly, subsidence at an exponentially decaying rate is observed in a 4 km-by-4 km area west of the production wells. These two signatures stay in the same location in all of the well-correlated Envisat interferometric pairs spanning the time interval between 2007 and 2010. The boundary separating the uplifting and subsiding areas is associated with the steeply dipping Bridge fault zone. Using two-dimensional numerical models, we explore first-order, bi-directional coupling between hydrological and mechanical processes. Our results suggest that: (i) most of the deformation occurs due to pore pressure changes following the start of geothermal production, (ii) the rate of deformation decays to zero over a time scale on the order of ~5 years as the system reaches steady state, and (iii) a reservoir-scale permeability of the order of ~1E–14 m 2 is required to explain the transient deformation.

15 GEOTHERMAL ENERGY↗

Flexible $I_{Q}\!\!-\!\!V$ Scheme of a DFIG for Rapid Voltage Regulation of a Wind Power Plant

This paper proposes a flexible reactive current-to-voltage (I Q -V) scheme of a doubly-fed induction generator (DFIG) for the rapid voltage regulation of a wind power plant (WPP). In the proposed scheme, the WPP controller dispatches different voltage set points to the DFIGs depending on their rotor voltage margins. The DFIGs inject different reactive power with the flexible I Q -V schemes implemented in the rotor-side and grid-side converters. The I Q -V characteristic, which consists of the gain and width of a linear band and I Q capability, varies with time depending on the I Q capability of the converters and a voltage dip at the point of interconnection (POI). To increase the I Q capability during a fault, the active current is reduced in proportion to a voltage dip. If the I Q capability and/or the POI voltage dip are large, the I Q -V gain is set to be high, thereby providing rapid voltage regulation. To avoid an overvoltage after the fault clearance, a rapid I Q reduction scheme is implemented in the WPP and DFIG controllers. The performance of the proposed flexible scheme was verified under scenarios with various disturbances. In conclusion, the proposed scheme can help increase wind power penetration without jeopardizing voltage stability.

17 WIND ENERGY↗

Grid-Tied PV Inverter with Oversized Power Module to Increase its Low-Voltage Ride Through (LVRT) Capabilities and VAR Support

This paper proposes a novel design for grid-tied 3-ph Photovoltaic (PV) inverter to improve its low-voltage ride through (LVRT) response while significantly increasing its voltampere reactive (VAR) support during voltage sags. The literature available on LVRT for PV inverters can be grouped in solutions that dissipate the excess energy and those that temporary stores this energy. This paper proposes a third solution; oversizing inverter hardware components to safely transferring all the energy excess back to while maintaining the semiconductor under the maximum temperature limits. The advantages of the proposed approach are: 1) Improved LVRT capabilities and stable dc-link voltage control at MPP during sags. 2) Increased VAR support during voltage sags. 3) Increased use of renewable energy as all active power is injected back to the grid during voltage sags. Finally, the proposed solution is more cost effective compared with solutions that incorporate energy storage because only a few inverter components are required to be oversized. This paper also presents a detailed power loss analysis, which determined that that oversizing the power semiconductors has minimal impact in the inverter losses while significatively reducing the diode and IGBT conduction losses during both normal operation and grid fault conditions.

Ferrari Maglia, Max↗