Tensile properties of an ultrahigh-strength graphite fiber in an epoxy matrix

The fiber performance and reinforcement potential for fiber composites of a special PAN-based graphite fiber were evaluated by testing the fiber's tensile properties in an epoxy matrix. Representative strand samples were taken from 30 spools of single-end, 1500-filament fiber to make over 5000 fiber/epoxy strand specimens using the filament-winding process. Characteristics studied were fiber uniformity, strength and modulus distributions at room and liquid-nitrogen temperatures, stress-strain behavior, the effect of strain rate on fiber strength, and acoustic emission during tensile loading to failure. The fiber was found to have a 3570-MPa failure stress, a 1.7% failure strain, a 206-GPa modulus, and a density of 1.77 Mg/cu m at 23 C. Liquid-nitrogen temperature and various strain rates had no significant effect on fiber tensile properties.

Chiao, T. T.↗

Investigation of Mechanisms of Blade Failure of Forged Hastalloy B and Cast Stellite 21 Turbine Blades in Turbojet Engine

An investigation was conducted to study the mechanisms of blade failure of forged Hastelloy B and cast Stellite 21. The blades were mounted in a 16-25-6 alloy rotor and subjected to 20-minute cycles consisting of 15 minutes at rated speed and approximately 5 minutes at idle. The first failures of the Hastelloy B and Stellite 21 blades were probably the result of excessive vibratory stresses and occurred after 14.25 and 16.75 hours, respectively. After 28.75 hours of operation, all but 3 of the original 25 Hastelloy B blades had either failed or contained stress-rupture-type cracks and four of the original 27 Stellite 21 blades contained stress-rupture-type cracks.

ENGINES, TURBO-JET↗

Reliability Evaluation of Base-Metal-Electrode Multilayer Ceramic Capacitors for Potential Space Applications

Base-metal-electrode (BME) ceramic capacitors are being investigated for possible use in high-reliability spacelevel applications. This paper focuses on how BME capacitors construction and microstructure affects their lifetime and reliability. Examination of the construction and microstructure of commercial off-the-shelf (COTS) BME capacitors reveals great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and 0.5 m, which is much less than that of most PME capacitors. BME capacitors can be fabricated with more internal electrode layers and thinner dielectric layers than PME capacitors because they have a fine-grained microstructure and do not shrink much during ceramic sintering. This makes it possible for BME capacitors to achieve a very high capacitance volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT). Most BME capacitors were found to fail with an early avalanche breakdown, followed by a regular dielectric wearout failure during the HALT test. When most of the early failures, characterized with avalanche breakdown, were removed, BME capacitors exhibited a minimum mean time-to-failure (MTTF) of more than 105 years at room temperature and rated voltage. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically around 12 for a number of BME capacitors with a rated voltage of 25V. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life expectancy of the BME capacitor. The leakage current characterization and the failure analysis results suggest that most of these early avalanche failures are due to the extrinsic minor construction defects introduced during fabrication of BME capacitors. The concentration of the extrinsic defects must be reduced if the BME capacitors are considered for high reliability applications. There are two approaches that can reduce or prevent the occurrence of early failure in BME capacitors: (1) to reduce the defect concentration with improved processing control; (2) to prevent the use of BME capacitors under harsh external stress levels so that the extrinsic defects will never be triggered for a failure. In order to do so appropriate dielectric layer thickness must be determined for a given rated voltage.

Liu, David (Donhang)↗

NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test as of 736 kg of Propellant Throughput

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation solar-electric ion propulsion system with significant enhancements beyond the state-of-the-art NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) ion propulsion system to provide future NASA science missions with enhanced mission capabilities. A Long-Duration Test (LDT) was initiated in June 2005 to validate the thruster service life modeling and to qualify the thruster propellant throughput capability. The thruster has set electric propulsion records for the longest operating duration, highest propellant throughput, and most total impulse demonstrated. At the time of this publication, the NEXT LDT has surpassed 42,100 h of operation, processed more than 736 kg of xenon propellant, and demonstrated greater than 28.1 MN s total impulse. Thruster performance has been steady with negligible degradation. The NEXT thruster design has mitigated several lifetime limiting mechanisms encountered in the NSTAR design, including the NSTAR first failure mode, thereby drastically improving thruster capabilities. Component erosion rates and the progression of the predicted life-limiting erosion mechanism for the thruster compare favorably to pretest predictions based upon semi-empirical ion thruster models used in the thruster service life assessment. Service life model validation has been accomplished by the NEXT LDT. Assuming full-power operation until test article failure, the models and extrapolated erosion data predict penetration of the accelerator grid grooves after more than 45,000 hours of operation while processing over 800 kg of xenon propellant. Thruster failure due to degradation of the accelerator grid structural integrity is expected after

Shastry, Rohit↗

NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test as of 736 kg of Propellant Throughput

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation solar-electric ion propulsion system with significant enhancements beyond the state-of-the-art NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) ion propulsion system to provide future NASA science missions with enhanced mission capabilities. A Long-Duration Test (LDT) was initiated in June 2005 to validate the thruster service life modeling and to qualify the thruster propellant throughput capability. The thruster has set electric propulsion records for the longest operating duration, highest propellant throughput, and most total impulse demonstrated. At the time of this publication, the NEXT LDT has surpassed 42,100 h of operation, processed more than 736 kg of xenon propellant, and demonstrated greater than 28.1 MN s total impulse. Thruster performance has been steady with negligible degradation. The NEXT thruster design has mitigated several lifetime limiting mechanisms encountered in the NSTAR design, including the NSTAR first failure mode, thereby drastically improving thruster capabilities. Component erosion rates and the progression of the predicted life-limiting erosion mechanism for the thruster compare favorably to pretest predictions based upon semi-empirical ion thruster models used in the thruster service life assessment. Service life model validation has been accomplished by the NEXT LDT. Assuming full-power operation until test article failure, the models and extrapolated erosion data predict penetration of the accelerator grid grooves after more than 45,000 hours of operation while processing over 800 kg of xenon propellant. Thruster failure due to degradation of the accelerator grid structural integrity is expected after groove penetration.

Shastry, Rohit↗

Viscoelastic deformation near active plate boundaries

Model deformations near the active plate boundaries of Western North America using space-based geodetic measurements as constraints are discussed. The first six months of this project were spent gaining familarity with space-based measurements, accessing the Crustal Dynamics Data Information Computer, and building time independent deformation models. The initial goal was to see how well the simplest elastic models can reproduce very long base interferometry (VLBI) baseline data. From the Crustal Dynamics Data Information Service, a total of 18 VLBI baselines are available which have been surveyed on four or more occasions. These data were fed into weighted and unweighted inversions to obtain baseline closure rates. Four of the better quality lines are illustrated. The deformation model assumes that the observed baseline rates result from a combination of rigid plate tectonic motions plus a component resulting from elastic strain build up due to a failure of the plate boundary to slip at the full plate tectonic rate. The elastic deformation resulting from the locked plate boundary is meant to portray interseismic strain accumulation. During and shortly after a large interplate earthquake, these strains are largely released, and points near the fault which were previously retarded suddenly catch up to the positions predicted by rigid plate models. Researchers judge the quality of fit by the sum squares of weighted residuals, termed total variance. The observed baseline closures have a total variance of 99 (cm/y)squared. When the RM2 velocities are assumed to model the data, the total variance increases to 154 (cm/y)squared.

Ward, S. N.↗

Analysis of interlaminar fracture in composites under combined loading

Delamination is a predominant failure mode in continuous fiber reinforced laminated composite structures. One type of delamination is the transverse crack tip delamination which originates at the tip of transverse matrix cracks. An analytical model based on the sublaminate approach and fracture mechanics is developed to study the growth of such delaminations. Plane strain conditions are assumed and estimates are provided for the total strain energy release rate as well as the mode 1 and mode 2 contribution. The energy release rate estimates are used in combination with a simple failure law to predict critical delamination growth strains and stresses. These predictions are compared with experimental data on T300/934 Graphite Epoxy (+ or - 25/90 nano seconds) laminates in the range n=.5 to 8. A good agreement is demonstrated for the range of n where the experimental observations indicate transverse crack tip delamination to be the predominant failure mode.

Armanios, Erian A.↗

Verification and Validation of Progressive Damage and Failure Analysis Methods for Intralaminar Failure Modes in Thermoplastic Composites

Current progressive damage and failure analysis (PDFA) methods were developed around thermoset material systems and their physical behavior. However, the applicability of these analysis methods has not been evaluated for use in modeling thermoplastic material systems. As part of the Hi-Rate Composite Aircraft Manufacturing (HiCAM) Project sponsored by NASA, intralaminar failure characterization was completed on a thermoplastic material system, AS4D/PEKK-FC, with off-axis tension (OAT) and off-axis compression (OAC) testing. The experiments were able to capture matrix non-linear shear behavior and the failure envelope of the material system. Two PDFA methods, LS-DYNA MAT299 and NASA’s CompDam-DGD, were then employed to simulate individual coupon behavior and simulation results were compared to published verification and validation guidelines from the CMH-17 crashworthiness working group. The results found that the two modeling methods provided suitable representation of material behavior of thermoplastics.

PDFA↗

Verification and Validation of Progressive Damage and Failure Analysis Methods for Intralaminar Failure Modes in Thermoplastic Composites

Current progressive damage and failure analysis (PDFA) methods were developed around thermoset material systems and their physical behavior. However, the applicability of these analysis methods has not been evaluated for use in modeling thermoplastic material systems. As part of the Hi-Rate Composite Aircraft Manufacturing (HiCAM) Project sponsored by NASA, intralaminar failure characterization was completed on a thermoplastic material system, AS4D/PEKK-FC, with off-axis tension (OAT) and off-axis compression (OAC) testing. The experiments were able to capture matrix non-linear shear behavior and the failure envelope of the material system. Two PDFA methods, LS-DYNA MAT299 and NASA’s CompDam-DGD, were then employed to simulate individual coupon behavior and simulation results were compared to published verification and validation guidelines from the CMH-17 crashworthiness working group. The results found that the two modeling methods provided suitable representation of material behavior of thermoplastics.

PDFA↗

Effect of Load Rate on Ultimate Tensile Strength of Ceramic Matrix Composites at Elevated Temperatures

The strengths of three continuous fiber-reinforced ceramic composites, including SiC/CAS-II, SiC/MAS-5 and SiC/SiC, were determined as a function of test rate in air at 1100 to 1200 C. All three composite materials exhibited a strong dependency of strength on test rate, similar to the behavior observed in many advanced monolithic ceramics at elevated temperatures. The application of the preloading technique as well as the prediction of life from one loading configuration (constant stress-rate) to another (constant stress loading) suggested that the overall macroscopic failure mechanism of the composites would be the one governed by a power-law type of damage evolution/accumulation, analogous to slow crack growth commonly observed in advanced monolithic ceramics. It was further found that constant stress-rate testing could be used as an alternative to life prediction test methodology even for composite materials, at least for short range of lifetimes and when ultimate strength is used as the failure criterion.

Choi, Sung R.↗

Nonstationary envelope process and first excursion probability

A definition of the envelope of nonstationary random processes is proposed. The establishment of the envelope definition makes it possible to simulate the nonstationary random envelope directly. Envelope statistics, such as the density function, joint density function, moment function, and level crossing rate, which are relevent to analyses of catastrophic failure, fatigue, and crack propagation in structures, are derived. Applications of the envelope statistics to the prediction of structural reliability under random loadings are discussed in detail.

Yang, J.↗

Prior-to-failure extension of flaws under monotonic and pulsating loadings.

An equation governing the prior-to-failure crack propagation is proposed. For a rate-sensitive solid containing a two-dimensional crack and subject to the tensile mode of fracture the differential equations are integrated numerically for loads increasing monotonically in time. The resulting integral curves of load vs crack length and length vs time indicate that the growth of cracks in the subcritical range is strongly rate-dependent. The fatigue growth, viewed as a sequence of slow growth periods, is simulated on an EAI 380 analog computer. The fourth-power law proposed by Paris is confirmed only within certain range of high-cycle fatigue propagation and for a rate-insensitive solid. Otherwise, i.e., for a more pronounced rate dependence induced by viscosity of a solid and/or in the proximity of the final instability point, the growth is markedly enhanced.

Wnuk, M. P.↗

Prior-to-failure extension of flaws under monotonic and pulsating loadings: Inelastic fatigue

An equation governing the prior to failure crack propagation is proposed. For a rate-sensitive solid containing two-dimensional crack and subject to the tensile mode of fracture, the differential equations are integrated numerically for the loads increasing monotonically in time. The resulting integral curves sigma = sigma(l) and l = l(t), i.e. load vs. crack length and length vs. time, indicate that the growth of cracks in the subcritical range is strongly rate dependent. The fatigue growth, viewed as a sequence of slow growth periods, is simulated on an EAI 380 analogue computer. The fourth power law proposed by Paris is confirmed only within a certain range of high-cycle fatigue propagation and for a rate-insensitive solid. For a more pronounced rate dependency, induced by the viscosity of a solid and/or in the proximity of the final instability point, the growth is markedly enhanced.

Wnuk, M. P.↗

Creep rupture of polymer-matrix composites

The time-dependent creep-rupture process in graphite-epoxy laminates is examined as a function of temperature and stress level. Moisture effects are not considered. An accelerated characterization method of composite-laminate viscoelastic modulus and strength properties is reviewed. It is shown that lamina-modulus master curves can be obtained using a minimum of normally performed quality-control-type testing. Lamina-strength master curves, obtained by assuming a constant-strain-failure criterion, are presented along with experimental data, and reasonably good agreement is shown to exist between the two. Various phenomenological delayed failure models are reviewed and two (the modified rate equation and the Larson-Miller parameter method) are compared to creep-rupture data with poor results.

Brinson, H. F.↗

Determination of interlaminar fracture toughness and fracture mode dependence of composites using the edge delamination test

Edge delamination testing has been conducted in order to determine the mixed mode interlaminar fracture toughness of unnotched (+, -35/0/90)s and (0/+, -35/90)s laminates with graphite fibers and epoxy matrices, with or without elastomer additives. Although the two stacking sequences were chosen so that the total strain energy release rates were equal, the percentages of crack opening and shear mode energy release rates were found to vary widely between the layups. Plots of interlaminar fracture toughness as a function of crack opening energy release rate percentage have been drawn to generate delamination failure criteria which reflect the observed fracture mode dependence.

Obrien, T. K.↗

Space reliability technology - A historical perspective

The progressive improvements in reliability of launch vehicles is traced from the Vanguard rocket to the STS. The Vanguard, built with minimal redundancy and a high mass ratio, was used as an operational vehicle midway through its test program in an attempt to meet the perceived challenge represented by the Sputnik. The fourth Vanguard failed due to inadequate contamination prevention and lack of inspection ports. Automatic firing sequences were adopted for the Titan rockets, which were an order of magnitude larger than the Vanguard and therefore had room for interior inspections. Qualification testing and reporting were introduced for components, along with X ray inspection of fuel tank welds. Dual systems were added for flight critical components when the Titan became man-rated for the Gemini program. Designs incorporated full failure mode effects and criticality analyses for the Apollo program, which exposed the limits of applicability of numerical reliability models. Fault tree analyses and program milestone reviews were initiated. The worth of man-in-the-loop in space activities for reliability was demonstrated with the rescue of Skylab after solar panel and meteoroid shield failures. It is now the reliability of the payload, rather than the vehicle, that is questioned for Shuttle launches.

Cohen, H.↗

Total dose effects in the 54HC family of microcircuits

Motorola and National Semiconductor 54HC00 and 54HC74 microcircuits were evaluated using CO-60 to determine their total dose radiation hardness. The devices were found to be radiation soft failing parametrically between 5 and 10 K rads and functionally between 20 and 40 K rads. The failures were bias dependent, relatively insensitive to dose rate, and only annealed moderately when left unbiased at room temperature.

Ropiak, S.↗

Correlation of Chemical and Physical Test Data For the Environment Ageing of Coflon (PVDF)

This report aims to identify correlations between mechanical property changes and chemical/morphological structure changes for Coflon. It is intended both to illustrate the overall methodology and to indicate the testing that needs to be undertaken in order to obtain correlations. Many fluid exposures have now been carried out on Coflon during the project and many data generated as a result. The report summarises the changes observed in mechanical and physical properties and relates these as well as possible to the chemistry thought to be occurring during ageing. For this purpose, data have been collated from already-issued MERL and TRI technical and progress reports. Most of the mechanical testing of aged testpieces has been performed soon after the completion of the exposure; however, there is of necessity a delay in obtaining chemical analysis of the same testpieces, so that more physical than chemical data are shown. Three fluids have so far caused measurable deterioration of Coflon, these being: methanol (Fluid A), a methanol and amine mixture (Fluid G), and a mixture of methane, carbon dioxide gas and hydrogen sulphide gas plus aqueous amine (Fluid F). Only the effects of these fluids will be dealt with in any detail in this report, although other fluids are assessed to give relevant background information. Relevant test data collated here include: tensile modulus and related properties, mode of sample failure at break, fracture toughness, fatigue crack growth rate and resistance, stress relaxation rate, permeation coefficients, % crystallinity and molecular weight distributions together with changes in fluorine levels, and other observations where appropriate. However, not all of these were obtained for every ageing condition. Because of the wide range of tests employed, and the different ways in which their results are obtained, the following section has been included to serve as a background for making comparisons.