It's About The Neutrons
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Many countries have decarbonization plans that include transitioning to clean energy. Because of this, PV deployment is projected to at least double or triple in the next ten years. As we ramp up manufacturing and deployment, we aim to sustainably establish secure and just supply chains while reducing environmental impacts. This talk presents our analysis of the virgin material demands, addresses waste concerns regarding quantity and toxicity, and establishes sustainability actions that the PV community can take to ensure sustainability. The takeaway actions are prioritizing reliable, high-quality, and long-lived PV modules and enabling the fast deployment needed for decarbonization via more research and effective communication.
Behind-the-Meter Storage (BTMS) is a battery-based, stationary energy storage system that is connected to the residential or industrial customer's side of the electrical grid utility service meter. BTMS systems enable consumers to (A) economically schedule charging and usage of stored energy, (B) store and use energy from on-site generation, especially from inconstant, renewable sources like solar and wind, and (C) avoid overloading the grid during peak hours via supplementation with stored energy. BTMS battery performance requirements and general priorities differentiate from other applications, like EVs, which has prompted the development of batteries with tailored electrode and electrolyte materials. These materials prioritize low cost, avoiding critical materials; longevity, achieving 8000 cycle and 20-year shelf lives; and importantly, high safety. Nonflammable electrolytes show promise to improve safety by mitigating thermal runaway, yet often come with sacrifices to battery performance. In this presentation (1) primary categories of nonflammable electrolytes will be discussed; (2) a rational design of experiment will be presented for efficient performance evaluation of several nonflammables electrolyte in BTMS-relevant battery chemistry, Li4Ti5O12- and LiNi0.90Mn0.10O2; and (3) preliminary results will be presented.
Overview of the SIPs on PV Repowering Project funded by SETO titled "Quantifying the Impact of PV System Repowering and Module Reuse on PV Project Economics, Sustainability, & Equity".
Computational methods underpin advancing the science and engineering of energy technologies and developing a knowledge base to optimize energy systems. NLR's Computational Science Center (CSC) proudly focuses on providing the service of computing, advancing the science of computing, and enabling DOE missions.
Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.
This investigation summarizes a comparative study of two high-speed engine performance assessment techniques based on energy (available work) and thrust-potential (thrust availability). Simple flow-fields utilizing Rayleigh heat addition and one-dimensional flow with friction are used to demonstrate the fundamental inability of conventional energy techniques to predict engine component performance, aid in component design, or accurately assess flow losses. The use of the thrust-based method on these same examples demonstrates its ability to yield useful information in all these categories. Energy and thrust are related and discussed from the stand-point of their fundamental thermodynamic and fluid dynamic definitions in order to explain the differences in information obtained using the two methods. The conventional definition of energy is shown to include work which is inherently unavailable to an aerospace Brayton engine. An engine-based energy is then developed which accurately accounts for this inherently unavailable work; performance parameters based on this quantity are then shown to yield design and loss information equivalent to the thrust-based method.
The increasing electrification of aircraft propulsion systems is leading to new control architectures being developed to address integration between electric machines and gas-based turbine engines. For hybrid-electric propulsion systems, current conceptual architectures often couple electric machines with the shafts of gas turbine engines and introduce energy storage. Leveraging the electrical power system of hybridized engines, Turbine Electrified Energy Management (TEEM) is a recent control approach that improves transient operability in an effort to enable more efficient and lighter weight turbomachinery. This study seeks to expand TEEM’s application beyond traditional proportional integral (PI) control by presenting linear model predictive control (MPC) schemes to execute the TEEM concept. Through constraint selection and cost function design, transient operability goals for TEEM are considered with no external logic or saturation. Unique to the designs are the use of a washout filter, which simplifies transient detection and motor activation logic. The proposed architectures are implemented with both centralized MPC and distributed MPC approaches, and comparisons are drawn to a benchmark PI controller simulated on a nonlinear turbofan engine model at one ground condition and one cruise condition. Performance is evaluated using compressor maps, stall margin performance, and two novel metrics: transient stack usage and transient excursion integral. Results reveal the linear MPC scheme performs comparably to the baseline controller and can be implemented in at least two distinct configurations with potential for further modifications, thus establishing the groundwork for future investigations.
The increasing electrification of aircraft propulsion systems is leading to new control architectures being developed to address integration between electric machines and gas-based turbine engines. For hybrid-electric propulsion systems, current conceptual architectures often couple electric machines with the shafts of gas turbine engines and introduce energy storage. Leveraging the electrical power system of hybridized engines, Turbine Electrified Energy Management (TEEM) is a recent control approach that improves transient operability in an effort to enable more efficient and lighter weight turbomachinery. This study seeks to expand TEEM’s application beyond traditional proportional-integral (PI) control by presenting linear model predictive control (MPC) schemes to execute the TEEM concept. Through constraint selection and cost function design, transient operability goals for TEEM are considered with no external logic or saturation. Unique to the designs are the use of a washout filter, which simplifies transient detection and motor activation logic. The proposed architectures are implemented with both centralized MPC and distributed MPC approaches, and comparisons are drawn to a benchmark PI controller simulated on a nonlinear turbofan engine model at one ground condition and one cruise condition. Performance is evaluated using compressor maps, stall margin performance, and two novel metrics: transient stack usage and transient excursion integral. Results reveal the linear MPC scheme performs comparably to the baseline controller and can be implemented in at least two distinct configurations with potential for further modifications, thus establishing the groundwork for future investigations.
The increasing electrification of aircraft propulsion systems is leading to new control architectures being developed to address integration between electric machines and gas-based turbine engines. For hybrid-electric propulsion systems, current conceptual architectures often couple electric machines with the shafts of gas turbine engines and introduce energy storage. Leveraging the electrical power system of hybridized engines, Turbine Electrified Energy Management (TEEM) is a recent control approach that improves transient operability in an effort to enable more efficient and lighter weight turbomachinery. This study seeks to expand TEEM’s application beyond traditional proportional-integral (PI) control by presenting linear model predictive control (MPC) schemes to execute the TEEM concept. Through constraint selection and cost function design, transient operability goals for TEEM are considered with no external logic or saturation. Unique to the designs are the use of a washout filter, which simplifies transient detection and motor activation logic. The proposed architectures are implemented with both centralized MPC and distributed MPC approaches, and comparisons are drawn to a benchmark PI controller simulated on a nonlinear turbofan engine model at one ground condition and one cruise condition. Performance is evaluated using compressor maps, stall margin performance, and two novel metrics: transient stack usage and transient excursion integral. Results reveal the linear MPC scheme performs comparably to the baseline controller and can be implemented in at least two distinct configurations with potential for further modifications, thus establishing the groundwork for future investigations.
Explore the source record for details and available documents.
A thermal/fluids analysis of a direct gain solar thermal upper stage engine is presented and the results are discussed. The engine was designed and constructed at the NASA Marshall Space Flight Center for ground testing in a facility that can provide about 10 kilowatts of concentrated solar energy to the engine. The engine transfers energy to a coolant (hydrogen) that is heated and accelerated through a nozzle to produce thrust. For the nominal design values and a hydrogen flowrate of 2 lb./hr., the results of the analysis show that the hydrogen temperature in the chamber (nozzle entrance) reaches about 3800 F after 30 minutes of heating and about 3850 F at steady-state (slightly below the desired design temperature of about 4100 F. Sensitivity analyses showed these results to be relatively insensitive to the values used for the absorber surface infrared emissivity and the convection coefficient within the cooling ducts but very sensitive to the hydrogen flowrate. Decreasing the hydrogen flowrate to 1 lb./hr. increases the hydrogen steady-state chamber temperature to about 4700 F, but also of course causes a decrease in thrust.
Nuclear energy systems present unique challenges in terms of ensuring safety, reliability, and efficiency during their design and operation. Early fault detection is critical for mitigating risks and fostering system resilience. However, current methods often fall short at identifying faults during early stages, potentially leading to costly delays and safety risks. The present work proposes a comprehensive digital engineering approach that leverages digital twins, digital threads, model-based systems engineering, artificial intelligence, and immersive extended reality to support early fault detection in nuclear systems. Through a series of case studies, we highlight specific gaps in the fault detection mechanisms of traditional nuclear design and operation processes, then demonstrate a suite of solutions we are working to implement to address these shortcomings in similar projects. Our findings suggest that a digital engineering approach to design and operation can significantly improve fault detection, ultimately leading to reductions in risk.
Advanced electrified aircraft propulsion (EAP) concepts with integrated power, propulsion, and thermal systems require the development of equally sophisticated controllers to fly safe and efficient missions. Hybrid electric aircraft utilize electric machines mechanically coupled to the engine shafts to extract and insert power for a variety of purposes. Additionally, electric machines may drive propulsive fans pulling from a combination of on-board energy storage devices and engine extracted power. NASA’s investment in hybrid electric aircraft hardware-in-the-loop testing enables controls research on representative engine models using a novel emulation and scaling methodology. High-voltage, high-power electrical powertrain presents several technical risks at altitude. High-power requires high efficiency to minimize losses. Superconducting electric machines and power distribution research at NASA has identified key challenges with potential controls solutions. These risks necessitate the development of controllers robust to model uncertainty, disturbances, and fault conditions. System health management and fault detection schemes play an important role in a multi-layer controls approach that utilizes a supervisor which oversees inner loops for the highly coupled power, propulsion, and thermal systems. Such a supervisory controller enables coordinates energy transfer between engines, energy storage devices, electric machines, propulsors, and heat exchangers. Existing methods have shown an improvement in engine operability using the hybrid electric powertrain.
Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.
Following a nationwide open competition, the University Coalition for Fossil Energy Research (UCFER) was established in October 2015 through a cooperative agreement between Penn State and the Department of Energy (DOE) National Energy Technology Laboratory (NETL). Penn State lead UCFER with the objective of advancing basic and applied research for clean and low-carbon energy based on fossil fuels in support of the DOE’s mission. UCFER focused on research that improves the efficiency of production and use of fossil energy resources, while minimizing the environmental impacts and reducing greenhouse gas emissions. Penn State lead a team of nine universities (Massachusetts Institute of Technology, The Pennsylvania State University, Princeton University, Texas A&M University, University of Kentucky, University of Southern California, The University of Tulsa, University of Wyoming, and Virginia Polytechnic and State University) during the competition stage, adding seven more universities in 2017 (Carnegie Mellon University, Louisiana State University, The Ohio State University, University of North Dakota, University of Pittsburgh, University of Utah, and West Virginia University). This Coalition exhibited a wide geographical distribution across the U.S. bringing a wide variety of fossil energy expertise. This national university alliance was a major collaborative effort with NETL to address specific topics of R&D in NETL’s mission area, which involved one or more of NETL’s five core competencies (Geologic and Environmental Systems, Materials Engineering and Manufacturing, Energy Conversion Engineering, Systems Engineering and Analysis, and Computational Science and Engineering). The first five to six months of the project was the definitization stage. During this period, Penn State worked closely with NETL to finalize the Coalition organizational structure and By- Laws, prepare a statement of substantial involvement and a statement of project objectives, and develop operations and membership plans. A major component of this stage included preparing an execution plan to solicit research, evaluate proposals, recommend selected projects to NETL, and award projects. In addition, a plan was prepared to monitor projects, review projects, disseminate knowledge from research projects and develop an online system for Coalition research portfolio management. This included developing a website and several databases. The first of six rounds of solicitations started in mid-2016. Projects from the sixth solicitation started February 1, 2021, and ended January 31, 2023. Projects that were selected represented twelve technology lines. Approximately $16.6 million in funding was available for the six solicitations. Most of the funding was provided by DOE, Office of Fossil Energy (DOEFE) with the DOE Fuel Cells Technologies Office (DOE-FCTO) providing funding for a few projects. Coalition universities submitted 259 proposals in response to the solicitations, requesting approximately $67.0 million in funding, and forty-three projects were selected. However, one project withdrew after the principal investigator left the university. The management of the Coalition projects was a major activity by Penn State. Managing the Coalition projects consisted of monitoring the projects, reviewing the projects through annual technical review meetings, disseminating knowledge from the research projects, and developing an online system for Coalition research portfolio management. Penn State’s OMT monitored projects to ensure that all milestones (technical, schedule, budget) were met, expenditures were allowable, cost share (when applicable) were reported, and all technical reports were submitted. The OMT also posted the technical reports electronically on a secure members-only website for access and review by the Coalition members. Disseminating knowledge from the research projects was done through a website, newsletters, various meetings, conferences, journal articles, publicity/press releases, and project summaries that were prepared after each project was completed. Penn State kept NETL apprised of UCFER progress through quarterly reports (thirtyone were submitted by Penn State), verbal and written communications, yearly updates at the annual technical review meetings, and cost accrual reports. The UCFER project had a significant impacty. The UCFER program established the first national university alliance in fossil energy research with a major collaboration effort with DOE NETL that addressed specific topics in NETL’s research and development mission areas. It generated inter-university collaborations, which was another program interest. Twenty-two out of 259 proposals contained collaborations (≈8.5%) and three of forty-two funded projects involved inter-university collaborations (≈7.0%). The forty-two funded projects provided support at fourteen universities involving 269 personnel. Research was conducted by 106 faculty, 115 graduate and undergraduate students, forty-six research staff and post-doctoral scholars, and two visiting scholars. Students and post-doctoral scholars were also on-site at NETL through CRADAs. In addition, non-Coalition participants included six universities and sixteen companies and national laboratories. The non-Coalition participants were involved as subcontractors, providers of cost share, performed unpaid consultation and sample analysis, served as advisory board members, or were providers of samples and materials for testing. UCFER also produced visibility in that fifty-six refereed journal articles were published, fifty-seven conference papers and twenty-three posters were prepared, 190 presentations were given, eight patent applications were filed, two books/book chapters were written, and ten software codes were developed. Collaboration between NETL and the individual projects was a major requirement for all funded projects. This included NETL staff time to support collaboration, consultation, technical guidance, sample preparation and analysis, internships at NETL, on-site testing and equipment usage by Coalition participants at NETL, co-mentoring students, and coauthoring journal articles and conference papers. Collaboration was impacted by COVID-19 in that not all on-site activities could be performed. NETL personnel were coauthors on eight of the conference papers (fourteen percent of the conference papers that were prepared) and seventeen of the journal articles (thirty percent of the journal articles that were prepared). A website was developed for an online proposal solicitation and review process and to provide exposure to UCFER. A website analysis highlighted the large amount of member and general public interest in UCFER by interpreting access statistics from March 2016 through June 2023. Visitors to the site originated from many different organizations, businesses, and countries. The website provided a means to disseminate information to both the general public and the UCFER members and was successfully used for outreach activities. In addition, NETL required that RFP release, proposal submission, and proposal reviews all be performed online. Penn State successfully developed these capabilities in a secure section of the website, which were used throughout the UCFER project. It is recognized that each project had its technical successes. In addition, highlighted successes were compiled and summarized from the research projects. Information was requested from the PIs of completed projects. In addition, Penn State’s Operations Management Team reviewed subcontract reports to identify project successes. Examples of information requested from PIs included (not all-inclusive): new projects that have been funded as a result of UCFER funding; new commercial products; establishment of a new center; new patent; new software; best paper awards; highly-cited work; and graduate student successes. A total of forty-eight highlighted successes were reported.
Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.
Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.