Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electric Generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Advanced High Temperature Reactor Systems and Economic Analysis

The Advanced High Temperature Reactor (AHTR) is a design concept for a large-output [3400 MW(t)] fluoride-salt-cooled high-temperature reactor (FHR). FHRs, by definition, feature low-pressure liquid fluoride salt cooling, coated-particle fuel, a high-temperature power cycle, and fully passive decay heat rejection. The AHTR's large thermal output enables direct comparison of its performance and requirements with other high output reactor concepts. As high-temperature plants, FHRs can support either high-efficiency electricity generation or industrial process heat production. The AHTR analysis presented in this report is limited to the electricity generation mission. FHRs, in principle, have the potential to be low-cost electricity producers while maintaining full passive safety. However, no FHR has been built, and no FHR design has reached the stage of maturity where realistic economic analysis can be performed. The system design effort described in this report represents early steps along the design path toward being able to predict the cost and performance characteristics of the AHTR as well as toward being able to identify the technology developments necessary to build an FHR power plant. While FHRs represent a distinct reactor class, they inherit desirable attributes from other thermal power plants whose characteristics can be studied to provide general guidance on plant configuration, anticipated performance, and costs. Molten salt reactors provide experience on the materials, procedures, and components necessary to use liquid fluoride salts. Liquid metal reactors provide design experience on using low-pressure liquid coolants, passive decay heat removal, and hot refueling. High temperature gas-cooled reactors provide experience with coated particle fuel and graphite components. Light water reactors (LWRs) show the potentials of transparent, high-heat capacity coolants with low chemical reactivity. Modern coal-fired power plants provide design experience with advanced supercritical-water power cycles. The current design activities build upon a series of small-scale efforts over the past decade to evaluate and describe the features and technology variants of FHRs. Key prior concept evaluation reports include the SmAHTR preconceptual design report,1 the PB-AHTR preconceptual design, and the series of early phase AHTR evaluations performed from 2004 to 2006. This report provides a power plant-focused description of the current state of the AHTR. The report includes descriptions and sizes of the major heat transport and power generation components. Component configuration and sizing are based upon early phase AHTR plant thermal hydraulic models. The report also provides a top-down AHTR comparative economic analysis. A commercially available advanced supercritical water-based power cycle was selected as the baseline AHTR power generation cycle both due to its superior performance and to enable more realistic economic analysis. The AHTR system design, however, has several remaining gaps, and the plant cost estimates consequently have substantial remaining uncertainty. For example, the enriched lithium required for the primary coolant cannot currently be produced on the required scale at reasonable cost, and the necessary core structural ceramics do not currently exist in a nuclear power qualified form. The report begins with an overview of the current, early phase, design of the AHTR plant. Only a limited amount of information is included about the core and vessel as the core design and refueling options are the subject of a companion report. The general layout of an AHTR system and site showing the relationship of the major facilities is then provided. Next is a comparative evaluation of the AHTR anticipated performance and costs. Finally, the major system design efforts necessary to bring the AHTR design to a pre-conceptual level are then presented.

Holcomb, David Eugene↗

The Health and Climate Benefits of Economic Dispatch in China’s Power System

China’s power system is highly regulated and uses an “equal-share” dispatch approach. However, market mechanisms are being introduced to reduce generation costs and improve system reliability. Here, we quantify the climate and human health impacts brought about by this transition, modeling China’s power system operations under economic dispatch. We find that significant reductions in mortality related to air pollution (11%) and CO 2 emissions (3%) from the power sector can be attained by economic dispatch, relative to the equal-share approach, through more efficient coal-powered generation. Additional health and climate benefits can be achieved by incorporating emission externalities in electricity generation costs. However, the benefits of the transition to economic dispatch will be unevenly distributed across China and may lead to increased health damage in some regions. Our results show the potential of dispatch decision-making in electricity generation to mitigate the negative impacts of power plant emissions with existing facilities in China.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life Cycle GHG Emissions from Conventional Natural Gas Power Generation: Systematic Review and Harmonization (Presentation)

This research provides a systematic review and harmonization of the life cycle assessment (LCA) literature of electricity generated from conventionally produced natural gas. We focus on estimates of greenhouse gases (GHGs) emitted in the life cycle of electricity generation from conventionally produced natural gas in combustion turbines (NGCT) and combined-cycle (NGCC) systems. A process we term "harmonization" was employed to align several common system performance parameters and assumptions to better allow for cross-study comparisons, with the goal of clarifying central tendency and reducing variability in estimates of life cycle GHG emissions. This presentation summarizes preliminary results.

03 NATURAL GAS↗

Performance comparison between photovoltaic and thermoradiative devices

Photovoltaic (PV) and thermoradiative (TR) devices are power generators that use the radiative energy transfer between a hot and a cold reservoir. For PV devices, the semiconductor at the cold side (PV cell) generates electric power; for TR devices, the semiconductor at the hot side (TR cell) generates electric power. In this work, we compare the performance of the photovoltaic and thermoradiative devices, with and without the non-radiative processes. Without non-radiative processes, PV devices generally produce larger output powers than TR devices. However, when non-radiative processes become important, the TR can outperform the PV devices. This conclusion applies to both far-field and near-field based devices. A key difference in efficiency between PV and TR devices is pointed out.

42 ENGINEERING↗

Iquitos Solar Energy Integration Study

The National Renewable Energy Laboratory performed an evaluation of the technical and economic feasibility of incorporating solar photovoltaic (PV) resources into the Iquitos, Peru power system at the request of Peru's Ministerio de Energia y Minas (MINEM). The Iquitos power system is electrically islanded due to its remote location; heavy fuel oil is used to generate electricity in the system leading to high electricity generation costs from high fuel prices. Solar PV has the potential to provide locally derived energy to ensure a reliable, affordable, and equitable power grid for the Iquitos region.

14 SOLAR ENERGY↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗

Full complex amplitude control of second-harmonic generation via electrically tunable intersubband polaritonic metasurfaces

Nonlinear intersubband polaritonic metasurfaces based on coupling of the intersubband nonlinear optical response of quantum-engineered semiconductor heterostructures and electromagnetic modes of nanoresonators provide efficient frequency mixing with moderate pump intensities. The resonant nonlinear optical response, represented as a complex function, can be modulated via Stark tuning of intersubband transition energies under applied voltages. However, achieving full complex amplitude control (both phase and magnitude) remains challenging. In this work, we present and experimentally validate electrically tunable nonlinear intersubband polaritonic metasurfaces that achieve complete complex amplitude control for second-harmonic generation (SHG). Through a design featuring two in-plane flipped meta-atoms per unit cell, we achieve complete electrical control of both the amplitude and phase of the metasurface second-order nonlinear susceptibility, with a tuning range of 0 to 30 nm V −1 for the magnitude and 0-2π for the phase of the nonlinear optical response. Using these properties, we achieve complete on-off SHG modulation and beam diffraction tuning through electrically controlled amplitude and phase gratings.

Science & Technology - Other Topics↗

Monitoring and modeling hydrologic conditions in Ukraine for hydropower generation

Study region: The Dnieper and Dniester Rivers of Ukraine. Study focus: The ongoing conflict in Ukraine has caused disruptions to electricity generation, of which hydroelectric sources contribute approximately 9 % to the country’s needs. With the takeover of the Zaporizhzhia nuclear power plant by enemy forces, the loss of the Kakhovka hydroelectric dam, and the future impacts of the conflict on electricity generation unclear, it may be valuable for the Ukrainian government to better understand how it could leverage hydroelectric power sources in the near future. Unfortunately, measurements of river discharge throughout Ukraine ceased data collection in the late 1980’s to early 1990’s. To address this data gap, we developed a protocol that combined satellite-based time-series measurements of river width at seven locations throughout Ukraine from 2013 to 2023 with reanalysis data, climate-model predictions, and hydrologic models to both provide a means of monitoring a proxy for near-real-time discharge and also predict near-term (i.e., 2023–2030) hydrologic patterns for the region. New hydrological insights for the region: We ran new algorithms on 144 WorldView-2 and WorldView-3 satellite images to map rivers and extract width, one of which was validated against river gauge data located along the same river but in a neighboring country. Hydrologic models using two climate scenarios found minimal change in annual discharge at all sites, but magnitude and timing of peak discharge showed a moderate trend. The results suggest that hydropower is underutilized in Ukraine.

13 HYDRO ENERGY↗

Feb. 2021 Electricity Blackouts and Natural Gas Shortages in Texas

An extreme winter storm and extended cold weather event hit Texas and the central United States February 8–19, 2021. This led to both exceptional energy demands and issues with electricity and natural gas supplies over several days. Residential space heating drove the increases in demand, with over 60% of Texas homes using electric heat pumps and 35% using natural gas furnaces. Supply issues were caused by freezing equipment and supply lines, impacting both natural gas supplies and most forms of electricity generation. [1] Natural gas supplies were especially important because natural gas also supplied about 50% of the electricity generating capacity in ERCOT, the primary grid operator in Texas. [2] Due to the supply shortages, wholesale electricity prices were forced to the ERCOT maximum of $\$9,000$ /MWh for over three days (recent range $\$20$–40/MWh), [3] and natural gas prices for physical delivery exceeded $\$400$ /MMBtu in some areas (recent range $\$3$–4/MMBtu). [4]

03 NATURAL GAS↗

Light Water Reactor Sustainability Research and Development Program Plan -- Fiscal Year 2009–2013

Nuclear power has reliably and economically contributed almost 20% of electrical generation in the United States over the past two decades. It remains the single largest contributor (more than 70%) of non-greenhouse-gas-emitting electric power generation in the United States. By the year 2030, domestic demand for electrical energy is expected to grow to levels of 16 to 36% higher than 2007 levels. At the same time, most currently operating nuclear power plants will begin reaching the end of their 60-year operating licenses. If current operating nuclear power plants do not operate beyond 60 years, the total fraction of generated electrical energy from nuclear power will begin to decline—even with the expected addition of new nuclear generating capacity. The oldest commercial plants in the United States reached their 40th anniversary this year. U.S. regulators have begun considering extended operations of nuclear power plants and the research needed to support long-term operations. The Light Water Reactor Sustainability (LWRS) Research and Development (R&D) Program, developed and sponsored by the Department of Energy, is performed in close collaboration with industry R&D programs. The purpose of the LWRS R&D Program is to provide technical foundations for licensing and managing long-term, safe and economical operation of the current operating nuclear power plants. The LWRS R&D Program vision is captured in the following statements: Existing operating nuclear power plants will continue to safely provide clean and economic electricity well beyond their first license- extension period, significantly contributing to reduction of United States and global carbon emissions, enhancement of national energy security, and protection of the environment. There is a comprehensive technical basis for licensing and managing the long-term, safe, economical operation of nuclear power plants. Sustaining the existing operating U.S. fleet also will improve its international engagement and leadership on nuclear safety and security issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Greenhouse gas emissions embodied in the U.S. solar photovoltaic supply chain

Abstract Solar photovoltaic (PV) electricity is considered to be an important source of electricity generation in the quest for net-zero carbon emissions. However, the growth of solar electricity is creating both increased material demands and increased greenhouse gas (GHG) emissions from silicon and PV manufacturing (also referred to as embodied GHG emissions of solar electricity). Here we analyze the silicon and solar PV supply chain for the United States (U.S.) market and find that the embodied GHG emissions of solar PV panel materials (such as silicon), manufacture, logistics, and installation in the U.S. given the current supply chain are 36 g CO 2 e kWh −1 of solar electricity generated. Eighty-five percent of the embodied GHG emissions are from PV panel production processes in China and other Asia–Pacific countries. Moving the silicon and PV manufacturing to the U.S. would reduce the embodied GHG emissions of solar electricity by 16% from its current level, primarily because of the lower GHG emission intensity of the U.S. electrical grid and the lower GHG emissions for aluminum electrolysis in North America. Future scenario analysis shows that by 2030, with the U.S. PV domestic supply chain and its decarbonized grid electricity and aluminum production, as well as improving PV conversion efficiency, the embodied GHG emissions of solar electricity in the U.S. will be reduced to 21 g CO 2 e kWh −1 .

14 SOLAR ENERGY↗

Aerodynamic generation of electric fields in turbulence laden with charged inertial particles

Self-induced electricity, including lightning, is routinely observed in dusty atmospheres. However, the physical mechanisms leading to this phenomenon remain elusive as they are remarkably challenging to determine due to the high complexity of the multi-phase turbulent flows involved. Using a fast multi-pole method in direct numerical simulations of homogeneous turbulence laden with hundreds of millions of inertial particles, here we show that mesoscopic electric fields can be aerodynamically created in bi-disperse suspensions of oppositely charged particles. The generation mechanism is self-regulating and relies on turbulence preferentially concentrating particles of one sign in clouds while dispersing the others more uniformly. The resulting electric field varies over much larger length scales than both the mean inter-particle spacing and the size of the smallest eddies. Scaling analyses suggest that low ambient pressures, such as those prevailing in the atmosphere of Mars, increase the dynamical relevance of this aerodynamic mechanism for electrical breakdown.

42 ENGINEERING↗

Targeted emission reductions from global super-polluting power plant units

There are more than 30,000 biomass- and fossil-fuel-burning power plants now operating worldwide, reflecting a tremendously diverse infrastructure, which ranges in capacity from less than a megawatt to more than a gigawatt. In 2010, 68.7% of electricity generated globally came from these power plants, compared with 64.2% in 1990. Although the electricity generated by this infrastructure is vital to economic activity worldwide, it also produces more CO2 and air pollutant emissions than infrastructure from any other industrial sector. Here, we assess fuel- and region-specific opportunities for reducing undesirable air pollutant emissions using a newly developed emission dataset at the level of individual generating units. For example, we find that retiring or installing emission control technologies on units representing 0.8% of the global coal-fired power plant capacity could reduce levels of PM2.5 emissions by 7.7–14.2%. In India and China, retiring coal-fired plants representing 1.8% and 0.8% of total capacity can reduce total PM2.5 emissions from coal-fired plants by 13.2% and 16.0%, respectively. Our results therefore suggest that policies targeting a relatively small number of ‘super-polluting’ units could substantially reduce pollutant emissions and thus the related impacts on both human health and global climate.

Tong, Dan↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off system, which is the mechanism by which the energy absorbed by the prime mover is transformed into usable electrical energy. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency), and devices will see a sinusoidal varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled power take-offs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the Reference Model Project sponsored by the U.S. Department of Energy. The Reference Model Project was a partnered effort to develop open-source marine energy point designs as reference models to benchmark marine energy technology performance and costs, methods for design and analysis of marine energy technologies, estimations for capital costs, operational costs, and levelized cost of energy. The results from this study show torque is directly related to (1) the physical size of the machine required to increase the air-gap sheer stresses, (2)the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both capital and operational expenditures. This paper aims to be a critical benchmark in helping determine an "optimal" nameplate rating for wave energy devices and their associated power take-offs. With an optimized rating and sizing process, WEC costs can be reduced and overall performance can be improved.

cables↗

Flexible wave energy converter

Disclosed herein are flexible wave energy converters that actuate electrical generators with dynamic strain (e.g., flexing, stretching, twisting, distension) to convert wave energy to electrical energy. The flexible wave energy converter utilizes flexible electric generators embedded throughout the wave-energy converter's flexible body.

16 TIDAL AND WAVE POWER↗

Flexible wave energy converter

Disclosed herein are flexible wave energy converters that actuate electrical generators with dynamic strain (e.g., flexing, stretching, twisting, distension) to convert wave energy to electrical energy. The flexible wave energy converter utilizes flexible electric generators embedded throughout the wave-energy converter's flexible body.

30 DIRECT ENERGY CONVERSION↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters: Preprint

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off (PTO) system, which is the mechanism by which the energy absorbed by the prime mover is transformed into useable electrical. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency) and devices will see a sinusoidally varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled PTOs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the DOE sponsored Reference Model Project (RMP). The RMP was a partnered effort to develop open-source marine energy (ME) point designs as reference models (RMs) to benchmark ME technology performance and costs, methods for design and analysis of ME technologies, estimations for capital costs, operational costs, and levelized costs of energy (LCOE). The results from this study show torque is directly related to (1) the physical size of the machine required to increase the airgap sheer stresses, (2) the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both CAPEX and OPEX. This paper aims to be a critical benchmark in helping determine an “optimal” nameplate rating for wave energy devices and their associated PTO. With an optimized rating and sizing process, WEC costs can be reduced, and overall performance can be improved.

cables↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off (PTO) system, which is the mechanism by which the energy absorbed by the prime mover is transformed into useable electrical. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency) and devices will see a sinusoidally varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled PTOs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the DOE sponsored Reference Model Project (RMP). The RMP was a partnered effort to develop open-source marine energy (ME) point designs as reference models (RMs) to benchmark ME technology performance and costs, methods for design and analysis of ME technologies, estimations for capital costs, operational costs, and levelized costs of energy (LCOE). The results from this study show torque is directly related to (1) the physical size of the machine required to increase the airgap sheer stresses, (2) the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both CAPEX and OPEX. This paper aims to be a critical benchmark in helping determine an “optimal” nameplate rating for wave energy devices and their associated PTO. With an optimized rating and sizing process, WEC costs can be reduced, and overall performance can be improved.

cables↗