Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVAPORATION RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Applications of High Etendue Line-Profile Spectro-Polarimetry to the Study of the Atmospheric and Magnetospheric Environments of the Jovian Icy Moons

Electrodynamic effects play a significant, global role in the state and energization of the Earth's ionosphere/magnetosphere, but even more so on Jupiter, where the auroral energy input is four orders of magnitude greater than on Earth. The Jovian magnetosphere is distinguished from Earth's by its rapid rotation rate and contributions from satellite atmospheres and internal plasma sources. The electrodynamic effects of these factors have a key role in the state and energization of the ionosphere-corona- plasmasphere system of the planet and its interaction with Io and the icy satellites. Several large scale interacting processes determine conditions near the icy moons beginning with their tenuous atmospheres produced from sputtering, evaporative, and tectonic/volcanic sources, extending out to exospheres that merge with ions and neutrals in the Jovian magnetosphere. This dynamic environment is dependent on a complex network of magnetospheric currents that act on global scales. Field aligned currents connect the satellites and the middle and tail magnetospheric regions to the Jupiter's poles via flux tubes that produce as bright auroral and satellite footprint emissions in the upper atmosphere. This large scale transfer of mass, momentum, and energy (e.g. waves, currents) means that a combination of complementary diagnostics of the plasma, neutral, and and field network must be obtained near simultaneously to correctly interpret the results. This presentation discusses the applicability of UV spatial heterodyne spectroscopy (SHS) to the broad study of this system on scales from satellite surfaces to Jupiter's aurora and corona.

Harris, Walter M.↗

Impact of TRMM and SSM/I-derived Precipitation and Moisture Data on the GEOS Global Analysis

Current global analyses contain significant errors in primary hydrological fields such as precipitation, evaporation, and related cloud and moisture in the tropics. The Data Assimilation Office at NASA's Goddard Space Flight Center has been exploring the use of space-based rainfall and total precipitable water (TPW) estimates to constrain these hydrological parameters in the Goddard Earth Observing System (GEOS) global data assimilation system. We present results showing that assimilating the 6-hour averaged rain rates and TPW estimates from the Tropical Rainfall Measuring Mission (TRMM) and Special Sensor Microwave/Imager (SSM/I) instruments improves not only the precipitation and moisture estimates but also reduce state-dependent systematic errors in key climate parameters directly linked to convection such as the outgoing longwave radiation, clouds, and the large-scale circulation. The improved analysis also improves short-range forecasts beyond 1 day, but the impact is relatively modest compared with improvements in the time-averaged analysis. The study shows that, in the presence of biases and other errors of the forecast model, improving the short-range forecast is not necessarily prerequisite for improving the assimilation as a climate data set. The full impact of a given type of observation on the assimilated data set should not be measured solely in terms of forecast skills.

Hou, Arthur Y.↗

Spiral Flow Separator

Proposed liquid-separating device relies on centrifugal force in liquid/liquid or liquid/solid mixture in spiral path. Operates in continuous flow at relatively high rates. Spiral tubes joined in sequence, with outlet tubes connected to joints. Cross-sectional areas of successive spiral tubes decreases by cross-sectional areas of outlet tubes. Centrifugal force pushes denser particles or liquids to outer edge of spiral, where removed from flow. Principle exploited to separate solids from wastewater, oil from fresh or salt water, or contaminants from salt water before evaporation. Also used to extract such valuable materials as precious metals from slurries.

Robertson, Glen A.↗

Spacesuit Portable Life Support System Breadboard (PLSS 1.0) Development and Test Results

A multi-year effort has been carried out at NASA-JSC to develop an advanced Extravehicular Activity (EVA) PLSS design intended to further the current state of the art by increasing operational flexibility, reducing consumables, and increasing robustness. Previous efforts have focused on modeling and analyzing the advanced PLSS architecture, as well as developing key enabling technologies. Like the current International Space Station (ISS) Extravehicular Mobility Unit (EMU) PLSS, the advanced PLSS comprises of three subsystems required to sustain the crew during EVA including the Thermal, Ventilation, and Oxygen Subsystems. This multi-year effort has culminated in the construction and operation of PLSS 1.0, a test rig that simulates full functionality of the advanced PLSS design. PLSS 1.0 integrates commercial off the shelf hardware with prototype technology development components, including the primary and secondary oxygen regulators, ventilation loop fan, Rapid Cycle Amine (RCA) swingbed, and Spacesuit Water Membrane Evaporator (SWME). Testing accumulated 239 hours over 45 days, while executing 172 test points. Specific PLSS 1.0 test objectives assessed during this testing include: confirming key individual components perform in a system level test as they have performed during component level testing; identifying unexpected system-level interactions; operating PLSS 1.0 in nominal steady-state EVA modes to baseline subsystem performance with respect to metabolic rate, ventilation loop pressure and flow rate, and environmental conditions; simulating nominal transient EVA operational scenarios; simulating contingency EVA operational scenarios; and further evaluating individual technology development components. Successful testing of the PLSS 1.0 provided a large database of test results that characterize system level and component performance. With the exception of several minor anomalies, the PLSS 1.0 test rig performed as expected; furthermore, many system responses trended in accordance with pre-test predictions.

Vogel, Matt R.↗

Chromium Brine Containment Membrane Demister for the CapiBRiC

The development of a microgravity air-evaporation urine brine dryer (CapiBRiC - Capillary Brine Residual in Containment) that releases its effluent gas into the cabin of the International Space Station will require some form of a demister to guarantee that no acid, chromium, or other hazardous materials are released within the effluent gas stream. A hydrophobic membrane demister can be used for this application, and can be compatible with the proposed high flow rates of the effluent gas stream. This paper will describe the construction and sizing of such a membrane demister.

CapiBRiC↗

Thermoelectric integrated membrane evaporation water recovery technology

The recently developed Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES) offers a highly competitive approach to water recovery from waste fluids for future on-orbit stations such as the Space Operations Center. Low power, compactness and gravity insensitive operation are featured in this vacuum distillation subsystem that combines a hollow fiber membrane evaporator with a thermoelectric heat pump. The hollow fiber elements provide positive liquid/gas phase control with no moving parts other than pumps and an accumulator, thus solving problems inherent in other reclamation subsystem designs. In an extensive test program, over 850 hours of operation were accumulated during which time high quality product water was recovered from both urine and wash water at an average steady state production rate of 2.2 pounds per hour.

Roebelen, G. J., Jr.↗

The Coronae of Moderate-Mass Giants in the Hertzsprung Gap and the Clump

We have used the Roentgensatellit (ROSAT), the Extreme Ultraviolet Explorer (EUVE), and the Hubble Space Telescope (HST) to measure X-ray and ultraviolet emissions of moderate-mass (APPROX. 2-3 solar mass) giants in the Hertzsprung gap (spectral types early F to mid-G) and the post-helium flash "clump" (approx. G8-K0). Our motivation was to document the evolution of hot coronae (T greater than 10(exp 6)K) along the post-main-sequence trajectories traveled by such stars in order to gain insight concerning the "X-ray deficiency" of the F-GO giants and the strong braking of stellar rotation at the red edge of the Hertzsprung gap. With few exceptions, Hertzsprung gap and clump giants observed by ROSAT PSPC show hot (T approx. 10(exp 7)K) coronal energy distributions, regardless of any X-ray deficiency, EUVE spectra of gap star 31 Com (G0 111) indicate a broad coronal emission measure hump at approx. 10(exp 7.2)K, while the active clump giant beta Ceti (K0 III) displays a sharp peak at approx. 10(exp 6.8)K, as seen previously in the mixed clump/gap binary Capella (alpha Aur: G8 III + G0 III). The gap giants upsilon Peg (F8 III) and 24 UMa (G4 III) have EUV emissions of intermediate temperature (approx. 10(exp 7.0)K). The stars 31 Com, psi(sup 3) Psc (G0 III), and beta Cet exhibit redshifted transition zone (TZ: approx. 10(exp 5)K) lines in HST GHRS spectra, as reported earlier in Procyon (alpha CMi: F5 IV-V) and Capella G0. Such redshifts on the Sun are thought to signify flows in magnetic loops. beta Cas (F2 III)-a rare soft coronal source among the gap stars-displays blueshifts of C iv and 0 iv], although emissions at cooler and hotter temperatures are near the photospheric velocity. The remarkably broad line profiles of the fastest rotating gap giants suggest that the 10(exp 5) K "subcoronal " emission zones extend to h approx. R(sub *) above the photosphere, about 50 scale heights. In contrast to the TZ line redshifts, the upper chromospheric emissions (e.g., Mg II and Si III) of 31 Com and upsilon(sup 3) Psc have blueshifted cores. Blue-asymmetric peaks in the solar Mg a lines are thought to indicate dynamical heating in the chromosphere. Observations of the H(sub I) Ly(alpha) feature of 31 Com taken 9 months apart reveal striking profile changes, reminiscent of those noted previously in the Ly(alpha) blue peak of the Capella G0 star. We used the far-ultraviolet diagnostics, in combination with ROSAT X-ray photometry and EUVE high-excitation line strengths, to constrain physical models of the stellar outer atmospheres. Quasi-static magnetic loops can simulate the empirical coronal emission measures of the giant stars, but the inferred pressures for sensible loop lengths conflict with direct measurements of subcoronal densities. Furthermore, the high rate of emission at approx. 10(exp 5) K cannot be explained by thermal conduction down the legs of hot quasi-static loops. On the other hand, the possible existence of elongated (l - R(sub *) emission structures on the gap giants leads to a speculative scenario to explain the X-ray deficiency. It is based on the increased importance of the dynamical filling phase ("explosive evaporation") of the loop life cycle; conductive cooling, yielding TZ emissions at the footpoints, when the heating is interrupted; and the possibility for transitions between " hot " and " cool " energy balance solutions owing to dynamical suspension and centrifugal trapping of the cooling gas. The long loops might represent a vestigial global " magnetosphere " inherited from the main-sequence phase, which ultimately is disrupted near approx. G0 by the deepening convective envelope and growth of a more solar-like dynamo. Coronal emissions might be boosted temporarily as the X-ray deficiency is removed but soon would be quenched by wind braking previously inhibited by the magnetospheric "dead zone."

Ayres, Thomas R.↗

Possible Influences of Air Pollution, Dust and Sandstorms on the Indian Monsoon

In Asian monsoon countries, such as China and India, human health and safety problems caused by air pollution are becoming increasingly serious, due to the increased loading of atmospheric pollutants from waste gas emissions and from rising energy demand associated with the rapid pace of industrialization and modernization. Meanwhile, uneven distribution of monsoon rain associated with flash floods or prolonged drought, has caused major loss of human life and damage to crops and.property with devastating societal impacts. Historically, air-pollution and monsoons research are treated as separate problems. However recent studies have suggested that the two problems may be intrinsically linked and need to be studied jointly. Fundamentally, aerosols can affect precipitation through radiative effects cif suspended particles in the atmosphere (direct effect) and/or by interfering and changing: the cloud and precipitation formation processes (indirect effect). Based on their optical properties, aerosols can be classified into two types.: those that absorb solar radiation, and those that do not. Both types of aerosols scatter sunlight and reduce the amount of solar radiation from reaching the Earth's surface, causing it to cool. The surface cooling increases atmospheric stability and reduces convection potential, Absorbing aerosols, however, in addition to cooling the surface, can heat the atmosphere. The heating of the atmosphere may reduce the amount of low clouds by increased evaporation in cloud drops. The heating, however, may induce rising motion, enhance low-level moisture, convergence and, hence, increases rainfall, The latent heating from enhanced rainfall may excite feedback processes in the large-scale circulation, further amplify.the initial response to aerosol heating and producing more rain. Additionally, aerosols can increase the concentration of cloud condensation nuclei (CCN), increase cloud amount and decrease coalescence and collision rates, leading to reduced precipitation. However, in the presence of increasing moist and warm air, the reduced coalescence/collision may lead to supercooled drops at higher altitudes where ice precipitation falls and melts. The latent heat release from freezing aloft and melting below implies greater upward heat transport in polluted clouds and invigorate deep convection. In this way, aerosols may lead to increased local convection. Hence, depending on the ambient large-scale conditions and dynamical feedback processes, aerosols' effect on precipitation can be positive, negative or mixed. In the Asian monsoon and adjacent regions, the aerosol forcing and responses of the water cycle are even more complex, Both direct and indirect effects may take place locally and simultaneously, interacting with each other. in addition to local effects, monsoon rainfall may be affected by aerosols transported from other regions and intensified through large-scale circulation and moisture feedback. Thus, dust transported by the large-scale circulation from the adjacent deserts to northern India may affect rainfall over the Bay of Bengal; sulphate and black carbon front industrial pollution in central, southern China and northern India may affect the rainfall regime over the Korean peninsula and Japan; organic and black carbon front biomass burning from Indo-China may modulate the pre-monsoon rainfall regime over southern China and coastal regions, contributing to variability in differential heating and cooling of the atmosphere and to the land-sea thermal contrast. During the pre-monsoon season and monsoon breaks, it has been suggested that radiative forcing by absorbing aerosols have nearly the same order of magnitude as the forcing due to latent heating from convection and surface fluxes. The magnitude of the total aerosol radiative cooling due to sulphates and soot is of the order of 20-40 W/m2 over the Asian monsoon land region in the pre-monsoon season, compared to about 1-2 W/m2 for global warng. However, the combined forcing at the surface and in the atmosphere, including all species. if aerosols, and details of aerosol mixing, and impacts on the energy and water cycles in the monsoon land regions, are not well known.

Lau, William K. M.↗

Particle Trajectory and Icing Analysis of the E(sup 3) Turbofan Engine Using LEWICE3D Version 3

Particle trajectory and ice shape calculations were made for the Energy Efficient Engine (E(sup 3)) using the LEWICE3D Version 3 software. The particle trajectory and icing computations were performed using the new "block-to-block" collection efficiency method which has been incorporated into the LEWICE3D Version 3 software. The E(sup 3) was developed by NASA and GE in the early 1980 s as a technology demonstrator and is representative of a modern high bypass turbofan engine. The E(sup 3) flow field was calculated using the NASA Glenn ADPAC turbomachinery flow solver. Computations were performed for the low pressure compressor of the E(sup 3) for a Mach 0.8 cruise condition at 11,887 m assuming a standard warm day for three drop sizes and two drop distributions typically used in aircraft design and certification. Particle trajectory computations were made for water drop sizes of 5, 20, and 100 microns. Particle trajectory and ice shape predictions were made for a 20 micron Langmuir-D distribution and for a 92 mm Super-cooled Large Droplet (SLD) distribution with and without splashing effects for a Liquid Water Content (LWC) of 0.3 g/cu m and an icing time of 30 min. The E3 fan and spinner combination proved to be an effective ice removal mechanism as they removed greater than 36 percent of the mass entering the inlet for the icing cases. The maximum free stream catch fraction for the fan and spinner combination was 0.60 while that on the elements downstream of the fan was 0.03. The non-splashing trajectory and collection efficiency results showed that as drop size increased impingement rates increased on the spinner and fan leaving less mass to impinge on downstream components. The SLD splashing case yielded more mass downstream of the fan than the SLD non-splashing case due to mass being splashed from the upstream inlet lip, spinner and fan components. The ice shapes generated downstream of the fan were either small or nonexistent due to the small available mass and evaporation except for the 92 m SLD splashing case. Relatively large ice shapes were predicted for internal guide vane #1 and rotor #1 for the 92 m SLD splashing case due to re-impingement of splashed mass.

Bidwell, Colin S.↗

Classical thermal evaporation of clouds - An electrostatic analogy

The dynamics of the thermal evaporation of cool gas clouds embedded in a hot ionized gas is considered from a general point of view. The investigation is limited to isobaric small Mach number flow, the heat flux given by the diffusive electron Coulomb scattering formula, and no external heating sources. The cloud boundaries are assumed to change very slowly relative to the flow time. It is concluded that the classical mass-loss rate of any irrotational flow from a cloud ensemble is the product of known quantities and the electrostatic capacitance of an identical ensemble of grounded electrical conductors. Thus, the mass loss rate from an ensemble of clouds may be dramatically lower than the sum of the isolated cloud mass-loss rates. This rate is a lower bound to the mass-loss rate when vorticity is present. The mass-loss rate reaches its minimum value when the vorticity flow streamlines are isotherms.

Balbus, S. A.↗

Arsenic-induced intensity oscillations in reflection high-energy electron diffraction measurements

A technique of arsenic-induced RHEED intensity oscillations has been used to accurately measure arsenic incorporation rates as a function of substrate temperature during the homoepitaxial growths of both GaAs and InAs by molecular beam epitaxy (MBE). Measurements were made at growth temperatures from 350 to 650 C and at arsenic fluxes of 0.1 to 10.0 monolayer/s. The method measures only the arsenic actually incorporated into the growing film and does not include the arsenic lost in splitting the arsenic tetramers or lost by evaporation from the sample.

Lewis, B. F.↗

Influences of Local Sea-Surface Temperatures and Large-scale Dynamics on Monthly Precipitation Inferred from Two 10-year GCM-Simulations

Two parallel sets of 10-year long: January 1, 1982 to December 31, 1991, simulations were made with the finite volume General Circulation Model (fvGCM) in which the model integrations were forced with prescribed sea-surface temperature fields (SSTs) available as two separate SST-datasets. One dataset contained naturally varying monthly SSTs for the chosen period, and the oth& had the 12-monthly mean SSTs for the same period. Plots of evaporation, precipitation, and atmosphere-column moisture convergence, binned by l C SST intervals show that except for the tropics, the precipitation is more strongly constrained by large-scale dynamics as opposed to local SST. Binning data by SST naturally provided an ensemble average of data contributed from disparate locations with same SST; such averages could be expected to mitigate all location related influences. However, the plots revealed: i) evaporation, vertical velocity, and precipitation are very robust and remarkably similar for each of the two simulations and even for the data from 1987-ENSO-year simulation; ii) while the evaporation increased monotonically with SST up to about 27 C, the precipitation did not; iii) precipitation correlated much better with the column vertical velocity as opposed to SST suggesting that the influence of dynamical circulation including non-local SSTs is stronger than local-SSTs. The precipitation fields were doubly binned with respect to SST and boundary-layer mass and/or moisture convergence. The analysis discerned the rate of change of precipitation with local SST as a sum of partial derivative of precipitation with local SST plus partial derivative of precipitation with boundary layer moisture convergence multiplied by the rate of change of boundary-layer moisture convergence with SST (see Eqn. 3 of Section 4.5). This analysis is mathematically rigorous as well as provides a quantitative measure of the influence of local SST on the local precipitation. The results were recast to examine the dependence of local rainfall on local SSTs; it was discernible only in the tropics. Our methodology can be used for computing relationship between any forcing function and its effect(s) on a chosen field.

Sud, Y. C.↗

High-purity silicon crystal growth investigations

Information is given on evaporation and segregation contributions to impurity profiles of floating zone crystals (FZ); high-purity silicon float zoning (FZ); minority-carrier lifetime measurement of heavily doped silicon crystals; the effect of some crystal growth parameters on minority-carrier lifetime; and defect investigations by X-ray topography in graphical and tabular form. It was concluded that evaporation contributes substantially to impurity reduction when FZ or cold-crucible growth is conducted in a vacuum; boron and gallium may be more favorable dopants than indium or aluminum for obtaining high minority-carrier lifetimes; minority-carrier lifetimes greater than 100 microseconds are feasible at a 2 times 10 to the 17th power cm-3 doping level; minority-carrier lifetime decreases with increasing crystal cooling rate and also with the presence of dislocations; the method used to clean silicon feed rods affects lifetime; and microdefect densities in dislocation-free FZ crystals appear to be lower with Ga doping than with B doping.

Ciszek, T. F.↗

Hollow Fiber Ground Evaporator Unit Testing

A candidate technology for 1-atmosphere suited heat rejection was developed and tested at NASA Johnson Space Center. The concept is to use a collection of microporous hydrophobic tubes potted between inlet and outlet headers with water as coolant. A pump provides flow between headers through the tubes which are subjected to fan driven cross flow of relatively dry air. The forced ventilation would sweep out the water vapor from the evaporation of the coolant rejecting heat from the coolant stream. The hollow fibers are obtained commercially (X50-215 Celgard) which are arranged in a sheet containing 5 fibers per linear inch. Two engineering development units were produced that vary the fold direction of the fiber sheets relative to the ventilation. These units were tested at inlet water temperatures ranging from 20 deg C to 30 deg C, coolant flow rates ranging from 10 to 90 kg/hr, and at three fan speeds. These results were used to size a system that could reject heat at a rate of 340 W.

Bue, Grant↗

The role of water in slip casting

Slips and casting are considered in terms of physical and colloidal chemistry. Casting slips are polydisperse suspensions of lyophobic particles in water, whose degree of coagulation is controlled by interaction of flocculating and deflocculating agents. Slip casting rate and viscosity are functions of temperature. Slip rheology and response to deflocculating agents varies significantly as the kinds and amounts of colloid modifiers change. Water is considered as a raw material. Various concepts of water/clay interactions and structures are discussed. Casting is a de-watering operation in which water moves from slip to cast to mold in response to a potential energy termed moisture stress. Drying is an evaporative process from a free water surface.

Mccauley, R. A.↗

Observational study of ion-electron equilibration and of cloud evaporation in supernova remnants under the HEAO-2 guest investigator program

Observations of three selected supernovae remnants (Cygnus Loop, IC 443, and Puppis A) were made in the forbidden coronal iron lines (Fe X) lambda 6374 and (Fe XIV) lambda 5303. The resulting data was compared quantitatively with Einstein images of the same objects, and an attempt was made to determine (a) the process by which ion and electron energies are equilibrated behind the shock front in the ISM and (b) whether cloud evaporation occurs within the hot remnant interiors. Spatially-resolved X ray emission were modeled for Sedov-Taylor blast wave models of supernovae remnants (SNR) under conditions of non-equlibrium ionization. The computations are intended to provide results that can be directly compared with Einstein high resolution image (HRI) and imaging proportional counter (IPS) data. The computer program for predicting the spatial distribution of HRI and IPS counting rates was completed, and final testing of it had begun.

Teske, R. G.↗

Computational simulation of liquid rocket injector anomalies

A computer model has been developed to analyze the three-dimensional two-phase reactive flows in liquid fueled rocket combustors. The model is designed to study the influence of liquid propellant injection nonuniformities on the flow pattern, combustion and heat transfer within the combustor. The Eulerian-Lagrangian approach for simulating polidisperse spray flow, evaporation and combustion has been used. Full coupling between the phases is accounted for. A nonorthogonal, body fitted coordinate system along with a conservative control volume formulation is employed. The physical models built into the model include a kappa-epsilon turbulence model, a two-step chemical reaction, and the six-flux radiation model. Semiempirical models are used to describe all interphase coupling terms as well as chemical reaction rates. The purpose of this study was to demonstrate an analytical capability to predict the effects of reactant injection nonuniformities (injection anomalies) on combustion and heat transfer within the rocket combustion chamber. The results show promising application of the model to comprehensive modeling of liquid propellant rocket engines.

Przekwas, A. J.↗

Design and test of a mechanically pumped two-phase thermal control flight experiment

A flight experiment of a mechanically pumped two-phase ammonia thermal control system, incorporating a number of new component designs, has been assembled and tested in a 1-g environment. Additional microgravity tests are planned on the Space Shuttle when Shuttle flights are resumed. The primary purpose of this experiment is to evaluate the operation of a mechanically pumped two-phase ammonia system, with emphasis on determining the performance of an evaporative Two-Phase Mounting Plate. The experiment also evaluates the performance of other specially designed components, such as the two-phase reservoir for temperature control, condensing radiator/heat sink, spiral tube boiler, and pressure drop experiment. The 1-g tests have shown that start-up of the two-phase experiment is easily accomplished with only a partial fill of ammonia. The experiment maintained a constant mounting plate temperature without flow rate controls over a very wide range of heat loads, flow rates, inlet flow conditions and exit qualities. The tests also showed the successful operation of the mounting plate in the heat sharing condensing mode.

Grote, M. G.↗