Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Science with the Space Infrared Telescope Facility

The Space Infrared Telescope Facility (SIRTF), the fourth and final member of NASA's series of Great Observatories, is scheduled to launch on April 15,2003. Together with the Hubbie Space Telescope, the Compton Gamma ray Telescope, and the Chandra X-Ray Telescope this series of observatories offers observational capabilities across the electromagnetic spectrum from the infrared to high-energy gamma rays. SIRTF is based on three focal plane instruments - an infrared spectrograph and two infrared imagers - coupled to a superfluid-helium cooled telescope to achieve unprecedented sensitivity from 3 to 180 microns. Although SIRTF is a powerful general-purpose infrared observatory, its design was based on the capability to address four broad science themes: (1) understanding the structure and composition of the early universe, (2) understanding the nature of brown dwarfs and super-planets, (3) probing protostellar, protoplanetary, and planetary debris disk systems, and (4) understanding the origin and structure of ultraluminous infrared galaxies and active galactic nuclei. This talk will address the design and capabilities of the SIRTF observatory, provide an overview of some of the initial science investigations planned by the SIRTF Guaranteed Time Observers, and give a brief overview of the General Observer proposal process.

Roellig, Thomas L.↗

Force Balance at the Magnetopause Determined with MMS: Application to Flux Transfer Events

The Magnetospheric Multiscale mission (MMS) consists of four identical spacecraft forming a closely separated (less than or equal to 10 km) and nearly regular tetrahedron. This configuration enables the decoupling of spatial and temporal variations and allows the calculation of the spatial gradients of plasma and electromagnetic field quantities. We make full use of the well cross-calibrated MMS magnetometers and fast plasma instruments measurements to calculate both the magnetic and plasma forces in flux transfer events (FTEs) and evaluate the relative contributions of different forces to the magnetopause momentum variation. This analysis demonstrates that some but not all FTEs, consistent with previous studies, are indeed force-free structures in which the magnetic pressure force balances the magnetic curvature force. Furthermore, we contrast these events with FTE events that have non-force-free signatures.

MMS↗

Atmospheric Instrument Systems and Technology in the Goddard Earth Sciences Division

Studies of the Earth’s atmosphere require a comprehensive set of observations that rely on instruments flown on spacecraft, aircraft, and balloons as well as those deployed on the surface. Within NASA’s Goddard Space Flight Center (GSFC) Earth Sciences Division-Atmospheres, laboratories and offices maintain an active program of instrument system development and observational studies that provide: 1) information leading to a basic understanding of atmospheric processes and their relationships with the Earth’s climate system, 2) prototypes for future flight instruments, 3) instruments to serve as calibration references for satellite missions, and 4) instruments for future field validation campaigns that support ongoing space missions. Our scientists participate in all aspects of instrument activity, including component and system design, calibration techniques, retrieval algorithm development, and data processing systems. The Atmospheres Program has well-equipped labs and test equipment to support the development and testing of instrument systems, such as a radiometric calibration and development facility to support the calibration of ultraviolet and visible (UV/VIS), space-borne solar backscatter instruments. This document summarizes the features and characteristics of 46 instrument systems that currently exist or are under development. The report is organized according to active, passive, or in situ remote sensing across the electromagnetic spectrum. Most of the systems are considered operational in that they have demonstrated performance in the field and are capable of being deployed on relatively short notice. Other systems are under study or of low technical readiness level (TRL). The systems described herein are designed mainly for surface or airborne platforms. However, two Cubesat systems also have been developed through collaborative efforts. The Solar Disk Sextant (SDS) is the single balloon-borne instrument. The lidar systems described herein are designed to retrieve clouds, aerosols, methane, water vapor pressure, temperature, and winds. Most of the lasers operate at some wavelength combination of 355, 532, and 1064 nm. The various systems provide high sensitivity measurements based on returns from backscatter or Raman scattering including intensity and polarization. Measurements of the frequency (Doppler) shift of light scattered from various atmospheric constitutes can also be made. Microwave sensors consist of both active (radar) and passive (radiometer) systems. These systems are important for studying processes involving water in various forms. The dielectric properties of water affect microwave brightness temperatures, which are used to retrieve atmospheric parameters such as rainfall rate and other key elements of the hydrological cycle. Atmosphere radar systems operate in the range from 9.6 GHz to 94 GHz and have measurement accuracies from -5 to 1 dBZ; radiometers operate in the 50 GHz to 874 GHz range with accuracies from 0.5 to 1 degree K; conical and cross-track scan modes are used. Our passive optical sensors, consisting of radiometers and spectrometers, collectively operate from the UV into the infrared. These systems measure energy fluxes and atmospheric parameters such as trace gases, aerosols, cloud properties, or altitude profiles of various species. Imager spatial resolution varies from 37 m to 400 m depending on altitude; spectral resolution is as small as 0.5 nm. Many of the airborne systems have been developed to fly on multiple aircraft.

Platnick, Steven E.↗

Dynamical Casimir effect in superconducting microwave circuits

We theoretically investigate the dynamical Casimir effect (DCE) in electrical circuits based on superconducting microfabricated waveguides with tunable boundary conditions. We propose implementing a rapid modulation of the boundary conditions by tuning the applied magnetic flux through superconducting quantum-interference devices that are embedded in the waveguide circuits. We consider two circuits: (i) An open waveguide circuit that corresponds to a single mirror in free space, and (ii) a resonator coupled to a microfabricated waveguide, which corresponds to a single-sided cavity in free space. We analyze the properties of the DCE in these two setups by calculating the generated photon-flux densities, output-field correlation functions, and the quadrature squeezing spectra. We show that these properties of the output field exhibit signatures unique to the radiation due to the DCE, and could, therefore, be used for distinguishing the DCE from other types of radiation in these circuits. We also discuss the similarities and differences between the DCE, in the resonator setup, and the down-conversion of pump photons in parametric oscillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of pump coherence in two-photon interferometry

We use a parametric down-conversion source pumped by a short-coherence-length continuous-wave (CW) diode laser to perform two-photon interferometry in an intermediate regime between the more familiar Franson-type experiments with a long-coherence-length pump laser, and the short pulsed pump ''time-bin'' experiments pioneered by Gisin's group. The use of a time-bin-like Mach-Zehnder interferometer in the CW pumping beam induces coherence between certain two-photon amplitudes, while the CW nature of the experiment prevents the elimination of remaining incoherent ones. The experimental results highlight the role of pump coherence in two-photon interferometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermorefractive and thermochemical noise in the beamsplitter of the GEO600 gravitational-wave interferometer

Braginsky, Gorodetsky, and Vyatchanin have shown that thermorefractive fluctuations are an important source of noise in interferometric gravitational-wave detectors. In particular, the thermorefractive noise in the GEO600 beamsplitter is expected to make a substantial contribution to the interferometer's total noise budget. Here, we present a new computation of the GEO600 thermorefractive noise, which takes into account the beam's elliptical profile and, more importantly, the fact that the laser beam induces a standing electromagnetic wave in the beamsplitter. The use of updated parameters results in the overall reduction of the calculated noise amplitude by a factor of {approx}5 in the low-frequency part of the GEO600 band, compared to the previous estimates. We also find, by contrast with previous calculations, that thermorefractive fluctuations result in white noise between 600 Hz and 39 MHz, at a level of 8.5{center_dot}10{sup -24} Hz{sup -1/2}. Finally, we describe a new type of thermal noise, which we call the thermochemical noise. This is caused by a random motion of optically active chemical impurities or structural defects in the direction along a steep intensity gradient of the standing wave. We discuss the potential relevance of the thermochemical noise for GEO600.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic Simulations of Newly Designed Semiconductor Bolometers for Submillimeter Observations

In the frame of the SPICA mission, new semiconductor bolometers have been designed for the POL instrument which is directly part of the HERSCHEL/PACS legacy. These detectors are cooled down to 50 mK and are sensitive to polarization for the 100, 200 and 350 μm wavelength bands. In this paper, 3D simulations have been carried out with the COMSOL Multiphysics software to design the two suspended interlaced silicon spirals which support the orthogonal absorbers (sensitive to the two polarizations) of the POL detectors. These simulations allow to optimize the design of the absorbers and to quantify the cross-polarization. In the last part of this paper, we explain how it is possible to reach the 200 and 350 μm bands from the layout of the 100-μm detector.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Foreword to the Special Issue on the 11th Specialist Meeting on Microwave Radiometry and Remote Sensing Applications (MicroRad 2010)

The Specialist Meeting on Microwave Radiometry and Remote Sensing of the Environment (MicroRad 2010) was held in Washington, DC from March 1 to 4, 2010. The objective of MicroRad 2010 was to provide an open forum to report and discuss recent advances in the field of microwave radiometry, particularly with application to remote sensing of the environment. The meeting was highly successful, with more than 200 registrations representing 48 countries. There were 80 oral presentations and more than 100 posters. MicroRad has become a venue for the microwave radiometry community to present new research results, instrument designs, and applications to an audience that is conversant in these issues. The meeting was divided into 16 sessions (listed in order of presentation): 1) SMOS Mission; 2) Future Passive Microwave Remote Sensing Missions; 3) Theory and Physical Principles of Electromagnetic Models; 4) Field Experiment Results; 5) Soil Moisture and Vegetation; 6) Snow and Cryosphere; 7) Passive/Active Microwave Remote Sensing Synergy; 8) Oceans; 9) Atmospheric Sounding and Assimilation; 10) Clouds and Precipitation; 11) Instruments and Advanced Techniques I; 12) Instruments and Advanced Techniques II; 13) Cross Calibration of Satellite Radiometers; 14) Calibration Theory and Methodology; 15) New Technologies for Microwave Radiometry; 16) Radio Frequency Interference.

Le Vine, David M↗

Space-time development of electromagnetic and hadronic showers and perspectives for novel calorimetric techniques

The performance of hadronic calorimeters will be a key parameter at the next generation of High Energy Physics accelerators. A detector combining fine granularity with excellent timing information would prove beneficial for the reconstruction of both jets and electromagnetic particles with high energy resolution. In this work, the space and time structure of high energy showers is studied by means of a Geant4-based simulation toolkit. In particular, the relevant time scales of the different physics phenomena contributing to the energy loss are investigated. A correlation between the fluctuations of the energy deposition of high energy hadrons and the time development of the showers is observed, which allows for an event-by-event correction to be computed to improve the energy resolution of the calorimeter. Lastly, these studies are intended to set the basic requirements for the development of a new-concept, total absorption time-imaging calorimeter, which seems now within reach thanks to major technological advancements in the production of fast scintillating materials and compact photodetectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic material changes for remote detection and monitoring: a feasibility study: Progress report

A new concept for radiation detection is proposed, allowing a decoupling of the sensing medium and the readout. An electromagnetic material, such as a magnetic ceramic ferrite, is placed near a source to be tracked such as a shipping container. The electromagnetic material changes its properties, in this case its magnetic permeability, as a function of radiation. This change is evident as a change in reflection frequency and magnitude when probed using a microwave/millimeter-wave source. This brief report discusses modeling of radiation interaction of various candidate materials using a radiation detector modeling code Geant4, system design considerations for the remote readout, and some theory of the material interaction physics. The theory of radiation change in doped magnetic insulator ferrites such as yttrium iron garnet (YIG) seems well founded based on literature documentation of the photomagnetic effect. The literature also suggests sensitivity of permittivity to neutrons in some ferroelectrics. Research to date indicates that experimental demonstration of these effects in the context of radiation detection is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum interference in photonic lattices with defects

Light trapping in photonic lattices at a linear defect shows interesting nonclassical behavior when probed by maximally path-entangled N-photon states (NOON states). In particular, photon coincidences of localized light at the defect oscillate at a spatial frequency that is N times faster than the classical beating spatial frequency of the defect modes, resembling the {lambda}/N oscillations of NOON states encountered in Mach-Zehnder interferometry. Analytical results of quantum interference are presented for an exactly solvable tight-binding waveguide array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Focal Surface of the JEM-EUSO Instrument

The Extreme Universe Space Observatory on JEM/EF (JEM-EUSO) is a space mission to study extremely high-energy cosmic rays. The JEM-EUSO instrument is a wide-angle refractive telescope in the near-ultraviolet wavelength region which will be mounted to the International Space Station. Its goal is to measure time-resolved fluorescence images of extensive air showers in the atmosphere. In this paper we describe in detail the main features and technological aspects of the focal surface of the instrument. The JEM-EUSO focal surface is a spherically curved surface, with an area of about 4.5m{sup 2}. The focal surface detector is made of more than 5,000 multi-anode photomultipliers (MAPMTs). Current baseline is Hamamatsu R11265-03-M64. The approach to the focal surface detector is highly modular. Photo-Detector-Modules (PDM) are the basic units that drive the mechanical structure and data acquisition. Each PDM consists of 9 Elementary Cells (ECs). The EC, which is the basic unit of the MAPMT support structure and of the front-end electronics, contains 4 units of MAPMTs. In total, about 1,200 ECs or about 150 PDMs are arranged on the whole of the focal surface of JEM-EUSO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of GSO scintillator for the LHCf upgrade

The GSO scintillator has a very excellent radiation resistance, fast decay time and large amounts of light yield. Because of these features, GSO will be used to upgrade the current LHCf detector. We examined the features of GSO by using heavy ion beam at Heavy Ion Medical Accelerator in Chiba (HIMAC) Japan. The linearity of PMT R7400 for the large light yield of GSO with a {sup 132}Xe beam and the radiation hardness with a {sup 12}C beam were measured. As a result, GSO scintillator showed a good linearity up to the signal corresponding to 6 TeV EM-shower maximum in the LHCf detector, and a good radiation hardness up to 7x10{sup 5} Gy. For the LHCf Arm1 detector, small scaled GSO crystals (GSO bars), have been fabricated for the position determination detector. 5 GSO bars have been manufactured and its performance have been evaluated using {sup 12}C beam. Its light yield and position dependency have been evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SelenITA: A dual-spacecraft lunar CubeSat mission to characterize the near-surface electromagnetic plasma environment

SelenITA is an international interdisciplinary mission consisting of two CubeSats that will provide the first multi-point measurement in a sustained low lunar orbit. This mission will advance the understanding of spatiotemporal differentiation of the electromagnetic space environment at the Moon in support of Artemis crew and the geosciences. The mission science objectives are to: (1) further constrain the origins of crustal magnetic fields and their applications; (2) determine the nature of plasma interactions with crustal magnetic fields; (3) characterize plasma waves and turbulence at the Moon; (4) characterize the lunar surface potential in all plasma environments; (5) constrain the composition, thermal state, and structure of the lunar upper mantle and crust; (6) characterize the ionizing radiation in lunar orbit; (7) determine the density of the dust exosphere as a function of latitude, longitude, and altitude, including the lunar polar space environment. The measurement requirements include: 3-component vector magnetic field, plasma distribution (flux, energy, density, temperature), energetic particles (protons, electrons, gamma rays), and dust. SelenITA builds on a rich history of electromagnetic plasma observations of the near lunar surface and space environment, and it answers high level science questions with state of the art instruments in a small package. PLAIN LANGUAGE ABSTRACT – SelenITA comes from the greek word for Moon, selene, with the addition of “ITA” as a reference to the Brazilian teammate, Instituto Tecnológico de Aeronáutica. In addition, in Portuguese "ita" is a prefix similar to "ite" in English, used in naming minerals, so Selenita could be seen as a lunar gemstone. In Spanish, “ita” is a diminutive suffix for “little” which is appropriate for this CubeSat mission which consists of twin 12U CubeSats in low lunar orbit. The primary science goal of the mission is to distinguish time varying features within the electromagnetic plasma environment near the surface of the Moon. The science objectives include investigating the origins of crustal magnetic fields, plasma interactions with these fields, plasma waves, surface potential, and interior properties. This mission is also interested in the radiation environment at the Moon and the amount of dust at the lunar poles. This is important because it helps us understand how future astronauts will live and work on the lunar surface and identify hazards.

space weather↗