Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRIC NETWORK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Spontaneous formation of InGaN nanowall network directly on Si

We present the study on epitaxial growth of an InGaN nanowall network directly on Si by plasma-assisted molecular beam epitaxy. Scanning electron microscopy, high-resolution X-ray diffraction, and transmission electron microscopy together with energy-dispersive X-ray analysis infer the crystalline nature of the InGaN nanowall network, oriented along the C-axis, with In composition ranging from pure GaN to 40%. Room temperature photoluminescence is observed, indicating good optical quality. The nanowall network is highly in-plane electrically conductive.

36 MATERIALS SCIENCE↗

Manipulating the ferromagnetism in narrow-bandwidth Pr{sub 1-x}Ca{sub x}MnO{sub 3} (0 ≤ x ≤ 0.6) by means of the Mn-Ru t{sub 2g} ferromagnetic super-exchanges

The concurrent ferromagnetic and metal-insulator transitions via the double-exchange route and electronic phase separation scenario represent the core ingredients of the physics of manganites. In this work, a Ca{sup 2+} and Ru{sup 4+} co-substitution of Pr{sup 3+} and Mn{sup 3+} in narrow-bandwidth and insulating PrMnO{sub 3}, namely, Pr{sub 1-x}Ca{sub x}Mn{sub 1-x}Ru{sub x}O{sub 3} (PCMRO, x ≤ 0.6), is carried out in order to investigate an alternative approach to effectively manipulate the ferromagnetism of PrMnO{sub 3}-based manganites. It is revealed that PCMRO over the whole substitution range is homogeneous solid solution with increased lattice distortion. The preference of Ru{sup 4+} valence state and the absence of Mn{sup 4+} valence state disable the Mn{sup 3+}-Mn{sup 4+} e{sub g}-orbital double-exchange, and the random occupation of Ru{sup 4+} in the lattice excludes the charge ordering and electronic phase separation. While all these consequences should favor antiferromagnetic insulating states, nevertheless, a high-temperature ferromagnetic transition is triggered by the co-substitution and the magnetization can reach up to ∼1.0 μ{sub B}/f.u. at x ∼ 0.2–0.3, much bigger than the moment (<0.1 μ{sub B}/f.u.) of Pr{sub 1−x}Ca{sub x}MnO{sub 3} in the weak ferromagnetic insulator state. It is suggested that this strong ferromagnetism is substantially ascribed to the Mn{sup 3+}-Ru{sup 4+} t{sub 2g}-orbital ferromagnetic super-exchange, and a simple geometric network illustration of the magnetism and electrical transport is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focus on monitoring and control of complex supply systems

The ongoing rapid transformation of our energy supply challenges the operation and stability of electric power grids and other supply networks. This focus issue comprises new ideas and concepts in the monitoring and control of complex networks to address these challenges.

97 MATHEMATICS AND COMPUTING↗

Deep Reinforcement Learning for Distribution System Operations: A Tutorial and Survey

Here, the rapid evolution of modern electric power distribution systems into complex networks of interconnected active devices, distributed generation (DG), and storage poses increasing difficulties for system operators. The large-scale integration of distributed energy resources (DERs) and the rapid exchange of measurement data via communication networks present major opportunities for advancing grid operations but also introduce greater uncertainty, higher data dimensionality, more complex network and device models, and challenging control and optimization problems. Deep reinforcement learning (DRL) algorithms are promising in addressing these challenges. However, they have not been effectively adapted for power systems applications, requiring extensive customization for implementation and evaluation. This has resulted in reproducibility challenges and a steep learning curve for researchers new to applying DRL algorithms to the power systems domain. To bridge these gaps, this tutorial aims to serve as a valuable resource for researchers interested in exploring learning-based algorithms to operate active power distribution networks. Specifically, this work presents a generalized process for translating sequential decision-making problems in power distribution systems into Markov decision process (MDP) formulations, illustrated through concrete grid service examples. Additionally, we introduce a simple environment design strategy to develop and evaluate example DRL algorithms for distribution system applications, complete with an included code repository to guide users through environment construction.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Locational Marginal Pricing (DLMP) for Congestion Management and Voltage Support

In this paper, a day-ahead market-clearing model for smart distribution systems is proposed. Various types of distributed energy resources (DERs), such as distributed energy storage, distributed generators, microgrids, and load aggregators, can bid into the day-ahead distribution-level electricity market. Considering system Volt/VAR control, network reconfiguration, and interactions with the wholesale market, an optimization model is built to clear the day-ahead market, through which the distribution locational marginal pricing (DLMPs) for both active power and reactive power are determined. Through derivations of the Lagrangian function and sensitivity factors, DLMPs are decomposed to five components (i.e., marginal costs for active power, reactive power, congestion, voltage support, and loss), which provide price signals to motivate DERs to contribute to congestion management and voltage support. Finally, case studies demonstrate the effectiveness of the proposed method.

congestion management↗

Roadmap Document for Pacific Northwest National Laboratory Contribution to the Open Modeling Framework

The Cooperative Research Network (CRN) of the National Rural Electric Cooperative Association (NRECA) has identified GridLAB-D as a tool that would provide significant benefit to its member utilities. However, they have also noted that the complexity of the tool would be a significant barrier for adoption. As can often happen in complex simulation environments, as the available capabilities and flexibility increases, the usability of the software decreases except for a few “power” users; this is not unique to GridLAB-D. While GridLAB-D has expanded to a considerable user base, with a few notable exceptions (e.g., American Electric Power) most users are focused on research and development. As a result, NRECA/CRN has proposed an Open Modeling Framework (OMF) designed to make the capabilities of GridLAB-D, and other advanced grid tools, available via a web interface. This will allow utility users to access many of the capabilities of GridLAB-D, with little to no knowledge of the tool itself. Other components will be layered over the simulation engines to provide the user with business support functions, allowing full business case scenarios to be created from the technical data generated within the simulations. Because of the open availability and potential national benefit of the OMF, PNNL has been tasked with supporting NRECA/CRN’s development of the tool, with a focus on incorporating GridLAB-D within the OMF structure and expanding GridLAB-D capabilities to support OMF functions. The GridLAB-D enhancements will be provided first to the OMF developers, but will also be delivered to the wider GridLAB-D community after validation via the community repository. This report is intended to provide a roadmap for the intended enhancements to be delivered by PNNL. Seven tasks were identified in cooperation with NRECA/CRN – each is briefly discussed, including potential outcomes and deadlines.

distribution↗

ATAC Process Proof of Concept (Final Report)

Researchers at INL with funding from the Department of Energy’s Office of Electricity Delivery and Energy Reliability (DOE-OE) evaluated a novel approach for near real-time consumption of threat intelligence. Demonstration testing in an industry environment supported the development of this new process to assist the electric sector in securing their critical networks. This report provides the reader with an understanding of the methods used during this proof of concept project. The processes and templates were further advanced with an industry partner during an onsite assessment. This report concludes with lessons learned and a roadmap for final development of these materials for use by industry.

99 GENERAL AND MISCELLANEOUS↗

Next-Generation Optimization under Uncertainty: Structure-Oriented Algorithms

With the advent of the smart grid, renewable technologies, and carbon emission programs, a key concern is the coordination of national infrastructures such as the electricity, natural gas, and water supply network systems. Anticipating and mitigating uncertainty of weather, demands, and contingencies in a more integrated environment is necessary to maximize resource efficiency and prevent cascading failures that can ultimately lead to catastrophic shortages of supplies. This project developed scalable algorithms for stochastic optimization capable of addressing extreme-scale problems (motivated by challenges in the design and operation of national infrastructures). Specifically, the project developed a new family of algorithms to solve continuous stochastic problems to local and global optimality as well as algorithms to solve mixed-integer convex and nonconvex stochastic programs. We developed supporting local and global convergence theory for these algorithms and implemented the algorithms in open-source software packages that can leverage high-performance computing architectures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Isolation contactor state control system

A controller area network (CAN) installed on a hybrid electric vehicle provides one node with control of high voltage power distribution system isolation contactors and the capacity to energize a secondary electro-mechanical relay device. The output of the secondary relay provides a redundant and persistent backup signal to the output of the node. The secondary relay is relatively immune to CAN message traffic interruptions and, as a result, the high voltage isolation contactor(s) are less likely to transition open in the event that the intelligent output driver should fail.

33 ADVANCED PROPULSION SYSTEMS↗

Low-observability matrix completion

An example device includes at least one processor configured to receive electrical parameter values corresponding to at least one first location within a power network. The at least one processor is further configured to determine, using matrix completion and based on the at least one electrical parameter value, an estimated value of at least one unknown electrical parameter. The at least one unknown electrical parameter corresponds to a second location within the power network. The at least one processor is also configured to cause at least one device within the power network to modify operation based on the estimated value of the at least one unknown electrical parameter.

Bernstein, Andrey↗

The reservoir network: A new network topology for district heating and cooling

Thermal district networks are effective solutions to substitute fossil fuels with renewable energy sources for heating and cooling. Moreover, thermal networking of buildings allows energy efficiency to be further increased. The waste heat from cooling can be reused for heating in thermal district systems. Because of bidirectional energy flows between prosumers, thermal networks require new hydraulic concepts. In this work, we present a novel network topology for simultaneous heating and cooling: the reservoir network. The reservoir network is robust in operation due to hydraulic decoupling of transfer stations, integrates heat sources and heat sinks at various temperature levels and is flexible in terms of network expansion. Furthermore, we used Modelica simulations to compare the new single-pipe reservoir network to a basecase double-pipe network, taking yearly demand profiles of different building types for heating and cooling. The electric energy consumed by the heat pumps and circulations pumps differs between the reservoir and base case networks by less than 1%. However, if the reservoir network is operated with constant instead of variable mass flow rate, the total electrical consumption can increase by 48% compared to the base case. As with any other network topology, the design and control of such networks is crucial to achieving energy efficient operation. Investment costs for piping and trenching depend on the district layout and dimensioning of the network. If a ring layout is applied in a district, the reservoir network with its single-pipe configuration is more economical than other topologies. For a linear layout, the piping costs are slightly higher for the reservoir network than for the base case because of larger pipe diameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reinforcement Learning for Distribution Grid Optimization (PyCIGAR) v0.1

PyCIGAR is a python software package that merges off-the-shelf reinforcement learning libraries (RLLib and Ray) with electric power distribution system simulation tools (OpenDSS and a custom power flow solver built by LBL). PyCIGAR enables the training of neural networks to optimize the behavior of different components in the electric distribution grid, such as control systems in photovoltaic rooftop solar inverters and electric battery storage systems. The software package has been used to train neural networks to update settings in photovoltaic rooftop solar inverter control systems to mitigate cyber attacks on other solar photovoltaic rooftop devices.

Arnold, Daniel↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗