Direct Writing of X-ray Gratings Using Zone-Plate-Array Lithography (ZPAL)

With the objective of providing the synchrotron and free-electron-laser communities with rapid turnaround and low prices for the highest quality and most advanced gratings and diffractive-focusing optics, LumArray has made specific improvements to its ZP-150 maskless photolithography system, which is based on Zone-Plate-Array Lithography (ZPAL), a technology unique to Lumarray. ZPAL’s advantages include an ability to correct in software for systematic patterning errors. Emphasis was placed on interferometric measurements of various contributors to patterning errors using Fizeau interferometry and a Mireau technique that was developed specifically for measuring errors within a micron-scale area. Average line-placement error was reduced below 20 nm using both pattern-file distortion and address-grid modification. The preferred implementation, address-grid modification, is hardware-based and requires no user intervention while also correcting more types of error. With continued iteration and refinement of the error measurements, we anticipate achieving global line-placement error below10nm. In order to investigate line-edge smoothness and high-frequency line-placement errors, a scheme for inspecting micron-sized areas was invented and implemented based on Mireau interferometry. This enabled the various contributions to be separately evaluated and measured. These included: exposure-dose variation, pattern-writing strategy and errors in the positioning of the microlenses. Deleterious crosstalk between microlenses was minimized via a pattern-dependent software modification. The impact of exposure threshold was revealed and adjustment made. The impact of address-grid fineness on line-edge roughness was likewise shown. Lastly, techniques were developed to measure and correct errors in the positioning of microlenses within the array. We expect final calibration of microlens positions to within 5nm.

42 ENGINEERING↗

WE-D-BRA-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Predicting Potentially Problematic VMAT Treatment Plans Before Patient Specific QA Measurements

Purpose: Several promising IMRT QA tools have been developed in recent years to combat problems found in the lack of sensitivity in planar dose measurements analyzed using consensus gamma analysis criteria. The increased complexity and added information with such devices adds not only increased time, but new challenges in determining endpoints for pass/fail criteria. Using a large cohort of previously measured planar IMRT QA data, it may be possible to correlate potentially problematic plans with calculated plan metrics that can be done a priori, such that these tools can be used only in clinically relevant situations. Methods: 90 previously measured, clinically delivered VMAT plans were exported in DICOM RT format. Using a Matlab program, plan metrics were computed based on a previously developed set of equations (Du et al. 2014). These metrics included MU-weighted beam irregularity, which quantifies an MLC shape’s deviation from that of a circle. Machine delivery parameters such as MU delivered per degree and leaf movement in millimeters per MU were also calculated. Based on a previous analysis of 394 IMRT QA measurements, a “failing” plan was defined as one with less than 85% gamma pass rate when computed at 1% dose difference and 2 mm distance to agreement; 16 of the 90 plans were identified as failing Results: A ROC curve was generated with an AUC of 0.9409. All 16 outliers were detected with a specificity of 85.1% when using a threshold value based on a linear combination of the MU-weighted plan irregularity and the leaf speed in mm/degree (average MU delivered per degree multiplied by average leaf movement in mm per MU). Conclusion: This data supports that potentially problematic VMAT plans can possibly be predicted before measurement by assessing the MU-weighted irregularity of the MLC shapes combined with the averaged leaf speed of the MLC.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-06: Improving the Performance of Gamma Analysis QA with Radiomics- Based Image Analysis

Purpose: The use of gamma analysis for IMRT quality assurance has well-known limitations. Traditionally, a simple thresholding technique is used to evaluated passing criteria. However, like any image the gamma distribution is rich in information which thresholding mostly discards. We therefore propose a novel method of analyzing gamma images that uses quantitative image features borrowed from radiomics, with the goal of improving error detection. Methods: 368 gamma images were generated from 184 clinical IMRT beams. For each beam the dose to a phantom was measured with EPID dosimetry and compared to the TPS dose calculated with and without normally distributed (2mm sigma) errors in MLC positions. The magnitude of 17 intensity histogram and size-zone radiomic features were derived from each image. The features that differed most significantly between image sets were determined with ROC analysis. A linear machine-learning model was trained on these features to classify images as with or without errors on 180 gamma images.The model was then applied to an independent validation set of 188 additional gamma distributions, half with and half without errors. Results: The most significant features for detecting errors were histogram kurtosis (p=0.007) and three size-zone metrics (p<1e-6 for each). The sizezone metrics detected clusters of high gamma-value pixels under mispositioned MLCs. The model applied to the validation set had an AUC of 0.8, compared to 0.56 for traditional gamma analysis with the decision threshold restricted to 98% or less. Conclusion: A radiomics-based image analysis method was developed that is more effective in detecting error than traditional gamma analysis. Though the pilot study here considers only MLC position errors, radiomics-based methods for other error types are being developed, which may provide better error detection and useful information on the source of detected errors. This work was partially supported by a grant from the Agency for Healthcare Research and Quality, grant number R18 HS022244-01.

60 APPLIED LIFE SCIENCES↗

Measurements of the radiation dose to LDEF by means of passive dosimetry

A very simple experiment was fielded on LDEF to measure the energetic radiation dose by means of passive dosimetry. It consisted of two identical packets of 16 LiF thermoluminescent dosimeters (TLD) arranged in planar arrays. One array was placed on the leading edge of the spacecraft, the other on the trailing edge. These arrays were installed in opaque packets of 1 mil Al foil and Kapton tape mounted behind an Al plate of 30 mils thickness. The nominal energy thresholds were 14 MeV for protons and 650 keV for electrons. In addition to the flight arrays, two control arrays were prepared which were kept with the flight arrays as long as possible during experimental integration and then stored in the lab. The flight and control arrays were read out alternating in groups of four; it was found that the control dose was negligible. The flight and control detectors were exposed to a 55 MeV proton beam in order to provide a recalibration of the detectors. It was found that the post-flight and pre-flight calibrations were in good agreement. A comparison of results with the prediction shows that the measured dose was a factor of 4 to 5 low. It is possible that there was in-flight annealing of the TLDs as a result of the long mission and perhaps temperature excursions of the sensors. The East-West effect was larger than expected. The ratio of 1.65 is approximately what was expected for the protons alone. Electrons should reduce the dose ratio since electrons add equally to the leading and trailing edge dose. A possible explanation is that the electron dose was negligible compared to the proton dose.

Blake, J. B.↗

Tailoring automatic exposure control toward constant detectability in digital mammography

Purpose: The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. Methods: The default “OPDOSE” AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d′), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (T{sub t}) in the European guidelines for the 0.1 mm diameter disc (i.e., T{sub t} ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (T{sub t}), calculated detectability (d′), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. Results: The default OPDOSE AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d′ 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d′), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default AEC mode in the homogeneous background increased by 62% in going from 20 to 70 mm PMMA thickness; in the structured background, the increase was 39%. Implementation of the modified mode entailed an increase in mAs at PMMA thicknesses >40 mm; the modified AEC held threshold gold thickness constant above 40 mm PMMA with a maximum deviation of 5% in the homogeneous background and 3% in structured background. SDNR was also held constant with a maximum deviation of 4% and 2% for the homogeneous and the structured background, respectively. These results were obtained with an increase of MGD between 15% and 73% going from 40 to 70 mm PMMA thickness. Conclusions: This work has proposed and implemented a modified AEC mode, tailored toward constant detectability at larger breast thickness, i.e., above 40 mm PMMA equivalent. The desired improvement in object detectability could be obtained while maintaining MGD within the European guidelines achievable dose limit. (A study designed to verify the performance of the modified mode using more clinically realistic data is currently underway.)

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-01: Abdominal Synthetic CT Generation in Support of Liver SBRT Dose Calculation

Purpose: To demonstrate and validate a technique for generating MRI-derived synthetic CT volumes (MRCTs) in support of adaptive liver SBRT. Methods: Under IRB approval, ten hepatocellular carcinoma patients were scanned using a single MR sequence (T1 Dixon-VIBE), yielding inherently-registered water, fat, and T1-weighted images. Air-containing voxels were identified by intensity thresholding. The envelope of the anterior vertebral bodies was segmented from the fat image by fitting a shape model to vertebral body candidate voxels, then using level sets to expand the contour outward. Fuzzy-C-Means (FCM) was then used to classify each non-air voxel in the image as fat, water, bone, or marrow. Bone and marrow only were classified within the vertebral body envelope. The MRCT was created by integrating the product of the FCM class probability with the assigned class density for each voxel. The resulting MRCTs were deformably aligned with planning CTs and 2-ARC SBRT VMAT plans were optimized on the MRCT density maps. Fluence was copied onto the CT density grids and dose recalculated. Results: The MRCTs faithfully reproduced most of the features visible in the corresponding CT image volumes, with exceptions of ribs and posterior spinous processes. The liver, vertebral bodies, kidneys, spleen and cord all had median HU differences of less than 75 between MRCT and CT images. PTV D99% values had an average 0.2% difference (standard deviation: 0.46%) between calculations on MRCT and CT density grids. The maximum difference in dose to 0.1cc of the PTV was 0.25% (std:0.49%). OAR dose differences were similarly small (mean:0.03Gy, std:0.26Gy). The largest normal tissue complication percentage (NTCP) difference was 1.48% (mean:0.06%, std:0.54%). Conclusions: MRCTs from a single abdominal imaging sequence are promising for use in SBRT dose calculation. Future work will focus on extending models to better define bones in the upper abdomen. Supported by NIHR01EB016079 and NIH1L30CA199594-01.

60 APPLIED LIFE SCIENCES↗

Functional Evaluation of the DOZA DKG-05D Electronic Dosimeter System

The DOZA DKG-05D electronic personal dosimeter (EPD) was the subject of a limited type-test evaluation in support of Plutonium Production Reactor Agreement (PPRA) Implementation. The primary goal of this evaluation was to provide confidence in the functionality of the dosimeter and identify potential weaknesses in PPRA applications. The tests were based on IEC-61526, recommendations of the International Electrotechnical Commission pertaining to EPDs. All tests were performed in Pacific Northwest National Laboratory’s (PNNL) Radiological Calibrations and Standards Facility in the 318 building. The first testing category was functional considerations. The tests found that the mechanical characteristics of the DKG-05D support usability. However, user controls are not intuitive and straightforward, and the user instructions were unclear and difficult to follow. The unit functioned in a variety of humidity conditions. In high temperature conditions it performed well. However, in cold conditions the display began to fade, which limits its usefulness below about 5 °C. The vendor claims that the unit functions to -20 °C, and it may be correctly recording doses at that low temperature, but the doses cannot be read in real time. Testing found that battery life is generally good, operating for 200 hours on a full charge. This is far more than needed for the intended application. Charging the battery, however, had some pitfalls resulting from two charging modes. The high-current mode would be automatically selected if the battery charge fell below a threshold value when inserted in the charger. Otherwise, a low-current mode would be selected. In some cases a battery needing recharging would not get sufficient current to fully charge in a reasonable time period. There were also problems found in the low-battery indication and there was a possibility for data loss in the low-battery condition. The EPD generally performed well in measuring dose and dose rate. There were some small problems with non-linearity over a range of doses, but these non-linearities were at extremely low and very high doses and would not adversely affect the performance in our intended application. The testing resulted in the general conclusion that the DOZA DKG-05D is suitable for use in PPRA applications for real-time indication of dose received by a user and for estimation of stay times in radiation zones. It can be used as a supplement to a passive dosimeter, but it should not be used for measuring the user’s dose of record.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MO-F-CAMPUS-T-05: Correct Or Not to Correct for Rotational Patient Set-Up Errors in Stereotactic Radiosurgery

Purpose: To quantify the effect of patient rotation in stereotactic radiation therapy and establish a threshold where rotational patient set-up errors have a significant impact on target coverage. Methods: To simulate rotational patient set-up errors, a Matlab code was created to rotate the patient dose distribution around the treatment isocentre, located centrally in the lesion, while keeping the structure contours in the original locations on the CT and MRI. Rotations of 1°, 3°, and 5° for each of the pitch, roll, and yaw, as well as simultaneous rotations of 1°, 3°, and 5° around all three axes were applied to two types of brain lesions: brain metastasis and acoustic neuroma. In order to analyze multiple tumour shapes, these plans included small spherical (metastasis), elliptical (acoustic neuroma), and large irregular (metastasis) tumour structures. Dose-volume histograms and planning target volumes were compared between the planned patient positions and those with simulated rotational set-up errors. The RTOG conformity index for patient rotation was also investigated. Results: Examining the tumour volumes that received 80% of the prescription dose in the planned and rotated patient positions showed decreases in prescription dose coverage of up to 2.3%. Conformity indices for treatments with simulated rotational errors showed decreases of up to 3% compared to the original plan. For irregular lesions, degradation of 1% of the target coverage can be seen for rotations as low as 3°. Conclusions: This data shows that for elliptical or spherical targets, rotational patient set-up errors less than 3° around any or all axes do not have a significant impact on the dose delivered to the target volume or the conformity index of the plan. However the same rotational errors would have an impact on plans for irregular tumours.

60 APPLIED LIFE SCIENCES↗

Review of Landscaping Equipment Vibration Risk Exposure, LLNL Site 200 (Various Locations), Whole Body Vibration Seated and Standing Mowers

WBV (Whole-Body Vibration) for operators of seated and standing lawn mowers was conducted during landscape activities from April 2019 through August 2019 at various locations around LLNL Site 200. Mowing is generally performed by each landscaper for 2-3 days every other week with a maximum duration of 3-5 hours each day. On mowing days, other tasks are performed for the remainder of the day that do not expose the worker to WBV such as irrigation, blowing, or sweeping. The mowing terrain at LLNL is variable with typical reported conditions such as gopher holes, exposed tree roots, quick turns, normal and high growth, weeds, and mushy/wet ground that can result in jolts to the mower operator. The Larson Davis HVM200 seat pad with tri-axial accelerometer was used for monitoring workers. For the seated mowers, the HVM200 seat pad with tri-axial accelerometer was placed on the seat between the user and seat pan of the mower. For standing mowers, the seat pad with tri-axial accelerometer was wrapped with Dycem (for seat pad protection) and placed directly on top of the mower deck and underneath the end-user’s right foot. Monitoring for WBV was conducted while operators used different types, makes, and models of mowers. A total of sixteen samples were collected from the operators of seated mower and 6 samples were collected from operators of standing mower. This initial data sampling was part of a discovery phase to identify if WBV exposure met the 2016 ACGIH TLVs (Threshold Limit Values). This initial data identified that workers operating the mowers do not exceed either the TLV or Action Level (AL) for Weighted Acceleration Levels (A(8)) but typically exceed the Vibration Dose Value (VDV) lower boundary for the standing mowers.

59 BASIC BIOLOGICAL SCIENCES↗

Test GammaPix™ Radiation Detection Software with Smartphones

GammaPix™ is a smartphone application that uses smartphone cameras to detect ionizing radiation. Brookhaven National Laboratory (BNL) evaluated the performance of the software in detecting radioactive materials. For this purpose, a series of tests were conducted at the Radiation Calibration Facility Annex at BNL. The experiments included dose measurements with three types of NIST-traceable calibration sources, 60Co, 241Am, and 137Cs. The recorded results by GammaPix™ were compared with the values measured by calibrated dosimeters to determine the detection thresholds. Several selected models of iPhones and Android cell phones with different pixel sizes and resolution were tested. In this paper, we present the test procedures and discuss the test results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total-Ionizing-Dose Effects and Low-Frequency Noise in 16-nm InGaAs FinFETs With HfO 2 /Al 2 O 3 Dielectrics

Here, total-ionizing-dose mechanisms are investigated in 16-nm InGaAs FinFETs with an HfO 2 /Al 2 O 3 gate-stack. Transistors are irradiated up to 500 krad(SiO 2 ) and annealed at high temperatures. Irradiated devices show negative threshold-voltage V th shifts, subthreshold stretch-out, and leakage current increases. These result from positive charge trapping in the gate oxide and shallow trench insulators, and increases in the interface and border-trap charge densities. Low-frequency noise measurements at different temperatures indicate a significant increase of noise magnitude in irradiated devices at an activation energy of ~0.4 eV. Density functional theory (DFT) calculations strongly suggest that transistor V th shifts are due primarily to hole trapping at oxygen vacancies in HfO 2 , and the increased noise is due primarily to O vacancies in Al 2 O 3 . Additional contributions to the noise from defects in the GaAs buffer layer are also likely, primarily at low temperatures.

total dose effects↗

Cascaded systems analysis of photon counting detectors

Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.

60 APPLIED LIFE SCIENCES↗

Establishing Cost-Effective Allocation of Proton Therapy for Breast Irradiation

Purpose: Cardiac toxicity due to conventional breast radiation therapy (RT) has been extensively reported, and it affects both the life expectancy and quality of life of affected women. Given the favorable oncologic outcomes in most women irradiated for breast cancer, it is increasingly paramount to minimize treatment side effects and improve survivorship for these patients. Proton RT offers promise in limiting heart dose, but the modality is costly and access is limited. Using cost-effectiveness analysis, we provide a decision-making tool to help determine which breast cancer patients may benefit from proton RT referral. Methods and Materials: A Markov cohort model was constructed to compare the cost-effectiveness of proton versus photon RT for breast cancer management. The model was analyzed for different strata of women based on age (40 years, 50 years, and 60 years) and the presence or lack of cardiac risk factors (CRFs). Model entrants could have 1 of 3 health states: healthy, alive with coronary heart disease (CHD), or dead. Base-case analysis assumed CHD was managed medically. No difference in tumor control was assumed between arms. Probabilistic sensitivity analysis was performed to test model robustness and the influence of including catheterization as a downstream possibility within the health state of CHD. Results: Proton RT was not cost-effective in women without CRFs or a mean heart dose (MHD) <5 Gy. Base-case analysis noted cost-effectiveness for proton RT in women with ≥1 CRF at an approximate minimum MHD of 6 Gy with a willingness-to-pay threshold of $100,000/quality-adjusted life-year. For women with ≥1 CRF, probabilistic sensitivity analysis noted the preference of proton RT for an MHD ≥5 Gy with a similar willingness-to-pay threshold. Conclusions: Despite the cost of treatment, scenarios do exist whereby proton therapy is cost-effective. Referral for proton therapy may be cost-effective for patients with ≥1 CRF in cases for which photon plans are unable to achieve an MHD <5 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-14: A Comparative Study Between Forward and Inverse Planning in Gamma Knife Radiosurgery for Acoustic Neuroma Tumours

Purpose: To evaluate forward and inverse planning methods for acoustic neuroma cases treated in Gamma Knife Perfexion. Methods: Five patients with acoustic neuroma tumour abutting brainstem were planned twice in LGP TPS (Version 10.1) using TMR10 algorithm. First plan was entirely based on forward planning (FP) in which each shot was chosen manually. Second plan was generated using inverse planning (IP) for which planning parameters like coverage, selectivity, gradient index (GI) and beam-on time threshold were set. Number of shots in IP was automatically selected by objective function using iterative process. In both planning methods MRI MPRAGE sequence images were used for tumour localization and planning. A planning dose of 12Gy at 50% isodose level was chosen. Results and Discussion: Number of shots used in FP was greater than IP and beam-on time in FP was in average 1.4 times more than IP. One advantage of FP was that the brainstem volume subjected to 6Gy dose (25% isodose) was less in FP than IP. Our results showed use of more number of shots as in FP results in GI less than or equal to 2.55 which is close to its lower limit. Dose homogeneity index (DHI) analysis of FP and IP showed average values of 0.59 and 0.67 respectively. General trend in GK for planning in acoustic neuroma cases is to use small collimator shots to avoid dose to adjacent critical structures. More number of shots and prolonged treatment time causes inconvenience to the patients. Similarly overuse of automatic shot shaping as in IP results in increased scatter dose. A compromise is required in shot selection for these cases. Conclusion: IP method could be used in acoustic neuroma cases to decrease treatment time provided the source sector openings near brainstem are shielded or adjusted appropriately to reduce brainstem dose.

60 APPLIED LIFE SCIENCES↗

SU-C-204-01: A Dosimetric Investigation Into the Effects of Yttrium-90 Radioembolization On the GI Tract: In-Vivo and Histological Analysis in An Animal Model

Purpose: In Yttrium-90 (90Y) radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in ulceration, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed-dose endpoints. Methods: Under approval of the University of Tennessee IACUC, 6 female pigs were included in this study. Animals underwent transfemoral angiography and infusion of calibrated dosages of 90Y resin microspheres into arteries supplying part of the gastric wall. A 99mTc-MAA simulation study was performed first to determine perfused tissue volume for treatment planning along with contrast-enhanced CT. The pigs were monitored for side effects for 9 weeks, after which time they were euthanized and their upper gastrointestinal tracts were harvested for analysis. Results: 90Y radioembolization was infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1–2 small (<3.0 cm2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastric wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microsphere deposition patterns confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a reasonable estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa may contribute to decreased toxicity of 90Y radioembolization compared to external-beam radiation therapy in gastrointestinal tissue. This project was supported by SIRTex Medical Ltd.

60 APPLIED LIFE SCIENCES↗

Effects of neutron irradiation on the characteristics of a buried channel CCD at 80 degrees Kelvin and 295 degrees Kelvin

Buried channel CCD shift registers were irradiated with 15 MeV neutrons. The irradiations were performed at 80 K and 295 K on operating devices with normal clocks and bias voltages applied. Dark current increased from the pre-irradiation value of 7 nA/sq cm to 1,600 nA/sq cm at 1 x 10 to the 13th power n/sq cm. The input gate threshold shift observed at 80K was minus 0.9 volts per 10 to the 13th power n/sq cm, a factor of 4 less than that predicted from a first order calculation of the equivalent ionization dose of neutrons in the oxide. Transfer efficiency measurements yielded a bulk electron trap creation rate for neutron irradiation of 14.0 cm to the minus 1 power at 295 K with a trap emission time constant of 25 microseconds.

Saks, N. S.↗

GaAs/GaAlAs distributed Bragg reflector laser with a focused ion beam, low dose dopant implanted grating

The performance of a GaAs/GaAlAs distributed Bragg reflector (DBR) laser using a focused ion beam implanted grating (FIB-DBR) is reported for the first time. Stripes of Si(2+) with a period of 2300 A and a dose about 10 to the 14th/sq cm are directly implanted into the passive large optical cavity layer to provide the distributed feedback. Surface-emitting light from the second-order grating is observed. Threshold current of 110 mA and single DBR mode operation from 20 to 40 C are obtained. The wavelength tuning rate with temperature is 0.8 A/C. The coupling coefficient is estimated to be 15/cm. The results show that FIB technology is practical for distributed feedback and DBR lasers and optoelectronic integrated circuits.

Wu, M. C.↗

Irradiated Volume as a Predictor of Brain Radionecrosis After Linear Accelerator Stereotactic Radiosurgery

Purpose: To investigate the correlation between volume of brain irradiated by stereotactic radiosurgery (SRS) and the incidence of symptomatic and asymptomatic brain radionecrosis (RN). Methods and Materials: A retrospective analysis was performed of patients treated with single-fraction SRS for brain metastases at our institution. Patients with at least 6-month imaging follow-up were included and diagnosed with RN according to a combination of criteria, including appearance on serial imaging and histology. Univariate and multivariate analyses were performed to determine the predictive value of multiple variables, including volume of brain receiving a specific dose (V8 Gy-V18 Gy). Results: Sixty-three patients were reviewed, with a total of 173 lesions. Most patients (63%) had received previous whole-brain irradiation. Mean prescribed SRS dose was 18 Gy. Symptomatic RN was observed in 10% and asymptomatic RN in 4% of lesions treated. Multivariate regression analysis showed V8 Gy-V16 Gy to be most predictive of symptomatic RN (p < 0.0001). Threshold volumes for significant rise in RN rates occurred between the 75th and 90th percentiles, with a midpoint volume of 10.45 cm{sup 3} for V10 Gy and 7.85 cm{sup 3} for V12 Gy. Conclusions: Analysis of patient and treatment variables revealed V8 Gy-V16 Gy to be the best predictors for RN using linear accelerator-based single-fraction SRS for brain metastases. We propose that patients with V10 Gy >10.5 cm{sup 3} or V12 Gy >7.9 cm{sup 3} be considered for hypofractionated rather than single-fraction treatment, to minimize the risk of symptomatic RN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗