Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Design Visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Visualizing Hierarchical Performance Profiles of Parallel Codes Using CallFlow

Calling context trees (CCTs) couple performance metrics with call paths, helping understand the execution and performance of parallel programs. To identify performance bottlenecks, programmers and performance analysts visually explore CCTs to form and validate hypotheses regarding degraded performance. However, due to the complexity of parallel programs, existing visual representations do not scale to applications running on a large number of processors. In this work, we present CallFlow, an interactive visual analysis tool that provides a high-level overview of CCTs together with semantic refinement operations to progressively explore CCTs. Using a flow-based metaphor, we visualize a CCT by treating execution time as a resource spent during the call chain, and demonstrate the effectiveness of our design with case studies on large-scale, production simulation codes.

97 MATHEMATICS AND COMPUTING↗

Visualizing temperature-dependent phase stability in high entropy alloys

High entropy alloys (HEAs) contain near equimolar amounts of five or more elements and are a compelling space for materials design. In the design of HEAs, great emphasis is placed on identifying thermodynamic conditions for single-phase and multi-phase stability regions, but this process is hindered by the difficulty of navigating stability relationships in high-component spaces. Traditional phase diagrams use barycentric coordinates to represent composition axes, which require ( N – 1) spatial dimensions to represent an N -component system, meaning that HEA systems with N > 4 components cannot be readily visualized. Here, we propose forgoing barycentric composition axes in favor of two energy axes: a formation-energy axis and a ‘reaction energy’ axis. These Inverse Hull Webs offer an information-dense 2D representation that successfully captures complex phase stability relationships in N ≥ 5 component systems. We use our proposed diagrams to visualize the transition of HEA solid-solutions from high-temperature stability to metastability upon quenching, and identify important thermodynamic features that are correlated with the persistence or decomposition of metastable HEAs.

Chemistry↗

Materials informatics: From the atomic-level to the continuum

We report that in recent years materials informatics, which is the application of data science to problems in materials science and engineering, has emerged as a powerful tool for materials discovery and design. This relatively new field is already having a significant impact on the interpretation of data for a variety of materials systems, including those used in thermoelectrics, ferroelectrics, battery anodes and cathodes, hydrogen storage materials, polymer dielectrics, etc. Its practitioners employ the methods of multivariate statistics and machine learning in conjunction with standard computational tools (e.g., density-functional theory) to, for example, visualize and dimensionally reduce large data sets, identify patterns in hyperspectral data, parse microstructural images of polycrystals, characterize vortex structures in ferroelectrics, design batteries and, in general, establish correlations to extract important physics and infer structure-property-processing relationships. In this Overview, we critically examine the role of informatics in several important materials subfields, highlighting significant contributions to date and identifying known shortcomings. We specifically focus attention on the difference between the correlative approach of classical data science and the causative approach of physical sciences. From this perspective, we also outline some potential opportunities and challenges for informatics in the materials realm in this era of big data.

36 MATERIALS SCIENCE↗

Multimodal parameter spaces of a complex multi-channel neuron model

One of the most common types of models that helps us to understand neuron behavior is based on the Hodgkin–Huxley ion channel formulation (HH model). A major challenge with inferring parameters in HH models is non-uniqueness: many different sets of ion channel parameter values produce similar outputs for the same input stimulus. Such phenomena result in an objective function that exhibits multiple modes (i.e., multiple local minima). This non-uniqueness of local optimality poses challenges for parameter estimation with many algorithmic optimization techniques. HH models additionally have severe non-linearities resulting in further challenges for inferring parameters in an algorithmic fashion. To address these challenges with a tractable method in high-dimensional parameter spaces, we propose using a particular Markov chain Monte Carlo (MCMC) algorithm, which has the advantage of inferring parameters in a Bayesian framework. The Bayesian approach is designed to be suitable for multimodal solutions to inverse problems. We introduce and demonstrate the method using a three-channel HH model. We then focus on the inference of nine parameters in an eight-channel HH model, which we analyze in detail. We explore how the MCMC algorithm can uncover complex relationships between inferred parameters using five injected current levels. The MCMC method provides as a result a nine-dimensional posterior distribution, which we analyze visually with solution maps or landscapes of the possible parameter sets. The visualized solution maps show new complex structures of the multimodal posteriors, and they allow for selection of locally and globally optimal value sets, and they visually expose parameter sensitivities and regions of higher model robustness. We envision these solution maps as enabling experimentalists to improve the design of future experiments, increase scientific productivity and improve on model structure and ideation when the MCMC algorithm is applied to experimental data.

97 MATHEMATICS AND COMPUTING↗

Lightfall v0.0.1

Lightfall is a desktop application for synchrotron beamline instrument control, data acquisition, and live analysis at the Advanced Light Source (ALS). Built on Python and Qt, it provides a native graphical interface for operating beamline hardware, configuring and executing experimental scans, and visualizing results in real time. Key features include direct integration with EPICS control systems, a built-in electronic logbook, remote beamline access over secure tunnels, and an interprocess communication (IPC) architecture that coordinates with external analysis applications via ZMQ and EPICS process variables. This IPC approach allows Lightfall to orchestrate specialized analysis tools—including GPU-accelerated streaming correlators—without embedding them, avoiding the dependency conflicts common in monolithic scientific software platforms. Compared to prior approaches such as Xi-CAM's plugin-based architecture, Lightfall's design cleanly separates instrument control from domain-specific analysis, enabling feedback-driven acquisition where live analysis results can adjust scan parameters during an experiment. Its native Qt interface provides responsive performance for real-time data visualization that web-based alternatives struggle to match. Lightfall is designed for use by beamline scientists and staff operating synchrotron instruments at national user facilities.

Pandolfi, Ronald [Lawrence Berkeley National Labor↗

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

Evaluation of Visual Analytics Environments: The Road to the Visual Analytics Science and Technology Challenge Evaluation Methodology

The evaluation of visual analytics environments was a topic in Illuminating the Path [Thomas 2005] as a critical aspect of moving research into practice. For a thorough understanding of the utility of the systems available, evaluation not only involves assessing the visualizations, interactions or data processing algorithms themselves, but also the complex processes that a tool is meant to support (such as exploratory data analysis and reasoning, communication through visualization, or collaborative data analysis [Lam 2012; Carpendale 2007]). Researchers and practitioners in the field have long identified many of the challenges faced when planning, conducting, and executing an evaluation of a visualization tool or system [Plaisant 2004]. Evaluation is needed to verify that algorithms and software systems work correctly and that they represent improvements over the current infrastructure. Additionally to effectively transfer new software into a working environment, it is necessary to ensure that the software has utility for the end-users and that the software can be incorporated into the end-user’s infrastructure and work practices. Evaluation test beds require datasets, tasks, metrics and evaluation methodologies. As noted in [Thomas 2005] it is difficult and expensive for any one researcher to setup an evaluation test bed so in many cases evaluation is setup for communities of researchers or for various research projects or programs. Examples of successful community evaluations can be found [Chinchor 1993; Voorhees 2007; FRGC 2012]. As visual analytics environments are intended to facilitate the work of human analysts, one aspect of evaluation needs to focus on the utility of the software to the end-user. This requires representative users, representative tasks, and metrics that measure the utility to the end-user. This is even more difficult as now one aspect of the test methodology is access to representative end-users to participate in the evaluation. In many cases the sensitive nature of data and tasks and difficult access to busy analysts puts even more of a burden on researchers to complete this type of evaluation. User-centered design goes beyond evaluation and starts with the user [Beyer 1997, Shneiderman 2009]. Having some knowledge of the type of data, tasks, and work practices helps researchers and developers know the correct paths to pursue in their work. When access to the end-users is problematic at best and impossible at worst, user-centered design becomes difficult. Researchers are unlikely to go to work on the type of problems faced by inaccessible users. Commercial vendors have difficulties evaluating and improving their products when they cannot observe real users working with their products. In well-established fields such as web site design or office software design, user-interface guidelines have been developed based on the results of empirical studies or the experience of experts. Guidelines can speed up the design process and replace some of the need for observation of actual users [heuristics review references]. In 2006 when the visual analytics community was initially getting organized, no such guidelines existed. Therefore, we were faced with the problem of developing an evaluation framework for the field of visual analytics that would provide representative situations and datasets, representative tasks and utility metrics, and finally a test methodology which would include a surrogate for representative users, increase interest in conducting research in the field, and provide sufficient feedback to the researchers so that they could improve their systems.

evaluation↗

Smart Mobility in the Cloud: Enabling Real-Time Situational Awareness and Cyber-Physical Control Through a Digital Twin for Traffic

This article presents the design, implementation, and use cases of the Chattanooga Digital Twin (CTwin) towards the vision for next-generation smart city applications for urban mobility management. CTwin is an end-to-end web-based platform that incorporates various aspects of the decision-making process for optimizing urban transportation systems in Chattanooga, Tennessee, to reduce traffic congestion, incidents, and vehicle fuel consumption. The platform serves as a cyberinfrastructure to collect and integrate multi-domain urban mobility data from various online repositories and Internet of Things (IoT) sensors, covering multiple urban aspects (e.g., traffic, natural hazards, weather, and safety) that are relevant to urban mobility management. The platform enables advanced capabilities for: (a) real-time situational awareness on traffic and infrastructure conditions on highways and urban roads, (b) cyber-physical control for optimizing traffic signal timing, and (c) interactive visual analytics on big urban mobility data and various metrics for traffic prediction and transportation performance evaluation. The platform is designed using a multi-level componentization paradigm and is implemented using modular and adaptive architecture, rendering it as a generalizable and extendable prototype for other urban management applications. We present several use cases to demonstrate CTwin's core capabilities for supporting decision-making in smart urban mobility management.

33 ADVANCED PROPULSION SYSTEMS↗

Assessing Mechanical Behaviors of Additive Manufactured Alternating Layers of Inconel-718/H13 Tool Steel

An H 13 (high-strength, low-ductility) tool steel die will fail due to compressive high cycle fatigue. If the die is manufactured by direct metal deposition and layered with Inconel-718 (low-strength, high-ductility), it may impact the mechanical properties of the material. Hardness tests, micro-tensile tests, and micro-compression tests were used to analyze the mechanical properties of this additive manufactured layered metal while observing real-time morphology changes on the surface. Energy dispersive spectroscopy was also performed to determine where failure tended to occur within the Inconel-718 material. The hardness was lower than expected, as was the ultimate tensile strength, yield strength, modulus of elasticity, and strain at failure. Each tensile test failed within the Inconel-718 layer. In conclusion, a sample designed to have a single thin middle layer of Inconel-718 sandwiched by H 13 enabled the visual recording of crack initiation and propagation under a tensile load using a confocal scanning laser microscope.

36 MATERIALS SCIENCE↗

Measured daylighting potential of a static optical louver system under real sun and sky conditions

Side-by-side comparisons were made over solstice-to-solstice changes in sun and sky conditions between an optical louver system (OLS) and a conventional Venetian blind set at a horizontal slat angle and located inboard of a south-facing, small-area, clerestory window in a full-scale office testbed. Daylight autonomy (DA), window luminance, and ceiling luminance uniformity were used to assess performance. The performance of both systems was found to have significant seasonal variation, where performance under clear sky conditions improved as maximum solar altitude angles transitioned from solstice to equinox. Although the OLS produced fewer hours per day of DA on average than the Venetian blind, the OLS never exceeded the designated 2000 cd/m2 threshold for window glare. In contrast, the Venetian blind was found to exceed the visual discomfort threshold over a large fraction of the day during equinox conditions. Notably, these peak periods of visual discomfort occurred during the best periods of daylighting performance. Luminance uniformity was analyzed using calibrated high dynamic range luminance images. Under clear sky conditions, the OLS was found to increase the luminance of the ceiling as well as produce a more uniform distribution. Furthermore, compared to conventional venetian blinds, the static optical sunlight redirecting system studied has the potential to significantly reduce the annual electrical lighting energy demand of a daylit space and improve the quality from the perspective of building occupants by consistently transmitting useful daylight while eliminating window glare.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

VIBES: a workflow for annotating and visualizing viral sequences integrated into bacterial genomes

Abstract Bacteriophages are viruses that infect bacteria. Many bacteriophages integrate their genomes into the bacterial chromosome and become prophages. Prophages may substantially burden or benefit host bacteria fitness, acting in some cases as parasites and in others as mutualists. Some prophages have been demonstrated to increase host virulence. The increasing ease of bacterial genome sequencing provides an opportunity to deeply explore prophage prevalence and insertion sites. Here we present VIBES (Viral Integrations in Bacterial genomES), a workflow intended to automate prophage annotation in complete bacterial genome sequences. VIBES provides additional context to prophage annotations by annotating bacterial genes and viral proteins in user-provided bacterial and viral genomes. The VIBES pipeline is implemented as a Nextflow-driven workflow, providing a simple, unified interface for execution on local, cluster and cloud computing environments. For each step of the pipeline, a container including all necessary software dependencies is provided. VIBES produces results in simple tab-separated format and generates intuitive and interactive visualizations for data exploration. Despite VIBES’s primary emphasis on prophage annotation, its generic alignment-based design allows it to be deployed as a general-purpose sequence similarity search manager. We demonstrate the utility of the VIBES prophage annotation workflow by searching for 178 Pf phage genomes across 1072 Pseudomonas spp. genomes.

59 BASIC BIOLOGICAL SCIENCES↗

An efficient virus–induced gene silencing (VIGS) system for gene functional studies in Miscanthus

Virus-induced gene silencing (VIGS) is a powerful tool for transient gene functional analysis in plants, especially for monocot species (e.g., grasses) that are recalcitrant to transformation. Despite various VIGS systems that have been developed in different plant species, none was previously available for the bioenergy crop Miscanthus. Here, we report the establishment of an efficient and robust VIGS system mediated by Tobacco Rattle Virus (TRV) in Miscanthus. We first investigated the impact of various factors that may affect gene silencing efficiency using the Miscanthus sinensis Phytoene Desaturase (MsPDS) gene as a visual indicator of photobleaching. Then, we optimized the TRV-elicited VIGS procedure using an orthogonal experimental design with four factors (sprout size, Agrobacterium concentration, vacuum infiltration time, and co-incubation time) each at three levels. The following led to the highest silencing efficiency (~76%): inoculation of germinating seedlings (1.0–2.0 mm), Agrobacterium tumefaciens culture grown to optical density at 600 nm (OD 600 ) of 0.4, vacuum infiltration for 90 min, and co-incubation for 5 h. The VIGS system established was applicable for both M. sinensis and M. lutarioriparius, with comparable gene silencing efficiency. We verified the efficacy of the VIGS system via the functional characterization of the role of a MYB transcription factor, MsMYB112, in salt stress tolerance. Expression of MsMYB112 was successfully knocked down using the VIGS system, and this led to compromised salt tolerance in the silenced Miscanthus plants. The TRV-based VIGS system established may, therefore, substantially facilitate functional genomic studies in Miscanthus.

60 APPLIED LIFE SCIENCES↗

A clinically observed discrepancy between image-based and log-based MLC positions

Purpose: To present a clinical case in which real-time intratreatment imaging identified an multileaf collimator (MLC) leaf to be consistently deviating from its programmed and logged position by >1 mm. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used to capture cine during treatment images. The author serendipitously visually identified a suspected MLC leaf displacement that was not otherwise detected. The leaf position as recorded on the EPID images was measured and log-files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log-file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3 ± 0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusions: It has been clinically observed that log-file derived leaf positions can differ from their actual position by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trust log-file records. Intratreatment EPID imaging provides a method to capture departures from MLC planned positions.

60 APPLIED LIFE SCIENCES↗

SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position

Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-G-201-04: Can the Dynamic Library of Flap Applicators Replace Treatment Planning in Surface Brachytherapy?

Purpose: Contemporary brachytherapy treatment planning systems-(TPS) include the applicator model libraries to improve digitization; however, the library of surface-flap-applicators-(SFA) is not incorporated into the commercial TPS. We propose the dynamic library-(DL) for SFA and investigate if such library can eliminate applicator reconstruction, source activation and dose normalization. Methods: DL was generated for the SFA using the C++class libraries of the Visualization Toolkit-(VTK) and Qt-application framework for complete abstraction of the graphical interface. DL was designed such that the user can initially choose the size of the applicator that corresponds to the one clinically placed to the patient. The virtual applicator-(VA) has an elastic property so that it can be registered to the clinical CT images with a real applicator-(RA) on it. The VA and RA matching is performed by adjusting the position and curvature of the VA. The VA does not elongate or change its size so each catheter could always be at a distance of 5mm from the skin and 10mm apart from the closest catheter maintaining the physical accuracy of the clinical setup. Upon the applicator placement, the dwell positions were automatically activated, and the dose is normalized to the prescription depth. The accuracy of source positioning was evaluated using various applicator sizes. Results: The accuracy of the applicator placement was in the sub-millimeter range. The time-study reveals that up to 50% of the planning time can be saved depending on the complexity of the clinical setup. Unlike in the classic approach, the planning time was not highly dependent on the applicator size. Conclusion: The practical benefits of the DL of the SFA were demonstrated. The time demanding planning processes can be partially automated. Consequently, the planner can dedicate effort to fine tuning, which can result in the improvement of the quality of treatment plans in surface brachytherapy.

60 APPLIED LIFE SCIENCES↗

Three-dimensional printing of wood

Natural wood has served as a foundational material for buildings, furniture, and architectural structures for millennia, typically shaped through subtractive manufacturing techniques. However, this process often generates substantial wood waste, leading to material inefficiency and increased production costs. A potential opportunity arises if complex wood structures can be created through additive processes. Here, we demonstrate an additive-free, water-based ink made of lignin and cellulose, the primary building blocks of natural wood, that can be used to three-dimensional (3D) print architecturally designed wood structures via direct ink writing. The resulting printed structures, after heat treatment, closely resemble the visual, textural, olfactory, and macro-anisotropic properties, including mechanical properties, of natural wood. Our results pave the way for 3D-printed wooden construction with a sustainable pathway to upcycle/recycle natural wood.

36 MATERIALS SCIENCE↗

Visualization of the impatiens downy mildew pathogen using fluorescence in situ hybridization (FISH)

Background: Plasmopara obducens is the biotrophic oomycete responsible for impatiens downy mildew, a destructive disease of Impatiens that causes high crop loss. Currently, there are no available methods for the microscopic detection of P. obducens from leaves of impatiens, which may be contributing to the spread of the disease. Fluorescence in situ hybridization (FISH) is a sensitive and robust method that uses sequence-specific, fluorescence-labeled oligonucleotide probes to detect target organisms from the environment. To study this important pathogen, we developed and standardized a FISH technique for the visualization of P. obducens from Impatiens walleriana tissues using a species-specific 24-mer oligonucleotide probe designed to target a region of the rRNA internal transcribed spacer 2 (ITS2). Results: Since P. obducens cannot be propagated in vitro, we developed a custom E. coli expression vector that transcribes the P. obducens rRNA-ITS target sequence (clone-FISH) for use as a control and to optimize hybridization conditions. The FISH assay could detect P. obducens sporangiophores, sporangia and oospores, and hyphae from naturally infected I. walleriana leaves and stems. Cross-reactivity was not observed from plant tissue, and the assay did not react when applied to E. coli with self-ligated plasmids and non-target oomycete species. Conclusions: This FISH protocol may provide a valuable tool for the study of this disease and could potentially be used to improve early monitoring of P. obducens , substantially reducing the persistence and spread of this destructive plant pathogen.

59 BASIC BIOLOGICAL SCIENCES↗

Gamma-ray imaging and holdup assays of 235-F PuFF cells 1 & 2

Savannah River National Laboratory (SRNL) Nuclear Measurements (L4120) was tasked with performing enhanced characterization of the holdup in the PuFF shielded cells. Assays were performed in accordance with L16.1-ADS-2460 using two high-resolution gamma-ray detectors. The first detector, an In Situ Object Counting System (ISOCS)-characterized detector, was used in conjunction with the ISOCS Geometry Composer software to quantify grams of holdup. The second detector, a Germanium Gamma-ray Imager (GeGI), was used to visualize the location and relative intensity of the holdup in the cells. Carts and collimators were specially designed to perform optimum assays of the cells. Thick, pencil-beam tungsten collimators were fabricated to allow for extremely precise targeting of items of interest inside the cells. Carts were designed with a wide range of motion to position and align the detectors. A total of 24 measurements were made, each typically 24 hours or longer to provide sufficient statistical precision. This report presents the results of the enhanced characterization for cells 1 and 2. The measured gram values agree very well with results from the 2014 study. In addition, images were created using both the 2014 data and the new GeGI data. The GeGI images of the cells walls reveal significant Pu-238 holdup on the surface of the walls in cells 1 and 2. Additionally, holdup is visible in the two pass-throughs from cell 1 to the wing cabinets. This report documents the final element (exterior measurements coupled with gamma-ray imaging and modeling) of the enhanced characterization of cells 1-5 (East Cell Line).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗