Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Heat transfer and pressure drop in hexagonal ducts with surface dimples

Measurements of detailed Nusselt number (Nu) distributions and pressure drop coefficients (f) for four hexagonal ducts with smooth and dimpled walls are performed to comparatively examine the thermal performances of three sets of dimpled walls with concave-concave, convex-convex and concave-convex configurations at Reynolds numbers (Re) in the range of 900-30,000. A set of selected experimental data illustrates the influences of dimple configuration and Re on the detailed Nu distributions, the area-averaged Nu over developed flow region (Nu-bar) and the pressure drop coefficients. Relative enhancements of Nu and f from the smooth-walled references (Nu{sub {infinity}} and f{sub {infinity}}) along with the thermal performance factor ({eta}) defined as (Nu-bar/Nu{sub {infinity}})/(f/f{sub {infinity}}){sup 1/3} are examined. Nu-bar and f correlations are individually obtained for each tested hexagonal duct using Re as the controlling parameter. (author)

42 ENGINEERING↗

A computational parametric study of ducted fuel injection implementation in a heavy-duty diesel engine

Experiments have shown that ducted fuel injection (DFI) effectively reduces soot emissions from direct-injection diesel engines. Although many computational studies have evaluated DFI’s spray development and soot reduction mechanisms in constant volume chambers, only limited computational work on internal combustion engines exists. The DFI duct assembly changes the engine’s in-cylinder flow, spray, and combustion development. Therefore, current production engine designs might not be optimal for achieving the best engine performance with DFI. Here, this work conducted an extensive numerical study to evaluate how parameter changes affect DFI performance. The parameters include swirl ratio, piston geometry, compression ratio (CR), number of injector orifices, split injection strategy, and exhaust gas recirculation (EGR) in a heavy-duty diesel engine utilizing DFI. The combustion and soot emission data from the Sandia compression ignition optical research engine were used for model validation. Simulations showed that an increased swirl ratio resulted in more intense jet flame-piston interaction, slowing down the combustion heat release during the late combustion stage and leading to lower indicated thermal efficiency (ITE) due to higher exhaust losses. A piston-bowl design with a reentrant inner piston edge yielded the highest thermal efficiency, due to the reduced cylinder head heat transfer loss. Additional injector orifices led to higher efficiency owing to a more advanced combustion phasing. Nevertheless, the maximum pressure rise rate (MPRR) and oxides of nitrogen (NO x ) emissions also increased with the number of injector orifices due to more rapid heat release and higher combustion temperature. Implementation of a split injection strategy combined with a higher EGR rate effectively inhibited the excessive MPRR and NO x formation. In general, the study concluded that DFI is not sensitive to most parameter changes but will benefit from future parameter optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Microstructural Analysis of an HT9 Fuel Assembly Duct Irradiated in FFTF to 155 Dpa at 443ºC

The majority of published data on the irradiation response of ferritic/martensitic steels has been derived from simple free-standing specimens irradiated in experimental assemblies under well-defined and near-constant conditions, while components of long-lived fuel assemblies are more complex in shape and will experience progressive changes in environmental conditions. To insure that the resistance of HT9 to void swelling is maintained under more realistic operating conditions, this study addresses the radiation-induced microstructure of an HT9 ferritic/martensitic (F/M) steel hexagon duct that was examined following a six-year irradiation campaign of a fuel assembly in the Fast Flux Test Reactor Facility (FFTF). The calculated irradiation exposure and operating temperature of the duct location examined were ~155 dpa at ~443ºC. It was found that dislocation networks were contained predominantly a/2<111> Burgers vector. Surprisingly, for such a large irradiation dose, type a<100> interstitial loops were observed at relatively high density. Additionally, a high density of precipitation was observed. These two microstructural characteristics may have contributed to the rather low swelling level of 0.3%. It appears that the inherent swelling resistance of this alloy observed in specimens irradiated under non-varying experimental conditions is not significantly degraded compared to time-dependent variations in neutron flux-spectra, temperature and stress state that are characteristic of actual reactor components.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs

The use of artificial roughness on the underside of the absorber plate is an effective and economic way to improve the thermal performance of a solar air heater. Several experimental investigations, involving different types of roughness elements, have been carried out to improve the heat transfer from the absorber plate to air flowing in solar air heaters. This paper presents an experimental investigation carried out to study the effect of multiple v-rib roughness on heat transfer coefficient and friction factor in an artificially roughened solar air heater duct. The experiment encompassed Reynolds number (Re) from 2000 to 20000, relative roughness height (e/D) values of 0.019-0.043, relative roughness pitch (P/e) range of 6-12, angle of attack ({alpha}) range of 30-75 and relative roughness width (W/w) range of 1-10. Extensive experimentation has been conducted to collect data on heat transfer and fluid flow characteristics of a rectangular duct roughened with multiple v-ribs. Using these experimental data, correlations for Nusselt number and friction factor in terms of roughness geometry and flow parameters have been developed. (author)

14 SOLAR ENERGY↗

HAARP-Induced Ionospheric Ducts

It is well known that strong electron heating by a powerful HF-facility can lead to the formation of electron and ion density perturbations that stretch along the magnetic field line. Those density perturbations can serve as ducts for ELF waves, both of natural and artificial origin. This paper presents observations of the plasma density perturbations caused by the HF-heating of the ionosphere by the HAARP facility. The low orbit satellite DEMETER was used as a diagnostic tool to measure the electron and ion temperature and density along the satellite orbit overflying close to the magnetic zenith of the HF-heater. Those observations will be then checked against the theoretical model of duct formation due to HF-heating of the ionosphere. The model is based on the modified SAMI2 code, and is validated by comparison with well documented experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct numerical simulation of turbulent flow in a rotating square duct

A fully developed turbulent flow in a rotating straight square duct is simulated by direct numerical simulations at Re{sub τ} = 300 and 0 ≤ Ro{sub τ} ≤ 40. The rotating axis is parallel to two opposite walls of the duct and normal to the main flow. Variations of the turbulence statistics with the rotation rate are presented, and a comparison with the rotating turbulent channel flow is discussed. Rich secondary flow patterns in the cross section are observed by varying the rotation rate. The appearance of a pair of additional vortices above the pressure wall is carefully examined, and the underlying mechanism is explained according to the budget analysis of the mean momentum equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flow friction in a wide rectangular duct with a beveled inlet: Informal Notes of Fundamental Fluid Physics Studies

Fundamental streamwise pressure distributions were measured at Idaho State University to address a primary objective of obtaining insight into the apparent evolution of air flow regimes at moderate Reynolds numbers in thin, wide rectangular ducts with converging inlets. Ducts of 3.030 and 4.077 mm spacings s (called three and four mm), having non-dimensional lengths of (L/s) ≈ 500.8 and 372.2 and widths (W/s) ≈ 114.6 and 83.2, respectively, were compared. Flow rates ranged from Reynolds numbers based on hydraulic diameter (Re Dh ) of about 980 to 10,000 and corresponding non-dimensional downstream pressure gradient parameters (-K p ) covered the range 0.038 to 0.0061, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ice Protection of Turbojet Engines by Inertia Separation of Water II : Single-offset-duct System

Investigation of a single-offset-duct system designed to prevent entrance of water into a turbojet engine was conducted on a half-scale nacelle model. An investigation was made to determine ram-pressure recovery and radial velocity profiles at the compressor section and icing characteristics of such a duct system. At a design inlet velocity of 0.77, the maximum ram-pressure recovery attained with effective water-separating inlet was 77 percent, which is considerably less than attainable with a direct-ram inlet. Continuous heating of the accessory-housing surface would be required for inlets that have a small ice storage space.

NOSE SHAPE - DUCTED BODIES↗

In-Duct and Far-Field Experimental Measrements from the ANCF for the Purpose of Improved Broadband Liner Optimization

A process for the design and evaluation of novel broadband acoustic liner concepts with limited fan source information is being evaluated. A pair of advanced broad-bandwidth liners were designed and manufactured for the NASA Glenn Research Center's Advanced Noise Control Fan (ANCF): (i) a constant impedance liner and (ii) a variable impedance liner. The insertion loss of both liners was measured in-duct utilizing the ANCF's Configurable Fan Artificial Noise System in a clean configuration with no-flow. Additionally, the acoustic characteristics of the Variable Impedance Liner were measured in the standard ANCF configuration with and without flow. The experimental setup, in-duct mode power levels, and far-field directivity are presented herein.

Acoustics↗

Numerical Predictions of Mode Reflections in an Open Circular Duct: Comparison with Theory

The NASA Broadband Aeroacoustic Stator Simulation code was used to compute the acoustic field for higher-order modes in a circular duct geometry. To test the accuracy of the results computed by the code, the duct was terminated by an open end with an infinite flange or no flange. Both open end conditions have a theoretical solution that was used to compare with the computed results. Excellent comparison for reflection matrix values was achieved after suitable refinement of the grid at the open end. The study also revealed issues with the level of the mode amplitude introduced into the acoustic held from the source boundary and the amount of reflection that occurred at the source boundary when a general nonreflecting boundary condition was applied.

Duct Modes↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/heccdata/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

Building America Case Study: High Performance Ducts in Hot-Dry Climates; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

?Ducts in conditioned space (DCS) represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. Various strategies exist for incorporating ducts within the conditioned thermal envelope. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of various DCS strategies. Builders were given incentives and design support in exchange for providing site access for construction observation, diagnostic testing, and builder survey feedback. Information from the project was designed to feed into California's 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project complemented information collected in the California project with BEopt simulations of DCS performance in hot/dry climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: High-Performance Ducts in Hot-Dry Climates

Ducts in conditioned space (DCS) represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. Various strategies exist for incorporating ducts within the conditioned thermal envelope. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of various DCS strategies. Builders were given incentives and design support in exchange for providing site access for construction observation, diagnostic testing, and builder survey feedback. Information from the project was designed to feed into California's 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project complemented information collected in the California project with BEopt simulations of DCS performance in hot/dry climate regions.

ARBI↗

Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.

BA-PIRC↗

Percutaneous Transhepatic Cutting Balloon Papillotomy for Removal of Common Bile Duct Stones

We report the case of a 66-year-old female who presented with jaundice secondary to recurrent adenocarcinoma of the gallbladder and several common bile duct stones. Percutaneous papillary dilatation was planned to remove the common bile duct stones. Papilla was dilated through the percutaneous approach with an 8-mm peripheral cutting balloon instead of a standard balloon. All the stones were pushed successfully into the duodenum with a saline flush. No complications were encountered. Use of a peripheral cutting balloon for dilatation of the papilla seems to be safe and effective because it has the advantage of controlled incision and dilatation of the target at low pressures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chylous Ascites: A Rare Complication of Thoracic Duct Embolization for Chylothorax

Thoracic duct embolization represents a safe and effective method to treat postsurgical chylothorax. Complications of this procedure are rare despite transabdominal puncture of lymphatic channels for thoracic duct access, and chylous ascites is unreported. Herein, we describe a case of chylous ascites formation after lymphatic puncture and attempted cannulation. Our management approach is also discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗