Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DRILLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Refactoring the Curiosity Rover's sample handling architecture on Mars

The Curiosity Mars rover sample handling hardware and software were architected assuming that end-to-end sampling operations would occur in a single rover position, from acquisition of a powdered sample with a scoop or drill, through to the cleaning out of all sample residue in the sample chain. However, after analysis of the first drilled samples in Yellowknife Bay, the science team wanted to iterate with additional experiments on Mars and in laboratories on Earth to better understand their results and increase the value of science returned. With the architecture as conceived, the time needed to do so was in direct competition with the exploration of other targets and satisfaction of success criteria during the prime mission.

Kuhn, Stephen↗

Thermal design and validation of Mars 202 gas Dust Removal Tool (gDRT)

As part of the science goals for the planned Mars 2020 mission, two instruments, PIXL and SHERLOC, intend to study the Mars surface at a close scale. These two instruments are planned to be used on smooth rock surfaces that are free of dust and other particles. Such surfaces are prepared by using a drill with an abrading drill bit; residual dust and particles are then blown away using a compressed gas system—the Gas Dust Removal Tool (gDRT). Early in the design process a risk of valve leakage below the vendor’s -20C rating was identified. To mitigate this risk a parallel path was implemented: 1) qualify the valves to operate at -135C, and 2) develop thermal control capability to elevated temperatures in case qualification efforts are unsuccessful. While qualification efforts are ongoing, it is expected that the valves will be qualified to an operating temperature of -135C. In the event that qualification is not successful, thermal control has been realized via a thermally isolated valve configuration and thermostatically controlled heaters. Thermal testing of gDRT has validated this design and enabled thermal model correlation in order to provide more accurate survival energy predictions. The resulting energy consumption for heating the valves at the Jezero landing site represents a minimal impact to the Rover energy budget.

Novak, Keith↗

Modeling Water-Rock Reactions Beneath the Greenheugh Pediment, Gale Crater, Mars

The Mars Science Laboratory Curiosity rover has been exploring the clay rich Glen Torridon unit in Gale crater since sol 2300 of the mission [1]. As identified in orbital data [2], this clay rich area [3] in the Murray formation is overlain with the Greenheugh Pediment unit to the south, which is part of the Stimson Formation [4]. Curiosity acquired the drill sample Hutton in the Upper Murray formation 2 – 3 meters below the Greenheugh Pediment [5,6]. This study uses thermochemical modelling to investigate the hypothesis for alteration in the Murray formation below the Greenheugh Pediment. Specifically, if the contact between the Greenheugh Pediment and Murray sediments was a conduit for diagenetic fluids (a low water/rock scenario) or if subaerial weathering altered the Murray sediments before cementation began (a high water/rock scenario) [6]. Here, we report on preliminary modeling where we have reacted the chemical composition for the Hutton drill sample with Gale Portage Water (GPW) at 25 °C, 50 °C and 200 °C, for 10% Fe3+/Fetot of the host rock.

SMR Turner↗

Commanding Curiosity from the Couch: MSL Remote Operations, Challenges, and Path Ahead

This paper describes how the Mars ScienceLaboratory (MSL) project prepared for and successfully beganCuriosity rover Mars operations from their homes in responseto the COVID-19 work-from-home orders. In a very shortperiod, the team developed procedures and executed a remoteoperations readiness test in parallel with the team's support fornominal operations. Continuing regular rover operations withan entirely remote team had not previously been consideredfeasible due to a variety of factors. These included both thehuman factors, such as multiple concurrent person-to-personinteractions of the uplink planning team, as well as technicalfactors, such as reliance on powerful workstations dedicated tographically intensive software tools used for planning. The testwas conducted on March 12th, with both the downlink anduplink teams successfully simulating a near full planning day.The JPL administration announced the transition to mandatorytelework on Monday, March 16th. MSL stood down the uplinkplanning originally scheduled for the next day while downlinkcontinued monitoring the rover. Full operations then resumedper schedule with nearly the entire operations team teleworkingon Friday, March 20th, during which the team planned roveractivities for three Martian days (sols). These activities includedthe successful drilling of the "Edinburgh" rock target, a highlycomplex contact science activity.As of October 1st, 2020, the Mars Science Laboratory missionoperations team has conducted 88 remote tactical uplink shiftsfor a total of 190 sols of planned rover activity, which accountsfor more than 6% of the mission to date. In this period the roverhas completed four drilling campaigns and driven over 1150meters towards its next major science target – a sulfate bearinggeologic unit at the foot of Mount Sharp. Success has not beenwithout its challenges. Many of these have been addressed whileothers will remain in some form until the team can safely returnto JPL, which in turn is the largest challenge for the future.

Stroupe, Ashley↗

Overview of NASA's RESOURCE (Resource Exploration and Science of OUR Cosmic Environment) Project

The RESOURCE(Resource Exploration and Science of OUR Cosmic Environment) project is supported by NASA’s SSERVI (Solar System Exploration Research Virtual Institute) and is led by Principal Investigator (PI) Dr. Jennifer L. Heldmann and Deputy PIs Dr. Matthew Deans and Dr. Alexander Sehlke at NASA Ames Research Center. RESOURCE is focused on enabling In Situ Resource Utilization (ISRU) near the sites of robotic and/or human missions to enable sustainable and affordable exploration of the Moon and near-Earth objects (NEOs). This year RESOURCE has supported the development of a summary of the current state of knowledge regarding lunar polar volatiles as well as a comprehensive catalog and analysis of NEOs. RESOURCE is developing advanced mission capabilities to enable rapid, collaborative operations for lunar resource exploration missions. Hardware testing has been conducted to evaluate potential contaminants released during lunar polar regolith heating. Volatiles and particulates are the two sources of contamination that will affect the requirements of a water cleanup system, and RESOURCE research has identified the requirement for filtration prior to electrolysis for ISRU. RESOURCE also supports development of next-generation planetary drilling systems with integrated instrumentation within the drill. RESOURCE is also deeply committed to sustained efforts to engage educators, students, and broadening participation among under represented groups, and has partnered with Howard University in Washington, DC to foster minoritized students’ interest in STEAMD (science, technology, engineering, arts, math, design) careers through direct and virtual experiences with NASA Subject Matter Experts.

Jennifer L Heldmann↗

Recent Mineralogical Discoveries in Gale Crater, Mars from the CheMin XRD Instrument, Demonstrating a Watery Past

Curiosity landed in Gale crater August 2012 and has traversed (~27 km) sedimentary rocks that comprise a ~5 km-high mound, informally known as Mount Sharp, to investigate depositional/diagenetic environments and potential habitability. VSWIR spectra revealed the lowermost slopes of Mount Sharp contain mineral assemblages that are indicative of water-rock interactions (1-3), with sulfate-bearing units overlying phyllosilicate-bearing units. This mineralogical succession may mark the beginning of the transition from a relatively wet/warm to a very dry/cold Mars (e.g., 1, 4). Thirty-four powdered rock samples have been analyzed by the CheMin XRD instrument and mineralogical results from the first 6 years of the mission are reviewed in [5]. Here we describe the mineralogical diversity observed over the most recent 4 years. Sediments in the Vera Rubin Ridge (VRR) and Glen Torridon (GT) region were deposited in a lacustrine-fluvial environment and are syndepositional. The mineralogy suggests post-depositional fluid-rock interaction. Differences in mineralogy could have been the result of silica-poor, briny groundwater that destabilized smectite and precipitated hematite in VRR [6]. Other hypotheses include lake water-groundwater mixing or diagenesis driven by deeply sourced fluids altering smectite to precipitate hematite and amorphous silica. Preserved bedforms in the clay-sulfate transition region indicate a change from lacustrine-fluvial to aeolian depositional environments. Mineralogical changes include the identification of goethite along with the disappearance of phyllosilicate. The absence of crystalline Mg-sulfate in drilled samples from this transition region may mean that: 1) Sulfates are concentrated in secondary concretions not sampled by Curiosity’s drill, or 2) Sulfate components are either X-ray amorphous or if crystalline, became amorphous in the relatively low-humidity environment of the rover. Continued exploration of sulfate-rich rocks will elucidate this environmental transition above the phyllosilicate-rich sediments.

V M Tu↗

Idunn Mons as the landing site of the Venera-D mission: scientific relevance and possible operational tests on Mount Etna.

Along with the recently selected NASA DAVINCI [1] and VERITAS [2] missions, and with the ESA EnVision mission [3], the Roscosmos Venera-D mission [4,5] opens the new decade of Venus exploration. Among these missions, the Venera-D is the only one to be equipped with a lander which could drill the surface of Venus and analyze its chemical composition. For this reason, it is crucial to select a future landing site based on its scientific relevance, as well as on safety constraints. We propose here Idunn Mons (Figure 1a), a major large volcano of Imdr Regio, as the landing site for the Venera-D mission. We also indicate Mount Etna in Italy (Figure 1b) as a suitable test site on Earth for drilling tests and in-situ elemental and mineralogical analyses [6,7].

venus↗

Mineralogical Evidence for Environmental Change in the Clay-Sulfate Transition at Gale Crater, Mars

A primary reason for selecting Gale crater as the Mars Science Laboratory (MSL) Curiosity rover landing site was a clear mineralogical transition from Fe/Mg smectite in older strata to hydrated Mg sulfate salts in younger strata observed in orbital visible/shortwave-infrared reflectance data. This transition has been observed in other early-Hesperian terrains on Mars and has been hypothesized to signal a planet-wide change in climate from relatively warm and wet to cold and dry. Curiosity studied the sedimentology and geochemical and mineralogical composition of rocks in this “clay-sulfate transition” region from sols 3052 to 3572 (i.e., March 2021 to August 2022), with arrival at the sulfate unit on sol 3574. Here, we report on the mineralogical measurements made by the CheMin X-ray diffractometer of the six drill targets in the clay-sulfate transition and the first drill target in the sulfate unit. We use compositional data and sedimentological observations to interpret depositional and diagenetic environments and present hypotheses to explain the transition from clay minerals to hydrated Mg sulfates.

E. B. Rampe↗

The Role of Olivine in Fe-Carbonate Formation in Gale Crater, Mars

Carbonates have been identified in remote sensing datasets, martian meteorites, and in-situ with rovers at Gale and Jezero craters. In Gale crater, traces of carbonate have been found by the SAM instrument throughout the Mars Science Laboratory mission, e.g., at Rocknest and Pahrump Hills, with models for carbonate formation at Pahrump Hills explored by [9]. Further up-section, CheMin data of clay-rich Glen Torridon (GT) samples show that five out of seven drill samples from GT contain Fe-carbonate alongside phyllosilicates. The GT sediments were deposited in a lacustrine environment and subsequently underwent multiple episodes of diagenesis. In this work, we explore the role of olivine in the formation of carbonates by modelling the interaction of different martian olivines with a previously modeled Gale groundwater. We then explore the incongruent dissolution of host rocks within the GT sediments by mixing olivine with quantities of the Kilmarie drill sample chemical composition as the reactant rock.

S M R Turner↗

NIAC-23 Project: Accessing Icy Worlds Using Lattice Confinement Fusion (LCF) Fast Fission

Icy World Exploration - Proposed probe capable of powering the probe and a drilling mechanism with enough Watt-electric and Watt thermal to accomplish its mission - Heated and/or (ultra) sonic drilling mechanism will enable the probe to travel through icy crusts - LCF-driven Fast Fission can provide Nuclear Electric Propulsion for shorter journey - Ceres, Europa, Enceladus and Pluto are icy world candidates

icy worlds↗

VIPER Mission Traverse Planning – Design, Strategies, and Dynamics

The Volatiles Investigation Polar Exploration Rover (VIPER) is a lunar polar volatiles prospecting mission developed through NASA’s Science Mission Directorate (SMD) Planetary Science Di-vision[1].VIPER is scheduled to land on Mons Mouton near the lunar South Pole in late 2024. VIPER’s primary mission goal is to characterize the distribution of water and volatiles across a range of thermal environments. This characterization aims to assist in understanding the origin of lunar polar volatiles and also help evaluate the In-Situ Resource Utilization (ISRU) potential of the lunar poles. The VIPER rover is a four-wheeled robotic vehicle weighing ~450 kg. It is solar-powered and teleoperated from Earth over a line-of-sight radio link. The rover can move at up to 20 cm/s on flat terrain. Accounting for commanding, localization, navigation, and obstacle-avoidance delays, however, the effective speed is closer to 1 cm/s. This effective speed is known as “Speed Made Good” (SMG), adopted from maritime culture, and kept as a key performance metric for VIPER oper-ations planning, execution, and evaluation. The mission duration is anticipated to be more than 90 Earth days and involves up to 20 km of driving. VIPER’s prospecting payload consists of spectrometers to detect volatiles and assess concentrations, context imagers, and a drill for sub-surface measurements down to one meter depth [2]. Mobility, combined with the prospecting and drill instrument suite, makes VIPER an analytically powerful resource mapper.

Volatiles Investigation Polar Exploration Rover (V↗

Advances in X-ray Instruments to Support Mars Sample Return

The Mars 2020 Perseverance rover is currently collecting drill cores of ancient igneous and sedimentary rock in and around Jezero crater for potential transport to Earth. These samples from the martian surface will enable detailed mineralogical, geochemical, and petrological measurements to characterize ancient depositional and diagenetic environments, quantitatively age-date the samples, and identify the building blocks for life or evidence for life itself. Furthermore, these drill cores are especially precious because they may represent the most pristine samples from the martian surface and our best chance at identifying martian life, as future sample return missions may be conducted by humans that can introduce biological contaminants to the samples. Because of the importance of these samples, we must take great care in their handling, curation, and preliminary analyses so that they are preserved for scientific measurements for decades to come. In-situ measurements by Perseverance have identified minerals that further warrant special treatment of the returned samples. Hydrated sulfate carbonate, swelling clay minerals, and oxychlorine salts are extremely sensitive to changes in temperature and relative humidity. The structures of hydrated sulfates and oxychlorine minerals, in particular, readily change when exposed to different conditions, meaning the mineral assemblage of the as-returned samples may be lost if the samples aren’t handled properly. Characterizing the as-returned mineral assemblage, particularly of the salts, is essential for reconstructing past aqueous conditions and habitability. To characterize the as-returned mineral assemblage, the samples must be analyzed rapidly before phase changes occur and/or under controlled conditions (e.g., within a glove box). Significant recent advances in X-ray instrumentation for robotic exploration of the solar system have resulted in high-resolution miniaturized instruments that would provide mineralogical, geochemical, and petrological information on the returned martian samples without degradation of the mineral assemblage. Here, we describe a combined X-ray diffractometer/X-ray fluorescence spectrometer (XRD/XRF), an X-ray computed tomographic (XCT) instrument, and a scanned beam XRF mapping instrument that could be used in a glove box so that the martian samples remain under controlled conditions.

E. B. Rampe↗

Viper Science Operations: Science Traverse Planning Perspectives, Processes, and Tools.

Introduction: The NASA Volatiles Investigating Polar Exploration Rover (VIPER) launchesin late 2024 towards a landing site on Mons Mouton in the Nobile region of the Lunar South Pole (LSP). As described in other LPSC presentations [1,2,3], the primary objective of the VIPER mission is to study the composition and distribution of hydrogen-bearing and other volatiles by way of a complementary suite of payloads that the rover will carry to the Moon: three “prospecting” instruments which operate continuously while roving - the Neutron Spectrometer System (NSS), the Near InfraRed Volatiles Spectrometer System (NIRVSS), and the Mass Spectrometer observing lunar operations (MSolo). A 1-meter auguring/percussive drill called the The Regolith and Ice Drill for Exploration of New Terrains (TRIDENT) is used to bring subsurface cuttings to the surface in 10-cm increments where they are interrogated by NIRVSS and MSolo. The Visible Imaging System is comprised of eight cameras (the NavCam stereo pair mounted on the mast gimbal, the AftCam stereo pair mounted on the aft panel, and four HazCams mounted in the wheel wells) that capture grayscale visible wavelength images of the lunar environment and the rover’s upper deck. The VIPER mobility system is a four-wheel design that includes the following motorized modules: Suspension, Steering, and Drive/Propulsion. Wheel odometry and applied torque — combined with position data from rover imagery — can be used to compute assessments of ‘slip and sinkage’. Slope estimates can be computed from stereo rover imagery, as well as pitch and roll data from the IMU (Inertial Measurement Unit) and Star Tracker telemetry.

Darlene Sze Shien Lim↗

Effect of Vacuum on Force Response of an Ultrasonic Penetrator

Introduction: The Apollo astronauts encountered higher than expected resistances when interacting with the lunar soil via the Apollo Lunar Surface Drill (ALSD) and the trenching tool. Reducing the force required to move tools or other mechanical components through regolith will impact many steps of the resource extraction process. Force reduction has been achieved in soil materials by imparting vibration to tooling interfaces such as a vibratory farming cultivator, a percussive scoop, and ultrasonically resonant penetrators. Vibration-assisted tools in granular media reduce interaction forces by fluidizing a volume around the tool, allowing the tool to progress through a dynamic (fluid) medium instead of a static (solid) medium. This work seeks to quantify ultrasonic vibration’s effect on the force response of a penetrator in lunar soil simulant in vacuum sufficient to be within the molecular flow regime of any disturbed gases. Methods: A custom vacuum chamber setup, CUBEvac, was designed and built to facilitate penetration testing in a high vacuum environment, for comparison to penetration behavior in ambient terrestrial environment. A two-stage pumping system (Agilent Triscroll 600 roughing pump, Agilent VHS-6 oil diffusion pump) reached chamber pressures of about 5x10-6 Torr with regolith simulant in place. Figure 1 is a schematic of the heart of the assembly (note the penetration drive mechanisms above the chamber feedthrough and the regolith simulant sample in the bottom are not shown). The penetration actuation stack was comprised of a stepper motor driving a lead screw to move the ultra-sonic probe vertically inside the chamber. Motion was coordinated with an Arduino Uno. GRC-3 lunar simulant was used for this set of experiments. Samples were prepared in a four-liter stain-less steel, cylindrical pot with an internal diameter of approximately 15.56 cm (6.125 in) and a depth of 19.37 cm (7 5/8 in) for testing. The soil was baked out prior to compaction preparation as a measure to reduce soil moisture which interfered with pump down capacity. The soil was not baked again if it was removed from the vacuum chamber, prepped, and immediately returned to the vacuum chamber for pump down. The soil was compacted using a 60 Hz vibration table with a surcharge of 34 kg place on top of the soil in the container. Prepared soil samples weighed approximately 6.5 kg (bulk density 1.895-1.934 g/cm3). Two probe end effectors were tested: A cone penetrometer (static only) with a nominal diameter of 12.7 mm (0.5 in) and a nominal height of 28.6 mm (1.125 in); and a vibrating cylindrical probe measuring 12.7 mm in diameter and 50.8 mm in effective length from the tip (Figure 2). The cylindrical probe vibrated resonantly at 20 kHz with an amplitude 23 μm. The cone penetration tests were conducted to assess potential soil behavior differences in vacuum. The cylinder probe tests were conducted as the primary subject of this investigation to assess force response in vacuum. For each test, a regolith simulant sample was load-ed and compacted in the chamber, which was then evacuated for roughly 18 hours to reach the lowest possible pressure (approximately 5x10-6 Torr for most tests). The probe was then moved to about 10 mm above the soil surface before being pushed to a depth of 50 mm for the cylinder probe tests and to a depth of 100 mm for the cone penetrometer tests, both at a speed of 2 mm/s. The simulant samples were prepared the same for all tests. Ideally, they would respond consistently to probe penetration under ambient and vacuum conditions. This was evaluated by measuring the resistance of representative prepared simulant beds with a standard cone penetrometer in both environments. Results and Discussion: The resistance of the simulant samples in the vacuum tests was consistently lower than in the ambient tests as determined by the cone penetration tests. Thus, the ambient and vacuum results cannot be compared directly; work is underway to de-confound and better correlate the data. Still, figures 3-6 show that probe penetration forces are lower overall in the vacuum environment. In both environments, resonant vibration of the probe provides two useful effects: It reduces the probe penetration force and smooths the force-depth curve, significantly reducing local maxima. These effects have implications for various potential applications, such as astronaut hand-tools, where benefits (reducing astronaut effort) outweigh the cost of the additional energy re-quired to generate vibration. These results demonstrate that resonantly vibrating tools can meaningfully reduce the penetration force required for excavation, probing, and drilling tools in simulated lunar regolith deposits under vacuum levels approaching those that will be experience on the Moon’s surface. Lunar-gravity, ambient environment tests are scheduled soon. The effects of realistic temperatures and temperature gradients and deeper vacuum remain to be tested.

E Rezich↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC): A Payload Designed for Exploration of Terrestrial Planetary Bodies

Geological materials (indeed, all solid objects) are characterized by their crystal structure, elemental composition, and morphology. The Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC) instrument suite quantifies all three. These measurements address fundamental science questions (e.g., the origin and evolution of planetary bodies) and support the human exploration of space (e.g., the characterization of regolith for ISRU and the constraint of its geotechnical properties). METRIC comprises an X-ray Diffraction/X-ray Fluorescence instrument (XRD: mineral structure and XRF: elemental composition), an X-ray micro-Computed Tomography instrument (XCT: 3D internal micromorphology), and a hyperspectral imaging infrared spectrometer (IRS) to provide local/regional mineralogic context for these measurements. METRIC XRD/F draws heritage from the highly successful Mars Science Laboratory CheMin instrument. The METRIC XRD/F employs two separate sample cells, one optimized for XRD and one for XRF, resulting in more rapid XRD analysis (tens of minutes vs. tens of hours for CheMin) and an orders-of-magnitude improvement in XRF detection. XCT has not been deployed in space, so the METRIC XCT represents a new capability for solar system exploration. The XCT uses the same basic high-TRL components as METRIC XRD/F, decreasing its development cost for flight. The METRIC IRS is a derivative of the NASA Earth Science Technology Office funded Hyperspectral Thermal Imager instrument and utilizes the NASA Technology Transfer Program to incorporate a commercial-of-the-shelf infrared camera ruggedized for space by NASA Marshall Space Flight Center. The IRS spectral range (8–14 µm) and resolution (10.8 cm -1 ) are tailored to quantify mineralogy in rocks using their characteristic Reststrahlen bands and to characterize mineralogy of soils using the position of the Christensen Feature. The METRIC payload is currently designed for deployment to the Moon on a Commercial Lunar Payload Services (CLPS) mission, where the XRD/F and XCT would be located on a lander and the IRS would be on deployed on a companion rover to evaluate the mineralogical diversity of the landing site. A pneumatic drill designed by Honeybee Robotics would excavate regolith up to 50 cm below the lander and deliver multiple aliquots of regolith to the XRD/F and XCT. The METRIC payload could also be deployed on a rover. In this case, a sample handling system on a robotic arm could scoop regolith and/or drill rocks and deliver powder to the XRD/F and XCT located in the rover’s interior. Alternatively, METRIC instruments could be used singly or in combination on human space missions. The XRD/F and XCT could be used to characterize samples in a rover or in a science laboratory within a habitat. These data could help astronauts identify resource-enriched rocks and regolith and triage geologic samples to return samples of high interest for analysis in terrestrial laboratories. The IRS could be attached to a human-navigated rover to collect mineralogical data along a traverse and identify high-priority science samples.

E. B. Rampe↗

The Collection, Usage, and Preliminary Examination of the Apollo Sample Suite: Lessons for Artemis

Apollo Sample Collection and Usage: From 1969 to 1972 there were six Apollo missions to the surface of the Moon during which the astronauts collected 382 kg of rock and regolith (~2200 samples). The samples collected fall into these general categories: rocks (~66% by mass), rake samples (~4%), bulk regolith (~24%), and specialty regolith (deep drill cores, drive tubes, sealed bulk regolith) samples (~6%). In each category there are a variety of different subtypes available for study, e.g., among the bulk regolith samples there are also skim, trench, and (partially) shaded regolith samples each sampling unique types or depths of regolith. This variety of subsamples has enabled a multitude of different studies over the past 55 years (>3400 individual requests). We are still averaging ~50 unique requests and have allocated >500 individual Apollo samples annually for the past 10 years (2020 excepted). Looking at the 4,675 non-ANGSA (Apollo Next Generation Sample Analysis) samples allocated over the past 10 years, the proportions of allocated samples do not precisely align with the abundance (by mass) of those samples withing the collection: Rock (69.4 %); Rake (10.8 %); Bulk Regolith (15.5 %); Drive Tube (3.3 %); Core/Specialty (1.0 %). Apollo Preliminary Examination (PE): The PE process differs significantly for the various sample types enumerated above; we focus on regolith and rock samples here. During the Apollo mission era, the PE process evolved over the course of the missions; below is what was done for the Apollo 17 mission. For regolith samples, the PE process was: (1) documented bags containing regolith are opened, photographed, and described; (2) large rocks are removed and treated separately; (3) 25% to 33% of the bulk soil is scooped out, weighed, and stored in reserve; (4) the remaining sample is sieved to produce the size fractions <1, 1- 2, 2-4, and 4-10 mm, all of which are weighed. For rock samples, the process is: (1) removing rocks from the container(s) it came back from the Moon in; (2) rematching any materials that spalled off the rock to their original location; (3) numbering, weighing, and basic photographic documentation; (4) dusting with a gentle N2 gas jet; (5) Orthogonal photography; (6) detailed description of the textures and features of the rock; (7) rock modelling and measurement; (8) stereophotography; (9) determination of the orientation of the rock on the lunar surface. Drive tubes and deep drill cores were not characterized during PE beyond an initial weight and a sketch of the interior tube materials derived from 2D medical X-ray images. Catalogs: The ongoing utility of the Apollo samples is enabled by the robust cataloguing process for the samples [3-5], which allows the scientific community to accurately request samples uniquely suited to their proposed studies. A common misconception, however, is the amount of detail that goes into the initial catalog (e.g., [6]) for a collection from the preliminary examination (PE) period, versus what goes into the catalogs that come later in the life cycle of the samples from that mission (e.g., [7]). The only required data for a PE catalog is a weight, a basic photograph, and a description of the nature of the sample. Artemis PE: Over the past few years, the ongoing ANGSA project studied previously unopened Apollo 17 double drive tube samples 73001/2 [1], and a PE of the drive tubes was done. The PE took the existing core dissection process (developed during PE of Apollo cores in the 1970s, 1980s), and modernized it [7]. The main lesson from the ANGSA PE relative to future missions was that the physical work done during PE of lunar samples has not changed much over the past 5 decades. The use of “modern” technology during PE (e.g., XCT; multispectral analyses) resulted in an enhanced initial understanding of the 73001 and 73002 drive tubes, but greatly increased the time required. The lessons learned from recent astromaterial PEs (e.g., ANGSA and OREx) are important to consider when planning for Artemis, but the unique nature of the Artemis Campaign means many lessons learned from these mission will not be applicable. Given the time constraints (6 months) and likely number of samples that will be returned by Artemis (>200), the Artemis PE catalog will necessarily look much more like [4] than [6].

J Gross↗

Evaluating Lunar Water Processing System Model Configurations for Small Scale Oxygen and Hydrogen Production Within JAXA'S ISRU Technology

Introduction: In-Situ Resource Utilization (ISRU) refers to novel methods of extracting and processing local resources for use in life support and propulsion systems, reducing or eliminating the required consumables to be transferred from Earth. Current estimates of water-ice availability embedded in regolith within the Moon’s permanently shadowed regions (PSR’s) range between 1-5% by weight. However, the composition and characteristics of the “wet” regolith is unknown. Alternate ISRU excavation techniques and Concept of Operations (ConOps) must be explored to optimize surface system operations based on these factors. To assess the feasibility of different ISRU subsystem technologies and compare system architecture configurations, an interchangeable system model was generated to incorporate technologies spanning excavation of raw materials to storage of products and determine optimal arrangement of total system processing needs. Total Mass, Volume, and Power (M/V/P) requirements were computed for 168 design iterations of this water processing plant. System Model: In FY24, the System Engineering and Integration (SE&I) ISRU Modeling and Analysis (SIMA) team developed a lunar water processing system model using the Mission Analysis and Integration Tool (MAIT) to estimate the M/V/P for ISRU subsystems operating under a wide range of Hydrogen (H2) and Oxygen (O2) production targets for the Space Technology Mission Directorate (STMD) [1]. Based on Japan Aerospace Exploration Agency’s (JAXA) surface operational requirements, this system architecture was modified to include the ability to excavate consolidated icy regolith (versus granular ice excavation using Kennedy Space Center’s (KSC) ISRU Pilot Excavator, IPEx) and explore the feasibility of processing the lunar water both inside and outside of the PSR. For the consolidated icy regolith case study, excavation was performed via a mobility transport chassis outfitted with The Regolith Ice Drill for Exploring New Terrain (TRIDENT) for drilling [2] and the Cold Operable Lunar Deployable Arm (COLDArm) [3] for regolith transfer. The system model determines the required rover and payload. M/V/P to handle the required regolith processing rates. The regolith is then sorted and heated to sublimate the ice (via an auger dryer). The exiting high temperature, low pressure vapor is cleaned of volatiles (via cold trap) and electrolyzed to produce H2 and O2. These products are then dried, liquified with 20 K and 90 K cryocoolers (for H2 and O2, respectively), and stored in cylindrical tanks. Study Goals: Due to the different ConOps options of regolith transport to the ridge for processing versus processing it directly inside the PSR, as well as the unknown regolith/water-ice composition, new excavation techniques and their power configurations are being evaluated within a ISRU system architecture for production targets less than NASA’s pilot plant (1 mT). This analysis investigates the feasibility of numerous excavation techniques, power architectures, and logistical operations and determines an optimal system configuration with regards to M/V/P. It aims to investigate which parameters, both locally and globally, have the greatest effect on each subsystem within the plant. This can be used to identify the most critical components of the plant, and guide future decisions on allocating funding for research and development. The results from this study may provide subsystem developers with appropriate interfaces with excavation subsystems and downstream processes, and assessing the overall feasibility of each excavation technique, power architecture, and logistical timeframe. References: [1] Carlson, A. et. al. (2024) ICES. [2] Zacny, K., et. al. (2024) “ASCE Earth and Space”. [3] McCormick, R., et. Al. (2024) IEEE Xplore.

ISRU↗

Laser Cutting of Anorthosite and Norite in Vacuum

Lasers have previously been evaluated to cut and drill through rock in high pressure and atmospheric conditions to support deep drilling for oil & gas, as well as breaking or cutting rock near the surface. This research evaluates using lasers to cut rocks in a lunar environment. Anorthosite and norite samples were cut in a rough vacuum (<1 Torr) environment using a continuous wave (CW) 2 kW laser. Power and cutting speed are varied to control the total power input. In total 30, 38mm cuts are performed with power levels ranging from 25% (525 W) to 100% (2100 W) and total energy inputs from 0.090 – 4.34 kJ/cm. The cuts are bisected and inspected with optical and scanning electron microscopy. The bisected areas are measured to determine the specific energy for material removal (J/mm 3 ) and the extent of the heat affected zone.

Laser Cutting↗