Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

ATHENA detector proposal—a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.

47 OTHER INSTRUMENTATION↗

Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.

47 OTHER INSTRUMENTATION↗

Detector configuration of DECIGO/BBO and identification of cosmological neutron-star binaries

The primary target for the planned space-borne gravitational wave interferometers DECIGO/BBO (Decihertz Interferometer Gravitational Wave Observatory/Big Bang Observer) is a primordial gravitational wave background. However there exist astrophysical foregrounds, and among them, gravitational waves from neutron-star (NS) binaries are the solid and strong component that must be identified and subtracted. In this paper, we discuss the geometry of detector configurations preferable for identifying the NS/NS binary signals. As a first step, we analytically estimate the minimum signal-to-noise ratios of the binaries for several static detector configurations that are characterized by adjustable geometrical parameters, and determine the optimal values for these parameters. Next we perform numerical simulations to take into account the effect of detector motions, and find reasonable agreements with the analytical results. We show that, with the standard network formed by 4 units of triangle detectors, the proposed BBO sensitivity would be sufficient in receiving gravitational waves from all the NS/NS binaries at z{<=}5 with signal-to-noise ratios higher than 25. We also discuss the minimum sensitivity of DECIGO required for the foreground identification.

79 ASTRONOMY AND ASTROPHYSICS↗

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for long-lived neutral particles decaying into lepton jets in proton-proton collisions at $ \sqrt{s}=8 $ TeV with the ATLAS detector

Several models of physics beyond the Standard Model predict neutral particles that decay into final states consisting of collimated jets of light leptons and hadrons (so-called “lepton jets”). These particles can also be long-lived with decay length comparable to, or even larger than, the LHC detectors’ linear dimensions. This paper presents the results of a search for lepton jets in proton-proton collisions at the centre-of-mass energy of $ \sqrt{s}=8 $ TeV in a sample of 20.3 fb collected during 2012 with the ATLAS detector at the LHC. Limits on models predicting Higgs boson decays to neutral long-lived lepton jets are derived as a function of the particle’s proper decay length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron Ion Collider Machine Detector Interface

Here we review the major physics requirements, accelerator challenges and some magnet design issues for the Machine Detector Interface (MDI) of an Electron Ion Collider (EIC) Interaction Region (IR). In order to fully exploit the rich physics potential of an EIC, an IR MDI team must balance a complex interplay that arises when combining hadron and electron collider accelerators in an optimized IR. The work described in this paper results from ongoing close collaboration between many people at BNL, JLab and other institutes to realize an EIC as the next, highest priority, future nuclear physics project.

43 PARTICLE ACCELERATORS↗

Towards a Muon Collider

A multi TeV Muon Collider is required for the full coverage of Terascale physics. The physics potential for a Muon Collider at {approx}3 TeV and integrated luminosity of 1 ab{sup -1} is outstanding. Particularly strong cases can be made if the new physics is SUSY or new strong dynamics. Furthermore, a staged Muon Collider can provide a Neutrino Factory to fully disentangle neutrino physics. If a narrow s-channel resonance state exists in the multi-TeV region, the physics program at a Muon Collider could begin with less than 10{sup 31} cm{sup -2} s{sup -1} luminosity. Detailed studies of the physics case for a 1.5-4 TeV Muon Collider are just beginning. The goals of such studies are to: (1) identify benchmark physics processes; (2) study the physics dependence on beam parameters; (3) estimate detector backgrounds; and (4) compare the physics potential of a Muon Collider with those of the ILC, CLIC and upgrades to the LHC.

43 PARTICLE ACCELERATORS↗

Particle and nuclear physics instrumentation and its broad connections

Subatomic physics shares with other basic sciences the need to innovate, invent, and develop tools, techniques, and technologies to carry out its mission to explore the nature of matter, energy, space, and time. In some cases, entire detectors or technologies developed specifically for particle physics research have been adopted by other fields of research or in commercial applications. In most cases, however, the development of new devices and technologies by particle physics for its own research has added value to other fields of research or to applications beneficial to society by integrating them in the existing technologies. Thus, detector research and development has not only advanced the current state of technology for particle physics, but has often advanced research in other fields of science and has underpinned progress in numerous applications in medicine and national security. At the same time particle physics has profited immensely from developments in industry and applied them to great benefit for the use of particle physics detectors. Finally, this symbiotic relationship has seen strong mutual benefits with sometimes unexpected far reach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of o-Ps detection with a cylindrical array of NaI detectors

Ortho-positronium (o-Ps) is a bound state of an electron and positron that can provide a means of searching for new physics. We searched and identified o-Ps in our cylindrical array of NaI(Tl) scintillators, developing a technique for tagging on o-Ps with any one of the 24 bars in the array. With high angular efficiency and this new technique, such an experimental setup could be used in a fundamental symmetries search. In particular, we explore the possibility of using such a setup with a search for CP- or CPT-violation in o-Ps.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LISA extreme-mass-ratio inspiral events as probes of the black hole mass function

One of the sources of gravitational waves for the proposed space-based gravitational wave detector, the Laser Interferometer Space Antenna (LISA), are the inspirals of compact objects into supermassive black holes in the centers of galaxies--extreme-mass-ratio inspirals (EMRIs). Using LISA observations, we will be able to measure the parameters of each EMRI system detected to very high precision. However, the statistics of the set of EMRI events observed by LISA will be more important in constraining astrophysical models than extremely precise measurements for individual systems. The black holes to which LISA is most sensitive are in a mass range that is difficult to probe using other techniques, so LISA provides an almost unique window onto these objects. In this paper we explore, using Bayesian techniques, the constraints that LISA EMRI observations can place on the mass function of black holes at low redshift. We describe a general framework for approaching inference of this type--using multiple observations in combination to constrain a parametrized source population. Assuming that the scaling of the EMRI rate with the black-hole mass is known and taking a black-hole distribution given by a simple power law, dn/dlnM=A{sub 0}(M/M{sub *}){sup {alpha}}{sub 0}, we find that LISA could measure the parameters to a precision of {Delta}(lnA{sub 0}){approx}0.08, and {Delta}({alpha}{sub 0}){approx}0.03 for a reference model that predicts {approx}1000 events. Even with as few as 10 events, LISA should constrain the slope to a precision {approx}0.3, which is the current level of observational uncertainty in the low-mass slope of the black-hole mass function. We also consider a model in which A{sub 0} and {alpha}{sub 0} evolve with redshift, but find that EMRI observations alone do not have much power to probe such an evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies of Single Electroweak Bosons at the Tevatron

Tests of the Standard Model with Electroweak Physics have been performed over many decades. In these proceedings, we present several analyses from the Tevatron involving single W or Z bosons. Electroweak (EW) physics has been crucial for discovering and confirming many aspects of the Standard Model (SM). Furthermore, through radiative corrections EW physics allows for indirect views of heavy particles. Indeed the relationship between W boson, top quark, and Higgs boson masses is instrumental in predicting at what mass the Higgs boson may finally be found. In these proceedings, we present several recent analyses from the Tevatron involving single W or Z bosons to test the SM. The Tevatron is a p {bar p} collider at {radical}s = 1.96 TeV located at the Fermi National Accelerator Laboratory. CDF and D0 are its two multi-purpose detectors concentrating on high P{sub T} physics. Both detectors are described in detail elsewhere.

43 PARTICLE ACCELERATORS↗