Transmission of mirror light pipes with triangular, rectangular, rhombic and hexagonal cross section

This paper derives expressions for the transmission of mirror light pipes (MLP) with cross sections exhibiting congruent symmetry. These include rectangular, triangular, rhombic and hexagonal cross sections. For the case of rectangular MLP the transmissions calculated by this method are the same as the transmissions calculated by integrated ray trace methods. Measurements of the transmission of rectangular and triangular MLP were made and compared with calculated transmissions. It is shown that calculated transmissions are consistent with measured transmissions provided a reflectance that varies with incidence angle on the aperture of the MLP is used. A simple expression for this variation was found from the experimental measurements. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thin-film lithium niobate on diamond as a platform for efficient spin-phonon coupling

Negatively charged silicon vacancy (SiV − ) centers in diamond are leading candidates for solid-state quantum memory that can be controlled using electromagnetic or acoustic waves. The latter are particularly promising due to the strong strain response of SiV − , enabling large spin-phonon interaction strengths. Indeed, coherent spin control via surface acoustic waves (SAWs) has been demonstrated and is essential for developing on-chip phononic quantum networks. However, the absence of piezoelectricity in diamond requires an interface with a piezoelectric material for efficient transduction and delivery of acoustic waves to spins in diamonds. Here, we demonstrate a heterogeneously integrated phononic platform that combines thin-film lithium niobate with diamond to enable acoustic control of single SiV − spins. Additionally, leveraging large SAW-induced strain at the location of SiV − , we achieve coherent acoustic control of an electron spin with more than twofold improvement in Rabi frequency compared to state-of-the-art devices based on aluminum nitride on diamond. Furthermore, this work represents a crucial step towards realizing phonon-based quantum information processing systems.

Optically detected magnetic resonance↗

Data from: "Moisture rivals temperature in limiting photosynthesis by trees establishing beyond their cold-edge range limit under ambient and warmed conditions"

This archive contains data files that were used to draw conclusions in “Moisture rivals temperature in limiting photosynthesis by trees establishing beyond their cold-edge range limit under ambient and warmed conditions”, by Moyes et al., 2015. All field research was completed in common garden plots set up as part of the Alpine Treeline Warming Experiment (ATWE) on Niwot Ridge, Colorado, USA.There are two main data file formats in this archive: comma-separated values (.csv), and Microsoft Excel (.xls and .xlsx). .xlsx files can be read using Microsoft Excel and Google Sheets, and .csv files can be read using any simple text editor program, such as TextEdit (Mac) and Notepad (Windows). This .pdf data user’s guide can be read using Adobe Acrobat Reader, or any other compatible software. Seedling photographs and their corresponding leaf area-processed images are available in .jpg/.JPG image format, and can be opened using Preview (Mac) and Photos (Windows). To provide additional spatial context, two types of geospatial files are also published in this data package: ESRI shapefiles (.shp) and .kml files. Shapefiles are compatible with any GIS software able to read the file type (such as QGIS or ESRI’s ArcGIS suite), and .kml files can be opened with Google Earth or Google Maps. Figures 3 and 4 in the publication contain data from Moyes et al. 2013. This publication is cited in the References section in this archive, and data files can be accessed via the Alpine Treeline Warming Experiment project portal on ESS-DIVE. ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Climate change is altering plant species distributions globally, and warming is expected to promote uphill shifts in mountain trees. However, at many cold-edge range limits, such as alpine treelines in the western United States, tree establishment may be colimited by low temperature and low moisture, making recruitment patterns with warming difficult to predict.- We measured response functions linking carbon (C) assimilation and temperature- and moisture-related microclimatic factors for limber pine (Pinus flexilis) seedlings growing in a heating × watering experiment within and above the alpine treeline. We then extrapolated these response functions using observed microclimate conditions to estimate the net effects of warming and associated soil drying on C assimilation across an entire growing season.- Moisture and temperature limitations were each estimated to reduce potential growing season C gain from a theoretical upper limit by 15–30% (c. 50% combined). Warming above current treeline conditions provided relatively little benefit to modeled net assimilation, whereas assimilation was sensitive to either wetter or drier conditions.- Summer precipitation may be at least as important as temperature in constraining C gain by establishing subalpine trees at and above current alpine treelines as seasonally dry subalpine and alpine ecosystems continue to warm.

54 ENVIRONMENTAL SCIENCES↗

NREL Recommends Ways to Cut Building Energy Costs in Half (Fact Sheet)

Building designers and operators could cut energy use by 50% in large office buildings, hospitals, schools, and a variety of stores -- including groceries, general merchandise outlets, and retail outlets -- by following the recommendations of NREL researchers. The innovative energy-saving recommendations are contained in technical support documents and Advanced Energy Design Guides compiled by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rebuilding After Disaster: Going Green from the Ground Up

This how-to guide describes ways to turn a disaster into an opportunity to rebuild with greener energy technologies. Covers such topics as the importance of energy, options for communities, instructions for developing an energy plan, and other considerations. This guide is intended for the community leaders who have experienced a disaster.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Controls Package for High Performance Interior Retrofit [Slides]

For the last few years, networked lighting control (NLCs) have promised significant energy savings beyond what is achieved through a basic light-emitting diode (LED) lighting retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OpenFacadeControl: enabling integration of automated facades with other building systems

Automated facades are, for the most part, still considered as separate from other building systems throughout the design, installation, commissioning, operation, and maintenance cycle. This takes place despite the fact that their energy and comfort performance are deeply interlinked with the operation of lighting and HVAC systems. Over the last two decades, research has shown that there are significant advantages from operating facades as an integrated system with the rest of the building. Nevertheless, significant barriers prevent this type of integration becoming more common. One of them is the lack of a platform that is inexpensive to implement and that easily allows the practical implementation of integrated control algorithms across fenestration and other building systems, using a variety of communications protocols. This is particularly challenging when automated facades are installed in existing buildings, where interaction with legacy building systems that were installed over the past lifetime of the building can require a high degree of interoperability. OpenFacadeControl (OFC) is an open-source controls framework aimed at unified control of facades and other building systems, including the sharing of third-party sensor information. Through leveraging the Volttron controls platform, it allows the integration of systems and sensors that are manufactured by different companies and that use different communications protocols into an ensemble that functions as a single system. OFC is designed to enable integrated control algorithms of varying degrees of complexity, ranging from simple, heuristic controls to more sophisticated approaches like model-predictive control. Use of a research version to test advanced lighting and shading strategies in a full-scale experimental testbed has demonstrated the ease of deploying advanced control solutions using OpenFacadeControl. This paper presents the structure of OpenFacadeControl and a demonstration case showing the use of OFC in laboratory tests of advanced lighting and fenestration controls that coordinated motorized shades communicating via the BACnet building communications standard and lights communicating via internet-protocol-based application programming interface (API), based on the readings of a shared light level sensor communicating via a different API.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rebuilding It Better: Greensburg, Kansas. Kiowa County Courthouse (Brochure)

This document is one in a series of five that showcases the green, sustainable buildings in Greensburg, Kansas. The Kiowa County Courthouse was one of only two buildings left standing after the tornado, which allowed the building to be renovated and refurbished rather than torn down.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Visual Comfort Analysis of Innovative Interior and Exterior Shading Systems for Commercial Buildings using High Resolution Luminance Images

The objective of this study was to explore how calibrated high dynamic range (HDR) images (luminance maps) acquired in real world daylit environments can be used to characterize, evaluate, and compare visual comfort conditions of innovative facade shading and light-redirecting systems. Detailed (1536 x 1536 pixel) luminance maps were time-lapse acquired from two view positions in an unoccupied full scale testbed facility. These maps were analyzed using existing visual comfort metrics to quantify how innovative interior and exterior shading systems compare to conventional systems under real sun and sky conditions over a solstice-to-solstice test interval. The results provide a case study in the challenges and potential of methods of visualizing, evaluating and summarizing daily and seasonal variation of visual comfort conditions computed from large sets of image data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating Complex Window Systems using BSDF Data

Nowadays, virtual models are commonly used to evaluate the performance of conventional window systems. Complex fenestration systems can be difficult to simulate accurately not only because of their geometry but also because of their optical properties that scatter light in an unpredictable manner. Bi-directional Scattering Distribution Functions (BSDF) have recently been developed based on a mixture of measurements and modelling to characterize the optics of such systems. This paper describes the workflow needed to create then use these BSDF datasets in the Radiance lighting simulation software. Limited comparisons are made between visualizations produced using the standard ray-tracing method, the BSDF method, and that taken in a full-scale outdoor mockup.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Haselden/RNL - Research Support Facility Documentary

The US Department of Energy's (DOE) Research Support Facility (RSF) on the campus of the National Renewable Energy Laboratory is positioned to be one of the most energy efficient buildings in the world. It will demonstrate NREL's role in moving advanced technologies and transferring knowledge into commercial applications. Because 19 percent of the country's energy is used by commercial buildings, DOE plans to make this facility a showcase for energy efficiency. DOE hopes the design of the RSF will be replicated by the building industry and help reduce the nation's energy consumption by changing the way commercial buildings are designed and built.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measuring and Understanding the Energy Use Signatures of a Bank Building

The Pacific Northwest National Laboratory measured and analyzed the energy end-use patterns in a bank building located in the north-eastern United States. This work was performed in collaboration with PNC Financial Service Group under the US DOE’s Commercial Building Partnerships Program. This paper presents the metering study and the results of the metered data analysis. It provides a benchmark for the energy use of different bank-related equipments. The paper also reveals the importance of metering in fully understanding building loads and indentifying opportunities for energy efficiency improvements that will have impacts across PNC’s portfolio of buildings and were crucial to reducing receptacle loads in the design of a net-zero bank branches. PNNL worked with PNC to meter a 4,000 ft2 bank branch in the state of Pennsylvania. 71 electrical circuits were monitored and 25 stand-alone watt-hour meters were installed at the bank. These meters monitored the consumption of all interior and exterior lighting, receptacle loads, service water heating, and the HVAC rooftop unit at a 5-minute sampling interval from November 2009 to November 2010. A total of over 8 million data records were generated, which were then analyzed to produce the end-use patterns, daily usage profiles, rooftop unit usage cycles, and inputs for calibrating the energy model of the building.