Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Measurement of the gas gain and understanding the gas flow in the Mu2e Tracker

The Mu2e experiment will search for the charged-lepton flavor violating (CLFV) neutrinoless conversion of a negative muon into an electron in the field of an Aluminum nucleus µ − N → e − N. The signature of this process is the emission of a monochromatic electron with an energy of 104.97 MeV. The Mu2e Tracker is a low mass straw tube detector, whose aim is to measure the position and the momentum of the electron. In past measurements, high values of currents were found in some panels of the Tracker in absence of any radioactive sources. In this report new measurements of currents, that were taken with the panel MN084 of the Mu2e Tracker are described. Moreover, the addition of a small amount of water vapour in the gas mixture and the influence of the environmental conditions on the currents of the panel are studied.

47 OTHER INSTRUMENTATION↗

First Measurement of the Electron-Neutrino Charged-Current Pion Production Cross Section on Carbon with the T2K Near Detector

The T2K Collaboration presents the first measurement of electron neutrino-induced charged-current pion production on a predominantly carbon target in a restricted kinematical phase space. This is performed using data from the 2.5° off-axis near detector, ND280. The differential cross sections with respect to the outgoing electron and pion kinematics, in addition to the total flux-integrated cross section, are obtained. Comparisons between the measured and predicted cross-section results using the neut, genie, and nuwro Monte Carlo event generators are presented. The measured total flux-integrated cross section is [2.52 ± 0.52⁢(stat) ± 0.30⁢(syst)] × 10 −39 cm 2 nucleon −1 , which is lower than the event generator predictions.

Neutrinos↗

Reconstructing Quasar Spectra and Measuring the Lyα Forest with SpenderQ

Quasar spectra carry the imprint of foreground intergalactic medium (IGM) through absorption features. In particular, absorption caused by neutral hydrogen gas, the "Lyα forest," is a key spectroscopic tracer for cosmological analyses used to measure cosmic expansion and test physics beyond the standard model. Despite their importance, current methods for measuring Lyα absorption cannot directly derive the intrinsic quasar continuum and make strong assumptions on its shape, thus distorting the measured Lyα clustering. We present SpenderQ , a ML-based approach for directly reconstructing the intrinsic quasar spectra and measuring the Lyα forest from observations. SpenderQ uses the Spender spectrum autoencoder to learn a compact and redshift-invariant latent encoding of quasar spectra, combined with an iterative procedure to identify and mask absorption regions. To demonstrate its performance, we apply SpenderQ to 400,000 synthetic quasar spectra created to validate the Dark Energy Spectroscopic Instrument Year 1 Lyα cosmological analyses. SpenderQ accurately reconstructs the true intrinsic quasar spectra, including the broad Lyβ, Lyα, SiIV, CIV, and CIII emission lines. Redward of Lyα, SpenderQ provides percent-level reconstructions of the true quasar spectra. Blueward of Lyα, SpenderQ reconstructs the true spectra to < 5%. SpenderQ reproduces the shapes of individual quasar spectra more robustly than the current state-of-the-art. We, thus, expect it will significantly reduce biases in Lyα clustering measurements and enable studies of quasars and their physical properties. SpenderQ also provides informative latent variable encodings that can be used to, e.g., classify quasars with Broad Absorption Lines. Overall, SpenderQ provides a new data-driven approach for unbiased Lyα forest measurements in cosmological, quasar, and IGM studies.

Hahn, ChangHoon [Arizona U., Astron. Dept. - Stewa↗

Review of thermophysical property methods applied to fueled and un-fueled molten salts

Recent investigation into designs of molten salt reactors (MSR) requires accurate data of candidate salts. Review of the literature shows lacking thermophysical (TP) property data for coolants and fuel-bearing salts of Advanced High Temperature Reactors (AHTR). Measurement uncertainties of current data are even more deficient, and this affects ongoing research where MSR modeling and testing are being performed. Melting temperature, viscosity, density, specific heat capacity, and thermal and electrical conductivity measurements are often not arranged together or discussed in great detail, especially for fuel-bearing salts. Raw data from key findings spanning over 70 years for LiF, LiF-BeF 2 , LiF-NaF-KF, KCl-MgCl 2 , KF-ZrF 4 , and NaF-KF-MgF 2 have been organized and presented here. Brief description of methods used to obtain these results, in addition to the TP data of some of these salts as fuel carriers, has also been discussed. Thermal conductivity data are particularly weak due to older, high-error measurement techniques. More recent measurement systems to evaluate salt thermal conductivity show promise for obtaining consistent absolute values. This work concludes that measurement systems such as transient hot-wire method, forced Rayleigh scattering, and laser flash analysis provide the most promise to fill these data gaps and reduce current uncertainty in thermal conductivity measurements of both fueled and un-fueled molten salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion Number Density Quantification Utilizing Pulsing Frequency in Negative Differential Resistance (NDR) Regime of Microplasma Operation

A mathematical model is presented for quantifying the ion number density over a range of discharge current in microplasma discharges. The ion number density is determined from measured discharge voltage, current, pulsing frequency, and trace impurity that is injected into the system deliberately. Experiments are conducted in pure helium with nitrogen being introduced as the trace species. The ion number density is estimated over a range of discharge current and is compared with multidimensional simulation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the \bar \nu_\mu- Hydrogen Charged-Current Elastic Cross Section in the NOvA Near Detector

We report a measurement of the total cross-section for muon antineutrino charged-current elastic scattering on hydrogen in the NOvA near detector using $12 \times 10^{20}$ protons-on-target in the NuMI beam, delivered from June 2016 to July 2019. An analysis based on topological and kinematic constraints allows the selection of the largest sample of (anti)neutrino-hydrogen interactions measured to date in the hydrogen-rich target (∼ 11%) of the NOvA detector. Backgrounds from (anti)neutrino interactions on heavier nuclei are determined using dedicated data control samples, significantly reducing the corresponding systematic uncertainties.

Talukdar, Nibir [South Carolina U., Aiken] (ORCID:↗

Surprising Relationship between Silicon Anode Calendar Aging and Electrolyte Components in a Localized High-Concentration Electrolyte System

Although localized high-concentration electrolytes (LHCEs) have been shown to improve the calendar lifetime of silicon anodes, the roles of the electrolyte constituents in calendar aging are not well understood. Here, in this work, we utilize a voltage hold protocol and an LHCE with varying molar ratios of lithium bis(fluorosulfonyl)imide (LiFSI), tetramethylene sulfone (TMS), and 1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropyl ether (TTE) to probe the component roles during aging. Interestingly, the estimated calendar lifetime and irreversible lithium losses from the V-hold experiments are independent of the electrolyte formulations. Contrarily, the solid electrolyte interphase (SEI) composition depends on the electrolyte formulation. X-ray photoelectron spectroscopy shows that TMS-coordinated species decompose to form insoluble alkanes and lithium hydroxide (LiOH), while lithium fluoride (LiF) originates from the anion-coordination complex. The SEI composition does not appear to play a significant role in the silicon anode passivity, as measured by parasitic current, suggesting that the SEI-electrolyte interactions dictate the calendar aging mechanisms.

Si anode↗

Measurement of Triple-Differential Inclusive Muon Neutrino Charged-Current Cross Sections on Argon with the MicroBooNE Detector

We report the first measurement of the differential cross section $d^2σ(E_ν)/dcos(θ_µ)dP_µ$for inclusive muon neutrino charged-current scattering on argon. This measurement utilizes data from6.5×10 20 protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located on-axis in the Fermilab Booster Neutrino Beam with a mean neutrino energy of approximately 0.8 GeV. In this note, the mapping from reconstructed kinematics to truth quantities, particularly from reconstructed to true neutrino energy, is validated by comparing the distribution of reconstructed hadronic energy in data to that of the model prediction in different muon scattering angle bins after conditional constraint from the muon momentum distribution in data. The success of this validation gives confidence that the missing energy in the MicroBooNE detector is well-modeled within its uncertainties in simulation, enabling the unfolding to an energy-dependent triple-differential measurement over muon momentum, muon scattering angle, and neutrino energy. The unfolded measurement covers an extensive phase space, providing a wealth of information useful for future LArTPC experiments measuring neutrino oscillations. Comparisons with model predictions show the best agreement with Neut 5.4.0.1 at low energy, and with NuWro 19.02.01 at higher energies, particularly at forward muon scattering angles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Comparative Study of Redox Mediators for Improved Performance of Li-Oxygen Batteries.

Redox meditators (RMs) are soluble catalysts located in an electrolyte that can improve the energy efficiency (reduced overpotential) and cyclability of Li-oxygen (Li-O-2) batteries. In this work, 20 RMs within a Li-O-2 system with dimethyl sulfoxide and tetraethylene glycol dimethyl ether electrolytes are studied and their electrochemical features such as redox potential, the separation of cathodic and anodic peaks, and their current intensities are measured using cyclic voltammetry (CV) experiments. Six RMs are selected as "primary" choices based on their electrochemical performance, and stability tests are then performed to examine their electrochemical responses after consecutive cycles. Moreover, galvanostatic cycling tests are performed within a Li-O-2 battery system assembled with selected six RMs for real case consistency investigations. It is found that results from CV to galvanostatic cycling tests are consistent for halides and organometallic RMs, where the former exhibit much higher stability. However, the organic RMs show high reversibility in CV but low in battery cycling results. Density functional theory calculations are carried out to gain more understanding of the stability and redox potentials of the RMs. This study provides comparative information to select the most reliable RMs for Li-O-2 batteries along with new fundamental understanding of their electrochemical activity and stability.

cyclic voltammetry↗

Miniature fluorescence sensor for quantitative detection of brain tumour

Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. These sensing approaches, which rely on collecting the fluorescence light from the tumour resection site and its “remote” spectral sensing, introduce challenges associated with optical losses. In this work, we demonstrate the viability of tumour detection at the resection site using a miniature fluorescence measurement system. Unlike the current bulky systems, which necessitate remote measurement, we have adopted a millimetre-sized spectral sensor chip for quantitative fluorescence measurements. A reliable measurement at the resection site requires a stable optical window between the tissue and the optoelectronic system. This is achieved using an antifouling diamond window, which provides stable optical transparency. The system achieved a sensitivity of 92.3% and specificity of 98.3% in detecting a surrogate tumour at a resolution of 1 × 1 mm 2 . In conclusion, as well as addressing losses associated with collecting and coupling fluorescence light in the current ‘remote’ sensing approaches, the small size of the system introduced in this work paves the way for its direct integration with the tumour resection tools with the aim of more accurate interoperative tumour identification.

59 BASIC BIOLOGICAL SCIENCES↗

Atmospheric clusters to nanoparticles: Recent progress and challenges in closing the gap in chemical composition

Aerosol nanoclusters (AN), defined here as molecular aggregates suspended in a gas with dimensions between 2 and 10 nm, are the link between substances that we think of as molecules, or the “gas phase,” and those that we consider as particles, or the “condensed phase.” The ability to measure and model the physical and chemical properties of size-resolved AN, which at present is rudimentary at best, is crucial for understanding how particles form and evolve in a number of environments that are natural or influenced by human activities. This review describes the current state-of-the-art for measuring and modeling the size-resolved composition of atmospheric AN. We focus specifically on instruments, many relying on mass spectrometry, that show promise for closing the measurement gap under atmospherically relevant conditions by increasing the size of measurable gas-phase clusters (bottom-up approaches) and by decreasing the size of measurable nanoparticles (top-down approaches). Theoretical methods for predicting AN composition have similarly relied on bottom-up approaches that extend the accuracy of quantum chemistry calculations to larger molecular systems, as well as top-down approaches that correct bulk composition aerosol models for size-dependent properties such as viscosity and volatility. Finally, current measurement and modeling challenges that must be overcome in order to close the gap are discussed.

42 ENGINEERING↗

Setups for eliminating static charge of the ATLAS18 strip sensors

Abstract Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration to beable to track charged particles produced at the High-Luminosity LHC, started in 2020 and is expected tocontinue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-psilicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor.During the QC testing of ATLAS18 strip sensors, an increased number of sensors thatfailed the electrical tests was observed. In particular, IV measurements indicated an early breakdown,while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolationwere identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, whichmechanically protect these sensors in their paper envelopes. Accumulated data indicates a clearcorrelation between observed electrical failures and the sensor charge-up.To mitigate the above-described issues, the QC testing sites significantly modified the sensor handlingprocedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UVlight or application of intensive flows of ionized gas. In this presentation, we will describe the setupsimplemented by the QC testing sites to treat silicon strip sensors affected by static charge andevaluate the effectiveness of these setups in terms of improvement of the sensor performance.

Instruments & Instrumentation↗

Enhanced stability of quantum Hall skyrmions under radio-frequency radiations

We present in this paper the results from a recent study on the stability of the quantum Hall skyrmions state at a Landau level filling factor (ν) close to ν = 1 in a narrow GaAs quantum well. Consistent with previous work, a resonant behavior is observed in the resistively detected NMR measurements. In the subsequent current-voltage (I-V) measurements to examine its breakdown behavior under radio frequency radiations, we observe that the critical current assumes the largest value right at the 75 As nuclear resonant frequency. We discuss possible origin for this unexpectedly enhanced stability.

36 MATERIALS SCIENCE↗

Avoidance of disruptions on KSTAR due to vertical displacement events via novel real-time stability assessment

Disruption avoidance via the DECAF approach has been achieved on KSTAR using a novel real-time vertical stability assessment and a multiactuator feedback control strategy. The development of disruption avoidance strategies with reactor-relevant reliability is an urgent activity, enabling future fusion power plants. The stability metric employed is based on a new formulation of a vertical force gradient balance metric evaluated across the poloidal cross section of the plasma, with parameters tuned using historical data. Evaluation of this metric on a validation set of 400 recent KSTAR shots indicates >82% of Vertical displacement events can be avoided via feedback control. Essential to its calculation is the two-dimensional toroidal current density distribution in the plasma. Measurement of this profile faster than fully-converged equilibrium reconstructions can deliver is found to improve forecaster performance and is achieved with a surrogate model that takes as input magnetic diagnostic measurements and outputs the current profile on a basis comprising the top principal components of historical current profiles (from past equilibrium reconstructions). This method solves the non-uniqueness problem typically faced when reconstructing current profiles directly from diagnostics, while improving computational time and accuracy. On average, profiles produced by this model reach coefficients of determination of >0.99 with respect to those from equilibrium reconstructions. The avoidance actuators employed include poloidal field coils and an electron cyclotron current drive system. The multiactuator approach, as shown in this first demonstration, allows disruption avoidance while minimizing impact to operational performance. This ability, along with its flexibility and speed, makes this new approach an attractive option for avoiding these types of disruptions in reactors.

Tobin, Matthew [Columbia Univ., New York, NY (Unit↗

Summary of Alloy 617 and Alloy 709 Elevated Temperature Crack Growth Test Results from the Planned FY24 Crack Growth Test Activities

This report covers the results from crack growth rate testing performed at Idaho National Laboratory in the fiscal year 2024. It includes two creep crack growth rate tests and two creep-fatigue crack growth rate tests. Results are shown for each of these tests, included crack growth measured during the test using direct current potential drop, and measurements based off of the fracture surface. Load line displacement, as well as load, were also collected during the tests. Detailed analysis of the results will continue into the next fiscal year, however, a number of potential improvements to the equipment and testing procedures were identified that will increase testing reliability and throughput, as well as decrease complications with the analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗