Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenic electronic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Arrays of High Performance Thermal Detectors

Thermal detectors have historically been the sensors of choice for applications where photoconductive or photovoltaic detectors are unavailable. While they have the advantage of broad wavelength coverage, a primary disadvantage has been sensitivity; at a given operating temperature, bolometers are typically much less sensitive than photodetectors. The development of cryogenic bolometers has resulted in thermal detectors which can reach fundamental sensitivity limits. When operated at temperatures below 0.3 K these devices can provide background-limited sensitivity for cryogenic imaging and spectroscopy in space. The past decade has seen a rapid growth in sensitivity and array format in cryogenic bolometers. Micromachining technology, combined with advances in superconducting electronics, provides a strong technological base for future developments. I will describe the present state of development of low-temperature thermal detectors, and the possible extension of this technology to higher temperature operation.

Moseley, Harvey↗

Heat pipe systems using new working fluids

The performance of a heat pipe system is greatly improved by the use of a dilute aqueous solution of about 0.0005 and about 0.005 moles per liter of a long chain alcohol as the working fluid. The surface tension-temperature gradient of the long-chain alcohol solutions turns positive as the temperature exceeds a certain value, for example about 40.degree. C. for n-heptanol solutions. Consequently, the Marangoni effect does not impede, but rather aids in bubble departure from the heating surface. Thus, the bubble size at departure is substantially reduced at higher frequencies and, therefore, increases the boiling limit of heat pipes. This feature is useful in microgravity conditions. In addition to microgravity applications, the heat pipe system may be used for commercial, residential and vehicular air conditioning systems, micro heat pipes for electronic devices, refrigeration and heat exchangers, and chemistry and cryogenics.

Chao, David F.↗

A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation

A system for wirelessly measuring the volume of fluid in tanks at non-horizontal orientation is predicated upon two technologies developed at Langley Research Center. The first is a magnetic field response recorder that powers and interrogates magnetic field response sensors [ Magnetic Field Response Measurement Acquisition System, (LAR-16908), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28]. Magnetic field response sensors are a class of sensors that are powered via oscillating magnetic fields and when electrically active respond with their own magnetic fields whose attributes are dependent upon the magnitude of the physical quantity being measured. The response recorder facilitates the use of the second technology, which is a magnetic field response fluid-level sensor ["Wireless Fluid- Level Sensors for Harsh Environments," (LAR-17155), NASA Tech Briefs, Vol. 33, No. 4 (April 2009), page 30]. The method for powering and interrogating the sensors allows them to be completely encased in materials (Fig. 1) that are chemically resilient to the fluid being measured, thereby facilitating measurement of substances (e.g., acids, petroleum, cryogenic, caustic, and the like) that would normally destroy electronic circuitry. When the sensors are encapsulated, no fluid (or fluid vapor) is exposed to any electrical component of the measurement system. There is no direct electrical line from the vehicle or plant power into a fuel container. The means of interrogating and powering the sensors can be completely physically and electrically isolated from the fuel and vapors by placing the sensor on the other side of an electrically non-conductive bulkhead (Fig. 2). These features prevent the interrogation system and its electrical components from becoming an ignition source.

Woodward, Stanley E.↗

Noise parameters and light sensitivity of low-noise high-electron-mobility transistors at 300 and 12.5 K

The four noise parameters of cryogenically cooled HEMTs have been investigated. Two different HEMT structures, with and without a spacer layer, were tested. The noise parameters of both structures were similar at room temperature, while they were dramatically different at cryogenic temperatures. The minimum noise temperatures measured at 8.4 GHz were 75 + or 5 K at room temperature and 8.5 + or - 1.5 K at the temperature of 12.5 K. The cryogenic performance is the best ever observed for field-effect transistors.

Pospieszalski, Marian W.↗

Microcalorimeters for High Resolution X-Ray Spectroscopy of Laboratory and Astrophysical Plasmas

The proposal has three major objectives. The first focuses on advanced neutron-transmutation-doped (NTD)-based microcalorimeter development. Our goal is to develop an array of microcalorimeters with sub- 5 eV energy resolution that can operate with pile-up-free throughput of at least 100 Hz per pixel. The second objective is to establish our microcalorimeter as an essential x-ray diagnostic for laboratory astrophysics studies. We propose to develop a dedicated microcalorimeter spectrometer for the EBIT (electron beam ion trap). This instrument will incorporate the latest detector and cryogenic technology that we have available. The third objective is to investigate innovative ideas related to possible flight opportunities. These include compact, long lived cryo-systems, ultra-low temperature cold stages, low mass and low power electronics, and novel assemblies of thin windows with high x-ray transmission.

Silver, E.↗

Nanoscale-correlated octahedral rotations in BaZrO 3

BaZrO 3 is reportedly one of few perovskites that retains an ideal cubic structure down to zero Kelvin even though its ground state as predicted by first-principles calculations has remained contentious. Here, we combine electron diffraction with total neutron scattering measured on ceramic samples at cryogenic temperatures to demonstrate that below 80 K, this compound undergoes a structural change associated with the onset of correlated out-of-phase rotations of [ZrO 6 ] octahedra. Here, the change is manifested in the appearance of weak but relatively sharp superlattice reflections at ½hkl (h, k, l = odd), which are readily detectable by electron diffraction. Atomistic structural refinements from the total neutron scattering data confirmed that these reflections are associated with octahedral tilting. The observed rotations are consistent with the a 0 a 0 c - type and feature a coherence length of about 3 nm. The average structure of BaZrO 3 , as seen by Bragg diffraction, remains cubic. According to the electron diffraction data, Nb-doped BaZrO 3 undergoes a similar structural transition but in this case, the tilting couldn't be recovered from the neutron scattering, suggesting that the distortions are smaller compared to those in the pure compound.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Cryogenic Temperatures on Spacecraft Internal Dielectric Discharges

Abstract Most calculations of internal dielectric charging on spacecraft use tabulated values of material surface and bulk conductivities, dielectric constants, and dielectric breakdown strengths. Many of these properties are functions of temperature, and the temperature dependences are not well known. At cryogenic temperatures, where it is well known that material conductivities decrease dramatically, it is an open question as to the timescales over which buried charge will dissipate and prevent the eventual potentially disastrous discharges of dielectrics. In this paper, measurements of dielectric charging and discharging for cable insulation materials at cryogenic temperatures (approx. 90 K) are presented using a broad spectrum electron source at the NASA Marshall Space Flight Center. The measurements were performed for the James Webb Space Telescope (JWST), which will orbit at the Earth-Sun L2 point, and parts of which will be perennially at temperatures as low as 40 K. Results of these measurements seem to show that Radiation Induced Conductivity (RIC) under cryogenic conditions at L2 will not be sufficient to allow charges to bleed off of some typical cable insulation materials even over the projected JWST lifetime of a dozen years or more. After the charging and discharging measurements are presented, comparisons are made between the material conductivities that can be inferred from the measured discharges and conductivities calculated from widely used formulae. Furthermore, the measurement-inferred conductivities are compared with extrapolations of recent measurements of materials RIC and dark conductivities performed with the charge-storage method at Utah State University. Implications of the present measurements are also given for other spacecraft that may operate at cryogenic temperatures, such as probes of the outer planets or the permanently dark cratered areas on the moon. The present results will also be of interest to those who must design or operate spacecraft in more moderate cold conditions. Finally, techniques involving shielding and/or selective use of somewhat conductive insulators are presented to prevent arc-inducing charge buildup even under cryogenic conditions.

Ferguson, Dale c.↗

Power Distribution for Cryogenic Instruments at 6-40K The James Webb Space Telescope Case

The Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) operates its instruments passively cooled at around 40 Kelvin (K), with a warm Instrument Electronic Compartment (IEC) at 300K attached to it. From the warm electronics all secondary signal and power harnesses have to bridge this 300-40K temperature difference and minimize the power dissipation and parasitic heat leak into the cold region. After an introduction of the ISIM with its instruments, the IEC with the electronics, and the harness architecture with a special radiator, this paper elaborates on the cryogenic wire selection and tests performed to establish current de-rating rules for different wire types. Finally failure modes are analyzed for critical instrument interfaces that could inject excessive currents and heat into the harness and cold side, and several solutions for the removal of such failures are presented.

Rumler, Peter↗

Improved Charge Sensing on a SiMOS Double Quantum Dot using a Cryogenic Skipper Readout ASIC (Quandarum)

Major outstanding questions in high-energy physics such as the nature of dark matter and the existence of interactions beyond the standard model require new measurement techniques which are extremely sensitive to minute electromagnetic fields. An array of entangled spin qubits is a promising system for building novel detectors due to its combination of sensitivity and controllability. CMOS-based electron spin qubits, which have demonstrated the operational requirements for fault-tolerant quantum computing [1], offer a particular opportunity due to their compatibility with classical electronics, which allows the leveraging of decades of development of low-noise cryogenic detectors for physics. In this work, we combine a SiMOS double-quantum dot device architecture with a state-of-the-art cryoelectronic readout circuit [2-3] aimed to demonstrate improved charge readout using a single-electron transistor (SET). We identify the design characteristics for an SET that facilitate the use of on-chip classical electronics as a low-power, high-bandwidth first amplification stage and explore opportunities for sensor-readout co-design to minimize noise. This is the first of a series of steps to demonstrate high-fidelity readout of a large array of spin qubit with enough sensitivity to probe processes of interest for the investigation of beyond-standard-model physics.

Quinn, Adam [Fermilab]↗

Cryogenically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗

Study of solid molecular deuterium D 2 growth under gas pressure

The injection of high-speed cryogenic pellets made of frozen hydrogen-isotopes, represents to date the most effective method to fuel magnetically confined thermonuclear fusion plasmas. Additionally, the injection of very large pellets composed of cryogenic solid of some suitable impurity (typically a noble-gas such as H 2 , Ne, or H 2 /Ne, D 2 /Ne mixtures), shattered in relatively small fragments just before entering the plasma, seems to be the most promising method to reduce the damage risks for the plasma-facing components in case of a plasma disruption. This technology, known as "Shattered Pellet Injection" (SPI), allows to spread out the plasma energy and mitigate possible damage to the in-vessel components, as well as to densify the plasma to suppress the formation of runaway electrons, and/or dissipate their energy. Several techniques to produce and launch cryogenic pellets have been investigated in the past decades. "Pipe gun" injectors are reliable and relatively simple devices are still commonly used today. They make use of single- or two-stage pneumatic light-gas guns to accelerate the pellet at high speeds. In these injectors, the cryogenic pellets are formed “ in situ ” (i.e., inside the launching barrel), by de-sublimating them directly from the gas phase, i.e., at temperatures and pressures below those of the triple point. The simplest case is pure deuterium pellets ($\mathcal{T}$ < 18.7 K, $\mathcal{P}$ < 171.3 hPa). The production of good quality solid deuterium, capable of withstanding the mechanical stress during the acceleration of the pellets, is a key issue. To this end the phase transition of deuterium from gas to solid (and vice versa) is modeled with extensive molecular-dynamics (MD) simulations. Furthermore, the solid growth from the gas phase is simulated in an ample range of temperatures and pressures, to find the best compromise between growth velocity and mechanical properties of the resulting solid system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Two Fast-Turnaround Dry Dilution Refrigerators for Scanning Probe Microscopy

Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they typically suffer from comparatively worse vibrations than cryogen-based systems, necessitating the understanding and mitigation of vibrations for SPM applications. Here, in this work, we demonstrate the construction of two cryogen-free dilution refrigerator SPMs with minimal modifications to the factory default and we systematically characterize their vibrational performance. We measure the absolute vibrations at the microscope stage with geophones and use both microwave impedance microscopy and a scanning single-electron transistor to independently measure tip-sample vibrations. Additionally, we implement customized filtering and thermal anchoring schemes and characterize the cooling power at the scanning stage and the tip electron temperature. This work serves as a reference to researchers interested in cryogen-free SPMs, as such characterization is not standardized in the literature or available from manufacturers.

36 MATERIALS SCIENCE↗

Nanoscale Mapping of Hydrogen Distribution in Nuclear Structural Materials Using Cryogenic Transfer Atom Probe Tomography

Analyzing hydrogen distribution in nuclear structural materials at sub-nanometer scale spatial resolution has been challenging by electron microscopy. Furthermore, methods such as thermal desorption spectroscopy only provides a bulk estimate of hydrogen concentration with no nanoscale spatial resolution. In the last decade, cryogenic transfer atom probe tomography (APT) has been emerging as an invaluable characterization technique for analyzing the nanoscale distribution of hydrogen isotopes in materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strongly Confined Bismuth Antimonide Quantum Dots

Bismuth antimonide (Bi 1−x Sb x ) has emerged as a highly promising material for quantum applications due to its complex band structure. In this study, spherical Bi 1−x Sb x quantum dots (QDs), with a diameter of around 8 ± 2 nm, were successfully synthesized by pulsed laser ablation in liquids. The energy bandgap was determined at 2.02 ± 0.27 eV, which is significantly higher than the bulk value (∼0.025 eV). The strong confinement nature of the dots was confirmed by the Raman peak shifts. The chemical composition of the Bi 1−x Sb x QDs was measured to be around 77 ± 2 at. % of Bi and 23 ± 2 at. % of Sb. The colloid containing the Bi 1−x Sb x QDs was classified as highly stable, displaying a zeta potential of −38 ± 18 mV. Finally, the Bi 1−x Sb x QDs exhibited an electron spin resonance (ESR) signal at room temperature and at cryogenic temperature (4.2 K); consequently, revealing the presence of paramagnetic states.

Alloys↗

Controllable strain-driven topological phase transition and dominant surface-state transport in HfTe5

Abstract The fine-tuning of topologically protected states in quantum materials holds great promise for novel electronic devices. However, there are limited methods that allow for the controlled and efficient modulation of the crystal lattice while simultaneously monitoring the changes in the electronic structure within a single sample. Here, we apply significant and controllable strain to high-quality HfTe 5 samples and perform electrical transport measurements to reveal the topological phase transition from a weak topological insulator phase to a strong topological insulator phase. After applying high strain to HfTe 5 and converting it into a strong topological insulator, we found that the resistivity of the sample increased by 190,500% and that the electronic transport was dominated by the topological surface states at cryogenic temperatures. Our results demonstrate the suitability of HfTe 5 as a material for engineering topological properties, with the potential to generalize this approach to study topological phase transitions in van der Waals materials and heterostructures.

36 MATERIALS SCIENCE↗

Unconventional solitonic high-temperature superfluorescence from perovskites

Fast thermal dephasing limits macroscopic quantum phenomena to cryogenic conditions and hinders their use at ambient temperatures. For electronic excitations in condensed media, dephasing is mediated by thermal lattice motion. Therefore, taming the lattice influence is essential for creating collective electronic quantum states at high temperatures. Although there are occasional reports of high-T c quantum effects across different platforms, it is unclear which lattice characteristics and electron–lattice interactions lead to macroscopically coherent electronic states in solids. Here we studied intensity fluctuations in the macroscopic polarization during the emergence of superfluorescence in a lead halide perovskite and showed that spontaneously synchronized polaronic lattice oscillations accompany collective electronic dipole emission. We further developed an effective field model and theoretically confirmed that exciton–lattice interactions lead to a new electronically and structurally entangled coherent extended solitonic state beyond a critical polaron density. The analysis shows a phase transition with two processes happening in tandem: incoherent disordered polaronic lattice deformations establish an order, while macroscopic quantum coherence among excitons simultaneously emerges. Recombination of excitons in this state culminates in superfluorescence at high temperatures. Our study establishes fundamental connections between the transient superfluorescence process observed after the impulsive excitation of perovskites and general equilibrium phase transitions achieved by thermal cooling. By identifying various electron–lattice interactions in the perovskite structure and their respective role in creating collectively coherent electronic effects in solids, our work provides unprecedented insight into the design and development of new materials that exhibit high-temperature macroscopic quantum phenomena.

36 MATERIALS SCIENCE↗

Effective reduction of PdCoO 2 thin films via hydrogenation and sign tunable anomalous Hall effect

PdCoO 2 , belonging to a family of triangular oxides called delafossite, is one of the most conducting oxides. Its in-plane conductivity is comparable to those of the best metals and exhibits hydrodynamic electronic transport with an extremely long mean free path at cryogenic temperatures. Nonetheless, it is nonmagnetic despite the presence of the cobalt ion. In this work, we show that a mild hydrogenation process reduces PdCoO 2 thin films to an atomically mixed alloy of PdCo with strong out-of-plane ferromagnetism and sign-tunable anomalous Hall effect. Considering that many other compounds remain little affected under a similar hydrogenation condition, this discovery may provide a route to creating novel spintronic heterostructures combining strong ferromagnetism, involving oxides and other functional materials.

36 MATERIALS SCIENCE↗